# eaxware docs > Documentation for eaxScada (SCADA/HMI), eaxPLC (IEC 61131-3 soft PLC) and eaxCloud (fleet subscription), and the platform they share. Each link points to a clean Markdown copy of the page. - eaxScada: SCADA and HMI in a single Go binary, with a tag engine, an embedded NATS Unified Namespace, a web screen designer, an operator runtime, a historian, ISA-18.2 alarms and a governed MCP gateway for AI assistants. - eaxPLC: a deterministic IEC 61131-3 soft PLC (Structured Text) with hot reload, Modbus TCP, EtherNet/IP and EtherCAT masters, an OPC UA server, edge runtimes, the eaxSim plant simulator and eaxCloud simulation. - Platform: installation, the NATS Unified Namespace, the security model (users, roles, audit, 21 CFR Part 11), eaxCloud and the editions (Free, Starter, Pro, Enterprise, Cloud). Full text: https://eaxware.com/docs/llms-full.txt. Per product: https://eaxware.com/docs/llms-eaxscada.txt, https://eaxware.com/docs/llms-eaxplc.txt, https://eaxware.com/docs/llms-platform.txt. Security, accounts, audit trail, 21 CFR Part 11, backups and encryption in one smaller file: https://eaxware.com/docs/llms-security.txt. ## eaxScada: Tutorial - [Build your first 2D screen](https://eaxware.com/docs/eaxscada/tutorials/build-your-first-2d-screen.md): From an empty project to a live operator screen in about 15 minutes - create four tags, draw a tank, a pump and a valve, join them with pipes, bind them, give the pump a command with a confirmation, add a setpoint input, deploy and operate it in the runtime. - [Build your first 3D scene](https://eaxware.com/docs/eaxscada/tutorials/build-your-first-3d-scene.md): In about 15 minutes, build a 3D scene of a tank, a pump and a valve, drive the tank's level, the pump's state and the valve's colour from tags, deploy it and look at it in the runtime and on a phone with the thumb sticks. - [Build your first isometric plant map](https://eaxware.com/docs/eaxscada/tutorials/build-your-first-isometric-plant-map.md): In about 15 minutes, draw a plant map on a tile grid - a tank, a pump and a valve joined by pipes - bind their states and level to tags, give the pump a command with a confirmation, deploy it and use it in the runtime and on a phone. ## eaxScada: How-to guide - [Use the 3D asset library](https://eaxware.com/docs/eaxscada/how-to/3d-asset-library.md): Add GLB and glTF equipment models (with their files, or as a .zip) to the 3D studio palette, install, replace and uninstall downloaded model packs, remove the built-in models a project does not use and restore them, manage the library in one grid, export the built-in parametric equipment as files, bind model parts to tags with a bindings sidecar, and edit models in Blender. - [Accept or refuse simulated PLCs](https://eaxware.com/docs/eaxscada/how-to/accept-simulated-plcs.md): An eaxPLC run by the eaxsim emulator (virtual commissioning) says it is simulated. eaxScada refuses its values by default; Tools > Simulated PLCs lets an Administrator accept them for commissioning, and then every value, alarm, trend and history sample from it is marked SIM. - [Activate a licence](https://eaxware.com/docs/eaxscada/how-to/activate-licence.md): Install, check or remove an eaxScada licence file, in the studio or through the API, and what the server does with a licence it cannot verify. - [Add a feature permission rule](https://eaxware.com/docs/eaxscada/how-to/add-a-feature-permission-rule.md): Pick a feature right from the list in the Security permission dialog (9 modules, 37 rights, each with its description and edition badge, plus the module wildcards), read why a right is disabled, read what a typed catch-all, prefix or DENY affects, and what a DENY does to the Administrator; the read-only route GET /api/auth/feature-rights. - [Add setpoint inputs](https://eaxware.com/docs/eaxscada/how-to/add-setpoint-inputs.md): Put numeric entries, sliders, spinners, text entries, toggle switches and selectors on a screen, with limits, units, confirmation and electronic signature enforced by the server for every writer of the tag. - [Connect alarms to the controller (handshake)](https://eaxware.com/docs/eaxscada/how-to/alarm-controller-handshake.md): Tell the controller when an alarm was shown to an operator and when it was acknowledged, let a field pushbutton acknowledge it, and define alarms that need no acknowledgement. Covers the Alarm_Manager write grant, the row warnings, high availability, retries and a worked Structured Text example. - [Allow remote access from eaxCloud](https://eaxware.com/docs/eaxscada/how-to/allow-remote-access.md): Decide at the site whether people can view, operate or engineer this eaxScada from eaxCloud, which accounts may sign in remotely, how to end every remote session at once, and the reason a session the site ends is reported with (switch_off, local_end, revoked). - [Analyse data in the Analytics workspace](https://eaxware.com/docs/eaxscada/how-to/analyse-data-in-the-analytics-workspace.md): Ask your own questions of the historian or the alarm journal in the Analytics tab of Analytics and Reports - write SQL in the code editor, set the time window and parameters, read the results with their quality marked (and the "Query ignores quality" warning), chart them, keep your own saved queries, turn a query into a dataset for reports, and go further with exports, extracts across sources and the server pivot - with the limits, who may use it and the HTTP routes. - [Approve remote changes that act on the plant](https://eaxware.com/docs/eaxscada/how-to/approve-remote-changes.md): Request another site user's approval for a remote change that acts on the plant without a deploy, approve it with a signature, and apply it once within 60 minutes; what stays refused remotely, and Starter. - [Arrange objects precisely](https://eaxware.com/docs/eaxscada/how-to/arrange-objects-precisely.md): Line objects up with a key object, give them the same width or height, space them evenly or by a fixed gap, zoom to the selection, find your way on a large screen with the minimap, work on one layer alone, place ruler guides, and change the designer's keyboard shortcuts. - [Attach pictures and documents in the AI assistant](https://eaxware.com/docs/eaxscada/how-to/attach-files-to-the-ai-assistant.md): Add screenshots, photos, PDF files and text files to a message in the AI assistant, what each AI service accepts, the limits, and what happens to the files. - [Build a dashboard](https://eaxware.com/docs/eaxscada/how-to/build-a-dashboard.md): Build a dashboard from the new cards - add a card from the card picker, give it queries, set its display, thresholds and overrides, add variables and a default time range, and convert the cards of earlier releases. - [Capture genealogy from a PLC](https://eaxware.com/docs/eaxscada/how-to/capture-genealogy-from-a-plc.md): Configure unit types and capture triggers so a PLC asks eaxScada to record a part, a lot or an operation, grant the Genealogy_Capture role its writes on the Ack and Err tags, program the handshake on any PLC (set the request, wait for Ack, read Err, reset) and check it on the Capture and configuration page. - [Check screens before deploying (Problems panel)](https://eaxware.com/docs/eaxscada/how-to/check-screens-before-deploy.md): Find what would not work on the operator's screen before you deploy - inputs and commands without a tag, conflicting limits, broken tags, screen-only interlocks, stop commands a failed sensor would block, low contrast, missing translations - in the editor's Problems panel, and block deploys while errors remain. - [Checkpoints: FAT, SAT and reverting](https://eaxware.com/docs/eaxscada/how-to/checkpoints-fat-sat-and-reverting.md): Take a named checkpoint of the whole engineering project at FAT, SAT or any step, compare it with the current project, revert the project to it with your e-signature, then lock, unlock or delete checkpoints; export the project to an archive and import one; schedule project archives and encrypted server backups with a recovery key, and restore a server backup - who may do what, what a revert leaves for you, and the refusals. - [Combine sources with extracts and pivot on the server](https://eaxware.com/docs/eaxscada/how-to/combine-sources-with-extracts.md): Query the historian and the alarms together in the Analytics workspace - read each source into an extract of your own session (with your read rights), join them with the source "Extracts (this session)", export the result, and group a result too large for the browser with "Pivot on the server" - with the session limits, the server-wide cap of sessions and its memory, who may use it, the audit records and the HTTP routes. - [Compare two versions of a screen](https://eaxware.com/docs/eaxscada/how-to/compare-screen-versions.md): Put two versions of a screen side by side (a saved revision, the deployed copy or the screen open in the designer), see what was added, removed or changed, list every change with the ones that alter a command flagged, and step through them. Read-only. - [Put alarms on a screen and choose their colours](https://eaxware.com/docs/eaxscada/how-to/configure-alarm-objects.md): Add the alarm banner, the standing alarms summary, the alarm history, counters and the annunciator panel to a screen, and set the colours, blink and sound of each alarm class and priority in the alarm classes editor. - [Connect a device to an eaxTag](https://eaxware.com/docs/eaxscada/how-to/connect-a-device-to-an-eaxtag.md): Connect a device to an eaxTag, such as a measured value a template brings, by handing it over to a driver mapping so the device becomes its source, and give it back with Return to local tag - the Studio steps, the 409 OWNED_BY_LOCAL_TAG answer and its plan, what blocks a handover, how writability is carried and never widened, the handed_over record, the two routes, the audit records, high availability and the known limits. - [Connect a MicroLogix, SLC 500 or PLC-5 on a serial port (DF1)](https://eaxware.com/docs/eaxscada/how-to/connect-a-df1-serial-controller.md): Read and write the data table of a Rockwell / Allen-Bradley MicroLogix 1000/1100/1200/1400/1500, SLC 5/03, 5/04, 5/05 or PLC-5 through its serial port (channel 0) with DF1 full-duplex - the controller's port setup, the line and station settings and their defaults, how writes are sent and confirmed, the link diagnostics, and what is not supported. - [Connect an eaxsim host to eaxScada's broker](https://eaxware.com/docs/eaxscada/how-to/connect-an-eaxsim-host.md): Give the UNS prefix guard of an eaxsim host a read-only watcher identity on eaxScada's NATS broker (--nats-watcher), so the simulated PLCs' UNS telemetry and commands are not refused. - [Connect Claude or another MCP client to eaxScada](https://eaxware.com/docs/eaxscada/how-to/connect-an-mcp-client.md): Give an external AI assistant (Claude Code, Claude Desktop, or any client that speaks the Model Context Protocol over HTTP) a dedicated account and an API token, connect it to the eaxScada MCP endpoint, and know what it can and cannot do. - [Connect objects with pipes and lines](https://eaxware.com/docs/eaxscada/how-to/connect-objects-with-pipes-and-lines.md): Draw pipes and lines that stay glued to the objects they join - drag them out of an object's "+" handles or draw them with the Pipe and Line tools, snap them to ports, choose orthogonal, straight or curved routes, and let them follow when objects move, turn or resize. - [Connect serial and CAN devices](https://eaxware.com/docs/eaxscada/how-to/connect-serial-and-can-devices.md): Poll Modbus RTU and ASCII devices on RS-485/RS-232 lines (directly or through a serial device server) and CANopen or raw CAN devices, with multi-drop addressing, line timing, quality and link diagnostics, and Modbus block reads on every Modbus channel. - [Connect to a Logix controller](https://eaxware.com/docs/eaxscada/how-to/connect-to-a-logix-controller.md): Read and write tags of a Rockwell / Allen-Bradley ControlLogix, CompactLogix or Micro800 over EtherNet/IP - what is supported and what is not (MicroLogix, SLC 500, PLC-5, implicit I/O; drives and other EtherNet/IP devices have their own connection kind), slot, route and the no-backplane Micro800 connection, External Access, tag addresses and the live tag browse. - [Connect to a MicroLogix, SLC 500 or PLC-5](https://eaxware.com/docs/eaxscada/how-to/connect-to-a-micrologix-slc-or-plc-5.md): Read and write the data table of a Rockwell / Allen-Bradley MicroLogix 1100/1400, SLC 5/05 or PLC-5 Ethernet controller over EtherNet/IP (PCCC) - the controller families, data-table addresses (N7:0, F8:3, B3:0/5, T4:2.ACC, C5:0.PRE, S:1, I:1.0/3, PLC-5 octal I/O, L9:0), the data types, batched reads, errors in words, and how writes are checked, sent and confirmed. - [Connect to Mitsubishi Electric MELSEC iQ-R, iQ-F, Q and L controllers (MC protocol / SLMP)](https://eaxware.com/docs/eaxscada/how-to/connect-to-a-mitsubishi-mc-protocol-controller.md): Read and write the devices of a Mitsubishi Electric MELSEC iQ-R, iQ-F (FX5U, FX5UC, FX5UJ), Q (built-in Ethernet) or L controller over MC protocol / SLMP, binary 3E or 4E frames over TCP or UDP - the controller-side setup (the port opened for SLMP, binary code, writing during RUN), the connection settings and route with their ranges, device addresses (D100, D100.5, D100:20, M10, X1F, X17 octal on iQ-F), data types including String text, the per-device scan rate, link diagnostics and the limits. - [Connect to an EtherNet/IP device](https://eaxware.com/docs/eaxscada/how-to/connect-to-an-ethernet-ip-device.md): Read and write a drive, a remote I/O adapter or another EtherNet/IP device that is not a Logix controller - CIP attributes by class, instance and attribute (@0x2A/1/8), the CIP types, batched reads, the device's identity, error statuses in words, and how writes are checked and confirmed. - [Connect to Omron CJ2, CS1, CP1 and NJ/NX controllers (FINS)](https://eaxware.com/docs/eaxscada/how-to/connect-to-an-omron-fins-controller.md): Read and write the memory areas of an Omron CJ2M, CJ2H, CS1, CP1E, CP1L, CP1H or NJ/NX controller over FINS/UDP or FINS/TCP (port 9600) - the controller-side setup (FINS node, address conversion, write protection, NJ/NX memory for CJ-series units), the connection settings and their ranges, addresses (D100, D100.05, CIO 0.00, W10.03, E0_100, T12, D200[10]), data types including STRING text, the per-device scan rate, link diagnostics and the limits. - [Connect to an S7 PLC](https://eaxware.com/docs/eaxscada/how-to/connect-to-an-s7-plc.md): Read and write a Siemens S7-300, S7-400, S7-1200 or S7-1500 over ISO-on-TCP (port 102) - what is supported, the PLC-side setup (PUT/GET, data blocks without optimized access, access level), rack and slot, S7 addresses, and importing the symbol table for tag names. - [Create a report dataset](https://eaxware.com/docs/eaxscada/how-to/create-a-report-dataset.md): Write the read-only query a report reads - choose the historian or the alarms, set the tag scope, declare the parameters and their defaults (today, yesterday, start_of_month(-1), now-24h), return the quality with each value, save through the server's checks and preview the rows as you. - [Deploy screens to operators, and live editing](https://eaxware.com/docs/eaxscada/how-to/deploy-screens-to-operators.md): Decide per project whether a screen save reaches the operators at once (live editing) or only when you click Deploy, see which changes operators do not have yet, and know which checks every deploy runs. - [Design a report](https://eaxware.com/docs/eaxscada/how-to/design-a-report.md): Create a report template in the screen designer's report mode - paper and margins, the page header and footer with page fields, the datasets and their bindings to the report's parameters, text, KPI tiles, tables with groups and subtotals, charts and repeat groups - preview it with real rows, render a PDF draft, then deploy it so that users can run it. - [Draw pipes in 3D](https://eaxware.com/docs/eaxscada/how-to/draw-pipes-in-3d.md): Draw pipe runs in the 3D designer with the Pipe tool - square to the plant, snapped to equipment nozzles, with bends drawn for you - then edit their route, size, finish and insulation, insert valves and instruments on them and bind their flow and status to tags. - [Edit screens: groups, clipboard, undo, and on a phone or tablet](https://eaxware.com/docs/eaxscada/how-to/edit-screens.md): Copy, cut, paste and duplicate objects between screens and studio tabs, paste with tag prefixes replaced, group and nest objects, undo or redo any change and jump to any step in the History panel, edit several objects at once, bind a tag by dropping it on an object, test pushbuttons with Alt+click, and edit screens on a phone or a tablet with touch gestures, where a tap never runs a command. - [Enforce interlocks on the server](https://eaxware.com/docs/eaxscada/how-to/enforce-interlocks.md): Give a command button an interlock that the eaxScada server enforces for every writer, check the "Enforced by the server" badge, choose what a Bad value does, and verify that a direct API write is refused while the interlock is active and that STOP always works. - [Enter downtime reasons](https://eaxware.com/docs/eaxscada/how-to/enter-downtime-reasons.md): For operators and supervisors (Pro and Enterprise) - open the Downtime panel of the operator runtime (toolbar button or a screen's Open downtime panel action), read the current state and the shift OEE, find the stops without a reason, set, change or clear a reason, sign a change after the shift closed, read a stop's history, and add the panel to a screen button. - [Place equipment drawings and import SVG files](https://eaxware.com/docs/eaxscada/how-to/equipment-drawings-and-svg-import.md): Use the Assets tab of the 2D screen designer to place equipment drawings in the Simple or Detailed style, colour them by a state tag, and import your own SVG drawings into the project. - [Export analytics results (CSV, Excel, Parquet)](https://eaxware.com/docs/eaxscada/how-to/export-analytics-results.md): Export the whole result of an Analytics query, or a saved dataset, as a CSV, Excel or Parquet file written by the server with your read rights - the Export split button, the dataset Export action, the status line with Download and Remove, the limits that refuse an export rather than cut it, how long files are kept, who may export, the audit record and the HTTP routes. - [Export genealogy for analytics tools](https://eaxware.com/docs/eaxscada/how-to/export-genealogy-for-analytics-tools.md): Switch on the incremental Parquet export of the genealogy (Hive folder layout by table and date) for analytics tools, read its watermark and the as_of_seq state of each row, manage the folder's access and retention yourself (it is not encrypted and outside the purge), and check the chain links from the files. - [Find and replace across screens](https://eaxware.com/docs/eaxscada/how-to/find-and-replace.md): Replace tag paths, texts, expressions or any property in the selection, the screen, a folder or the whole project - preview every change in a grid first, confirm the changes that touch commands or interlocks, undo on the open screen, and roll back other screens from their history. - [Find where a tag, screen or alarm is used](https://eaxware.com/docs/eaxscada/how-to/find-where-used.md): See every display, dashboard, alarm, recipe, script and driver mapping that uses a tag, a display or an alarm, get a warning before deleting something in use, and check the project for broken references. - [Fonts and text styles](https://eaxware.com/docs/eaxscada/how-to/fonts-and-text-styles.md): Choose fonts that look the same on every operator screen, upload your own font files to the project, and define named text styles (Title, Label, Value, Button...) that every object can use. - [Format text on a screen](https://eaxware.com/docs/eaxscada/how-to/format-text-on-a-screen.md): Set a Text object's font, colour, outline and shadow, put it in a fixed box with alignment, padding, wrapping, ellipsis or shrink to fit, background and border, and format a live value with unit, decimals, prefix, suffix, thousands separator and its own colours for bad and uncertain values. - [Genealogy retention, purge and archives](https://eaxware.com/docs/eaxscada/how-to/genealogy-retention-purge-and-archives.md): Set how long each unit type's genealogy records are kept (at least 365 days, forever by default), plan a purge with a dry run, run the signed purge on site on the primary, and keep, list, download, restore and verify the encrypted purge archives with the recovery key. - [Grant report rights](https://eaxware.com/docs/eaxscada/how-to/grant-report-rights.md): Give roles the eight Analytics and Reports rights (reports_view, reports_design, datasets_edit, reports_schedule, reports_distribute_external, reports_sign, analytics, reports_admin) with feature rules - the defaults of a new installation, what to grant after an upgrade (only the Administrator holds them until then), DENY rules, the AI co-pilot's ceiling, API tokens and remote access. - [Grant the right to write screen scripts](https://eaxware.com/docs/eaxscada/how-to/grant-the-screen-script-right.md): The right screens.script - who holds it (Administrator, Lead_Engineer and any role of level 80 or more; never the AI co-pilot), how to take it away with a DENY rule (the Administrator included), which saves need it (adding or changing script text on every save path) and which do not (moving, restyling, renaming, removing a script), what a refused save looks like, and its audit record. - [Import the CSV history into the store](https://eaxware.com/docs/eaxscada/how-to/import-csv-history-into-the-store.md): Move the CSV day partitions of an upgraded install into the historian's columnar store, from System Health (an administrator signs the plan) or offline with eaxscada historian-migrate-csv, each day verified before its CSV files are deleted. - [Install eaxScada as an app](https://eaxware.com/docs/eaxscada/how-to/install-eaxscada-as-an-app.md): Install the eaxScada web client as an app on phones, tablets, panel PCs and desktops - its own window and icon, opening on the operator runtime - and what the app keeps on the device (no live values, no commands). - [Build an isometric screen](https://eaxware.com/docs/eaxscada/how-to/isometric-screens.md): Draw a plant map on a tile grid with equipment blocks and pipes, bind it to tags and commands, and give operators a map they can turn, a phone view and a keyboard path - an isometric (2.5D) screen. - [Keep the historian within its disk budget](https://eaxware.com/docs/eaxscada/how-to/keep-historian-within-disk-budget.md): Set how long history is kept, cap the historian's size, get warned before the disk fills up, export closed days to Parquet, and watch the PC's resources in System Health. - [Let the AI assistant check a deploy](https://eaxware.com/docs/eaxscada/how-to/let-the-assistant-check-a-deploy.md): Ask the AI assistant for an advisory review of a project deploy - what it reads, its findings as comments marked AI · advisory, confirming them when you approve - and optionally make the deploy wait until the assistant's check has run on exactly the manifest deployed. The assistant never approves. - [Limit tag writes](https://eaxware.com/docs/eaxscada/how-to/limit-tag-writes.md): Set the values a tag accepts - a write range on the tag (minimum, maximum, step, allowed values, or text length and allowed texts), limits on the screen's inputs and faceplates, limits bound to other tags - and know that the server refuses any other value from every writer, and refuses writes to tags that do not exist. - [Manage dashboards](https://eaxware.com/docs/eaxscada/how-to/manage-dashboards.md): Create, open, rename, duplicate and delete dashboards, know what the server refuses (a dashboard in use, a change made from an old copy), and add cards; dashboards are deployed with the project. - [Keep accounts and audit trails in order](https://eaxware.com/docs/eaxscada/how-to/manage-security.md): Act on the warnings Security shows on its grid rows (published default passwords, duplicate usernames, locked accounts, roles limited to an old example area), read and verify the Access audit and the Operations audit, manage API tokens, and recover the administrator account. - [Migrate screen scripts to the sandbox](https://eaxware.com/docs/eaxscada/how-to/migrate-screen-scripts-to-the-sandbox.md): After the upgrade every screen script runs in a sandbox - no page, no player, no this, every system call a Promise. Find the scripts that use the page with the Problems panel, rewrite them with the system API and await (before and after examples), see what the operator sees when a script is refused or stopped, and, as a stop-gap only, turn on legacy screen scripts for a project. - [Move alarm definitions to Pro or Enterprise](https://eaxware.com/docs/eaxscada/how-to/move-alarms-to-pro.md): What happens to your alarm definitions when a Free or Starter installation moves to a Pro or Enterprise build - the one-time, validated import of alarm_definitions.json into the alarm database, what is and is not carried over, when the server refuses to start, and how to check the result. - [Popups, docks and navigation](https://eaxware.com/docs/eaxscada/how-to/popups-docks-and-navigation.md): Open a faceplate as a popup with a parameter set, open and close docks, give operators Back, Forward and Home, a home screen per role, breadcrumbs and multi-window consoles - and know what the runtime refuses. - [Record planned stops, adjust counts and recompute OEE](https://eaxware.com/docs/eaxscada/how-to/recompute-oee-and-record-planned-stops.md): For supervisors and engineers (Pro and Enterprise) - record, change and remove planned stops, move units from good to reject with a count adjustment, recompute machines from a time after late data or a configuration change (preview first, the reason, the confirmation before an HA takeover point, the progress and the history of requests), and review the reasons a recompute detached. - [Record lots and measured amounts in batch records](https://eaxware.com/docs/eaxscada/how-to/record-lots-and-measured-amounts.md): Set which recipe ingredients are lot tracked, the lot pattern each lot must match and the actual tag that measures the amount dosed, so a batch record holds only lots people entered and amounts the plant measured. Also who holds the recipe and batch rights, what the audit trail records first, how each batch record's integrity is checked, and what release signatures and recipe approvals are bound to. - [Recover the administrator account](https://eaxware.com/docs/eaxscada/how-to/recover-administrator-account.md): Give an administrator account a new password from the server's command line when nobody can sign in, with eaxScada stopped. Only someone with access to the server's data directory can do it. - [Require an e-signature to deploy](https://eaxware.com/docs/eaxscada/how-to/require-e-signature-to-deploy.md): Make every deploy of a project carry the deployer's electronic signature over exactly the manifest it publishes - the project setting, its defaults, signing in the Deploy dialog, live editing, turning it off with an engineer's signature, the API, the refusal codes and the journal events. - [Restrict a screen to a role level](https://eaxware.com/docs/eaxscada/how-to/restrict-screens-by-access-level.md): Set a screen's Required Access Level so that only users at or above a role level open it in the operator runtime and send its commands - what lower users see, how writes, the Studio, popups and the AI assistant follow the level, and the Problems panel warnings. - [Reusable screens with parameters](https://eaxware.com/docs/eaxscada/how-to/reusable-screens-with-parameters.md): Draw one faceplate screen for twenty pump stations - declare its parameters, import the stations from a spreadsheet as parameter sets, give each station a navigation button - with the server enforcing each station's confirmation, interlocks and limits on that station's own tags. - [Review screens and PLC programs before deploy](https://eaxware.com/docs/eaxscada/how-to/review-before-deploy.md): Comment on screen elements, tags and PLC program lines, request a review of what a deploy would publish, approve it with an electronic signature, and require approved reviews before any deploy. - [Review what a deploy changes](https://eaxware.com/docs/eaxscada/how-to/review-what-a-deploy-changes.md): Before operators get a deploy, see what it changes - the screens, the command targets added, removed or changed, the screen scripts, the write policy and the screen checks - open Compare on a changed screen, and acknowledge command changes with a reason. What a refusal means, how live editing is recorded, and how API clients and scripts send the acknowledgement. - [Run a report and download the files](https://eaxware.com/docs/eaxscada/how-to/run-a-report.md): Run a deployed report for a day or other parameters, follow it in the Runs tab, download the PDF and the Excel workbook (checked against their SHA-256 hash), read the warnings (hidden tags, simulated values, rows cut), cancel a run, and start a run over the HTTP API. - [Schedule a report](https://eaxware.com/docs/eaxscada/how-to/schedule-a-report.md): Run a deployed report on its own - at a time (daily, weekly, monthly, hourly or a cron expression), at the end of each shift, when a batch ends, when a tag turns on or after each shift handover (Enterprise) - as its owner, with deliveries, the catch-up rule after downtime, turning it on and off, Run now, restored schedules, the schedules' alarm, and the same steps over the HTTP API. - [Script a screen](https://eaxware.com/docs/eaxscada/how-to/script-a-screen.md): Write a Run script action and a screen startup script with the system API - read and subscribe to tags, write through the guarded path, open a popup with a parameter set, export a CSV, save a shift report to a server folder - in the shared code editor, with the sandbox scripts run in, the right to write them and what the server still checks. - [Search reviews and comments](https://eaxware.com/docs/eaxscada/how-to/search-reviews-and-comments.md): Find past reviews, signed decisions, comments and the AI assistant's checks of a project or a PLC from the Studio - by words, kind, author and dates - and open the thread or the review. You only find what you may read. - [Set up a view-only station](https://eaxware.com/docs/eaxscada/how-to/set-up-a-view-only-station.md): Register a control-room wall or a line panel as a view-only station that shows the process with nobody signed in - pair it with a one-time code, choose its screens, narrow it to address ranges, show or hide alarms, allow Studio or not, pair it again, disable or delete it - and know what an operator does there to act. - [Set up OEE and downtime](https://eaxware.com/docs/eaxscada/how-to/set-up-oee-and-downtime.md): For engineers and administrators (Pro and Enterprise) - turn the module on (production.enabled), check the shift calendars, grant the seven production rights, add a machine in the Studio's Production tab (calendar, plan, the state from a state code map, PackML, conditions or the counter, two of total, good and reject, fault code and product, ideal cycle, micro-stop and gap limits), the reason codes, production plans with breaks and exceptions, ideal cycles per product, the settings, apply the historian logging the source tags need (preview, then apply), and check the first results. - [Set up e-mail and folder delivery](https://eaxware.com/docs/eaxscada/how-to/set-up-report-delivery.md): Let scheduled reports go out by e-mail (an SMTP server with STARTTLS, the password stored write-only in the server's secret store, base_url for the links, attachments, allowed domains for addresses outside eaxScada) and to folders on the server (reports.folders.allowed), add deliveries to a schedule, and read each recipient's outcome in the run. - [Set up shift logs](https://eaxware.com/docs/eaxscada/how-to/set-up-shift-logs.md): For engineers and administrators - what the shift log needs (Enterprise, the audit trail, sign-in, a shift calendar), grant the five shift log rights, add a log per line or area in the Studio with its shift calendar, who may read, write, sign and review it, its entry types, the password signature of notes and of maintenance, the fields of each type, the handover settings (required, grace, sign-out window, co-sign at the console, minimum level), disable a log instead of deleting it, and add the signed shift report after each handover. - [Set up touch panels and kiosks](https://eaxware.com/docs/eaxscada/how-to/set-up-touch-panels.md): Turn on the on-screen numeric keypad and keyboard for panel PCs and kiosks - for the project, a screen or one object - choose the layouts, key size and position, show it on the sign-in page, and know how touch input is protected against swipes and pinches. - [Show bad and stale values](https://eaxware.com/docs/eaxscada/how-to/show-bad-and-stale-values.md): How screen objects mark a value that is Bad, not readable, Uncertain or stale - a red x, a blue lock, an amber question mark, a dashed outline - how gauges show it on their face (BAD QUALITY, NOT READABLE with a padlock), how to choose the project's quality style, and what colour conditions, interlocks and moving objects do with a value that cannot be trusted. - [Sign a report (review and approve)](https://eaxware.com/docs/eaxscada/how-to/sign-a-report.md): Give a report template a Part 11 signature plan (review, or review then approval, with the roles and meanings of each step and the separation-of-duties rules), then review and approve archived runs with an e-signature, download the signed copy with its signature manifestation page, read the refusals, and sign over the HTTP API. - [Style object states and "why disabled" tooltips](https://eaxware.com/docs/eaxscada/how-to/style-object-states.md): Choose how buttons, inputs, toggles and selectors look when they are disabled, locked, pressed, on, Bad or not configured - once for the whole project, or per object - preview each state in the designer, and let the tooltip tell the operator why a command is disabled. - [Trace, recall and export genealogy](https://eaxware.com/docs/eaxscada/how-to/trace-recall-and-export-genealogy.md): Find a part or a lot by its ID or the beginning of it, read its unit page, trace backward to what went into it and forward to where it went, find every unit a suspect lot reached, and export or print the result as CSV, JSON lines or a printed report. - [Translate your project](https://eaxware.com/docs/eaxscada/how-to/translate-your-project.md): Show your operator screens in several languages. Add the project's languages, turn the texts of existing screens into translation keys in one step, translate them in the Translations table or with your translators' spreadsheet, and let each operator choose a language in the runtime. - [Upgrading a high-availability pair](https://eaxware.com/docs/eaxscada/how-to/upgrade-ha-pair.md): Upgrade every node of an eaxScada high-availability cluster (primary, standby and witness) together, because builds from commit 6ac5700 onward keep the HA state where older builds cannot see it. - [Use the operator runtime on a phone](https://eaxware.com/docs/eaxscada/how-to/use-runtime-on-a-phone.md): Check values, open faceplates, send commands and acknowledge alarms from a phone, and choose how each screen opens there. - [Use server files from screens](https://eaxware.com/docs/eaxscada/how-to/use-server-files.md): Give screens a named folder on the server (a root) for reports, recipes or exports - which operations it allows, which roles may use each, which file types, the size limit and quota - then read and write it from a screen script, with every call checked and audited. - [Give objects a shared look with style classes](https://eaxware.com/docs/eaxscada/how-to/use-style-classes.md): Define named looks (fill, border, width, dash, corners, opacity, shadow, font, text colour) once in the project, give them to objects, override a value on one object, create a class from an object, rename or delete a class safely, and see where a class is used. A class only changes how objects look. - [Allow the AI assistant in a project](https://eaxware.com/docs/eaxscada/how-to/use-the-ai-assistant.md): Add an AI provider (a cloud service or a model on your own network), allow it in the project where the assistant may be used, give the assistant the project's context, and know what plant data leaves the site and what the server refuses. - [Trend tags in the studio](https://eaxware.com/docs/eaxscada/how-to/use-trends.md): Add pens to a trend, pick the time range, zoom, and switch between the chart, the grid of recorded values and both side by side (Chart | Values | Split), with bad and uncertain samples shown as such and PNG or CSV export. - [Verify and purge the report archive](https://eaxware.com/docs/eaxscada/how-to/verify-and-purge-the-report-archive.md): Check that archived report files are as they were written (Verify recomputes the SHA-256 of the original, its run record and every signed copy), find runs in the Archive tab (dates in UTC), read the archive after a downgrade or on an HA standby, keep the archive within its quota and disk floor, and delete the runs past their retention with a dry run and an e-signature over the plan; signed runs are never purged. - [When the audit trail is down](https://eaxware.com/docs/eaxscada/how-to/when-the-audit-trail-is-down.md): The system alarm ALM-SYS-AUDIT-DOWN is active and actions that must be recorded first are refused with 503 AUDIT_NOT_WRITTEN. Find the cause (a network share, a RAM disk, less than 10 GB free, a file held by another process, an encryption setting changed, a damaged audit.duckdb), fix it, repair a trail a checkpoint cut short (eaxscada audit-set-aside --repair, the chain continues, the original kept) or set a damaged trail aside offline with eaxscada audit-set-aside, e-signed. - [When the historian store file does not open](https://eaxware.com/docs/eaxscada/how-to/when-the-historian-store-file-does-not-open.md): The historian's store file did not open at start. Tell a locked file from a damaged one, repair a file a checkpoint cut short (checked on a copy, e-signed, the original kept, the history complete), or set a damaged file aside from System Health (an administrator signs it; the file is renamed, never deleted, and the points waiting go to a new store), then restore the history before it offline with historian-restore --snapshot --keep-current. - [Work on a screen with other engineers](https://eaxware.com/docs/eaxscada/how-to/work-on-a-screen-with-other-engineers.md): See who else has a screen open in the Studio (viewing, editing or idle), know who holds a screen's editing lock, open a screen read-only while someone else edits it, take over editing with a confirmation recorded in the audit trail, and keep or discard your own unsaved changes when someone takes over. - [Work with data tables](https://eaxware.com/docs/eaxscada/how-to/work-with-data-tables.md): Filter, sort and search the data tables of the eaxScada Studio and operator runtime, choose their columns with the Columns button (remembered per table in this browser, Reset, keyboard), and export the rows as CSV; which columns always show, which start hidden in a narrow window, and which a table shows only for some data or rights. - [Write in the shift log and hand over a shift](https://eaxware.com/docs/eaxscada/how-to/write-in-the-shift-log.md): For operators - open the shift log in the operator runtime, write notes, deviations, maintenance, safety items and instructions (also with "Add to shift log" from an alarm or a faceplate), sign the ones that need a password, correct, void, close and review entries, hand over a shift with a status line per open item, and take it over in your own session or co-sign at the same console; for shift log administrators, export a period as a ZIP file with its manifest; for every reader, verify an export against the audit trail. With the messages you may see and what to do. ## eaxScada: Reference - [Alarm classes, history and counts API](https://eaxware.com/docs/eaxscada/reference/alarm-classes-and-history.md): The project's alarm visual classes (colours, blink and sound per class, priority and ISA-18.2 state), the alarm history query with filters, sorting, paging and CSV export, and the alarm counts for counters and annunciators. - [Analytics and Reports reference](https://eaxware.com/docs/eaxscada/reference/analytics-and-reports.md): The facts of Analytics and Reports in one place - the relations and columns of each dataset family, the quality helpers, parameter types and the defaults vocabulary, the limits per kind of run, the report template's elements, placeholders, page fields and formats, the eight rights, the run record and statuses, the result hash, schedules and their triggers (cron, shift calendars, batch, tag), signature plans and signatures, the archive (retention, Verify statuses, purge), delivery outcomes and rules, HA replication, what stays open after a downgrade, the analytics workspace's routes and limits, the audit events, ALM-SYS-REPORTS, the HTTP routes and the configuration keys. - [Audit trail API](https://eaxware.com/docs/eaxscada/reference/audit-trail-api.md): GET /api/audit (the audit trail's records, newest first, paged with the X-Audit-Next-Before cursor and filtered by category, action, user, resource, origin and time) and GET /api/audit/verify (the chain check), the 403 NO_AUDIT_TRAIL, 503 AUDIT_NOT_WRITTEN, 400 and 500 answers, the trail's state (X-Audit-Trail-Mode, audit_trail in /api/system/health, /api/system/info and /api/licence), and the audit trail's own record actions (AUDIT_TRAIL_STARTED, AUDIT_TRAIL_RESUMED, AUDIT_STORAGE_WARNING, LEDGER_TIP_MISMATCH, LEDGER_COMMIT_UNCONFIRMED, LEDGER_FILE_SET_ASIDE, LEDGER_FILE_REPAIRED, AUDIT_TRAIL_RESTORED). - [Custom chart](https://eaxware.com/docs/eaxscada/reference/custom-chart.md): The custom chart dashboard card - a script or an option JSON with placeholders, drawn from the card's own queries in an isolated sandbox with no network and no tags; what the code receives, the limits, the CUSTOM mark and the dashboards.code right. - [Dashboard cards](https://eaxware.com/docs/eaxscada/reference/dashboard-cards.md): The dashboard cards of eaxScada - Time series, State timeline, Stat, Gauge, Bar gauge, Table, Alarm list, Bar / pie, Pareto, Text and Custom chart - what each shows, its data sources, options, quality rules and export, and the dashboard time range, refresh and variables they share. - [Deploy preview API](https://eaxware.com/docs/eaxscada/reference/deploy-preview-api.md): GET /api/dev/projects/{id}/deploy-preview (what a deploy would change - screens, command targets, scripts, write policy, lint - and its preview_hash), the ack a deploy must carry when it changes command targets, scripts or the write policy, the 409 and 403 refusal codes, and the DEPLOY, DEPLOY_PREVIEW_REFUSED and DEPLOY_AUTO_PREVIEW audit records. - [Design reviews API](https://eaxware.com/docs/eaxscada/reference/design-reviews-api.md): Comments anchored on screen elements, ST lines and tags; review requests with a diff; signed approvals; and the approve-before-deploy site policy that refuses a deploy unless an approved review signed exactly the manifest it publishes. - [eaxTags local tags](https://eaxware.com/docs/eaxscada/reference/eaxtags-local-tags.md): The local tags of eaxScada (eaxTags) - the Studio's tag list with its actions and More menu, the New local tag defaults, every member of a tag definition with its rules (no_initial, the template marker, writable, simulated, write_range, esign_external), tags fed by an eaxPLC that stops reporting, the quality of tags fed by a script on eaxScada, a driver mapping on a local tag's path, and the tag, export, import and history API. - [eaxTags script reference](https://eaxware.com/docs/eaxscada/reference/eaxtags-scripts.md): How an eaxTags script runs on eaxScada or pinned to an eaxPLC runtime - its lifecycle (save, dry run, period, time limit, kept state, HA standby), what it can read and write, the globals and functions (tick, dt, t, now, node, tags.get, tags.set and its options, tags.setBad, tags.quality, sim, console.log, genealogy), the quality of the values a script writes, and the errors the Studio shows. - [Expression language](https://eaxware.com/docs/eaxscada/reference/expression-language.md): Tag reference syntaxes, expressions, transform pipelines, visual conditioning modes and the server-side scripting globals of eaxScada. - [Genealogy API](https://eaxware.com/docs/eaxscada/reference/genealogy-api.md): What the generated route list does not say about the part and lot genealogy routes of eaxScada - remote-access class, behaviour after a licence downgrade, parameters, request bodies and answers - with the signed-request rules and the WebSocket messages. - [3D catalog](https://eaxware.com/docs/eaxscada/reference/generated/3d-catalog.md): The equipment and primitive items of the 3D digital-twin studio and the scene node kind each one creates. - [Command-line flags](https://eaxware.com/docs/eaxscada/reference/generated/cli.md): Every command-line flag of the eaxScada binaries, with type, default and description. - [Alarm definitions and events](https://eaxware.com/docs/eaxscada/reference/generated/config/alarms.md): Alarm definitions and events: every key, its type and meaning, generated from the Go structs that decode it. - [Driver channels, devices and tags](https://eaxware.com/docs/eaxscada/reference/generated/config/drivers.md): Driver channels, devices and tags: every key, its type and meaning, generated from the Go structs that decode it. - [Screen document](https://eaxware.com/docs/eaxscada/reference/generated/config/screen-document.md): Screen document: every key, its type and meaning, generated from the Go structs that decode it. - [Server configuration](https://eaxware.com/docs/eaxscada/reference/generated/config/server-config.md): Server configuration: every key, its type and meaning, generated from the Go structs that decode it. - [HTTP API routes](https://eaxware.com/docs/eaxscada/reference/generated/http-api.md): Every HTTP route of the eaxScada server: methods, path and the role required to call it. - [Screen objects](https://eaxware.com/docs/eaxscada/reference/generated/widgets.md): Every object of the eaxScada screen designer and dashboard, grouped as in the palette, with a picture of each. - [Alarm objects](https://eaxware.com/docs/eaxscada/reference/generated/widgets/alarms.md): Screen objects: alarm objects. What each one is for, with a picture. - [Alarm annunciator](https://eaxware.com/docs/eaxscada/reference/generated/widgets/alarms/alarm-annunciator.md): The alarm annunciator screen object: a panel of counter tiles, one per alarm class and priority. - [Alarm banner](https://eaxware.com/docs/eaxscada/reference/generated/widgets/alarms/alarm-banner.md): The alarm banner screen object: the most urgent alarms on one to ten lines, coloured by alarm class, with acknowledge, details and silence. - [Alarm counter](https://eaxware.com/docs/eaxscada/reference/generated/widgets/alarms/alarm-counter.md): The alarm counter screen object: one tile counting the unacknowledged and total alarms of a class, priority and area. - [Alarm history](https://eaxware.com/docs/eaxscada/reference/generated/widgets/alarms/alarm-history.md): The alarm history screen object: the alarm journal on a table paged by the server, with time range, filters, presets and CSV export. - [Alarm summary](https://eaxware.com/docs/eaxscada/reference/generated/widgets/alarms/alarm-summary.md): The alarm summary screen object: the standing alarms on a live table, filtered by area, class and priority, with acknowledge and shelve. - [Component instances](https://eaxware.com/docs/eaxscada/reference/generated/widgets/components.md): Screen objects: component instances. What each one is for, with a picture. - [Component instance](https://eaxware.com/docs/eaxscada/reference/generated/widgets/components/component-instance.md): The component instance screen object: one use of a reusable component, with its parameters filled in for one piece of equipment. - [Buttons, indicators and faceplates](https://eaxware.com/docs/eaxscada/reference/generated/widgets/controls.md): Screen objects: buttons, indicators and faceplates. What each one is for, with a picture. - [Button](https://eaxware.com/docs/eaxscada/reference/generated/widgets/controls/button.md): The button screen object: a push button that writes a tag, runs a script or navigates, with confirmation, e-signature and interlocks. - [Faceplate](https://eaxware.com/docs/eaxscada/reference/generated/widgets/controls/faceplate.md): The ISA-101 faceplate screen object: PID controller, motor or valve faceplate with PV, setpoint, output, mode, state and interlock. - [Multistate indicator](https://eaxware.com/docs/eaxscada/reference/generated/widgets/controls/multistate-indicator.md): The multistate indicator screen object: a tile that changes colour, caption and icon with a tag's value, bit or bit mask. - [Dashboard cards](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards.md): The cards of a dashboard grid: what each one shows, with a picture. - [Alarm summary card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-alarm-summary.md): The alarm summary dashboard card: the active alarms with their priority badges and an acknowledge button. - [Batch reactor card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-batch-reactor.md): The batch reactor dashboard card: a reactor synoptic with level, temperature, pressure, agitator, valves and batch buttons. - [Centrifugal pump card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-centrifugal-pump.md): The centrifugal pump dashboard card: a pump with its running state, flow, speed and discharge pressure, and a start / stop button. - [Custom card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-custom.md): The custom dashboard card: your own HTML, SVG, CSS and JavaScript, run in a sandbox with live tag values. - [Display card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-display.md): The display dashboard card: one of your screens running live inside a card, scaled to fit. - [Gauge card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-gauge.md): The gauge dashboard card: progress arc, ring, zoned dial, PV / SP / OUT dial, level bar or bullet with target, on the gauge engine. - [KPI card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-kpi.md): The KPI dashboard card: one live value, large, with its unit, quality, change over a time window and an optional target. - [PID controller card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-pid-controller.md): The PID controller dashboard card: PV, setpoint and output bars, MAN / AUTO / CAS mode buttons and a setpoint field. - [Push button card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-push-button.md): The push button dashboard card: a button that writes 1 to its output tag when pressed, through the guarded write path. - [Radial gauge card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-radial-gauge.md): The radial gauge dashboard card: a dial filling the card, grey when normal, alarm bands from the tag's limits, bad quality hatched. - [Sparkline card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-sparkline.md): The sparkline dashboard card: the current value over a small trend of the last minutes, with limit lines. - [Storage tank card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-storage-tank.md): The storage tank dashboard card: a tank with its live level, volume and temperature, and display limit lines. - [Trend card](https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-trend.md): The trend dashboard card: up to four pens over a time window from 30 seconds to 24 hours, filled from the historian. - [Trends, tables and dashboards](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data.md): Screen objects: trends, tables and dashboards. What each one is for, with a picture. - [Audit trail](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/audit-trail.md): The audit trail screen object: the server's audit trail of operator actions, on a live table with filters and CSV export. - [Dashboard grid](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/dashboard-grid.md): The dashboard grid screen object: a grid of dashboard cards (values, gauges, trends, faceplates, alarms) inside a screen. - [Data table](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/data-table.md): The data table screen object: a live table of tags, alarms, recipe parameters or the audit trail, with filters, sorting and CSV export. - [Recipe manager](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/recipe-manager.md): The recipe manager screen object: a placeholder that is not connected to recipes, no longer in the palette; run batches from Recipes & Batches in the studio. - [Record table](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/record-table.md): The record table screen object: a fixed list of records in the data grid, where choosing a row writes that row's value to a tag. - [Trend chart](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/trend-chart.md): The trend chart screen object: live multi-pen trends with history backfill, time zoom, quality shown, and PNG and CSV export. - [Trend with values](https://eaxware.com/docs/eaxscada/reference/generated/widgets/data/trend-values.md): The trend with values screen object: a trend and the table of its samples in one container, with Chart, Values and Split tabs. - [Embedded content](https://eaxware.com/docs/eaxscada/reference/generated/widgets/embedded.md): Screen objects: embedded content. What each one is for, with a picture. - [3D view](https://eaxware.com/docs/eaxscada/reference/generated/widgets/embedded/3d-view.md): The 3D view screen object: a 3D reactor model in a 2D screen, its agitator turned by a speed or running tag and its contents coloured by a value. - [Map](https://eaxware.com/docs/eaxscada/reference/generated/widgets/embedded/map.md): The map screen object: a map with markers that show live tag values, for sites, pumping stations and fleets, on the project's own tile source. - [3D scene view](https://eaxware.com/docs/eaxscada/reference/generated/widgets/embedded/scene-3d-view.md): The 3D scene view screen object: a 3D scene of the project drawn inside a 2D screen, its equipment moved by live tags. - [Video](https://eaxware.com/docs/eaxscada/reference/generated/widgets/embedded/video.md): The video screen object: a video file or a browser-playable camera stream shown in a screen, with autoplay, mute, loop and controls. - [Web content](https://eaxware.com/docs/eaxscada/reference/generated/widgets/embedded/web-content.md): The web content screen object: your own HTML, with live tag values, or another web page, each in a sandboxed frame inside a screen. - [Process equipment and P&ID symbols](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment.md): Screen objects: process equipment and p&id symbols. What each one is for, with a picture. - [Batch reactor](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/batch-reactor.md): The batch reactor screen object: a jacketed reactor vessel with a live liquid level and an operator faceplate. - [Centrifugal pump](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/centrifugal-pump.md): The centrifugal pump screen object: a pump drawing coloured by its running or fault state, with an operator faceplate. - [Control valve](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/control-valve.md): The control valve screen object: a valve drawing coloured by its state or opening, with an operator faceplate. - [Conveyor](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/conveyor.md): The conveyor screen object: a belt conveyor drawing for material handling screens, coloured by a condition. - [Drive motor](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/drive-motor.md): The drive motor screen object: an electric motor drawing coloured by its running or fault state, with an operator faceplate. - [Equipment drawing](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/equipment-drawing.md): The equipment drawing screen object: 35 drawings of the Assets tab (pumps, valves, vessels, heat transfer, conveyors, motors, instruments, piping) in a Simpl... - [Heat exchanger](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/heat-exchanger.md): The heat exchanger screen object: a shell-and-tube exchanger drawing with its name and an operator faceplate. - [ISA heat exchanger](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/isa-heat-exchanger.md): The ISA-5.1 heat exchanger screen object: shell and tube, plate and frame, air cooler, kettle and reboiler symbols. - [ISA instrument bubble](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/isa-instrument.md): The ISA-5.1 instrument bubble screen object: tag letters and loop number in the bubble shape of the instrument's location. - [ISA pump](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/isa-pump.md): The ISA-5.1 pump screen object: centrifugal, positive displacement and vacuum pump symbols, coloured by state. - [ISA valve](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/isa-valve.md): The ISA-5.1 valve screen object: eight valve bodies and four actuators, coloured by state, with an operator faceplate. - [ISA vessel](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/isa-vessel.md): The ISA-5.1 process vessel screen object: a P&ID vessel with a live liquid level and an operator faceplate. - [Process symbol](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/process-symbol.md): The process symbol screen object: one shape for a library of 47 P&ID symbols (vessels, pumps, compressors, heat transfer, material handling, electrical, pipi... - [Storage tank](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/storage-tank.md): The storage tank screen object: a vertical vessel with a live liquid level, readout and operator faceplate. - [Transmitter](https://eaxware.com/docs/eaxscada/reference/generated/widgets/equipment/transmitter.md): The transmitter screen object: a field instrument with a live readout, unit and quality, and an operator faceplate. - [Gauges](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges.md): Screen objects: gauges. What each one is for, with a picture. - [Classic dial gauge](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/classic-dial-gauge.md): The classic dial gauge screen object: the dial gauge of the equipment palette, kept for screens that use it. - [Deviation bar](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/deviation-bar.md): The deviation bar screen object: the value minus its setpoint or a fixed reference, centred at zero, grey within the tolerance, amber beyond it and red beyon... - [Gauge](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/gauge.md): The industrial gauge screen object: radial, arc, ring, zoned, multi-pointer, bar, bullet and sparkline gauges with alarm bands and quality. - [KPI star](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/kpi-star.md): The KPI star screen object: 3 to 8 values, each over its own range, drawn as a polygon over the grey polygon of their normal ranges; a value outside its norm... - [Mini-trend tile](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/mini-trend-tile.md): The mini-trend tile screen object: a label, the value with its unit and quality, and a small trend of the last minutes, for KPI rows and overview screens. - [Moving analog indicator](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/moving-analog-indicator.md): The moving analog indicator screen object: a scale with the normal operating band, the alarm limits, a pointer for the value and an optional setpoint marker.... - [Sparkline with limits](https://eaxware.com/docs/eaxscada/reference/generated/widgets/gauges/sparkline-with-limits.md): The sparkline with limits screen object: the last minutes of a tag with its limit lines, the normal band and the current value, filled from the historian whe... - [Legacy SVG assets](https://eaxware.com/docs/eaxscada/reference/generated/widgets/legacy.md): Screen objects: legacy svg assets. What each one is for, with a picture. - [Legacy SVG assets](https://eaxware.com/docs/eaxscada/reference/generated/widgets/legacy/legacy-svg-assets.md): Older SVG asset types (gate valve, centrifugal pump, cone tank, heat exchanger, AC motor, transmitter), still drawn for screens that use them. - [Operator inputs](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs.md): Screen objects: operator inputs. What each one is for, with a picture. - [Numeric entry](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs/numeric-entry.md): The numeric entry screen object: a setpoint field with the live value, limits enforced by the server, confirmation and the touch keypad. - [Selector](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs/selector.md): The selector screen object: a row of options (manual, auto, cascade...) that writes the value of the option the operator taps. - [Slider](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs/slider.md): The slider screen object: a setpoint chosen on a slider and sent with Set, within limits the server enforces. - [Spinner](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs/spinner.md): The spinner screen object: a stepper with minus and plus buttons for small setpoint changes, sent with Set. - [Text entry](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs/text-entry.md): The text entry screen object: text sent to a String tag (a batch name, a product code), with length limits and confirmation. - [Toggle switch](https://eaxware.com/docs/eaxscada/reference/generated/widgets/operator-inputs/toggle-switch.md): The toggle switch screen object: a two-state switch that shows the feedback and writes the other state when tapped. - [P&ID palette catalog](https://eaxware.com/docs/eaxscada/reference/generated/widgets/palette-catalog.md): The P&ID symbol palette: every item, its group, the shape type it places and the props it sets. - [Shapes and text](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes.md): Screen objects: shapes and text. What each one is for, with a picture. - [Arc](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/arc.md): The arc screen object: a part of a ring, for dial backgrounds and fixed scale segments drawn from a rotation and an angle. - [Circle](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/circle.md): The circle screen object: lamps, indicators and round symbols. Every property, bindings, conditions and an example. - [Curve](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/curve.md): The curve screen object: a smooth cubic curve with an optional glow, arrowheads and an animated flow, for signal and energy flows. - [Ellipse](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/ellipse.md): The ellipse screen object: oval shapes, vessel heads and round panels. Every property, bindings, conditions and an example. - [Group](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/group.md): The group screen object: several objects kept together, moved, copied and conditioned as one. - [Line](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/line.md): The line screen object: straight segments through a list of points, drawn with the line tool, for signal lines and leaders. - [Path](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/path.md): The path screen object: an outline written as SVG path data, with holes, made by combining shapes. - [Pipe](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/pipe.md): The pipe screen object: process piping through a list of joints, with a casing, a coloured core and a flow line. - [Polygon](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/polygon.md): The freeform polygon screen object: any outline from a list of points, for areas, buildings and custom equipment. - [Rectangle](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/rectangle.md): The rectangle screen object: a box for panels, frames, status tiles and backgrounds. Every property, bindings, conditions and examples. - [Regular polygon](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/regular-polygon.md): The regular polygon screen object: triangles, hexagons and any shape with equal sides, from 3 to 24 sides. - [Ring](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/ring.md): The ring screen object: a circle with a hole, for flanges, nozzles and round status indicators. - [Star](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/star.md): The star screen object: a star with any number of points, for highlights, markers and burst symbols. - [Text](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/text.md): The text screen object: titles, labels and live value readouts with unit and decimals, translatable and styled from the project. - [Wedge](https://eaxware.com/docs/eaxscada/reference/generated/widgets/shapes/wedge.md): The wedge screen object: a pie slice, for sector indicators, valve position marks and simple pie shapes. - [Historian CSV import API](https://eaxware.com/docs/eaxscada/reference/historian-csv-import-api.md): GET /api/historian/migration (the plan, the disk, the estimate, the state and the per-day results) and POST /api/historian/migration/sign, start, retry, pause and resume - the routes behind System Health's CSV history import, for a signed-in administrator only, with the historian_migrate e-signature, the 409 and 503 refusals and the HISTORIAN_MIGRATION_* audit records. - [Historian store API](https://eaxware.com/docs/eaxscada/reference/historian-store-api.md): GET /api/historian/store (the check of the store file, the last set-aside and the restore command) and POST /api/historian/store/sign and /set-aside - the routes behind System Health's "Set the store aside…", for a signed-in administrator only, with the historian_store_set_aside e-signature, the 409 and 503 refusals and the HISTORIAN_STORE_SET_ASIDE audit records; and POST /api/historian/store/repair/check, /repair/sign and /repair, the repair of a file a checkpoint cut short (HISTORIAN_STORE_REPAIRED). - [Live data socket (/ws)](https://eaxware.com/docs/eaxscada/reference/live-data-socket.md): The messages of the eaxScada live data WebSocket /ws - SUBSCRIBE (with append and remove for a page switch sent as a difference, and prefixes such as Plant/Line1/* for every readable tag under a path) and UNSUBSCRIBE from the browser, TAG_SNAPSHOT, TAG_UPDATES, SUBSCRIBE_REFUSED and the 5 s HEARTBEAT from the server, with every field, the rules of a view's tag set, the limits (64 KiB frames, 20 messages a second with a burst of 40, tags and views per socket, prefixes per view, the batch window), how the page finds a link that goes silent (down 20 to 24 s after its last frame) and reads a reopened socket up only at its first frame, and what was removed (TAG_INIT, TAG_UPDATE). - [Metrics, logs and System Health](https://eaxware.com/docs/eaxscada/reference/metrics.md): eaxScada's Prometheus metrics (GET /metrics), who may read them, the structured operational log with request ids and secret redaction, the optional syslog export, and the System Health history. - [OEE and downtime reference](https://eaxware.com/docs/eaxscada/reference/oee-and-downtime.md): The facts of OEE and downtime (Pro and Enterprise) in one place - the production config.yaml section with every key, default and range, the seven rights and their defaults, the HTTP routes under /api/production with methods, rights, API tokens, the per-machine read rule and the order of the refusals, error codes, the configuration documents and their limits, the dataset family production (relations, columns, helpers, the quality save rule), the open_downtime screen action, audit events, the system alarm and the metrics. - [Project settings](https://eaxware.com/docs/eaxscada/reference/project-settings.md): Every setting of an eaxScada project, section by section - the safety e-stop tag, the on-screen keyboard, the operator runtime (quality style, home screens, external addresses, deploy gate, live editing, the deploy e-signature, state styles), review before deploy, fonts and text styles, languages, pages and routes, and the Display Settings of each screen - with the default, who may change it, the edition and the safety notes. - [Runtime languages](https://eaxware.com/docs/eaxscada/reference/runtime-languages.md): Reference of eaxScada's languages - the translation key syntax, the order in which a text is chosen, placeholders and plurals, number and date formats, the operator's language choice, the translations API, the runtime bundles, the CSV format, translated alarm messages and the audit record of translated dialogs. - [Screen parameters](https://eaxware.com/docs/eaxscada/reference/screen-parameters.md): The {Name} syntax of screen parameters, the declaration (types, required, defaults, allowed values and folders), parameter sets, how screens, popups, docks and embedded screens are opened with them, the checks, and how the server enforces write targets with parameters. - [Screen scripting API](https://eaxware.com/docs/eaxscada/reference/screen-scripting-api.md): The system.* functions that screen scripts and Run script actions use - tags, navigation and popups, alarms, the shift log (Enterprise), user, local and server files, print and export, clipboard, notifications, timers - with the server check and the audit of each, and the popup, dock and navigation actions of screen objects. - [Server flags and configuration](https://eaxware.com/docs/eaxscada/reference/server-configuration.md): scada-server command-line flags, environment variables, the config.yaml file and the network ports eaxScada uses. - [Server files API](https://eaxware.com/docs/eaxscada/reference/server-files.md): Named server folders (roots) that screens may list, read and write through the server, with a role list per operation, file types, a file size limit, a quota and an audit record for every call. - [Session limits](https://eaxware.com/docs/eaxscada/reference/session-limits.md): The idle time and the session maximum of eaxScada sessions - the security defaults, the values per group, how the value that applies is chosen (shortest wins, the station's idle cap), what counts as activity, the countdown, the return to viewing only, tabs that follow each other - and the session, activity, session-policy and station routes with their answers and audit records. - [Shift log API](https://eaxware.com/docs/eaxscada/reference/shift-log-api.md): What the generated route list does not say about the eaxScada shift log routes (Enterprise only) - the order of the checks, the remote-access class, the behaviour on a read-only server, how a signature is prepared, ticketed and redeemed, the request bodies and answers of entries, corrections, closures, reviews and the handover, verification, the period export (ZIP layout, manifest, headers), the verification of an export against the audit trail (its checks and report), the settings document, the shift report starter, the error codes and the audit actions. - [Sign-in and profile API](https://eaxware.com/docs/eaxscada/reference/sign-in-and-profile-api.md): POST /api/auth/login, GET /api/auth/me and POST /api/auth/logout - the request, the answers, the session cookie and token, and what permissions null with permissions_error means. - [Studio presence API](https://eaxware.com/docs/eaxscada/reference/studio-presence-api.md): GET and POST /api/studio/presence (who is on the screens the caller may read, each screen's editing lock, a tab's heartbeat and notices), POST /api/studio/presence/lock, /takeover and /release, the rights each needs, the SCREEN_EDIT_TAKEOVER audit record, the STUDIO_PRESENCE_CHANGED signal and the refusal codes. - [Web content script API](https://eaxware.com/docs/eaxscada/reference/web-content-script-api.md): What the HTML of a web content object can use to show live values - data-tag elements, eax.on, eax.value, eax.tag and eax.scan - how its Tags list is subscribed, what the frame may and may not do, and its limits. - [What's new in eaxScada](https://eaxware.com/docs/eaxscada/whats-new.md): Everything added or fixed in eaxScada since 9 October 2026 - the editor (with who else is on a screen and the editing lock), the operator runtime, write safety, the AI assistant and MCP clients, security (screen access, signed deploys, the eaxPLC deploy gate, sandboxed screen scripts and the right to write them, the deploy preview and its acknowledgement), design reviews, the AI assistant as reviewer of a deploy and the search of reviews and comments, alarms, part and lot genealogy, Analytics and Reports, the signed shift log (Enterprise) with Add to shift log and its security review fixes, Modbus block reads, live values sent per view and batched, new screens held until their values are in, the historian's disk budget on the columnar store, MQTT messages limited to the tags their channel maps, the shift log period export, config.yaml keys named at start-up and read where their indentation puts them, page switches sent as a difference, modal popups that block the whole screen, charts, tables and web content that follow inner screens and docks, shift log signatures per type and fields set in the Studio, the verification of a shift log export against the audit trail, prefix subscriptions on /ws, a Columns button on every data table, remote requests refused by the remote-access check recorded in the audit trail, the control status in the operator's language, fewer needless HA failovers under load, the embedded broker's start wait, feature DENY rules on PLC control and server files, the feature rights list in the permission dialog, DuckDB 2.0 with database stores that reopen after a failed write and their System Health section, the historian heartbeat for logging rules and the default policy, Windows saves that wait for an antivirus scan, data tables fully in the operator's language, OEE and downtime (Pro and Enterprise, read only towards equipment), the historian telling a refused point from an outage, the Studio in its own language, the repair of a historian store or audit trail a checkpoint cut short, a historian write that hangs reported down after 30 s, Linux and Docker packages that give a stop 120 s, typed UDT defaults and UDT deletes on the server, batch records that said their integrity was not checked and are now checked against their own chain and the audit trail (with release signatures and recipe approvals bound to what they sign), a memory cap for every database store, dashboard commands in the operator's language, plural counts, the eaxCollab digest in the configured language, the eaxCollab inbox language kept per member, the new dashboard cards with their card picker, shared time range and variables and the sandboxed custom chart, alarm limits and shift ranges on dashboard cards, one reading of alarm priorities everywhere, dashboard dataset reads audited once per hour and shown to report viewers, alarm limits always in view on dashboard cards, System Health alarm counts for every priority name, the server's node id in eaxTags scripts, alarm counters in the Process plant template, starter templates without made-up readings and the no_initial local tag option, templates that skip 3D pages on editions without 3D, the offline commands that name the server as it names itself, eaxTags tag actions that fit in every language with a More menu, new local tags that are not simulated and have no value until written, the eaxTags tag and script reference pages, Hand over to driver and Return to local tag for a local tag a device now measures, a Studio top bar that never scrolls sideways, view-only stations, idle time and session maximum per group, the lockout per account and address, requests from another origin refused when a cookie authenticates them, text style colours on Text objects and the screen's background on the light Studio canvas, open NATS connections closed when their user's rights change, the lock for a value the account may not read on objects and gauges, gauges bound to an expression that show the quality of the tags it reads, dashboard cards that never show a failed query's previous values, dataset result hashes over the rows in any order, the result hash encoding recorded beside each hash, simulated driver channels marked simulated everywhere, one SIMULATED chip on a fully simulated screen, phone card lamps named by their own label, and the platform - with a link to each page, and the upgrade notes that list what now behaves differently. ## eaxScada: Explanation - [Alarms](https://eaxware.com/docs/eaxscada/explanation/alarms.md): How eaxScada implements the ANSI/ISA-18.2 alarm lifecycle, condition types and deadbands, acknowledgement, shelving and the Sequence of Events journal. - [Analytics and Reports](https://eaxware.com/docs/eaxscada/explanation/analytics-and-reports.md): What the Analytics and Reports module of eaxScada does - datasets, report templates, runs, schedules, delivery, Part 11 signatures, the archive, the analytics workspace with its exports, extracts across sources and server pivot - and the rules it keeps - a report or a query shows only what the person who runs it may read, bad and uncertain values are always marked, there is no write path, files are archived once with their SHA-256 hash and never changed, signed reports are never purged, archived reports stay readable after a downgrade - with the limits of each kind of run and how time zones, daylight-saving changes and high availability are handled. - [Choose an editor: 2D, 3D or isometric](https://eaxware.com/docs/eaxscada/explanation/choose-an-editor.md): What the 2D screen designer, the isometric map editor and the 3D scene editor are each for, what they share (tags, deploy, alarms, navigation, phones) and where they differ (commands, editions, editing on a phone). - [Connections, lines and stations](https://eaxware.com/docs/eaxscada/explanation/connections-and-stations.md): How the Drivers workspace models your equipment - one connection per controller, server or broker (Siemens S7, Rockwell Logix, Omron FINS, MELSEC over MC protocol, Modbus TCP, OPC UA, MQTT), or a serial line, CAN bus, RTU gateway or Modbus TCP gateway with one station per device - what each protocol needs, how each device is polled at its own scan rate, which drivers write text, and how existing channels and devices map onto it. - [3D digital twin](https://eaxware.com/docs/eaxscada/explanation/digital-twin-3d.md): How the eaxScada 3D digital twin works - scenes stored as displays, one renderer for Studio and the operator runtime, equipment driven by live tags, alarms on the model and read-only interaction for operators. - [Part and lot genealogy](https://eaxware.com/docs/eaxscada/explanation/genealogy.md): What eaxScada records about parts and lots (units, lots, links, operations, results), how the tamper-evident chain and its anchors in the audit trail work, why the PLC acknowledgement waits for the disk, editions, permissions and personal data, remote access, high availability and the limits. - [High-performance displays](https://eaxware.com/docs/eaxscada/explanation/high-performance-displays.md): Why the situational-awareness objects are grey by default and take a colour only when a value is abnormal, where their limits come from, how they draw Bad, Uncertain, stale and missing values, how they appear on a phone, and which of the five objects to use where. - [Historian](https://eaxware.com/docs/eaxscada/explanation/historian.md): How the eaxScada historian stores and queries time series, with the columnar historian engine in every edition and the Hive-partitioned CSV engine in builds without the embedded database. - [How live values reach screens](https://eaxware.com/docs/eaxscada/explanation/live-values.md): How eaxScada sends live tag values to the Studio and the operator runtime - only the tags the open views show, batched every 100 ms, read rights checked when a tag is subscribed, and tags that are refused, unknown or released shown Bad with no value. What it costs a control room, what happens on navigation, when the link goes down or silent (the 5 s heartbeat) and on a reconnect, and why a browser tab opened before an upgrade shows stale values until it is reloaded. - [MCP AI gateway](https://eaxware.com/docs/eaxscada/explanation/mcp-ai-gateway.md): How eaxScada exposes plant context to AI assistants over the Model Context Protocol, and why every write an assistant proposes waits for a human approval. - [OEE and downtime](https://eaxware.com/docs/eaxscada/explanation/oee-and-downtime.md): How eaxScada (Pro and Enterprise) works out machine states, downtime events and OEE from the historian - the four state classes, the six time categories and their order, planned and unplanned downtime, micro-stops, availability, performance, quality and OEE as the server computes them, coverage and the quality of a result, counts and their checks, final and provisional rows (settle, write interval), backfill and recompute, high availability and failover, retention, and why the module never writes to a machine. - [Operator runtime](https://eaxware.com/docs/eaxscada/explanation/operator-runtime.md): How the eaxScada operator runtime presents screens to operators, from dock layouts and kiosk mode to tag writes, hot reload, DVR replay, and screen scripts and why they run in a sandbox. - [How project checkpoints work](https://eaxware.com/docs/eaxscada/explanation/project-checkpoints.md): What a project checkpoint holds and never holds, how it is stored and checked, the automatic checkpoints and their retention, who may do what, why a revert is safe (channels left disabled, settings never lowered, built-in alarms untouched, screens held for Deploy, the e-stop rule), what happens when it fails, project archives and encrypted server backups, the recovery key, the 3-2-1 backup strategy, and the audit events. - [Screen designer](https://eaxware.com/docs/eaxscada/explanation/screen-designer.md): How the eaxScada Dev Studio screen designer works, from the layered vector canvas to procedural piping, matrix arrays, faceplates and display versioning. - [The signed shift log](https://eaxware.com/docs/eaxscada/explanation/shift-log.md): How the eaxScada shift log (Enterprise only) keeps its records - every entry is an audit-trail record, which entries are password-signed and with which meanings, the fields of each type, what a settings change does to signatures, the handover and its states, corrections instead of edits, open items carried from shift to shift, high availability, what happens when the licence changes, and how long records are kept. - [How texts, fonts, states and languages are resolved](https://eaxware.com/docs/eaxscada/explanation/text-and-states.md): Why every text and state colour on an eaxScada screen goes through one resolver - language, then text style, then object state, then the object's own settings - what each layer can change, and what this means for old screens, new object types and safety. - [How eaxScada protects tag writes](https://eaxware.com/docs/eaxscada/explanation/write-protection.md): What the screen, the eaxScada server and the PLC each enforce when someone writes a tag - unknown tags, the screen access check, write limits and write ranges, the engineering range, screen interlocks, confirmations and electronic signatures, screen parameters - in which order the server checks them, which writers they cover, and why a real safety interlock belongs in the PLC. ## eaxPLC: How-to guide - [Apply fieldbus changes without stopping the other devices](https://eaxware.com/docs/eaxplc/how-to/apply-fieldbus-changes.md): What a fieldbus Apply restarts and what keeps running - per-device restarts on Modbus TCP and EtherNet/IP, whole-bus restarts on EtherCAT, CANopen and MQTT, the cases where every device restarts - and how to read "Last Apply", device by device, in the Studio and in GET /api/fieldbus. - [Choose the Studio language](https://eaxware.com/docs/eaxplc/how-to/choose-the-studio-language.md): Choose the eaxPLC Web Studio's language (English, French, German, Italian or Spanish); signed in, the choice is stored per user on the PLC and follows the person to every browser (GET/POST /api/auth/prefs); the limits with break-glass local accounts and in development mode. - [Compare and merge versions](https://eaxware.com/docs/eaxplc/how-to/compare-and-merge-versions.md): Compare any two of the program running on the eaxPLC, the saved project, your drafts and a revision from the program history, POU by POU, with a line diff for ST and a rung diff for ladder, then take the other side's POU, rungs or declarations into your own draft. The running program is never changed. - [Connect CANopen devices](https://eaxware.com/docs/eaxplc/how-to/connect-canopen-devices.md): Run eaxPLC as the CANopen master of a CAN bus (SocketCAN on Linux, an SLCAN adapter on Windows or Linux), import the nodes' EDS, DCF, XDD or XDC files, configure PDOs and boot SDOs, and map the process data to %I and %Q. - [Connect MQTT and Sparkplug B inputs (network I/O, not for safety functions)](https://eaxware.com/docs/eaxplc/how-to/connect-mqtt-sparkplug-inputs.md): Map MQTT JSON values and Sparkplug B metrics onto the PLC's %I inputs, with a quality signal the program can see, broker security, the safety-target refusals, and the Sparkplug B and JSON rules. Network I/O, not for safety functions. eaxPLC Standard and Performance. - [Create a global variable list and a structure](https://eaxware.com/docs/eaxplc/how-to/create-global-variables-and-structures.md): Add a structure data type and a global variable list to an eaxPLC project in the Studio, declare an array of the structure and an alias, use them from a program, and run the change with Test edits or Build & Deploy. - [Document variables without a deploy](https://eaxware.com/docs/eaxplc/how-to/document-variables.md): Give eaxPLC variables and structure members a description, engineering unit, display format and notes in the tag database; the documentation is saved at once as a project revision, never linked into the program, so it needs no test, no deploy and no signature. - [Exchange data types and global variables as PLCopen XML](https://eaxware.com/docs/eaxplc/how-to/exchange-plcopen-xml.md): Export an eaxPLC project's data types and global variable lists as PLCopen TC6 XML 2.01, and import them from another engineering tool with a preview - what travels, what is skipped and why, and the limits on an imported file. - [Export and import the tag database as CSV](https://eaxware.com/docs/eaxplc/how-to/export-and-import-the-tag-database.md): Export every declared variable of an eaxPLC project with its type, address, initial value, access, write range and documentation as CSV, edit it in a spreadsheet, and import it back with a preview; what each column means, what an empty cell does, and how the import writes drafts and documentation. - [Find references and the I/O map in eaxPLC](https://eaxware.com/docs/eaxplc/how-to/find-references-and-io-map.md): List every place a PLC variable is read and written, see each %I, %Q and %M address with its variables and fieldbus point, and run the output-conflict checks. - [Link a PLC to eaxCloud](https://eaxware.com/docs/eaxplc/how-to/link-a-plc-to-eaxcloud.md): In the eaxPLC Web Studio, File > Cloud shows this PLC's eaxCloud link and lets an Administrator enrol the PLC with a one-time token or disconnect it. The link is outbound and read-only - nothing from the cloud reaches the scan. - [Make online edits](https://eaxware.com/docs/eaxplc/how-to/make-online-edits.md): Test a changed program on a running eaxPLC with the accepted program kept resident, put it back at once with Untest, then accept or cancel the edits - with the impact report, the change markers, the e-signatures and what happens at a restart. - [Publish to an MQTT broker](https://eaxware.com/docs/eaxplc/how-to/publish-to-an-mqtt-broker.md): Publish an eaxPLC's Unified Namespace straight to an MQTT broker, as JSON topics or as a Sparkplug B edge node, without eaxScada in between; publishing never runs on the scan, and writes from the broker are off by default. - [Run an edge runtime next to eaxScada](https://eaxware.com/docs/eaxplc/how-to/run-an-edge-runtime.md): Register an eaxPLC edge runtime (eaxplc-rt) with eaxScada, run it with its own NATS identity, program and monitor it remotely, and write or force values. - [Save trend sets](https://eaxware.com/docs/eaxplc/how-to/save-trend-sets.md): Keep named lists of variables to trend together in the eaxPLC project, add variables from the tag database, the cross-reference, the editor or the quick-watch card, record and read them as a chart, a values grid or both, export PNG and CSV, and get the sets back with a rollback. - [Search and replace across the project](https://eaxware.com/docs/eaxplc/how-to/search-and-replace-across-the-project.md): Find a name or a pattern in every POU, ladder diagram, variable documentation, task and fieldbus entry of an eaxPLC project, jump to each match, and replace it in the drafts of the POUs you have checked out, with a preview first and one undo. A replace never saves a revision and never deploys. - [Set external access and write limits](https://eaxware.com/docs/eaxplc/how-to/set-external-access-and-write-limits.md): Make a variable read-only, hidden or writable from outside the eaxPLC program, and bound the values outside clients may write, from the tag database; then apply the change with Test edits or Build & Deploy and check that writes are refused. - [Set the deploy settings](https://eaxware.com/docs/eaxplc/how-to/set-the-deploy-settings.md): In the eaxPLC Web Studio, choose what the PLC requires before it loads a program - an e-signature, a signed review approval or both - and deploy or roll back through the deploy dialog that says what the PLC will ask for. - [Set the project compile settings](https://eaxware.com/docs/eaxplc/how-to/set-the-project-compile-settings.md): Choose whether an out-of-range store into a subrange variable is clamped or stops the task, and set how many bytes an online change may copy per switch, in the Studio's Program settings card or through the API; how the settings are signed with the program, when they take effect, and how to check what runs. - [Watch the licence end date](https://eaxware.com/docs/eaxplc/how-to/watch-the-licence-end-date.md): See when an eaxPLC licence with an end date (a trial key, for example) ends, in the Studio's Licence & edition view, its status-bar marker and the Diagnostics & Events panel, or through GET /api/licence (expiry_state, days_left, loses); what the PLC keeps and loses after the date, and how to renew. - [Watch a value on hover](https://eaxware.com/docs/eaxplc/how-to/watch-values-on-hover.md): Rest the pointer on a variable in the eaxPLC Studio's ST editor or ladder diagram to see its live value, type, quality and force state, and add it to the watch list or the open trend set. The card is read-only. ## eaxPLC: Reference - [Constants, outside writes and forces](https://eaxware.com/docs/eaxplc/reference/constants-writes-and-forces.md): How eaxPLC protects a VAR CONSTANT from every outside path (runtime API, NATS, OPC UA, UNS, Modbus TCP), what happens to forces and queued writes when a deploy or an online edit switches the program, and the order in which a project's FUNCTION_BLOCKs are linked - with the refusal codes and the audit records. - [Deploy settings](https://eaxware.com/docs/eaxplc/reference/deploy-settings.md): The two deploy settings eaxPLC enforces itself on every program load - Require e-signature to deploy and Require a signed review approval to deploy - with their defaults, who may change them, the API, the refusal codes, the PLC's deploy ledger and rollbacks, the trusted approval key, the approval's validity and the audit records. - [Diagnostic events](https://eaxware.com/docs/eaxplc/reference/diagnostic-events.md): The events the PLC raises while it keeps running (RANGE_CLAMPED, LICENCE_EXPIRING, LICENCE_EXPIRED, LICENCE_EXPIRY_CLEARED), their severity and JSON, where they go (log, audit trail, the Studio's Diagnostics & Events panel, GET /api/diagnostics/events, NATS plc..events), and why a slow reader never slows the scan. - [Standard and utility function blocks](https://eaxware.com/docs/eaxplc/reference/function-blocks.md): Inputs, outputs and behaviour of the IEC 61131-3 standard and utility function blocks of eaxPLC (timers, counters, edge detectors, PID, generators, scaling). - [Command-line flags](https://eaxware.com/docs/eaxplc/reference/generated/cli.md): Every command-line flag of the eaxPLC binaries, with type, default and description. - [Fieldbus configuration](https://eaxware.com/docs/eaxplc/reference/generated/config/fieldbus.md): Fieldbus configuration: every key, its type and meaning, generated from the Go structs that decode it. - [Runtime HTTP API routes](https://eaxware.com/docs/eaxplc/reference/generated/http-api-runtime.md): Every HTTP route of the eaxPLC runtime (plc-runtime, plc-server): methods, path and the role required to call it. - [Function blocks](https://eaxware.com/docs/eaxplc/reference/generated/iec/function-blocks.md): The native and ST library function blocks of eaxPLC: every pin with its direction and IEC type. - [Standard functions](https://eaxware.com/docs/eaxplc/reference/generated/iec/standard-functions.md): The IEC 61131-3 standard functions the eaxPLC ST compiler accepts: arguments, result type and behaviour. - [Ladder diagrams and their generated ST](https://eaxware.com/docs/eaxplc/reference/ladder-diagrams-and-generated-st.md): How a ladder (LD) POU becomes the Structured Text that runs - who generates it, what the PLC refuses on a save, how data/ladder diagrams and running programs are migrated into the project, and how a diagram uses global variables with VAR_EXTERNAL. - [Runtime metrics and health snapshot](https://eaxware.com/docs/eaxplc/reference/metrics.md): The eaxPLC runtime's Prometheus metrics (GET /metrics), the versioned JSON health snapshot served on the PLC's NATS API, and the correlation fields of its structured logs. - [MQTT input quality and limits](https://eaxware.com/docs/eaxplc/reference/mqtt-input-quality.md): The quality codes and labels of eaxPLC's MQTT and Sparkplug B inputs (network I/O, not for safety functions), the quality outputs the program reads, the on_bad choices, the source counters, and the limits and ranges of an MQTT bus. - [ST language: phase 3 additions](https://eaxware.com/docs/eaxplc/reference/st-language-phase-3.md): Exact Structured Text syntax eaxPLC added for its data model - TYPE (STRUCT, UNION, enumeration, subrange, alias type), VAR_GLOBAL [CONSTANT], VAR_EXTERNAL, aliases (AT path, bits), FUNCTION, VAR_IN_OUT, the access, write_range and was attributes, the PLC's own {gvl} and {project} lines, reserved keywords, constant expressions in bounds - and the compile errors and warnings with their exact messages. - [What's new in eaxPLC](https://eaxware.com/docs/eaxplc/whats-new.md): The eaxPLC changes for the next release - the data model (global variable lists, data types, aliases, FUNCTION, VAR_IN_OUT, the tag database, external access enforced on every outside path, member-wise migration of structures), the deploy settings the PLC enforces itself, the Web Studio's Project Settings and deploy dialog, the engineering tools (project search and replace, quick-watch on hover, trend sets, compare and merge), MQTT and Sparkplug B inputs, review requests and reviewed rollbacks from the Web Studio, the eaxCloud link page, Modbus TCP reads from the last cycle, the real-time scan in containers - and the upgrade notes that list what now behaves differently. ## eaxPLC: Explanation - [Compiler and bytecode VM](https://eaxware.com/docs/eaxplc/explanation/compiler-and-vm.md): How eaxPLC compiles Structured Text to bytecode, lays out memory for variables and function blocks, and executes it in a zero-allocation stack VM. - [Data model: global variables, data types and external access](https://eaxware.com/docs/eaxplc/explanation/data-model.md): What global variable lists, data types (STRUCT, UNION, enumeration, subrange, alias type), aliases, FUNCTIONs and VAR_IN_OUT are in eaxPLC, how the PLC enforces external access (none, read, read-write) and write ranges on every outside path, how forces and CONSTANTs fit in, and why access is signed with the program while descriptions are not. - [Online changes to data structures](https://eaxware.com/docs/eaxplc/explanation/online-changes-to-data-structures.md): How eaxPLC keeps live values when a structure, enumeration or function block type changes during an online edit or a deploy - member-wise migration at the switch (copied, initialised, dropped), what an untest gives back, the migration cap and its refusal while the PLC runs, renames with the was attribute, and the cases where a value is initialised instead. - [eaxPLC runtime architecture](https://eaxware.com/docs/eaxplc/explanation/runtime-architecture.md): How the eaxPLC runtime schedules scans, lays out the process image, executes and hot-reloads programs, streams telemetry, exchanges fieldbus I/O and records every cycle. ## Platform: How-to guide - [eaxCollab inbox language](https://eaxware.com/docs/platform/how-to/eaxcollab-inbox-language.md): Choose the language of the eaxCollab web inbox (English, French, German, Italian or Spanish) on the sign-in page or in the Me view; the choice is kept per member on the server, follows the member to every browser and sets the Daily digest's language (-digest-lang for members without one); what always stays in its author's words, signed approvals included; the upgrade step for existing servers (service reissue), and refused requests in the server log. - [Install eaxScada](https://eaxware.com/docs/platform/how-to/install.md): Install eaxScada as a native binary, a Docker container, a Docker Compose stack or a hardened systemd service, then check that it is healthy. ## Platform: Reference - [eaxsim scenario checks and eaxsimctl test](https://eaxware.com/docs/platform/reference/eaxsim-scenario-checks.md): Pass/fail checks in an eaxsim scenario (expect), how eaxsimctl test, eaxsim -report and eaxsim-cloud run them in virtual time, their exit codes, the eaxsim.checks/1 JSON report and a CI gate example. - [Editions](https://eaxware.com/docs/platform/reference/editions.md): The eaxScada, eaxPLC and eaxCloud editions, their prices, and the capabilities each edition includes. - [eaxsim-cloud configuration](https://eaxware.com/docs/platform/reference/generated/config/eaxsim-cloud.md): eaxsim-cloud configuration: every key, its type and meaning, generated from the Go structs that decode it. - [eaxsim scenario](https://eaxware.com/docs/platform/reference/generated/config/sim-scenario.md): eaxsim scenario: every key, its type and meaning, generated from the Go structs that decode it. - [eaxsim HTTP API routes](https://eaxware.com/docs/platform/reference/generated/http-api-eaxsim.md): Every HTTP route of the eaxsim plant-simulation host: methods and path. - [eaxsim-cloud HTTP API routes](https://eaxware.com/docs/platform/reference/generated/http-api-eaxsim-cloud.md): Every HTTP route of the eaxsim-cloud simulation control plane: methods, path and the key each one needs. - [Signed commands](https://eaxware.com/docs/platform/reference/signed-commands.md): Wire formats for signing a uns.command.write NATS command, either with a person's one-time e-signature ticket or with a registered integration's NKey signature, and when a signature is required. ## Platform: Explanation - [Platform architecture](https://eaxware.com/docs/platform/explanation/architecture.md): How eaxScada collapses the classic SCADA stack into one Go binary, and how eaxPLC and eaxCloud fit around it. - [eaxCloud](https://eaxware.com/docs/platform/explanation/eaxcloud.md): What the optional eaxCloud subscription is today and what is in development, the two parts it is made of, and how sites connect to it, remote access included, without opening inbound ports. - [Observability](https://eaxware.com/docs/platform/explanation/observability.md): How eaxScada and eaxPLC report their own health - standard metrics, one structured log with request ids, a built-in System Health workspace with history in the product's own historian - and why operational telemetry never duplicates the Part 11 audit trail. - [Security and 21 CFR Part 11](https://eaxware.com/docs/platform/explanation/security-and-part-11.md): The eaxScada security model, from local RBAC, IEC 62443 account lockout per account and address, idle time and session maximum per group and view-only stations to the SHA-256 chained audit trail in its own database (Starter, Pro and Enterprise), electronic signatures, enterprise single sign-on and the origin check of requests a cookie authenticates. - [The Unified Namespace](https://eaxware.com/docs/platform/explanation/unified-namespace.md): How eaxScada implements the Unified Namespace with an embedded NATS broker, ISA-95 subjects, JetStream streams, Key-Value buckets and NKey authentication.