Constants, outside writes and forces
A VAR CONSTANT has storage in the process image like any other variable. The program never changes it, and eaxPLC makes sure nothing outside the program does either: every path that writes or forces a value refuses a constant’s storage, by the constant’s name or by a direct address over its bytes (%MW40, %QX1.2, a %M word that covers part of a STRING or of a FUNCTION_BLOCK’s constant member). Each refusal is audited.
The same runtime also protects writes and forces against a program switch: a value checked against one program version is never applied while another version runs.
Which constants are protected
Section titled “Which constants are protected”| Constant | Example |
|---|---|
| A PROGRAM’s constant, any type | VAR CONSTANT Limit : INT := 100; Label : STRING[8] := 'abc'; END_VAR |
| A located constant: the bit or the bytes it names | VAR CONSTANT Lamp AT %QX1.2 : BOOL := TRUE; K AT %MW40 : INT := 7; END_VAR |
| A FUNCTION_BLOCK’s constant member, in every instance and every array element | FUNCTION_BLOCK Valve VAR CONSTANT MaxOpen : INT := 50; END_VAR (so Line.Valve1.MaxOpen, Valves[2].MaxOpen) |
The neighbours stay writable: another bit of the same byte, the next word.
Refusals per path
Section titled “Refusals per path”| Path | A write onto a constant | Audit record |
|---|---|---|
POST /api/write (HTTP and the NATS API) |
409, "code": "CONSTANT_READ_ONLY". All or none: a batch with one constant writes nothing. |
IO_WRITE / WRITE_DENIED, one per entry of the request, cause refused (409): CONSTANT_READ_ONLY ... |
POST /api/force (HTTP and the NATS API) |
409, "code": "CONSTANT_READ_ONLY". Unforce is never refused. |
IO_FORCE / FORCE_DENIED |
| OPC UA | A constant is published read-only (no write bit in its access level); a write answers BadNotWritable. |
TAG_WRITE / WRITE_REFUSED under the OPC UA user |
UNS commands (uns.command.<path>) |
A constant is published read-only; the reply is an error containing CONSTANT_READ_ONLY. |
TAG_WRITE / WRITE_REFUSED under the user |
| Modbus TCP server (FC5 write single coil, FC6 write single register) | Exception 02 (illegal data address). |
TAG_WRITE / WRITE_REFUSED under modbus <client address> |
GET /api/registry, the cross-reference’s UNS details |
A constant is listed with "writable": false and "constant": true, whatever the writable patterns say. |
- |
Inputs a fieldbus drives (IO_INPUT_DRIVEN). The same paths refuse an outside write whose storage overlaps a %I input that a configured bus drives (EtherCAT, CANopen, EtherNet/IP scanner, Modbus TCP master, MQTT inputs). For an MQTT entry this is every byte or bit it writes: its value, its quality bit, status, timestamp and age, and its source’s status bit (see Connect MQTT and Sparkplug B inputs). The overlap is checked to the bit: a word over one driven bit is refused, while another bit of a driven byte is not. The refusals are:
POST /api/write:409,"code": "IO_INPUT_DRIVEN", naming the bus, device and entry; the whole request is refused and auditedWRITE_DENIED;- OPC UA:
BadNotWritable; - Modbus TCP server: exception
02; - UNS and MQTT commands: refused, with the code in the reply.
While the PLC does not know which inputs its buses drive (fieldbus.json did not load, the devices were halted, or the I/O is suspended), every outside write into %I is refused this way; %Q and %M stay writable. Forces are unchanged: a force on a driven input is accepted (with the force right, audited) and wins over the device at every cycle, as the deliberate override.
Inputs a simulator drives (eaxsim). On a simulated PLC that an eaxsim host runs, the simulator writes its sensors into %I at the start of every scan, as a fieldbus does, and the same paths refuse an outside write onto them with IO_INPUT_DRIVEN: any byte of an analog sensor (%IW, %ID, %IB), or the same bit of a digital one (a byte or word over one simulated bit is refused; another bit of that byte is not). The message names the model port and address, for example eaxSim model port T1.level_m -> %IW0. A simulated PLC whose simulator input map is not registered, or cannot say what it drives, refuses every outside write into %I (%Q and %M stay writable). The simulator’s own writes (sensors, a scenario’s init values, a restored snapshot, sensor faults) are not checked, and a force on a simulated input is accepted and holds against the simulator. A real runtime is never marked simulated and is unchanged.
Advertised read-only. A variable whose storage a fieldbus, MQTT or simulator input drives is listed read-only: "writable": false in GET /api/registry, and no write bit in its OPC UA AccessLevel and UserAccessLevel. This is asked at each read, so it follows every fieldbus Apply, at bit level (a driven bit is read-only, another bit of the same byte stays writable). While the driven inputs are not known, every %I variable is listed read-only; %Q and %M are unchanged. The cross-reference’s UNS writable flag does not take the driven inputs into account yet; the write itself is refused either way.
Writes across a fieldbus Apply. An outside write is checked against the driven inputs when it is queued. If a fieldbus Apply (or a halt) changes the driven inputs before the cycle boundary that would apply it, the write is checked again there: onto an input the new configuration drives (or into %I while the inputs are not known) it is dropped, never written, and audited IO_INPUT_DRIVEN under who asked for it (/api/write: IO_WRITE / WRITE_DENIED; UNS, MQTT, OPC UA and Modbus TCP: TAG_WRITE / WRITE_REFUSED), with a cause ending … the fieldbus inputs changed after the write was checked (fieldbus Apply); dropped at the cycle boundary, not written. The client had already been told the write was queued. Writes onto storage the new configuration does not drive land as before; forces are not concerned. The simulator’s input map never changes while the PLC runs, so it needs no such re-check.
The runtime builds its Modbus TCP server with this check installed before the server listens: there is no moment after start-up when a Modbus write is taken unchecked. A Modbus server without its check refuses every write with exception 04.
What GET /api/registry tells per symbol
Section titled “What GET /api/registry tells per symbol”Each symbol (a variable with access none is not listed) carries its write metadata, so a client such as eaxScada can grey out an input and refuse a value before sending it:
| Field | Meaning |
|---|---|
writable |
The effective answer: access read_write, not a constant, allowed by the --uns-writable patterns, and no fieldbus, MQTT or simulator input drives its storage now. |
access |
The variable’s own external access, read or read_write, before the writable patterns. |
constant |
true for a VAR CONSTANT. |
min, max |
The bounds of an outside write (the write range, narrowed by a subrange type). Only when bounded on that side, and only for numbers. |
enum |
The enumeration’s values in declaration order, as name / value pairs. Only for an enumeration. |
The runtime still checks every write itself: this metadata only lets a client refuse early.
Forces and constants
Section titled “Forces and constants”| Event | What happens to a force onto a constant’s storage |
|---|---|
| Force requested | Refused, 409 CONSTANT_READ_ONLY, audited FORCE_DENIED. |
| Deploy of a program that makes a forced location a constant (by name or by direct address) | The force is released by the deploy: audited FORCE_RELEASED, cause automatic: deploy vN made <name> a CONSTANT: a constant is never forced. A constant is never forced, not even by a force made before. |
| Online-edit test of a program that makes a forced location a constant (a PROGRAM’s constant, located or not, or a FUNCTION_BLOCK member) | The test is refused, 409 forced_symbol_changes, naming each force (%MW40 (W constant), Speed (constant)); nothing changes. A test never releases a force: unforce first, then test. |
Writes across a deploy or an online edit
Section titled “Writes across a deploy or an online edit”An outside write is resolved (a name to an offset) and checked (not a constant, not forced) against the program that runs, then queued; the scan applies it at the next cycle boundary. A deploy, an online-edit test or an untest switches the program at a cycle boundary too. Each queued write therefore carries the version of the program it was checked against, and is applied only while that version still runs:
- Program version
- Queued write
- Checked, never queued
- Written
- Dropped or refused
Read as text
Version 3 of the program runs, then a deploy or an online edit switches to version 4 at a cycle boundary. A write checked against version 3 and applied while version 3 still runs is written. A write checked against version 3 that is still waiting when version 4 starts is dropped at that boundary, never applied, and audited. A write checked against version 3 but queued after the switch is refused at once. A write checked against version 4 is written at the next boundary.
Time runs left to right: version 3 runs, then version 4 runs. Every tick is a cycle boundary; the switch happens at one too.
Program
- Running program: one version per cycle (v3; v4)
Outside writes
- 1. Checked against v3: applied while v3 runs (queued; written)
- 2. Checked against v3: still waiting at the switch (queued; dropped). Dropped at the cycle boundary, never applied: WRITE_STALE_PROGRAM, audited under the user or client who wrote. /api/write had already answered 200.
- 3. Checked against v3: queued after the switch (refused at once). WRITE_STALE_PROGRAM at once, nothing written: 409 on /api/write, BadInvalidState on OPC UA, an error on UNS, exception 04 on Modbus TCP; audited.
- 4. Checked against v4: applied at the next boundary (queued; written)
| When the program changed | /api/write (HTTP, NATS) |
UNS, OPC UA | Modbus TCP |
|---|---|---|---|
| Before the write was queued | 409, "code": "WRITE_STALE_PROGRAM", nothing written; audited IO_WRITE / WRITE_DENIED per entry |
The write is refused: OPC UA answers BadInvalidState, UNS answers with an error; audited TAG_WRITE / WRITE_REFUSED |
Exception 04; audited TAG_WRITE / WRITE_REFUSED under the client |
| After it was queued, before the cycle that would apply it | Dropped at the cycle boundary, never applied (the request had already answered 200); audited IO_WRITE / WRITE_DENIED under the user who wrote, with the request id, cause refused (409): WRITE_STALE_PROGRAM ... dropped at the cycle boundary, not written |
Dropped, never applied; audited TAG_WRITE / WRITE_REFUSED (external write (UNS or OPC UA) ... WRITE_STALE_PROGRAM) |
Dropped, never applied; audited TAG_WRITE / WRITE_REFUSED under the client |
An OPC UA write the runtime cannot queue because its write queue is full answers BadResourceUnavailable, nothing written; write again. A write to a constant answers BadNotWritable (see above).
So a write never lands on a variable that moved (its old bytes may now be another variable’s), and never on storage the new program makes a constant. Write again once the new program runs. A write made while no program is loaded is not tied to a version.
The cause names both versions: WRITE_STALE_PROGRAM: the write was checked against program version 3 and version 4 runs now (a deploy or an online edit switched the program); write again.
Forces follow their own rule across a deploy: a force made by name follows its variable to its new place, or is released (FORCE_RELEASED) when the variable is gone, changed type or became a constant; a force made by direct address stays unless the new program makes it a constant.
Link order of a project’s FUNCTION_BLOCKs
Section titled “Link order of a project’s FUNCTION_BLOCKs”A project deploy links the project’s POUs into one source text, the same bytes on every run:
- every FUNCTION_BLOCK, by name (case-insensitive), except that a block comes after every block it holds an instance of (directly or in an array);
- every other PROGRAM, by name;
- the main PROGRAM, last.
A project whose blocks hold no other block links in plain name order, as before. Blocks that hold instances of each other in a cycle (A holds B, B holds A) are a link error: 422, PROJECT_LINK_FAILED, the FUNCTION_BLOCKs hold instances of each other in a cycle (A -> B -> A): a block cannot contain itself.