Skip to content

eaxsim scenario checks and eaxsimctl test

PlatformReferenceCloudView as Markdown

A scenario can carry pass/fail checks (expect). eaxsimctl test runs the scenario locally in virtual time and checks them; eaxsim -report and eaxsim-cloud check them too, so a build pipeline can gate on the result either on its own machine or on eaxsim-cloud. Every key of an expect entry is in the generated eaxsim scenario reference.

"expect": [
{"id": "settled", "plc": "tank-*", "signal": "T1.level_m", "check": "at", "at_s": 95, "cmp": "within", "value": 2.0, "tol": 0.1},
{"id": "no-spill", "signal": "T1.level_pct", "check": "never", "cmp": ">", "value": 95},
{"id": "alarm-on-fault", "plc": "tank-*", "var": "HighAlarm", "check": "eventually", "after_fault": "pump-on", "within_s": 30, "cmp": "==", "value": true},
{"id": "alarm-clears", "plc": "tank-00", "var": "%QX0.1", "check": "always", "from_s": 250, "to_s": 300, "cmp": "==", "value": false}
]
  • What is checked: a plant signal (signal, a model port) or a PLC variable (var, by name, or a direct address with its type such as %MD104:REAL). Exactly one of the two.

  • check:

    • at: the first sample at or after at_s;
    • always: every sample from from_s to to_s;
    • never: no sample in that window;
    • eventually: some sample in the window, or within within_s.

    A window without to_s runs to the end of the run.

  • cmp: ==, !=, <, <=, >, >=, or within (|x - value| <= tol). value is a number, or true / false.

  • Times are simulated seconds from the start of the run, or from the start of the fault that after_fault names, on each PLC that has it.

  • plc is a pattern over PLC ids; empty means every PLC. Every matching PLC must pass.

  • Read only. A check never writes a variable, forces a signal or injects a fault. An unknown key is refused, as everywhere else in a scenario. A scenario holds at most 1000 checks, and their ids are unique.

  • The checks are evaluated at every virtual tick, so the verdict is the same at any speed. They are evaluated by eaxsimctl test, by eaxsim -report and, through it, by eaxsim-cloud (below). A realtime run is never checked.

eaxsimctl test [-until S] [-speed X] [-workers N] [-report FILE] [-timeout D] SCENARIO.json

The scenario runs locally, in virtual time, with no broker and no API: nothing outside the process sees or commands its PLCs. The flags are in the eaxPLC command-line reference. The JSON report goes to standard output, and also to -report when given.

Exit code Meaning
0 every check passed
1 a check failed, or was not covered by the run (inconclusive), or a PLC stopped
2 no run: a usage error, an invalid scenario, a build error, or a timeout
eaxsim -scenario SCENARIO.json -report FILE [other flags]

With -report, a virtual run evaluates the scenario’s expect entries at every tick, writes the eaxsim.checks/1 report to FILE when the run ends, and adds "verdict" to the file named by -stats-file. Without -report, eaxsim runs and exits as before.

Exit code Meaning
0 the run ended and every check passed
1 a check failed, was not covered by the run (inconclusive), or a PLC stopped; also any run that failed
2 usage error: -report on a realtime run or on a scenario without expect entries, refused before anything runs
  • Checked runs. A start in virtual time of a scenario with expect entries runs eaxsim with -report. Any other start is not checked.
  • Run state. A checked run whose checks do not pass still ended: it ends stopped, not failed, and is metered as usual. eaxsim exiting 1 without its report is a failed run.
  • verdict. The simulation (GET /v1/sims/{id}) carries "verdict": "pass" or "fail" for its last checked run (fail covers a report verdict of fail or error). It is cleared at each start, and absent when the last run was not checked.
  • GET /v1/sims/{id}/report (tenant API key, the tenant’s own simulations only) returns the last checked run’s report. 404 when the last run was not checked or has not ended. A report file uploaded with the scenario is removed at start and never served. The route is in the eaxsim-cloud HTTP API reference.
eaxsimctl wait [-timeout 10m] [-interval 1s] SIM
eaxsimctl report [-o FILE] SIM
Command Exit 0 Exit 1 Other
wait the run ended (stopped) and, for a checked run, its verdict is pass the run failed, or a checked run ended with a verdict other than pass 3: timeout
report the report’s verdict is pass the verdict is not pass, or there is no report 2: usage error

Behaviour change: eaxsimctl wait used to exit 0 for any run that ended, whatever its checks. A run without checks is unchanged. eaxsimctl report prints the report and, with -o, also writes it to FILE.

The eaxPLC repository has a ready example: the scenario examples/sim/ci/checks/tankfarm.json (4 tanks, PI level control with a high-level alarm, 5 checks) and the gate script examples/sim/ci/checks-gate.sh. Its exit code is the verdict, and it writes the report to REPORT (default checks-report.json) for the job’s artifacts.

sh examples/sim/ci/checks-gate.sh # local: eaxsimctl test, no key
EAXSIM_KEY=... sh examples/sim/ci/checks-gate.sh cloud # eaxsim-cloud: create, start, wait, report, delete
  • Local runs eaxsimctl test on the CI machine: no broker, no API, no key.
  • cloud uploads the scenario with its program, starts it in virtual time, waits, fetches the report and deletes the simulation. EAXSIM_URL is the eaxsim-cloud address. Keep EAXSIM_KEY in the CI’s secret store, never on the command line, where it would show in the job log.
  • Exit codes: 0 pass, 1 a check failed or was not covered, or a PLC stopped, 2 no run, 3 (cloud) the run did not end within TIMEOUT (default 15m).
Key Meaning
schema eaxsim.checks/1
scenario the scenario’s name
verdict pass, fail or error
error why there was no run (verdict error)
start_s, end_s, ticks the simulated time of the first and last sample, and the ticks run
summary counts: pass, fail, inconclusive
checks one result per check (below)
plc_errors PLCs stopped during the run: plc, error

Each result repeats the check (id, description, check, plc, signal or var, cmp, value, tol, the times, after_fault) and adds:

Key Meaning
status pass, fail or inconclusive (the run did not cover it; counts as a failure)
plcs, failed, inconclusive PLCs checked, and how many failed or were not covered
first_fail_s, first_fail_plc the first failure: when (simulated seconds; for eventually, its deadline) and on which PLC
met_s, met_plc for at and eventually: when the last PLC met it
observed the value at the first failure, or at met_s
min, max, samples the range of the samples taken on every PLC, and their number
note a remark on the result