Skip to content

Compiler and bytecode VM

eaxPLCExplanationFreeProView as Markdown
Data flowFrom Structured Text to code that runs
From Structured Text to code that runsThe project's Structured Text goes through the lexer and the parser, then the bytecode compiler, which checks it and takes the variables' offsets from the layout manager. A parse or compile error refuses the text and nothing that runs changes. The bytecode runs on the VM; on amd64 it is also compiled to machine code, elsewhere to a native plugin built in the background.ST textthe projectLexertokensParserthe syntax treeBytecode compilerchecks, then the code;offsets from thelayout managerRefusednothing changesBytecodethe project's programBytecode VMevery CPU, the fallbackMachine code (JIT)from the first scanNative pluginbuilt in the backgroundparse errorcompile erroralwaysamd64other CPUs
A deploy, a test and a check take the same path, so a check accepts exactly what a deploy accepts.
  • Service or process
  • File or document
  • Data or telemetry
  • Refusal
Read as text

The project's Structured Text goes through the lexer and the parser, then the bytecode compiler, which checks it and takes the variables' offsets from the layout manager. A parse or compile error refuses the text and nothing that runs changes. The bytecode runs on the VM; on amd64 it is also compiled to machine code, elsewhere to a native plugin built in the background.

Parts

  • ST text (file or document): the project
  • Lexer (service or process): tokens
  • Parser (service or process): the syntax tree
  • Bytecode compiler (service or process): checks, then the code; offsets from the layout manager
  • Refused (outcome): nothing changes
  • Bytecode (file or document): the project's program
  • Bytecode VM (service or process): every CPU, the fallback
  • Machine code (JIT) (service or process): from the first scan
  • Native plugin (service or process): built in the background

Connections

  • ST text → Lexer (data or telemetry)
  • Lexer → Parser (data or telemetry)
  • Parser → Bytecode compiler (data or telemetry)
  • Parser → Refused (refusal): parse error
  • Bytecode compiler → Refused (refusal): compile error
  • Bytecode compiler → Bytecode (data or telemetry)
  • Bytecode → Bytecode VM (data or telemetry): always. The VM runs the bytecode on every CPU, and it keeps running when a machine-code or plugin build fails.
  • Bytecode → Machine code (JIT) (data or telemetry): amd64. On amd64, in the executor mode auto or jit, the deploy compiles the bytecode to machine code, which runs from the first scan.
  • Bytecode → Native plugin (data or telemetry): other CPUs. On other CPUs where a plugin can be loaded (executor mode auto), or in the mode native, the bytecode is transpiled to Go and built as a plugin in the background; it is swapped in at a cycle boundary once loaded, and the VM runs until then.
  • Tokenizes Structured Text keywords (PROGRAM, VAR, END_VAR, IF, THEN, ELSIF, ELSE, END_IF).
  • Parses radix/base literals:
    • 16#1A2F (Hexadecimal)
    • 2#1100_0011 (Binary with optional underscores)
    • 8#755 (Octal)
  • Parses IEC time literals:
    • T#500ms, T#2s, T#1h30m

1.2 Layout Manager (pkg/compiler/layout_manager.go)

Section titled “1.2 Layout Manager (pkg/compiler/layout_manager.go)”
  • Allocates the variables without an AT address upwards from the %M base, which follows the CPU tier’s memory partition (%M after %I and %Q: offset 2048 on the base 6144-byte image), into the extended area if needed, and skips every byte the program addresses directly. Offsets are kept across compiles and never reused.
  • Enforces strict 8-byte alignment for composite Function Blocks to prevent unaligned memory faults on ARM/x86 architectures.
  • Memory Footprint Table:
    • Standard types: BOOL (1 byte), BYTE/USINT/SINT (1 byte), INT/UINT/WORD (2 bytes), DINT/UDINT/DWORD/REAL/TIME (4 bytes), LINT/LREAL (8 bytes).
    • Function Blocks:
      • TON, TOF, TP, RTC, CTU, CTD, CTUD: 24 Bytes (8-byte aligned)
      • SR, RS, SEMA, R_TRIG, F_TRIG: 8 Bytes
      • BLINK, GEN, FREQ_MEASURE, RAMP_REAL, RAMP_INT, HYSTERESIS, LIMITALARM, LIN_TRAFO, DERIVATIVE, INTEGRAL, STATISTICS_INT, STATISTICS_REAL, VARIANCE: 32 Bytes
      • PID, PD, PID_FIXCYCLE, CHARCURVE: 64 Bytes

Opcode Mnemonic Description
0 OpNop No operation
1 OpLoadX Load 1-bit boolean from memory bit address onto stack
2 OpStoreX Store top-of-stack boolean into memory bit address
7 OpLoadD Load 32-bit value (DINT, DWORD, REAL, TIME) from memory offset
8 OpStoreD Store top-of-stack 32-bit value into memory offset
12 OpPushU32 Push 32-bit immediate literal onto stack
14 OpAddI Integer addition: stack[sp-2] + stack[sp-1]
15 OpSubI Integer subtraction: stack[sp-2] - stack[sp-1]
16 OpMulI Integer multiplication: stack[sp-2] * stack[sp-1]
17 OpDivI Integer division: stack[sp-2] / stack[sp-1]
18 OpModI Modulo operation
19 OpAnd Bitwise / logical AND
20 OpOr Bitwise / logical OR
21 OpNot Logical NOT
22 OpEq Equality comparison (=)
25 OpGt Greater than comparison (>)
33 OpJmp Unconditional jump to bytecode instruction index
34 OpJmpFalse Jump if top of stack is 0 (false)
36 OpCallTon Execute TON On-Delay timer block at struct offset
45 OpCallBlink Execute BLINK asymmetrical pulse train block at struct offset
47 OpCallGen Execute GEN waveform generator block at struct offset
52 OpCallPid Execute PID closed-loop controller at struct offset
91 OpHalt End of program scan cycle

3. Zero-Allocation Stack VM (pkg/compiler/vm.go)

Section titled “3. Zero-Allocation Stack VM (pkg/compiler/vm.go)”
  • Fixed 256-entry uint64 evaluation stack ([256]uint64).
  • Stack pointer sp tracks depth.
  • Direct pointer casting to function block structures inside process memory:
    case OpCallGen:
    genState := (*fb.GEN)(mem.GetPtr(int(inst.Offset)))
    genState.Update(genState.MODE, genState.BASE, genState.PERIOD, genState.CYCLES, genState.AMPLITUDE, genState.RESET, nowMs)
  • Evaluates instructions in under 10 nanoseconds per opcode with zero garbage collection overhead.

An array may hold instances of a library block (TON, CTU, PID …) or of a user FUNCTION_BLOCK. Its elements are called, read and written like named instances:

VAR
v : ARRAY[1..400] OF FB_Valve;
g : ARRAY[1..2, 1..3] OF FB_Valve; (* 2-D: an array of arrays *)
t : ARRAY[0..7] OF TON;
em : FB_EM; (* holds valves : ARRAY[1..3] OF FB_Valve *)
i, j : INT;
END_VAR
FOR i := 1 TO 400 DO
v[i](Open := Cmd[i], Pos => Pos[i]); (* inputs :=, outputs => *)
END_FOR;
FOR i := 1 TO 2 DO FOR j := 1 TO 3 DO g[i, j](); END_FOR; END_FOR;
t[i](IN := Run, PT := T#2s);
em.valves[i](Open := TRUE); (* through a member *)
v[i].inner(...); (* a block inside an element *)
Done := v[3].Cmd; (* read an output *)
v[3].Open := TRUE; (* write an input *)
  • ARRAY[a..b, c..d] OF X is an array of arrays: g[i, j] and g[i][j] are the same element.
  • A call is valid on an indexed or member expression (FBCallStmt.Instance), not only on a bare name.
  • State per element. Every element is a full instance with its own storage in the process image. Each element starts with the block’s initial values, and keeps its state from scan to scan.
  • Index evaluated once. The instance address of a call is computed once per call: the index expressions are evaluated and range-checked once, whatever the number of inputs and outputs. A side effect in an index happens once.
  • Out of range is a fault. An index outside the declared bounds stops the scan with ErrIndexRange (“array index out of range”), exactly like any other out-of-range array index. Nothing is clamped or wrapped.
  • Whole-block copies into an indexed element (v[i] := proto;) work (OpAddr, OpSwap).

4.3 Code generation: one body, a base register

Section titled “4.3 Code generation: one body, a base register”
  • A user FB body is compiled once per type and shared by all the elements of every array of that type. It runs on a base register (instructions flagged FlagBase address the instance relative to the base).

  • Named instances are unchanged. Each keeps its own body at fixed addresses.

  • VM: OpCallSub saves the base and sets it to the element’s address. OpRet restores it. OpCallSub carries Imm = size<<32 | pc, the instance size and the body’s entry. The base register and its call stack sit at the end of the VM struct, off the interpreter’s hot fields, so a program without arrays of FBs runs at its old speed.

  • JIT (amd64): the base lives in jitCtx. At the call, the JIT checks once that the whole instance lies inside the image. Based accesses, OpAddr, OpSwap and the inline R_TRIG/F_TRIG then run without a check per access. The transpiler’s region functions take the base as a parameter.

  • JIT verifier. Because based accesses are not bounds-checked one by one, assembleJIT first verifies the bytecode. It refuses:

    • a base-relative access without an element offset outside a shared FB body;
    • a body that is also called as a fixed instance;
    • a body called without its instance size;
    • any based access that reaches past the instance (loads, stores, strings, library and nested block calls).

    A refused program runs on the interpreter, as with any other JIT assemble error.

  • Code size. 400 FB_Valve elements in a FOR loop compile to 56 instructions (the same as for 10 elements). 400 named instances compile to 12 003.

BenchmarkFBArrayVsNamed (pkg/compiler/fb_array_jit_test.go) runs one scan of 400 pharma-line actuators, written as an array in a FOR loop and as 400 named instances:

Executor Array vs named instances
VM (interpreter) about 36 % slower: the loop, the index check and the base switch per call cost more than fixed addresses
JIT about 2.8× faster: one compact shared body stays in the instruction cache, instead of 400 copies

On 2026-10-17, with other load on the workstation, a re-run gave: array 314 µs vs named 216 µs on the VM (+45 %), and array 42 µs vs named 119 µs on the JIT (2.8×).

Choose by executor: on the JIT, an array of instances is both smaller and faster. On the interpreter, it is smaller but slower per scan.

  • Cross-reference. A call of an element is recorded on the array, as a partial reference. An array of FBs carries fb_type (the elements’ type), and the editor’s completion uses it: v[i]., g[i, j]. and em.valves[k]. offer the type’s members, and v[i]( offers its parameters.
  • AI guard. A safety target on an element’s member (V[3].Cmd, g[1, 2].Cmd) also protects that member in the shared body of the FB type, for every element, because the body runs for all of them.
    • Safety targets take one or more integer indexes per name.
    • g[1][2].Cmd, g[1,2].Cmd and G[1, 2].cmd are the same target. It is stored with its indexes in one spelling (g[1, 2].Cmd), and listing two spellings of it in the list set on the PLC is refused as a duplicate. In the list eaxScada signs, a tag on an element (…/plc-01/g/1/2/Cmd) becomes the target g[1][2].Cmd, and two tags on one element sign one target.
  • A target listed twice. Two entries are the same target when their names differ only in letter case (EStop, ESTOP) or their indexes only in spelling (g[1][2].Cmd, g[ 1,2 ].Cmd, g[01, 2].Cmd).
    • In the list set on the PLC (Project Settings, POST /api/deploy/safety-targets) the save is refused with g[1, 2].Cmd is listed twice and the list in force does not change. A list file edited by hand with a duplicate is invalid: the PLC then has no list and refuses every AI-made program until an engineer saves the list again.
    • In the list eaxScada signs, the same spelling twice is refused (listed twice). Two spellings of one element are accepted as signed; the PLC applies that target once, in its stored spelling.
    • A target in both lists applies once and is shown as a local target: the signed list only adds targets, it never replaces or removes a local one.
  • A write that matches two targets (a target and a part of it, Safety1 and Safety1.Out; or the member two elements share in the FB body, V[1].Cmd and V[2].Cmd) is refused once per written symbol, naming one of the targets it matches. Removing one of the two targets leaves the symbol protected while the other still covers it.
  • Targets in a program with several PROGRAMs.
    • A variable of a program other than the main one is listed with its program: Line2.Speed, Line2.Valve.Q, Line2.Arr[3].
    • An unscoped name (Speed) is the main program’s variable.
    • When another PROGRAM also declares that name, the list does not say which variable it protects: an AI-made deploy is refused with ai_safety_target_ambiguous, naming the programs and the scoped spellings to list (Line2.Speed, or the main program’s Main.Speed), until the list scopes it.
    • While an AI-made program runs, the scan pin protects every copy of an unscoped name: the main program’s and each other PROGRAM’s variable of that name.
    • POST /api/deploy/ai-status says it before the deploy: refused: true, code: "ai_safety_target_ambiguous" and ambiguous, one line per ambiguous target.