Skip to content

Platform architecture

PlatformExplanationStarterProEnterpriseCloudView as Markdown

Migrated page, not yet verified against the current code. Treat values, paths and examples as indicative until this notice is removed.

eaxScada is an AI-native industrial automation platform written in Go. One binary contains the tag engine, an embedded NATS JetStream broker for the Unified Namespace, a historian, a 2D screen designer (with procedural piping and 3D digital twins in Pro), an operator runtime with DVR replay, an ANSI/ISA-18.2 alarm subsystem, a 21 CFR Part 11 audit ledger and a governed Model Context Protocol (MCP) gateway for AI assistants.

eaxPLC is the companion IEC 61131-3 soft PLC, and eaxCloud is the optional fleet subscription, in development (early access 2027). The editions and what each one includes are listed in Editions.


Page What it covers
Install eaxScada Bare-metal binary setup, Docker, Docker Compose, systemd service hardening and first health checks.
Server flags and configuration scada-server command-line flags, config.yaml and network ports.
The Unified Namespace ISA-95 topic hierarchies, the embedded NATS broker, JetStream persistence, Key-Value stores, Ed25519 NKey authentication and the software-defined DMZ.
Screen designer The layered vector canvas, procedural piping (Pro), ISA-5.1 auto-routing, the matrix array generator, 3D digital twins, composite faceplates and display versioning.
Expression language Tag reference syntaxes, the reactive dependency index, transform pipelines, threshold bands and alarm blinking.
Operator runtime Dock layouts, kiosk mode, the heartbeat LED, operator tag writes, DVR replay and the client scripting API.
Historian and Alarms The columnar historian engine (every edition), the Hive-partitioned CSV engine (builds without the embedded database), and the ISA-18.2 alarm lifecycle, shelving and the SOE journal.
Security and 21 CFR Part 11 Local RBAC and IEC 62443 lockout, the SHA-256 chained audit ledger, e-signatures and enterprise SSO.
MCP AI gateway JSON-RPC 2.0 resources, tools and prompts, and the human-in-the-loop staged write workflow.
eaxPLC runtime architecture The scan scheduler, process image, VM, hot reload and telemetry pipeline.

Traditional industrial automation stacks are fragmented: a proprietary PLC rack talks over specialised fieldbuses to an OPC UA gateway, which forwards to a heavy SCADA runtime, which inserts into an external relational database, which connects to a separate historian server, which forwards to an enterprise cloud. Each layer adds latency, hardware, licence fees and attack surface.

eaxScada collapses this stack into a single Go binary:

System architectureThe parts inside the one eaxScada process
The parts inside the one eaxScada processOne eaxScada server process holds every part. The Studio, the operator runtime and the AI gateway are served by its web and API layer. Under it, the tag engine holds every value: drivers feed it, and each change goes to the open screens, to the Unified Namespace, to the alarm engine and to the historian. The link to eaxPLC runtimes runs over the Unified Namespace. Security and the audit trail are in the same process.EAXSCADA SERVER: ONE PROCESSWeb and API layerStudiodesigns screens and tagsOperator runtimescreens with live valuesAI gatewayMCP serverUnified Namespaceembedded NATS brokerTag engineevery tag valueAlarmsevaluated on each sampleeaxPLC linklocal and edge runtimesDriverscontrollers and devicesHistorianhistory of tag valuesSecurity and audit trailusers, roles and sessions; the audit trail in its own databaseeach change,over the WebSocketvaluesover NATS
There is no second server to install: the broker, the historian, the alarms and the audit trail start with the one binary.
  • Service or process
  • Data store
  • Bus or line
  • Data or telemetry
Read as text

One eaxScada server process holds every part. The Studio, the operator runtime and the AI gateway are served by its web and API layer. Under it, the tag engine holds every value: drivers feed it, and each change goes to the open screens, to the Unified Namespace, to the alarm engine and to the historian. The link to eaxPLC runtimes runs over the Unified Namespace. Security and the audit trail are in the same process.

Parts

  • Web and API layer (layer)
  • Studio (service or process, inside eaxScada server: one process): designs screens and tags
  • Operator runtime (service or process, inside eaxScada server: one process): screens with live values
  • AI gateway (service or process, inside eaxScada server: one process): MCP server
  • Unified Namespace (bus or line, inside eaxScada server: one process): embedded NATS broker
  • Tag engine (service or process, inside eaxScada server: one process): every tag value
  • Alarms (service or process, inside eaxScada server: one process): evaluated on each sample
  • eaxPLC link (service or process, inside eaxScada server: one process): local and edge runtimes
  • Drivers (service or process, inside eaxScada server: one process): controllers and devices
  • Historian (data store, inside eaxScada server: one process): history of tag values
  • Security and audit trail (service or process, inside eaxScada server: one process): users, roles and sessions; the audit trail in its own database

Connections

  • Tag engine → Operator runtime (data or telemetry): each change, over the WebSocket
  • Tag engine → Unified Namespace (data or telemetry). The tag engine publishes each change on the Unified Namespace.
  • Tag engine → Alarms (data or telemetry). The alarm engine evaluates each sample of a tag.
  • Tag engine → Historian (data or telemetry). Each change of a number tag is handed to the historian.
  • Drivers → Tag engine (data or telemetry): values
  • eaxPLC link ↔ Unified Namespace (data or telemetry): over NATS
  1. Deterministic speed with unlimited tags. The L1 tag engine uses a Struct-of-Arrays (SoA) layout with atomic RCU pointers. Concurrent WebSockets, control scripts and alarms read telemetry without lock contention. Tag capacity is unlimited in every edition.
  2. Two historian engines.
    • Every edition, Starter included: the columnar historian engine (the embedded database, in the same server process), with a lock-free in-memory ring buffer, vectorised micro-batches, and in-place querying of Hive CSV folders written earlier. There is no external database to install. Pro and Enterprise add the features built on it: part and lot genealogy and compressed Parquet exports.
    • Builds without the embedded database (the command-line tools): a pure-Go, no-CGO Hive-partitioned CSV appender (data/historian/year=YYYY/month=MM/day=DD/tag=.../*.csv). The files open directly in a spreadsheet or any data tool.
  3. Event-driven Unified Namespace. The embedded NATS engine is the central nervous system. Telemetry, alarms, audit records and commands publish to ISA-95 topic hierarchies (enterprise/site/area/line/cell/tag).
  4. Air-gapped security. No external authentication servers or cloud services are required. Every edition has local RBAC and IEC 62443 account lockout. Starter, Pro and Enterprise keep the SHA-256 chained audit trail in its own database; Enterprise adds two-factor electronic signatures for 21 CFR Part 11. Pro and Enterprise add LDAP / Active Directory and OIDC single sign-on.
  5. Governed AI reasoning. The embedded MCP server lets external AI assistants query history and screen topology, but never actuate equipment directly: writes go through a human-in-the-loop staging queue that an operator approves.

eaxPLC is the deterministic IEC 61131-3 soft PLC written in Go. It runs Structured Text in a fixed scan cycle on industrial PCs, with a pre-allocated process image and a stack-based bytecode VM that allocates nothing on the Go heap during the scan. See eaxPLC runtime architecture.

eaxScada supervises eaxPLC runtimes over NATS. The diagram shows the paths; the list below gives the details.

System architectureeaxScada supervises eaxPLC runtimes over NATS
eaxScada supervises eaxPLC runtimes over NATSA signed-in user and an AI assistant reach eaxPLC runtimes only through eaxScada, which checks the permission, asks for the e-signature where one is needed and audits the call. eaxScada reaches a local runtime and edge runtimes over NATS.NETWORK · NATSSigned-in userAI assistantan MCP clienteaxScadapermission checke-signatureaudit recordeaxPLClocal runtime--plc-url, --plc-idledger: every call,with its usereaxPLCedge runtime--edge-plcsown broker identityeaxCloudoptional fleetsubscriptionIN DEVELOPMENTsign-inPLC toolsdeploy, rollback,watchdog: e-signedCMDforce I/O,plc.forcestatestatus out
Every engineering call passes through eaxScada and carries the signed-in user. Deploys, rollbacks and watchdog changes are e-signed; forcing I/O needs the plc.force right.
  • Product
  • Person or role
  • External system
  • Network
  • Data or telemetry
  • Command to equipment
  • Configuration or deploy
  • Authentication
Read as text

A signed-in user and an AI assistant reach eaxPLC runtimes only through eaxScada, which checks the permission, asks for the e-signature where one is needed and audits the call. eaxScada reaches a local runtime and edge runtimes over NATS.

Parts

  • NATS (network)
  • Signed-in user (person or role)
  • AI assistant (external system): an MCP client
  • eaxScada (product): permission check e-signature audit record
  • eaxPLC (product, inside NATS): local runtime --plc-url, --plc-id ledger: every call, with its user
  • eaxPLC (product, inside NATS): edge runtime --edge-plcs own broker identity
  • eaxCloud (product, in development): optional fleet subscription

Connections

  • Signed-in user → eaxScada (authentication): sign-in
  • AI assistant → eaxScada (data or telemetry): PLC tools. The MCP gateway exposes the PLC tools behind the same permission and audit checks.
  • eaxScada → eaxPLC (configuration or deploy): deploy, rollback, watchdog: e-signed
  • eaxScada → eaxPLC (command to equipment): force I/O, plc.force. Forcing I/O needs the plc.force right and no e-signature; every force, change, unforce and clear is audited.
  • eaxPLC → eaxScada (data or telemetry): state
  • eaxScada → eaxPLC (configuration or deploy)
  • eaxScada → eaxPLC (command to equipment)
  • eaxPLC → eaxScada (data or telemetry)
  • eaxScada → eaxCloud (data or telemetry): status out. eaxCloud is optional and in development (early access 2027).
  • The scada-server flags --plc-url and --plc-id select the local PLC; --edge-plcs registers edge runtimes, each with its own broker identity. See Run an edge runtime next to eaxScada.
  • Engineering calls carry the signed-in eaxScada user and are audited in the PLC’s ledger (eaxScada/internal/plcaudit). Deploys, rollbacks and watchdog changes are e-signed; forcing I/O needs the plc.force right (Lead_Engineer, Administrator; never the AI co-pilot) and no e-signature, and every force, change, unforce and clear is audited.
  • The MCP gateway exposes PLC tools (plc_compile_st, plc_deploy_program, plc_force_io, plc_control, plc_rollback_version) behind the same permission and audit checks. See MCP AI gateway.

eaxCloud, the optional fleet subscription, is in development (early access 2027); its status per capability is described in eaxCloud.


  • Edge deployment (Starter, small skid):
    • CPU: dual-core x86_64 or ARM64 (for example Raspberry Pi 4/5, Intel Celeron J6412)
    • RAM: 1 GB minimum (2 GB recommended)
    • Disk: 4 GB (high-endurance SD, eMMC or SSD for the historian)
  • Production facility server (Pro or Enterprise, large plant):
    • CPU: 8+ core modern x86_64 (Intel Xeon, Core i7/i9, AMD EPYC)
    • RAM: 16 GB to 64 GB ECC
    • Disk: NVMe SSD with high write endurance for the columnar historian and Parquet storage