Skip to content

ST language: phase 3 additions

eaxPLCReferenceFreeProView as Markdown

The Structured Text additions of the eaxPLC data model, with the rules the compiler applies. Messages are quoted as the compiler writes them; X, T and similar stand for your names. Parser messages start with line N:.

For what these features are for, see Data model: global variables, data types and external access.

These words are keywords, in any letter case, and can no longer name a variable, type, POU or enumeration value:

TYPE END_TYPE STRUCT END_STRUCT UNION END_UNION FUNCTION END_FUNCTION VAR_GLOBAL VAR_EXTERNAL

A text that uses one as a name fails with a message naming it, for example line 4: expected variable name, got “Type” (TYPE is a reserved keyword: rename the variable). At start and at every link, the PLC scans the project for such names, lists them as Keyword clash in the tag database and the project state (keyword_clashes), and audits PROJECT_KEYWORD_CLASH. The running program is not affected; its next test or deploy fails until you rename. Add {attribute 'was' := 'OldName'} on the new name to keep the value.

A DUT POU holds exactly one TYPE, named like the POU, and nothing else.

TYPE ST_Recipe :
STRUCT
Temp_SP : REAL := 180.0;
{attribute 'access' := 'read'}
Time_s : DINT := 600;
END_STRUCT
END_TYPE
TYPE U_Word :
UNION
AsWord : WORD;
AsBytes : ARRAY[0..1] OF BYTE;
END_UNION
END_TYPE
TYPE E_State : (Idle, Run := 10, Fault) DINT;
END_TYPE
TYPE T_Speed : INT(0..MaxSpeed);
END_TYPE
TYPE T_Level : REAL;
END_TYPE
Form Rules
STRUCT ... END_STRUCT At least one member. Members may have initial values and access and write_range attributes (they apply to the member in every instance; access can only narrow), not addresses. A member cannot be a function block instance (declare it in a FUNCTION_BLOCK). Members are naturally aligned, at most to 8 bytes.
UNION ... END_UNION Members are elementary types (not STRING) or arrays of them, with no initial value. All start at offset 0.
Enumeration (A, B := n, C) [base] Base type an integer type, default INT. A value without := is the previous one plus 1 (the first is 0). Values and names are unique and fit the base type.
Subrange base(lo..hi) Base an elementary integer type; bounds are constant expressions.
Alias type T : type; Any type except a function block.

A type may refer to a type declared later. A default value on the type itself (TYPE T : INT := 5;) is not supported: give the variables initial values. Subranges can also be written inline on a variable: Speed : INT(0..3000);.

  • A value is E_State.Run, or Run when only one enumeration declares it and no variable is named so.
  • Enumerations compare (=, <>, <, …) only with values of their own type, and can be CASE selectors.
  • Convert with <Enum>_TO_<int> and <int>_TO_<Enum>: E_STATE_TO_INT(State), INT_TO_E_STATE(n).

A GVL POU holds one or more VAR_GLOBAL blocks and nothing else.

VAR_GLOBAL
LineSpeed : REAL := 12.5;
Lamp AT %QX0.1 : BOOL;
END_VAR
VAR_GLOBAL CONSTANT
NumRecipes : INT := 20;
END_VAR
VAR_GLOBAL RETAIN
Counter : DINT;
END_VAR
  • CONSTANT and RETAIN qualify a block. Every CONSTANT needs a value. RETAIN is not persistent yet: a cold reset and a power cycle reset it.
  • A global may be located (AT %...). An input-located variable (AT %I...) cannot have an initial value.
  • Global names are unique across all lists, and differ from every POU name and every list name.
  • VAR_GLOBAL is refused in a PROGRAM, FUNCTION_BLOCK or FUNCTION.

Optional in PROGRAMs, FUNCTION_BLOCKs and FUNCTIONs: a POU can use a global by its name without it.

VAR_EXTERNAL
LineSpeed : REAL;
END_VAR
VAR_EXTERNAL CONSTANT
NumRecipes : INT;
END_VAR

The type must equal the global’s; no address or initial value. VAR_EXTERNAL CONSTANT makes the global read-only inside that POU.

A POU looks a name up in its own declarations, then among the globals. A PROGRAM variable with a global’s name is an error. In a FUNCTION_BLOCK or FUNCTION, a local may hide a global, with a warning.

PumpRun AT Motors[3].Run : BOOL;
Ready AT Status.3 : BOOL; (* bit 3 of Status *)
Oven2_SP AT Recipes[2].Temp_SP : REAL;
  • Declared in VAR_GLOBAL or in a PROGRAM’s VAR only. Not in a FUNCTION_BLOCK, a FUNCTION, inputs, outputs, temporaries, or CONSTANT or RETAIN blocks.
  • The target is a global or, in a PROGRAM, a variable of that program; a global alias targets a global. Targets may go through members (.Member), array elements with constant indexes ([3], [N+1]) and one bit (.n) of an integer or bit-string variable (not TIME, BOOL or an enumeration).
  • The alias’s type is exactly the target’s type, BOOL for a bit.
  • No initial value and no storage of its own. An alias of an alias resolves, at most 4 aliases deep.
  • Its external access is the narrower of its own and its target’s, and applies to its name. Its write range is the narrower of its own and its target’s (the leaf member’s own range when it targets a member).
  • A bit alias of an integer that has a write range is read-only from outside.

A FUN POU holds exactly one FUNCTION, named like the POU.

FUNCTION Scale : REAL
VAR_INPUT
IN, LO, HI : REAL;
END_VAR
VAR
Span : REAL;
END_VAR
Span := HI - LO;
Scale := LO + IN * Span;
END_FUNCTION
  • Sections: VAR_INPUT, VAR_IN_OUT, VAR, VAR_TEMP, VAR_EXTERNAL. No VAR_OUTPUT, no function block instances, no addresses, no RETAIN, no aliases.
  • The result is set by assigning to the function’s name; no variable may take that name.
  • Called in expressions with formal (Scale(IN := x, LO := 0.0, HI := 100.0)) or positional (Scale(x, 0.0, 100.0)) arguments, not both in one call. Every in/out parameter must be passed.
  • Locals start from their initial values at every call. A FUNCTION cannot be called in an initial value.
  • No recursion, direct or through other functions.
  • The name may not be a standard function’s or a PROGRAM’s.

In FUNCTION_BLOCKs and FUNCTIONs (not PROGRAMs):

FUNCTION_BLOCK FB_Dose
VAR_IN_OUT
Recipe : ST_Recipe;
END_VAR
...
END_FUNCTION_BLOCK
Dose1(Recipe := Recipes[Step]);
  • Copy-in, copy-out: the actual is copied into the parameter before the body and back after it.
  • The actual is a variable of exactly the parameter’s type: no expression, no CONSTANT, no bit.
  • A parameter is at most 4096 bytes.
  • No CONSTANT and no initial value on the parameter.
  • A FUNCTION_BLOCK’s in/out is passed in the call (Recipe := variable), never read out with =>.

A pragma is text in braces. An attribute pragma on the line(s) before a declaration attaches to it (with several names in one declaration, to each):

Attribute Value Effect
{attribute 'access' := 'none'} none, read, read_write External access. Default without it: read_write (a CONSTANT is always read at most).
{attribute 'write_range' := '0.0..120.0'} 'low..high', numbers, low ≤ high Bounds external writes; narrowed further by a subrange type.
{attribute 'was' := 'Line2.Speed'} an earlier storage name Migrates the value from that variable at the next switch, while it exists in the running program.
{attribute 'network' := ...} reserved Accepted and kept as written, with the warning reserved for networked tags (a later version): not applied.

Attributes are part of the text, so of the program hash: what the PLC enforces is signed. A value written 'it''s' or 'it$'s' holds a quote.

An attribute applies only where the PLC enforces it. Anywhere else it is a compile error, never silently dropped:

Declared on Attributes that apply
A global variable, a PROGRAM variable access, write_range, was, network
A STRUCT or UNION member, a FUNCTION_BLOCK member access, write_range
An alias access, write_range
A FUNCTION’s variables (a hidden frame), a VAR_EXTERNAL, a TYPE itself none

An attribute must stand directly before a declaration: one before VAR_GLOBAL, or before no declaration at all, is an error.

Two pragmas belong to the PLC alone:

  • {gvl Name}: written by the linker before each list’s VAR_GLOBAL blocks, so the compiler knows which list declares each global. A POU that holds one is refused: line N: the {gvl …} line is written by the PLC, never in a POU.
  • {project key := value; ...}: the project compile settings, written by the linker as the first line of the linked text when a setting differs from its default (subrange_violation := 'clamp' | 'fault', migrate_cap_bytes := 1..16777216). A POU, an import or a restored tree that holds one is refused. See Set the project compile settings.

Any other pragma is a warning and is ignored, never an error.

Array bounds, STRING lengths, subrange bounds and enumeration values accept constant integer expressions: integer literals, CONSTANT names (the POU’s own first, then global ones), unary minus, + - * / and MOD.

VAR_GLOBAL CONSTANT
N : INT := 20;
END_VAR
...
Buffer : ARRAY[1..N*2+1] OF INT;
Name : STRING[N];

A STRING length is 1 to 65535.

Message Cause
line N: attribute 'access' := 'X': the access is none, read or read_write bad access value
line N: attribute 'write_range' := 'X': expected 'low..high' (numbers, low <= high) bad range
line N: attribute 'was' needs the earlier name empty was
line N: attribute 'X' given twice the same attribute twice on one declaration
X: attribute 'Y' is not applied on Z (only 'access' and 'write_range' apply there) an attribute such as was or network on a member or an alias; Z is TYPE T (a member), FUNCTION_BLOCK F (a member) or an alias (it has no storage of its own)
X: attribute 'Y' is not applied on FUNCTION F (its variables are a hidden frame) (no attribute applies there) an attribute on a FUNCTION’s variable
X: attribute 'Y' is not applied on a VAR_EXTERNAL (put it on the global) (no attribute applies there) an attribute on a VAR_EXTERNAL
TYPE T: attribute 'Y' is not applied on a TYPE (put it on a member or a variable) (no attribute applies there) an attribute on the type itself
line N: attribute 'X' before VAR_GLOBAL is not applied: put it on the declaration an attribute before the block keyword
line N: attribute 'X' is not before a declaration: it is not applied an attribute followed by no declaration
line N: expected variable name, got "X" (X is a reserved keyword: rename the variable) a keyword used as a name (also expected a type name …, expected an enumeration value …)
line N: {project} must be the first line of the text ..., line N: a second {project} pragma ... a hand-written {project} line
Message
TYPE T: the name is an elementary type / the name is a library block
TYPE T declared twice
TYPE T: by-value cycle T -> U -> T (a type cannot hold itself)
TYPE T: M: a member cannot have an address
TYPE T: M: a function block instance cannot be a member of a STRUCT (declare it in a FUNCTION_BLOCK)
TYPE T: M: a UNION member is an elementary type or an ARRAY of one, not X
TYPE T: M: a UNION member cannot have an initial value
TYPE T: a STRUCT needs at least one member (or a UNION)
TYPE T: M declared twice
TYPE T: the base type of an enumeration is an integer type, not X
TYPE T: A and B have the same value n
TYPE T: V = n is outside SINT
TYPE T: a subrange needs an elementary integer base type, not X
TYPE T: an alias of a function block is not supported (declare an instance of X)
line N: TYPE T: a default value on a type is not supported (give the variables initial values)
line N: enumeration T has no values
cannot compare E_A and E_B: different enumerations
cannot assign INT to E_STATE (an enumeration holds only its own values: convert with INT_TO_E_STATE)
X is a value of several enumerations: write E_A.X or E_B.X
E_STATE has no value X
CASE on E_STATE: X is a value of the enumeration E_OTHER
+ is not defined for an enumeration (only comparisons are)
FOR variable I is a subrange (T): use a plain integer
T: the fault mode supports subrange bounds within DINT
Message
X: N: X is not a CONSTANT with a value
X: ...: not a constant integer expression
X: ...: 2.5 is not an integer
X: ...: division by zero in a constant
X: ...: the constant depends on itself
X: STRING length n out of range 1..65535
X: subrange bound ...: ...
Message
global variable X declared twice (in GVL_A and GVL_B)
global variable list X: the name is also a global variable
global variable X (GVL_Line): the name is a PROGRAM of the project (or a FUNCTION_BLOCK, a TYPE, a FUNCTION)
X is a global variable (GVL_Line): rename the local or use the global
CONSTANT X needs a value
VAR_EXTERNAL X: there is no global variable X (declare it in a global variable list)
VAR_EXTERNAL X: no address or initial value here (they belong to the global)
VAR_EXTERNAL X : INT, but the global variable (GVL_Line) is DINT
line N: VAR_GLOBAL belongs in a global variable list, not in a PROGRAM or FUNCTION_BLOCK (declare the global there and use VAR_EXTERNAL)
X: an input (%I) cannot have an initial value: the inputs set it every cycle, and a new set's first cycle would show the initial value instead of the input (its initialisation runs after the inputs are read)
Message
alias X: an alias is declared in VAR_GLOBAL or a PROGRAM's VAR, not in VAR_INPUT (or another section)
FUNCTION_BLOCK F: X: an alias is declared in VAR_GLOBAL or a PROGRAM (a block takes in/out parameters)
alias X: an alias cannot be CONSTANT (narrow its access with {attribute 'access' := 'read'})
alias X: an alias has no storage of its own: RETAIN does not apply
alias X: an alias has no initial value (its target has)
alias X AT T: T is not a declared variable
alias X AT T: a global alias targets a global variable
alias X AT T: an alias's index is a constant (an alias names one fixed element)
alias X AT T: index n is outside [lo..hi]
alias X AT T: bit n of X: only an integer or bit string has bits
alias X AT T: bit n is outside INT (bits 0..15)
alias X AT T: Y has no members (it is a INT)
alias X AT T: Y is not an ARRAY
alias X : INT, but T is DINT (an alias has exactly its target's type)
alias X : INT: a bit (T) is a BOOL
alias X: cycle A -> B -> A (an alias must lead to a variable)
alias X: more than 4 aliases in a chain (point it at the variable)
Message
FUNCTION F: the name is a standard function or a PROGRAM
FUNCTION F: a FUNCTION returns a value, not a function block instance
FUNCTION F: X: VAR_OUTPUT is not supported in a FUNCTION (return the value, or use VAR_IN_OUT)
FUNCTION F: X: a variable cannot be named like its FUNCTION (the name is the result)
FUNCTION F: X: a FUNCTION cannot declare function block instances (use a FUNCTION_BLOCK)
FUNCTION F: X: direct addresses are not allowed inside a FUNCTION
FUNCTION F: X: a FUNCTION's variables do not persist between calls: RETAIN does not apply
FUNCTION F: recursive call F -> G -> F (a FUNCTION cannot call itself, directly or through others)
FUNCTION F calls itself (a FUNCTION cannot be recursive)
FUNCTION F has no parameter X / F.X is not a VAR_INPUT or VAR_IN_OUT / F: parameter X given twice
F takes n argument(s), got m
F: the in/out parameter X must be passed
the call of F mixes formal (name := value) and positional arguments
F(X => ...): a FUNCTION has no outputs (use its result, or a VAR_IN_OUT)
F: a FUNCTION cannot be called here (an initial value is set before any code runs)
F: the in/out parameter X needs a variable of type T, not an expression
F: the in/out parameter X is T, Y is U (an in/out actual has exactly the parameter's type)
F: Y is a CONSTANT: it cannot be passed to the in/out parameter X
F: Y is a bit: it cannot be passed to the in/out parameter X
VAR_IN_OUT X is n bytes: in/out parameters are copied in and out, at most 4096 bytes (pass a global variable instead)
... X: a VAR_IN_OUT has no value of its own (no CONSTANT, no initial value): the call passes it
X: VAR_IN_OUT is for function blocks and functions, not for a PROGRAM
FB.X is a VAR_IN_OUT: pass it with X := variable
Message
the DUT POU T must hold exactly one type, TYPE T : ... END_TYPE
the DUT POU T holds TYPE T and nothing else
the GVL POU G holds only VAR_GLOBAL blocks, not VAR (or no FUNCTION_BLOCK, …)
the GVL POU G holds at least one VAR_GLOBAL ... END_VAR block
the FUN POU F must hold exactly one unit, FUNCTION F : <type> ... END_FUNCTION
a FUNCTION declares no VAR_GLOBAL (globals live in a GVL POU)
line N: the {gvl ...} line is written by the PLC, never in a POU
P line N: {project ...} is written by the PLC only (the project's compile settings, first line of the linked text): remove it, and set the settings with PUT /api/project/settings
Message Meaning
FUNCTION_BLOCK F: X hides the global variable X (GVL_Line) (also FUNCTION F: ...) a local wins over a global inside the block
F: Y is passed to the in/out parameter X and the body of F also uses the global Y: ... copy-in/out means the body sees the value from before the call
line N: unknown pragma {X}: ignored, line N: unknown attribute 'X': ignored not understood, ignored
X: attribute 'network' is reserved for networked tags (a later version): not applied accepted (kept for exchange), not enforced yet
X moved to a new offset: a located variable or direct address now uses its memory; its value is reset storage taken by a located variable
X: migrated to its new type; dropped (their values are lost): ... members removed from a migrated type
X: not migrated, initialised: its old storage (bytes a..b) is covered by a located variable or direct address of the new program (bytes c..d), so its values cannot be copied see Online changes to data structures
info: X: attribute 'was' := 'Y': no variable Y in the running program: nothing to migrate (the attribute can be removed) was has nothing to do
info: X: attribute 'was' := 'Y': Y is still declared: ignored the old name still exists
info: X: attribute 'was' := 'Y': a located variable keeps its address: ignored located variables are not migrated

Cross-reference checks (eaxPLC Standard and Performance)

Section titled “Cross-reference checks (eaxPLC Standard and Performance)”
Check Finding
global-written-several-tasks a global written from POUs run by different tasks
global-unused a global declared but never read or written
alias-target-written-directly an alias and its target are both written (information)
fb-uses-global a FUNCTION_BLOCK or FUNCTION body uses a global (information: it hurts reuse)

They appear in the cross-reference’s Checks, in the impact report, and as row warnings in the tag database.