The changes since 9 October 2026, for the next eaxScada release. Read the upgrade notes before you upgrade a production server: several of them make the server refuse something it used to accept.
Editor (Studio)
Section titled “Editor (Studio)”-
Object states and “why” tooltips. Eight states (normal, hover, pressed, on, disabled, bad, locked, not configured), styled for the whole project per object family and per object, previewed on the canvas. A disabled command’s tooltip says why. Style object states
-
Fonts and text styles. System font stacks, the bundled Inter, project font upload with server-side checks, eight named text styles, a font picker and a portability warning. Fonts and text styles
-
Languages. Translation keys, Make translatable for existing screens, the Translations table, CSV for translators, AI drafts marked for review. Translate your project
-
The Studio in your language (18 November, every edition): the Studio has its own language (English, French, German, Italian, Spanish), chosen from the top-bar language button or View > Studio language…, separate from the operator runtime’s language. It is kept in the browser and in your user preferences; English until you choose. Your project’s texts in the editor keep the preview language. Menus, the top bar, the rail, the status bar, the Displays editor’s toolbars, Tags, Alarms, the common dialogs and the workspaces already translated follow it; the rest of the Studio follows in later releases. The Studio’s language, upgrade notes 530 and 531
-
More of the Studio in your language (18 November, every edition): the Drivers workspace (re-drawn on a language change, keeping what you typed), the PLC hardware wizard, the 3D kit, palette and materials, the isometric blocks and their keyboard shortcuts, the 2D Assets tab, the inspector’s States section and the undo history’s step names. Searches find an item by both names. The dashboard’s edit mode is named Edit Layout everywhere (the toolbar said “Edit Matrix”). The Studio’s language, upgrade note 548
-
UDTs with Bool and String members, and a delete that holds (18 November, every edition; safety: engineering data): a member’s default is typed (
true/false, a text, a whole number, a number) and checked against its type; a UDT keeps itscreated_atand getsupdated_at; Delete asks first and deletes on the server, recorded in the audit trail, and is refused (409) while a component template is built on the UDT. Before, a UDT with a Bool or String member could not be saved, and a deleted UDT came back on reload. UDT definitions, upgrade notes 544 to 546 -
Screen parameters. One faceplate for many stations:
{Name}, declared parameters, parameter sets with CSV, Preview with, and a write policy derived per set. Reusable screens with parameters -
Input objects. Numeric entry, slider, spinner, text entry, toggle switch and selector, with limits and confirmation enforced by the server. Add setpoint inputs
-
Alarm objects. Alarm banner, summary, history, counters, annunciator panel, and the alarm classes editor (colours, blink and sound per class and priority). Put alarms on a screen
-
Problems panel and deploy gate. Lint of every screen and component, and an optional block on deploys with errors. Check screens before deploying
-
Find and replace across the selection, a screen, a folder or the project, with a preview grid and a safety confirmation. Find and replace
-
Clipboard, paste special, groups and undo. Copy between screens and tabs, paste with tag prefixes replaced, nested groups with edit-in-group, multi-select on every object, and an undo that always works with named steps. Edit screens
-
Connectors. Pipes and lines glued to the objects they join: drag them out of an object’s + handles, snap to equipment nozzles, side midpoints or the outline, orthogonal routes around objects (straight and curved too), routes that follow moved, resized and turned objects, bends, lock and reset, arrowheads, and Connect ends for older pipes. Connect objects with pipes and lines
-
3D model library. Built-in models removed from (and restored to) a project’s palette while scenes keep drawing them, a
.gltfadded with its.binand textures or as a.zipand packed into one GLB on the server, and a library manager grid. Use the 3D asset library -
Display Settings keep every member they do not edit, and gain the popup window options, the screen’s keyboard and Parameters. Project settings
-
Dashboards. Several dashboards per project: new, rename, duplicate, delete (refused while in use), revisions. Manage dashboards
-
New dashboard cards (21 November, every edition): Time series, State timeline, Stat, Gauge, Bar gauge, Table, Alarm list, Bar / pie, Pareto, Text and the Custom chart, added from a card picker, set up with a live preview, and sharing a time range, refresh and variables. All read only, with quality shown honestly. Build a dashboard, upgrade notes 658 to 667
-
Trends in one card with Chart | Values | Split, the zoom filtering the grid. Trend tags
-
The shared code editor for every code and expression field, with tag completion,
system.*completion and the server parser’s errors. Script a screen -
Layout tools. Align to a key object, match width and height, equal spacing or a fixed gap, zoom to the selection (Shift+2) and to fit (Shift+1), a minimap (M), layer solo (view only), ruler guides saved with the screen, and a shortcut sheet (?) where you change the keys. Arrange objects precisely
-
Several objects at once and drag-to-bind. Every shared property edited on a selection in one undo step, with “mixed” for values that differ (command settings stay one object at a time); a tag dropped on an object binds what it displays, never what it writes. Edit screens
-
History panel with a jump to any step, and a faster undo that redraws only the objects that changed. Edit screens
-
Compare two versions of a screen side by side, with the list of changes and the command changes flagged. Compare two versions of a screen
-
Style classes: named looks for shapes, with theme tokens, per-object overrides, rename and delete with where used, and a
style-class-missingcheck. Style classes -
Situational-awareness objects: moving analog indicator, deviation bar, KPI star, sparkline with limits and mini-trend tile, grey until a value is abnormal. High-performance displays
-
Ctrl+N (Alt+N in a browser tab) is New in the workspace shown. Edit screens
-
3D palette: My models holds the models you added; the built-in models are in the kit groups of their category. Use the 3D asset library
-
Who else is on a screen, and an editing lock with Take over (8 November, every edition, safety: authorization): the project tree and the designer show who else has a screen open (viewing, editing, idle; gone after 60 s), only to people who may read that screen. The first unsaved edit takes the screen’s editing lock; the others open it read-only, with Take over for a Lead_Engineer with the screen’s write and read permission, asked first and recorded in the audit trail before it is made. The previous holder keeps their unsaved changes in their browser: Save as copy or Discard. The lock is advisory: saves keep their revision check. Work on a screen with other engineers, Studio presence API
-
3D navigation (13 November): an axis widget at the top right of the view (click an axis, click again for the opposite side, drag to orbit, double-click the centre for the isometric view), round buttons under it (zoom, pan, free or isometric camera, lock, frame the selection, frame everything), one Transform gizmo (T, the default: move, rotate and scale together, one undo step per drag) beside Move (W), Rotate (E) and Scale (R), and the Numpad view keys and Home. Fix: a view preset no longer keeps the camera spinning. Moving the view and the objects
-
Screen rollback recorded first (13 November, safety: Part 11): restoring an earlier version of a screen is a screen save: its record is written before the file or its history changes, and with the audit trail down it is refused (
503 AUDIT_NOT_WRITTEN) with nothing changed. The commit must be a 7 to 40 character hexadecimal hash. A save or a restore that the version history (Git) did not take stands, with a"warning"; a screen file that cannot be written fails the save. Display version history -
A Tags list on web content objects (16 November, every edition; safety: values operators see): the tags the HTML reads are subscribed with its screen wherever it is shown; screens saved before subscribe the paths the HTML names literally. Web content script API
-
The startup page cannot be deleted (13 November):
409 startup_page. Project settings
Operator runtime
Section titled “Operator runtime”-
Data tables fully in the operator’s language (17 November, every edition): the quality words and their tooltips, the warning markers, the “N rows with warnings” chip, the warning card’s title and the Split tab of a chart-and-table card follow the language each person chose. Language
-
The data table’s own words in the operator’s language (18 November, every edition): the filter menus and their operators, AND / OR, Apply / Reset, the column menu, the pager and the empty and loading texts follow the operator’s language in the runtime. The toolbar switches at once; parts of a table already open switch when the page is reloaded. In German, an eaxCloud site is now a “Standort” in the Studio’s cloud settings and the remote-session texts. Language, upgrade notes 522 and 523
-
Dashboard cards in the operator’s language (18 November, every edition): the cards’ own texts follow the runtime language the operator chose and switch with it; in the dashboard editor they follow the Studio language. What a command writes, and when a card is disabled, are the same in every language. Manage dashboards, upgrade note 549
-
Dashboard commands in the operator’s language (19 November, every edition; safety: commands): the interlock reasons, the confirmation and e-signature dialogs and the success messages of command cards follow the operator’s runtime language. The signed meaning and the audit reason stay English, exactly as recorded; the e-signature dialog shows the meaning verbatim under a translated label. Manage dashboards, upgrade note 555
-
Counts in each language’s plural (19 November, every edition): every grid count and warning chip, in the Studio and the operator runtime, uses the right singular and plural in the five languages (“1 alarm”, not “1 alarms”). The Studio’s language, upgrade note 556
-
A screen waiting for its first values is held whole (17 November, every edition; safety: values operators see, commands to equipment): its HTML objects and isometric maps are hidden and take no input with the drawing, an isometric block refuses every command meanwhile, and the phone’s cards are hidden too; a very large answer sent in parts holds the screen up to 30 seconds with “Loading values… N% (n/m)”; a held screen swapped or left lets go at once. What the operator sees, upgrade notes 487 to 491
-
Isometric screens in inner screens (17 November, every edition; safety: values operators see, commands to equipment): the default inner screen or one loaded with
system.nav.loadInnerDisplayorswapInneris drawn as its live map, fitted to the container (it stayed blank). Inner screens -
Large answers on
/wsin 1 MiB frames (17 November, every edition): aTAG_SNAPSHOTover 1 MiB comes in parts (part,parts,more), a batch of changes over 1 MiB in severalTAG_UPDATESframes, so remote access no longer closes the socket of a screen of a very large area. A snapshot in parts -
The control status in the operator’s language (16 November, every edition; safety: values operators see): the Studio header badge, the runtime HUD, the kiosk indicator and the control-status banners follow the language each person chose (en, fr, de, es, it), and say why the status cannot be read in that language. In a remote session the Studio status bar keeps the alarm summary, with “Control status is not available remotely” only as its tooltip; a gateway fault still replaces it. What people at the site see, upgrade notes 456 to 458
-
Charts, tables and web content follow inner screens and docks (16 November, every edition; safety: values operators see, commands to equipment): charts, data tables, web content, gauges and alarm objects are drawn in the inner screen’s or the dock’s own layer, follow its fit and size, take taps, scroll with a long dock and slide away with an auto-hide dock; a dock waits for its tags; alarm objects in popups are placed from the popup. Docks, upgrade notes 425 to 430
-
Inner screens switched by a script show live values and fit their container (16 November, every edition; safety: values operators see): their tags are subscribed before they are drawn, they are scaled like a page, and
system.nav.swapInnertakes{set}or{params}. Inner screens -
New screens show live values from the start (15 November, every edition; safety: values operators see): a page, dock, popup or inner screen is held hidden until its tags are answered, at most 2 seconds, then a missing value shows Bad; page and popup tags are subscribed from the screen documents before drawing; inner screens show live values (they kept their designed values); a 3D vessel with no usable level shows a hatched amber band; a multi-state indicator without a value shows its fallback state, never State 0, and an update touches only that tag’s indicators. How live values reach screens, upgrade notes 371 to 378
-
Only the tags on screen reach the browser (15 November, every edition; safety: values operators see): each page, popup, dock, grid and trend subscribes the tags it shows, the server checks the read right when a tag is subscribed and sends the changes in one batch every 100 ms. A control room of 20 screens of 300 tags over a project of 100,000 tags costs the server about 0.07 cores instead of 2.4. Reload browser tabs opened before the upgrade. How live values reach screens, Live data socket, upgrade notes 364 to 370
-
Prefix subscriptions on
/ws(16 November, every edition; safety: values operators see, read authorization): a view may subscribePlant/Line1/*, every tag under the path that the user may read, also tags created there later; unreadable tags are only counted, never named or sent. At most 16 prefixes per view (server.ws_max_prefixes). Prefixes, upgrade notes 441 to 445 -
A Columns button on every data table (16 November, every edition): show or hide columns, remembered per table, with Reset and the keyboard; columns offered only for some data or rights follow the operator’s pick, the CSV export keeps its extra columns without showing them, and the toolbar is in the operator’s language. Work with data tables, upgrade notes 446 to 451
-
Property bindings work in the runtime, and a tag update evaluates only what reads it (13 November): a binding that reads another object’s property is kept on save and resolved by the runtime (it always showed Bad); a tag update evaluates only the objects that read that tag, plus those whose reads are not plain tag paths; and
{A/B},[A/B]orA/Binside a quoted string stay text. Reactive dependency index -
Popups with parameters, docks and navigation history. Modal or modeless faceplates, Back, Forward, Home per role, breadcrumbs, consoles. Popups, docks and navigation
-
The runtime in five languages (en, fr, de, it, es), switched without a reload and remembered per user. Translate your project
-
Quality and staleness markers. No object shows a Bad, Uncertain or stale value as good. Show bad and stale values
-
On-screen keypad and keyboard for touch panels and kiosks, and a touch gate that ignores swipes and pinches. Set up touch panels
-
Screen scripting API v1 (
system.tag,nav,popup,alarm,user,file,print,export,ui,timer…) and client events. Screen scripting API -
Server files for screens: named roots with roles per operation and an audit record per call. Use server files
-
The runtime draws deployed screens only. Deploy screens to operators
-
A failed deploy keeps the last good version (2 November): a deploy whose manifest cannot be written (a full disk) fails instead of reporting success, and the previous manifest stays whole; a failed automatic deploy serves the last good deploy instead of an error. A failed automatic deploy keeps the last good version
-
No background polling of routes the server does not offer (4 November): the remote-session banner, the live-change chip and the genealogy entry stop asking a route that answers
404(for this page, and for the browser tab for 10 minutes) or403(for this page), and ask a failing route less often (15 s doubling up to 5 minutes). The live-change chip is not polled at all on an edition without reviews. Nothing is shown; the pages stay as quiet as before. On the public demo one session made 33 requests to/api/remote/sessions, now one. A proxy that routes only part of the API -
Phone cards name computed rows (4 November): a computed text (an expression binding) is named by the link text on its row, so the Plant overview’s three “PLC 100 Hz” rows read “LINE 1”, “LINE 2”, “LINE 3”; with nothing on its row, by the tags it reads (their common parent). A Phone label set in the designer still comes first. Use the runtime on a phone
-
Install eaxScada as an app (4 November): on phones, tablets, panel PCs and desktops, in its own window with the eaxScada icon, opening on the operator runtime. Install app is in the runtime’s Session menu, the phone’s Account sheet and the Studio’s Help menu; iPhones and iPads show “Share > Add to Home Screen”. Installing needs HTTPS (or
localhost). The app keeps no live values, screens or answers on the device and sends every command to the server as before; without the server it shows “No connection to eaxScada. Live values are not shown.” Not offered on eaxCloud remote sessions. Install eaxScada as an app
Write safety
Section titled “Write safety”- Server-enforced interlocks. A simple screen interlock is enforced by the server for every writer, value by value; STOP always works. Enforce interlocks
- Write limits for every writer, from screens and from the tag’s write range. Limit tag writes
- Unknown tags are refused (
404) instead of being created. Limit tag writes - The strictest of the deployed and saved copies decides a write. How eaxScada protects tag writes
- Live editing per project, off for new projects; the automatic deploy runs the same checks as Deploy. Deploy screens to operators
- Fixes: a button’s own interlock was saved but never evaluated; Ctrl+click in the designer ran actions; commands in groups lost their signature; a dashboard reported commands done that the server refused; a Bad interlock value enabled a command.
- NATS commands in an HA pair reach the primary, and are never dropped (13 November, safety: commands to equipment): only the primary with quorum is in the
uns.command.writequeue group, so the brokers route every command to it. A starting HA node takes no command until it is the primary. A command that still reaches a node that may not dispatch (at a switch-over) is refused and answered, countedHA_NOT_PRIMARY; before, the standby could take it and drop it silently. With no node dispatching, a request gets “no responders”. Hardware command subject - A wrong signature on a tag that needs none is
403 signature_rejectedand journaled (13 November, safety: signatures): it was401, which signed the person out, and left no record. It is now journaled asWRITE_DENIED_SIGNATURE_REJECTED, also when approving an AI setpoint. How eaxScada protects tag writes
AI assistant and MCP clients
Section titled “AI assistant and MCP clients”- API tokens for MCP clients such as Claude Code: MCP gateway only, never sign, expire, revocable. Connect Claude or another MCP client
- Proposals: MCP clients propose screens, alarms, driver channels, tag mappings and dashboards; a person applies them with an e-signature, and applied screens wait for Deploy. Review and apply proposals
- AI accounts use the MCP gateway only, never sign or approve; staged values are checked against the write policy when staged and when approved.
- Allow a provider per project from the chat or the settings. Allow the AI assistant in a project
- Attach pictures, PDFs and text files in the assistant chat. Attach files
- History averages never include Bad or overridden values (safety). The minimum, maximum and average the assistant reads in history buckets use Good samples only; a bucket with no Good sample has none. Each bucket says whether it is good, uncertain or bad, an overridden value counts as uncertain, and the assistant is told to report uncertain and bad buckets as such. Quality in min/max/average buckets
- Free historian SQL marks quality (3 November, safety).
scada_query_historianstill returns every sample and never rewrites the query, but each row now carriesquality_class(good,uncertainorbad;<alias>_quality_classfor a renamed quality column), and a query that readsvaluewithout selecting or filtering onqualityis answered with awarninggiving the good-quality filter(quality % 256) >= 192 AND quality <> 512. The assistant is told to report such a result as unchecked, never as a plain reading. Quality in free SQL answers
Security
Section titled “Security”-
View-only stations, idle time per group and the lockout per address (23 November, every edition, Free included; safety: authentication, authorization, values operators see):
- View-only stations. A control-room wall or a line panel shows chosen screens, live, with nobody signed in. An administrator creates the station in Security > Stations and pairs the screen once with a one-time code. The station views as a viewer identity that has no password, never signs in and never writes. Address ranges only narrow a station. Command controls are disabled and say “Sign in to operate”. A person signs in on the screen to act, and the screen returns to viewing only when they sign out or stop using it. Set up a view-only station
- Idle time and session maximum per group. Each group can set an idle time (1 to 720 minutes) and a session maximum (1 to 12 hours); the shortest value among a user’s groups applies, and a station’s idle cap shortens it there. New installations start at 30 minutes of idle time, upgraded ones keep it off until it is set. A countdown with Stay signed in warns before the end; only real input and accepted commands count as activity. Session limits
- Lockout per account and address. 5 wrong passwords from one address lock the account from that address only; 20 from all addresses lock it everywhere; both for 15 minutes. Lockout parameters
- Sessions end everywhere at once: on idle, at the maximum, on sign-out, or when the account is disabled, locked, deleted or its roles or groups change. The live-value socket and the NATS connections close with it, and signature tickets are void. Idle time and session maximum, upgrade notes 733 to 760
-
The security store reopens after a failed write, and refuses everyone meanwhile (17 November, every edition; safety: authentication, authorization): after a failed commit, a full disk or an I/O error the store opens its file again and reloads users, roles and rules from it before any later change is acknowledged; while it reopens or is down every permission check refuses, the Administrator included, sessions are refused and sign-in fails with “sign-in refused: the security store is unavailable; try again in a moment”; a sign-in is refused when its last-login time, failed-attempt count or lockout reset cannot be saved; System Health shows the store’s live state. When the security store reopens after a failed write, upgrade notes 481 to 486
-
A feature DENY refuses PLC control and the server files to the Administrator too (16 November, every edition; safety: authorization): a DENY matching
plc_control(exactly,*,feature:*or a prefix) refuses start, stop, force I/O, deploy and rollback to the Administrator and the engineer roles; a catch-all ALLOW no longer grants PLC control; rules that cannot be read refuse it to everyone; a DENY*,feature:*or prefix covers every server file operation. The Administrator keeps security administration. Feature DENY rules and the Administrator, upgrade notes 463 to 468 -
The permission dialog lists every feature right (16 November): 36 rights in 8 modules, each with its description and edition badge, and the module wildcards; picking one fills exactly that pattern; rights the licence lacks, or that an ALLOW cannot grant, are disabled with the reason; a typed catch-all, prefix or DENY says what it affects. New read-only route
GET /api/auth/feature-rights(Administrator, never remote). Add a feature permission rule, upgrade note 469 -
Remote requests refused by the remote-access check are in the audit trail (16 November, Starter, Pro and Enterprise; safety: audit trail): every request from an eaxCloud remote session that the check refuses, except GET and HEAD, leaves a
REMOTE REMOTE_REQUESTrecord with the refusal and its reason, the session and the eaxCloud portal identity, never the request body. A remote session shows “Control status is not available remotely” instead of an amber warning. What the audit trail records -
A security store that cannot be read refuses every check (16 November, every edition; safety: authorization): tag writes and reads, screens, PLC control, broker connections, MCP
plc.forceand the feature rights;screens.scriptfollows feature DENY rules, the Administrator included. When the security store cannot be read -
Feature DENY rules apply to genealogy, recipes and batches like the other features (15 November; safety: authorization): a catch-all
*or a prefix DENY refuses these rights too, and a matching DENY refuses them to the Administrator as well, who keeps security administration and can always remove the rule. Feature DENY rules and the Administrator, upgrade notes 389 and 392 -
MQTT messages write only the tags their channel maps to the topic (15 November; safety: values operators see): a forged payload
path, an unmapped topic and another channel’s tag are refused and counted; Also accept unmapped tags under opens a tag-path prefix on purpose. Which tags a message may write, upgrade notes 386 to 388 -
Required Access Level is enforced. A screen’s level (anyone signed in, Shift_Operator 40+, Process_Supervisor 60+, Lead_Engineer 80+, Administrator only) now keeps the screen from lower users: not in their menus, You don’t have access to this screen on a link or popup, its buttons never count for their writes; engineers still read every screen in the Studio, and the AI assistant’s tools follow the same levels. Two new Problems panel warnings. Restrict a screen to a role level
-
Require e-signature to deploy, per project: on for new projects, off for existing ones. One signature per deploy, by the deployer, bound to the manifest; live editing waits for a signed Deploy; turning it off needs an engineer’s signature. Require an e-signature to deploy
-
eaxPLC deploy gate. eaxPLC enforces its own deploy settings (e-signature on; signed review approval off by default), and eaxScada attests an approved PLC program review to the PLC. The review page shows the PLC’s gate. Review screens and PLC programs before deploy, What’s new in eaxPLC
-
Review approvals for every PLC deploy path.
POST /api/collab/plc-approvalgives the eaxPLC Web Studio’s deploy dialog the approval of an approved program (Lead_Engineer or Administrator only; journaledPLC_APPROVAL_ISSUED/PLC_APPROVAL_REFUSED), and assistant and MCP deploys of a reviewed program now carry it too. The assistant and MCP keep PLC source byte for byte (no whitespace trimming), so the deployed text is exactly the reviewed text. Design reviews API -
Warnings on grid rows (default passwords, duplicate usernames, locked accounts, roles limited to the old example area) with a card that fixes them. Keep accounts and audit trails in order
-
Two audit tabs, Access audit and Operations audit, each verifying its own chain; engineers and supervisors read the Operations audit. Keep accounts and audit trails in order
-
Offline administrator recovery from the command line. Recover the administrator account
-
Fix: the Topic Rights dialog sent the wrong field, so every rule created in the studio was refused.
-
Remote changes that act on the plant (1 November): from an eaxCloud remote session, a change to drivers, alarms, historian rules, eaxTags, translations, the PLC configuration, the active project or a checkpoint revert can be requested for approval, approved by another site user and applied once by the requester within 60 minutes (Pro, Enterprise). Translations, UDT instantiation, starter templates and deleting the active project now count as acting on the plant; a remote connection test is a probe. Approve remote changes that act on the plant
-
The audit trail is on disk before an action is reported (1 November): appended and synced, write errors reported, and no start without a writable trail. (Since 11 November the trail is a database: see below.) The audit trail on disk
-
More actions recorded first (2 November): project files and assets (fonts, drawings, 3D models, styles, languages, translations, dashboards and their cards), collaboration reviews, comments and live-change claims, accounts, roles, permission rules, identity providers, tokens and signatures, server files (the intent, then the outcome with its SHA-256), deploys let through by a review, and the PLC safety-target lists. Without their record they are refused with
503 AUDIT_NOT_WRITTENand nothing changes; actions toward rest go ahead with a warning, and sign-in and sign-out always go ahead. Recorded first, refused without the record -
Recipe and batch rights (2 November):
recipe.edit,recipe.approve,recipe.download,batch.runandbatch.sign, held from the Process_Supervisor level and narrowed by DENY feature rules; recipe save, delete, download and prompt acknowledgement are recorded first. Who may change recipes and run batches -
Alarm definitions recorded first (2 November): creating, changing and deleting an alarm definition is recorded
ALARM CREATE,UPDATEorDELETEbefore the change, with the definition before and after and their SHA-256; they were not recorded at all before. Alarm definitions in the audit trail -
Every deploy recorded (2 November): an explicit deploy writes
DEPLOYfirst and is refused without it, thenDEPLOY_DONEorDEPLOY_FAILED; an automatic deploy without a review gate is recorded after the fact asDEPLOY_AUTO_DONEorDEPLOY_AUTO_FAILED, once per manifest. Recorded first, refused without the record -
Checkpoint reverts and backup restores recorded change by change (3 November): each alarm definition a revert or a server backup restore adds, changes or removes, and any change to the alarm classes, is recorded before anything is applied (
ALARM CREATE/UPDATE/DELETE,ALARM_CLASSES …, the reason naming the checkpoint or backup). Without the records a revert is refused (503 AUDIT_NOT_WRITTEN) and a restore waits and is tried again. Records written before a revert or restore -
Plant e-stop tag changes recorded first, with the user (3 November):
PROJECT PLANT_ESTOP_TAG, with the old and new tag, on project save, activation, deletion of the active project, a deploy that moves the live signal (explicit or automatic), checkpoint revert and backup restore; without the record the signal does not move. Plant emergency-stop signal tag -
Starter templates check alarm tag reads (3 November): an apply whose alarms name a tag you may not read is refused (
403,denied_tags, nothing applied), as a manual alarm save is; a template alarm whose controller handshake does not check is not added. Alarm definitions in the audit trail -
Alarm class edits carry SHA-256 (3 November): the
ALARM_CLASSES UPDATErecord of a classes save holds the SHA-256 of the document before and after. Alarm classes -
Audit trail memory bounded (3 November; replaced on 11 November by the audit trail database, which holds no records in memory): text that is not valid UTF-8 is recorded with U+FFFD. The audit trail on disk
-
A deploy moves the plant e-stop signal last (3 November, safety): an explicit or automatic deploy moves the signal only after every check (lint gate, review, e-signature) and the
DEPLOYrecord, right before the screens go live, so a refused deploy never leaves it moved. New record orderDEPLOY,PROJECT PLANT_ESTOP_TAG,DEPLOY_DONE; a deploy that fails after the move moves the signal back (PLANT_ESTOP_TAG_FAILED), unless it was set meanwhile, and a signal set between the checks and the move fails the deploy (409). Plant emergency-stop signal tag -
An unreadable audit trail is reported everywhere (3 November, safety): when older records in the ledger file cannot be read, “what this user changed” (
GET /api/xref/uses?kind=user) answers500, genealogy Verify refuses (500,anchors_unreadable, recorded as not verified), and System Health shows Audit trail unreadable in the HA panel and Last historian restore: unreadable in the Backup panel, with theirwarningsas one compact chip, instead of short lists or “none”. The audit trail on disk, System Health -
Read-only watcher identities on the broker (4 November, safety):
--nats-watcher name=<public key or seed file>(EAX_NATS_WATCHERS) admits a program that only watches the PLCs, such as the UNS prefix guard of an eaxsim host. A watcher may subscribe toplc.*.birth,plc.*.statusanduns.telemetry.>only and publishes nothing, not even a reply. Each connection is recorded asNATS_WATCHER_CONNECTED; a key can have one role only, and a bad value stops the start. Without the option the broker admits exactly what it did. NATS identities on the broker, Connect an eaxsim host to eaxScada’s broker -
A wrong password in a signature dialog no longer signs you out (6 November, safety): every route that checks an e-signature answers a refused signature
403withstatus: "signature_refused"and keeps401for “no session”; the dialog stays open with an empty password field. The lockout is unchanged. eaxPLC tells a refused signature from an ended eaxScada session too. A refused signature is not an ended session -
Go security update (28 October): eaxScada is built with Go 1.27.3, with its TLS certificate and standard library security fixes, and the build refuses an older toolchain. The SAML sign-in component is updated to fix a signature check that could be bypassed.
-
Screen scripts run in a sandbox (7 November, breaking, safety): Run script actions and startup scripts run in a sandboxed frame without access to the operator’s page, session or network, and act only through an allow-listed
system.*, each call checked and run under the operator’s session (a tag write asks for its confirmation and e-signature as a button does). Everysystem.*call returns a Promise;playerandthisare gone; a script stuck for 5 seconds is stopped and the screen stays usable; a refused or stopped script is marked on its object. Two new Problems panel warnings list scripts that use the page. Migrate screen scripts to the sandbox, Why screen scripts run in a sandbox -
A right to write screen scripts (7 November, safety): adding or changing a script needs
screens.script(Administrator, Lead_Engineer and roles of level 80 or more; a DENY rule takes it from an engineer role; never the AI co-pilot), on every save path; moving, restyling or removing needs no right. Grant the right to write screen scripts -
See what a deploy changes, and acknowledge command changes (7 November, breaking for API clients, safety): the Deploy dialog lists the screens changed (with Compare), the command targets added, removed and changed, the screen scripts, the write-policy changes and the screen checks, compared with the deploy operators run. A deploy that changes command targets, scripts or the write policy needs a reason, recorded in the
DEPLOYrecord with the preview’s hash; the deploy then publishes exactly what was shown. Live editing is recorded (DEPLOY_AUTO_PREVIEW), never blocked. Review what a deploy changes -
Legacy screen scripts, per project (7 November): off for every project; an Administrator may turn it on with a reason, journaled, to run a project’s scripts in the page as before while they are rewritten. Legacy screen scripts
-
No JetStream for users, telemetry published only by name, ingested only by name (13 November, breaking for NATS clients with their own credentials, safety: authorization and values operators see): no user connection gets JetStream or the broker’s own subjects (
$JS,$KV,$SYS…), whatever its role; a user publishes onuns.telemetryonly with a rule that names it, and>no longer grants it; a NATS channel ingests a telemetry message only when its subject names the tag of its payload (eaxscada_uns_ingest_refused_total); a NATS channel never writes to a telemetry subject, and a write the broker refuses is reported as failed. Subject-level access control -
Broker permissions follow the tag-path rules (13 November, breaking for NATS clients with their own credentials, safety: authorization): a tag-path rule of a role now governs the tag’s
uns.telemetrysubjects on the broker, deny rules included; before, such a rule reached the broker as one literal token, so a tag-path deny blocked nothing there and a tag-path allow allowed nothing. A role with no subscribe rule now receives only its replies and the PLC API subjects, not every subject. Subject-level access control -
NATS bridge on this server’s own broker, and passwords in URLs kept secret (18 November, safety: authentication, authorization, values operators see): a NATS bridge can read eaxScada’s own broker with no credentials, through an identity of its own that only subscribes to its inbound subjects under
uns.telemetry.; it publishes nothing, every write on it is refused, and its values are never republished. A password in a broker or endpoint URL is sealed at rest, shown as********in the Studio and the API and as***in connection tests, events and logs; channel audit records carry no credentials. A telemetry subject now names the whole tag path whatever the inbound prefix, so eaxPLC’s multi-level prefixes are taken in. Switching a connection’s protocol away and back before saving keeps its stored credentials. Connections, lines and stations, upgrade notes 513 to 517 -
The audit trail in its own database, in Starter, Pro and Enterprise (11 November, breaking, safety: audit trail, authorization, commands to equipment):
audit.duckdbin the audit folder, separate from the historian, one committed transaction per record, each record on disk before the action goes ahead, no JSON or CSV copy. It starts fresh: an earlieraudit_ledger.jsonlis not imported and not read. The Free edition has no audit trail (the audit views answer403 NO_AUDIT_TRAIL; the AI co-pilot’s equipment actions and the genealogy purge are refused); the sign-in trail stays in every edition. A trail that does not open, or whose folder fails its system requirements (network share, RAM disk, under 10 GB free), is down: ALM-SYS-AUDIT-DOWN, actions that record first refused with503 AUDIT_NOT_WRITTEN, retried every 30 seconds; never a stopped server. New:eaxscada audit-set-aside(offline, e-signed) for a damaged file, a tip anchor that finds a cut-off trail, verified copies of the trail in server backups and restores, and paging and filters onGET /api/audit. Later the same day (e9926e8): the Free edition starts whatever the audit folder; the trail’s state is shown in Security > Operations audit, in a System Health Audit trail card and in the licence dialog; a licence installed over a kept trail records the Free gap (AUDIT_TRAIL_RESUMED); new system alarm ALM-SYS-AUDIT-DISK under 10 GB free. The audit trail on disk, When the audit trail is down, Audit trail API -
Batch records no longer claim an integrity check (18 November; safety: 21 CFR Part 11): no integrity check of batch records exists today, and the EBR now says so.
GET /api/batches/{id}/ebrcarriesintegrity{"status": "not_checked", "reason"}instead of the constantintegrity_valid: true, and the Studio’s badge reads Integrity not verified. The batch record’s integrity, upgrade note 547 -
Batch records written first, and a batch runs the recipe it was created from (19 November; safety: commands to equipment, batch records, 21 CFR Part 11): a batch command, prompt acknowledgement or creation whose record cannot be written is refused with
503 BATCH_NOT_WRITTENbefore any setpoint; PAUSE, HOLD, STOP and ABORT always take effect and their record is written again until it is (applied); a phase step that cannot be recorded holds the batch (held); a prompt acknowledgement on a paused or held batch is refused with409 BATCH_NOT_RUNNING. New system alarm ALM-SYS-BATCH-RECORD. Editing the master recipe no longer changes a running batch, and the EBR shows the recipe as run with its revision. The Studio shows each answer as what happened, never as success. The batch record is written first, A batch runs the recipe it was created from, upgrade notes 559 to 564 -
Batch records checked against their own chain and the audit trail, signatures and approvals bound to what they sign (19 November; safety: commands to equipment, batch records, audit trail, e-signatures, 21 CFR Part 11):
- Each batch record is a SHA-256 chain of entries, and each entry’s hash is in the audit trail. Every EBR is checked when it is opened:
validonly when all of it checks, otherwiseinvalidwith the first failing entry,partial,not_covered,not_anchoredornot_checked. - A step whose record cannot be written is refused (
503 EBR_NOT_WRITTEN), while stops still take effect. With the audit trail down, a running batch is held at its next step. - Release signatures sign the record as it was shown (
EBR_CHANGED,EBR_INVALID,EBR_NOT_CHECKED). The release closes the record: only signed post-release notes follow. - Recipe approvals are bound to the revision and content (
RECIPE_REVISION_REQUIRED,RECIPE_CHANGED), and an approved recipe whose approval does not hold is not run (RECIPE_APPROVAL_INVALID). - Records from earlier versions are
not_covered, and legacy signatures never count toward verified. - An Administrator can check every batch record (
POST /api/batches/verify).
The batch record’s integrity, upgrade notes 565 to 575
- Each batch record is a SHA-256 chain of entries, and each entry’s hash is in the audit trail. Every EBR is checked when it is opened:
-
Batch records replicate on redundant pairs, with their phase logs and signatures (19 November, Enterprise; safety: commands to equipment, batch records, HA, 21 CFR Part 11): the primary’s chain entries replicate synchronously on the cluster stream
EAX_HA_EBR. A forward step or signature the cluster does not acknowledge is refused (503 EBR_NOT_WRITTEN), while stops still apply and are sent late. The standby accepts only entries that link to its own chain and refuses batch steps (409 EBR_NOT_PRIMARY). After a failover, the new primary catches up before it runs forward steps, and entries recorded but never replicated are reported as missing, naming the node that recorded them. Phase logs and signatures now survive a failover. Redundant pairs, Batch records on a redundant pair, upgrade notes 576 to 581 -
The batch list shows each batch’s integrity, and a 2 s cap on the EBR check (20 November; safety: batch records, 21 CFR Part 11): only a check that covers the record as it is now reads Verified; a changed record reads not checked (
changed_since_check), a batch not checked since the startnever_checked. Administrators run Verify all batch records from the Studio. Recipes carryapproval_invalidand the recipe list is a data grid. The batch record’s integrity, upgrade notes 588 to 594 -
On a redundant pair, a batch step is acknowledged only once another running SCADA node holds its audit record (20 November, Enterprise; safety: batch records, HA, 21 CFR Part 11): after a failover every acknowledged entry is anchored on the new primary and reads valid once it has caught up; before, it could stay not anchored until the old primary came back. A running but unhealthy standby blocks forward batch steps until it is repaired or stopped, and a node that runs without answering raises
ALM-SYS-HA-AUDIT-UNCONFIRMED. Redundant pairs, Batch records on a redundant pair, upgrade notes 602 to 606 -
The PLC panel’s forces chip shows again (19 November): with a PLC selected, the forces chip beside the Studio’s PLC picker failed to draw; it shows FORCED, NO FORCES or FORCES UNKNOWN again.
-
Names and messages in Studio dialogs and toasts shown as text (18 November, every edition; security): names, ids and server messages in the Studio’s dialogs, confirmations and toasts are shown as plain text, never read as markup.
Collaboration (eaxCollab in the Studio)
Section titled “Collaboration (eaxCollab in the Studio)”- Comments pinned on screen elements, tags and PLC program lines.
- Review before deploy: request a review, approve with an electronic signature, one approver (Pro) or two (Enterprise), bound to the exact manifest; the Deploy dialog shows the server’s gate. Review screens and PLC programs before deploy, Design reviews API
- The AI assistant as reviewer of a deploy (8 November, Pro and Enterprise, safety): a project review can ask the AI assistant for an advisory check of what the deploy changes. Its findings appear on the review page and as comments on the screen elements, labelled AI · advisory; it never approves, decides or deploys. Approvers confirm they saw the findings before they sign. A project can require the check to have completed on exactly the manifest deployed; it is not required while the assistant is unavailable. Let the AI assistant check a deploy, The AI assistant’s check
- Search reviews and comments (8 November, Pro and Enterprise, safety): Deploy → Search reviews and comments… finds past reviews, signed decisions, comments and the AI assistant’s checks of a project or a PLC, by words, kind, author and dates, in a grid with CSV export; a result opens its thread or its review. You find only what you may read where it comes from: a comment on a screen needs that screen’s read right. The AI co-pilot account cannot search. Search reviews and comments, API
- The eaxCollab web inbox in five languages (18 November): English, French, German, Italian and Spanish, chosen on the sign-in page or in Me and remembered in this browser. The server’s refusals and the Daily digest‘s name follow the language; messages, cards and the meaning of approvals stay in their authors’ words, and what is signed is identical in every language. eaxCollab inbox language
- The eaxCollab Daily digest in the configured language (19 November): the server writes the digest in the language set by its flag
-digest-lang(en,fr,de,itores; defaulten); the inbox’s language picker does not change it. Refused agent requests are now written to the server log, never with their body. The Daily digest’s language, upgrade notes 557-558 - The eaxCollab inbox language follows the member, and the Daily digest uses it (20 November; security: service permissions): the language chosen in Me is kept with the member’s account on the server and applied at every sign-in, in any browser; a language picked on the sign-in page is saved only when the account has none yet. The digest is written in its recipient’s language (
-digest-langfor a recipient without one), with the audit chain’s reason translated too, andeaxcollabctl digest rungets its answer again while the archive is starting. Existing servers: reissue the gateway and digest identities before the start. eaxCollab inbox language, Upgrade an existing server, upgrade notes 582 to 587 - eaxCollab agents are told when a request is refused (20 November): the agent SDK’s
AwaitandCallend at once with a refusal error carrying the stable code instead of waiting for the deadline, and the sign-in card saves the language with one conditional request.
Platform
Section titled “Platform”-
A heartbeat for historian logging rules (17 November, every edition; safety: historian values operators see): an
ON_CHANGEorTRIGGEREDrule for one tag can havemax_interval_s(0.5 s to a day; 0 = none): when the rule has logged no point for that long, the tag’s current value is logged with its own quality. In the rules API and in the Studio’s rule form (Heartbeat). A rule’s heartbeat, upgrade notes 496 and 497 -
default_max_intervalnow logs steady tags (17 November, every edition; safety: historian values operators see): a tag with no rule gets its current value logged every interval even when no update arrives; a site with the key set gets more points, at most one per tag per interval. Tags without a rule, upgrade notes 498 and 499 -
Windows saves wait for an antivirus scan (17 November, every edition): a configuration or data save whose final rename is refused for a moment (“Access is denied”, a sharing violation) is retried for up to 2 seconds. Antivirus and the search indexer, upgrade note 500
-
The historian tells a refused point from an outage (18 November, every edition; safety: historian values operators see): when the store refuses a batch but takes a test write, the historian is “isolating” (
ALM-SYS-HISTORIAN-ISOLATING, Medium) instead of down, retries every 2 s and finds the refused point within seconds; with no point written for 30 s it is down (ALM-SYS-HISTORIAN-STORE-DOWN). A point is quarantined only once the store has written a later one, so a store that refuses every point no longer loses good points. The status and two new metrics show the state. The store’s state, upgrade notes 524 to 529 -
Repair a historian store or audit trail a checkpoint cut short (18 November, the release build, files without encryption at rest; safety: historian values operators see, the audit trail): a file that does not open after a power loss or a killed process during a checkpoint (its data intact, one block’s checksum wrong) can be repaired instead of set aside. A copy is checked block by block, the one checksum recomputed and every table read (the historian also compares its daily row counts with the latest snapshot; the audit trail verifies its hash chain and tip anchor); only a copy that passes is offered, and an administrator repairs it, e-signed. The original is kept (
*.torn-<UTC time>.duckdb, with a.repair.jsonjournal), the audit trail records both SHA-256, and the history or the chain stays complete. Historian: through the API for now, the System Health button follows. Audit trail:eaxscada audit-set-aside --repair. Nothing is ever repaired automatically. Repair a historian store file, repair the audit trail, upgrade notes 532 to 536 -
A historian write that hangs is reported down after 30 s (19 November, every edition with the columnar store; safety: historian values operators see): a write to the store that has not returned after 30 s raises
ALM-SYS-HISTORIAN-STORE-DOWN(down_reasonstalled), even with no refusal before it, and clears when the write returns. Before, the state stayedokfor as long as such a write hung. The store’s state, upgrade note 538 -
The historian finds a refused point by halving the batch (20 November, every edition with the columnar store; safety: historian values operators see): a point 1,200 deep in a batch of 2,000 is found in about 12 writes instead of about 1,200, so
ALM-SYS-HISTORIAN-ISOLATINGclears within one 2 s tick instead of a minute or more. The same points are written in the same order and the same points are quarantined; the state isokas soon as the refused batch is past. The status gainsisolation.search_to. The store’s state, upgrade notes 595 to 597 -
The historian repair, continued (18 November, the release build): the checks of the copy run in a separate process of the eaxScada program (read only, at most 6 hours each; a crash or hang refuses the repair, the server keeps running); copies left by a restart during a check are deleted at start; the start log says at once whether a store that does not open may be repairable;
GET /api/historian/storenames the repair’s e-signature decision. Repair a historian store file, upgrade notes 539 to 542 -
Linux and Docker packages give eaxScada 120 s to stop (19 November): the systemd unit (
TimeoutStopSec=120s, was 30 s) and the release’s Compose files (stop_grace_period: 120s, was Docker’s 10 s), and their configurations cap the historian store’s memory at 1 GB, so neither a stop nor a memory shortage kills the server in the middle of a checkpoint. Stopping without cutting a checkpoint short, upgrade note 543 -
A memory cap for every database store (19 November, builds with the columnar store; safety: historian, audit trail, every store): without a configured value, the historian takes 25% of the machine’s memory (512 MiB to 4 GiB), genealogy 1 GiB, alarms, the log console and OEE and downtime 512 MiB, and the other stores 256 MiB; a configured value always wins. A store without a threads setting uses one thread per 64 MiB of its cap, so a large statement and the checkpoint after it no longer fail. Past its cap a store spills to a
.tmpfolder next to its file, encrypted for an encrypted store, and the start log names each store’s cap. Memory caps of the stores, upgrade notes 550-554 -
A notice file after a historian restore or import (17 November): an archive restore, an import from the daily export or a CSV history import may leave
scada_history.bulk-notice.jsonin the historian folder; it is expected, read and removed by the server at a later start: do not delete it. The notice file after a restore or an import -
The historian keeps within its disk budget on a columnar store (15 November; safety: historian values operators see): the purge on a critically full disk now works there, without ever deleting more than room for about two days of new history; the pause counts the store’s free blocks; a config file without a budget is warned about at start;
historian:keys after an unread sub-section are read; shipped config files set a budget for new installs. Keep the historian within its disk budget, upgrade notes 379 to 385 -
Tag registration scales: 100,000 tags register in well under a second. Upgrade note 371
-
Project settings collected on one page. Project settings
-
Alarm definitions carried into Pro and Enterprise. The first start of a Pro or Enterprise server imports the Free or Starter file of alarm definitions once, validated; the report is in System Health for administrators. Move alarm definitions to Pro or Enterprise
-
Alarm store before live (2 November): an alarm definition change or a shelve the alarm store cannot write is refused (
503 ALARM_STORE_NOT_WRITTEN) and nothing changes; an unshelve always takes effect and is retried until saved; a shelve that expired while the server was stopped is dropped at start-up. New system alarms ALM-SYS-ALARM-STORE and ALM-SYS-ALARM-JOURNAL-LOST, the System Health blockalarms.storeand three metrics. Store before live -
No alarm event lost from the journal at shutdown (4 November, safety): the alarm engine now stops before the alarm journal closes, after the sources whose last events it journals. From the stop on, alarms keep their state and are shown suppressed with “server shutting down” (no new
TRIPorRTN); the next start evaluates the live values. An event still raised after the stop is logged at WARN with a count instead of being lost. The journal at a server shutdown -
The historian’s analytics export is Pro and Enterprise (2 November), and Free for evaluation: on Starter the export settings and the days already exported are read only, and files already exported stay after a downgrade. Which editions export
-
Starter templates use
Plant/...tag paths (2 November) instead of theSite1/example namespace; projects already made from a template are unchanged. Each tag and alarm a template adds has its own audit record. -
Unused broker buckets removed on upgrade; the display tree is read from disk only, so deleted folders no longer come back.
-
scada-clikeepsversionandhelponly. -
Modbus TCP gateway. Several devices behind one Modbus TCP gateway (energy meters, drives, RTUs) on one connection, one station per unit id; a device that does not answer makes only its own tags BAD. Lines and gateways list their stations, with their state, in a table on the Line or Gateway tab. Connections, lines and stations
-
Modbus block reads (14 November, safety: values operators see). Every Modbus channel reads neighbouring tags of one unit id with one request per block when the device has block reads on, takes each tag from its own offset, re-reads a refused block tag by tag, and never serves an answer from an earlier poll. New channel settings
block_gap_registersandblock_gap_bits. Read upgrade notes 345 to 349. Modbus block reads -
DF1 serial driver. Rockwell / Allen-Bradley MicroLogix 1000 to 1500, SLC 5/03 to 5/05 and PLC-5 through their serial port (DF1 full-duplex, on a COM port or a serial device server in raw TCP mode). One message per write, re-sent only after a NAK; a write without its reply is reported NOT CONFIRMED and never repeated. Tested against a simulator so far. Connect a DF1 serial controller
-
Omron FINS driver (28 October). Omron CJ2M, CJ2H, CS1, CP1E, CP1L, CP1H and NJ/NX controllers over FINS/UDP or FINS/TCP: CIO, W, H, A, D, timers, counters and EM by word or bit, BOOL to LREAL and STRING, neighbouring words read in one command, one command per write, never repeated. Tested against a simulator so far. Connect to Omron CJ2, CS1, CP1 and NJ/NX controllers (FINS)
-
Mitsubishi Electric MC protocol / SLMP driver (28 October). Mitsubishi Electric MELSEC iQ-R, iQ-F (FX5U, FX5UC, FX5UJ), Q with built-in Ethernet and L, binary 3E or 4E frames over TCP or UDP: X, Y, M, L, F, B, D, W, R, ZR, timers and counters, X and Y in octal on iQ-F, Bool to Float64 and String, batch reads, one command per write, never repeated. Tested against a simulator so far. Connect to Mitsubishi Electric MELSEC iQ-R, iQ-F, Q and L controllers
-
Omron NJ/NX over EtherNet/IP, variables by name. NJ501, NJ301, NJ101, NX701, NX502, NX102 and NX1P2 through the CPU’s built-in EtherNet/IP port: published global variables, structure members and array elements by name, BOOL to LREAL, the mapped type checked against the variable’s own, one request per write, sent once. No browse. Verified against eaxware’s simulator only. Omron NJ-series and NX-series controllers
-
Sparkplug B by the specification. A metric’s Quality property is applied; NDEATH and DDEATH make their values Bad (a late death with an older
bdSeqis ignored); a sequence gap makes the node Uncertain until its next birth; a birth replaces its metric list; NCMD, DCMD and STATE are never values. Browse offers fullspBv1.0/...addresses and a write reaches exactly that node or device. MQTT and Sparkplug B -
Simulated PLCs refused by default. An eaxPLC run by the eaxsim emulator says it is simulated; its values are refused (
Bad (source refused)) unless an Administrator accepts simulated PLCs in Tools > Simulated PLCs, and then every value, alarm event, trend and history sample from it is marked SIM. Accept or refuse simulated PLCs -
This server’s own driver devices are not taken for PLCs (4 November, safety): values a Modbus, S7 or other driver device of this server reads and publishes on the UNS are taken in at once, instead of waiting up to 5 s for a PLC announcement (the log no longer says “PLC sent values but said nothing about itself within the wait” for
DEV-LINE1-PLC). A PLC that announces itself with such a device’s id takes those paths, and a simulated one is still refused or marked. How a PLC is told simulated -
Each device polled at its own scan rate (28 October): the devices of a channel poll independently, a slow device no longer holds back the others, and the Link card shows each device’s set and measured rate. Scan rates
-
Text tags on FINS, MC protocol and OPC UA (28 October): String tags write text to these devices (they were refused), and FINS and MC protocol read the text back into the Tag Mappings grid. Text tags
-
Model packs in a high availability pair are installed on the active server and copied to the standby, checked file by file. Use the 3D asset library
-
Historian: a value written twice at the same timestamp is kept once, with the later value, and late (backfilled) samples appear in trends, history and exports. Historian
-
Historian quality of periodic samples (1 November): a periodic sample keeps the tag’s real quality (it was always stored Good), and a Bad trigger tag never fires a triggered rule. Quality of periodic and triggered samples
-
Historian keeps the points when it falls behind (2 November): points that find the ingest queue full wait in an overflow and are stored; lost points are counted, shown in System Health and raise the new system alarm ALM-SYS-HISTORIAN-LOST. When the historian falls behind
-
Historian memory levels off under load (8 November): points already in the store leave the in-memory cache once the tag has 600 newer stored points or they are older than 10 minutes; points no store took stay as before. Recent trends are still served from memory and older ranges from the store, with the same values and quality. The in-memory cache of recent points
-
Less memory, faster recent trends (9 November, safety: historian values operators see): with the columnar engine, a point the store took leaves memory at once and is read from the store; only points no store took stay in memory. Trend and history reads no longer wait for the historian’s writes. Measured on a workstation at 1,000 tag changes per second, a 10-tag trend of the last 10 minutes went from 1.87 s to 0.13 s with one viewer and from 4.87 s to 0.20 s (p50) with 50 viewers, and the server’s resident memory from about 1,075 MB to about 445 MB, most of the saving from the smaller NATS replay buffer below (at most 64 MB, each change on it once). Values, quality and the simulated mark are unchanged. With encryption at rest, CSV and JSON exports now include every day. The in-memory cache of recent points
-
CSV history read in one query (9 November, safety: historian values operators see): CSV history (from before the columnar store’s first point of a tag, or on an install that stores CSV only) is read with DuckDB’s CSV reader, all the tags of a request in one query; the built-in reader names the window’s days instead of listing every day folder (a 10-tag, 10-minute read of a 30-day, 200-tag store: 0.57 s to 0.02 s on a workstation, 0.17 s to 0.02 s on a dual-core thin client). Tags whose path is written quoted (an OPC UA path such as
"DB1"."Speed") now show their history. How trends read CSV history -
Every tag on the UNS once (9 November): every tag, eaxTags, internal tags and MQTT channels included, is published once on
uns.telemetry.<path>; a NATS channel reading another broker has its values republished there, and a channel disabled while running publishes its tags once as out of service. Alarm transitions are onuns.alarm.<id>.event. The placeholder subjectsscada.v1...andalarm.v1...are no longer published. The replay streamTELEMETRYholds at most 64 MB by default (nats.telemetry_buffer). Normalised telemetry subjects -
A diagnostic profile listener for support (9 November, off by default):
--diag-pprof-addr 127.0.0.1:<port>serves memory and CPU profiles on a loopback address only, never on the web port. Share a profile with eaxware support only: it shows tag paths and configuration. Command-line flags -
A verified nightly snapshot of the history (9 November, every edition, on by default; safety: historian data): at 01:30 the columnar store is copied to
./data/backup/historian, checked day by day against the store before it counts, and the last 2 are kept. A low disk skips it without touching older copies and raises ALM-SYS-HISTORIAN-BACKUP; a critically full disk stops it. With the server stopped,eaxscada historian-restore --snapshot <file>checks it (a dry run) and--confirmrestores it. The nightly snapshot -
The daily Parquet export on by default, with a way back (9 November, Pro and Enterprise, store without encryption at rest; safety: historian data): each closed day goes to
./data/historian_exportat 02:00 and is kept for the historian’s retention; a day the disk cannot take is skipped and raises ALM-SYS-HISTORIAN-EXPORT.eaxscada historian-restore --from-export <dir>imports it back, adding only the points the store lacks, so a second import changes nothing. Starter and encrypted stores rely on the snapshot. Scheduled export of closed days -
“History unavailable” instead of a shorter history (9 November, every edition; safety: historian values operators and the AI see): when the history store does not answer and no complete copy can,
/api/historyanswers503 history_unavailable, the AI assistant’s history tool returns an error, exports and backups fail the day, and trends keep their live samples under a “History unavailable” notice with Retry (and retry every 30 s). When the history store does not answer -
CSV history after a backfill, and tag paths sharing a CSV folder (9 November; safety: historian values operators see): after a late (buffered) sample into the CSV era, trends, reports and exports show the CSV history between it and the start of the columnar store again. Two tag paths sharing one CSV folder (such as
A/BandA_B) are both exported and backed up, and the folder is kept to the longer retention. Where a tag’s CSV history ends -
One store: no more CSV copy (10 November, every edition of the release build, Free included; safety: historian data): the historian no longer writes CSV partitions next to the columnar store, which is now the single store. At 1,000 tags/s the copy took about 7 GB of disk a day and most of the historian’s write time. A history read the store cannot answer says “History unavailable” (
503), never a partial series, and a restore writes the store only. CSV history from before the upgrade is still read. For files other tools can read, use the daily Parquet export (Pro and Enterprise). Builds without the embedded database keep their CSV store, unchanged. The Hive-partitioned CSV files -
Points wait in a spool when the store stops taking writes (10 November, every edition with the columnar store; safety: historian data): when the store refuses writes or does not open, new points wait on disk in
historian/spool, in order, and are written when it takes writes again (retried every minute). None is lost while the spool has room (historian.spool.max_size, 2 GB by default). New system alarm ALM-SYS-HISTORIAN-STORE-DOWN (high); System Health shows “store not taking writes - points kept in the spool” and a Spool row. Encrypted under encryption at rest. When the store does not take writes: the spool -
The nightly snapshot no longer skips on a merely low disk (10 November; safety: historian data): the snapshot and the daily export skip only when free space is under what they need plus the disk guard’s critical line (
historian.disk.critical_free), not the warning line. The nightly snapshot -
Import the CSV history into the store (10 November, every edition of the release build; safety: deletes operator-visible history after verification): with the server stopped,
eaxscada historian-migrate-csvmoves the CSV partitions of an upgraded install into the columnar store. Without--yesit prints the plan and writes nothing; with--yes(and--reason) it records the start in the audit trail first, imports the newest day first, verifies each day in the store and only then deletes that day’s CSV files. Points the store refused in earlier releases become visible (“recovered”); a day that fails a check is kept as CSV and stays readable. It resumes after a stop and never imports a day twice. Import the CSV history into the store -
The CSV history import from System Health (10 November, every edition of the release build; safety: deletes operator-visible history after verification): System Health > Historian storage > Review import… shows administrators the plan (days, size, disk needed, estimated time, the plan by day in a grid) and the rules, and starts the import with an e-signature: the signed-in administrator, a reason and the password. The audit record is written before anything starts. The same dialog shows the progress with Pause and Resume, the per-day results with the days kept for attention marked in their rows, and a summary. Retry kept days… plans the kept days again (a repaired file is read fresh; a folder still being written waits) and its audit record lists the retried files. One import at a time. Desktop and tablet; on a phone, use the command line. A run started from the studio records its end (
HISTORIAN_MIGRATION_DONEor_HELD), and a server shutdown finishes the day in progress instead of keeping it for attention. From System Health, Historian CSV import API -
Set a broken historian store file aside (10 November, every edition of the release build, stores without encryption at rest; safety: what operators see of the history): when the store file did not open at start, System Health’s Set the store aside… checks the file first. A file only in use by another process (a second server, a backup tool, an antivirus scan) is not damaged and is never set aside; a damaged one is renamed to
scada_history.broken-<UTC time>.duckdb, never deleted, after an administrator’s e-signature and the audit record. A new empty store opens and the points waiting in the spool are written to it, none lost. How to restore… then names the newest snapshot made before it (kept until the restore) and the command:eaxscada historian-restore --snapshot <file> --keep-currentbrings the history back and keeps the points written since. When the historian store file does not open -
Quieter storage log, shorter spool cause (10 November): the historian’s successful storage events (a snapshot written, a day exported, logging resumed) are logged at INFO, a failed snapshot at ERROR. System Health’s Spool row shows the store’s error short, with the store file’s name and no folder path. In the server log
-
The nightly snapshot once a day, and a fresh start after a set-aside (10 November; safety: historian data): a restart no longer takes another snapshot on the same day (before, every start after 01:30 took one, and with
keep: 2a few restarts pruned the days before). After a store set-aside the scheduled export and the snapshot run again on the new store, their old errors cleared; System Health’s Export error shows the short cause; the restore dialog names “the newest snapshot made before the set-aside”. The nightly snapshot, When the historian store file does not open -
Long trends show quality as it is (2 November): overridden values are Uncertain (dashed) and short overridden spells are kept when a long trend is downsampled; quality is classed by its OPC major bits. Quality in trends and downsampled history
-
Batch records without invented values (1 November): lots required for lot-tracked materials and checked against their pattern, actual amounts only from a Good measurement of the ingredient’s actual tag, unique batch IDs, no made-up unit. Record lots and measured amounts in batch records
-
No HA records at every start and stop of a single server (12 November; safety: audit trail): a server without an HA cluster no longer writes
HA_PROMOTEDwhen it starts orHA_DEMOTEDwhen it stops cleanly. A lease lost and taken back while it runs is still recorded; HA clusters record every promotion and demotion as before. HA panel -
Fewer needless failovers under load (16 November, Enterprise HA clusters; safety: HA, commands to equipment): a primary whose lease renewal landed although its reply was lost reads the lease back from the lease stream’s leader and keeps it when it is its own, same term, not expired; anything else demotes as before. The new key
nats.start_timeout(default10s) sets how long the server waits for its embedded broker at start, and a broker not ready in time is shut down first. How the primary keeps its lease, upgrade notes 459 to 462 -
The NATS server built into eaxScada is 2.15.3 (12 November): the message store (
data\nats) is opened as it is, and the previous release still opens it. Upgrade notes 305 and 306 -
The embedded database is DuckDB 2.0.0 (17 November; safety: every database store): files stay in the v1.0.0 format, so the previous release still opens them, and nothing is converted; a file in a format newer than 2.0’s is refused and left as it is; the historian’s encryption extension moves to
bin\historian_ext\v2.0.0\; analytics and report SQL follows DuckDB 2.0’s rules. Engine version and file format, upgrade notes 470 to 476 -
Database stores reopen after a failed write (16 November; safety: historian data, alarms, recipes): after a failed commit or an invalidated database (full disk, write-ahead log or I/O error, out of memory) the historian, alarms, recipes, log console, collaboration archive and shift log index close and reopen their file, with writes held meanwhile; System Health’s new Database stores section shows the engine and each store’s format and state. When a write leaves the database unusable, Database stores, upgrade notes 477 to 480
-
The embedded database is DuckDB 1.5.6 (12 November; safety: historian data, audit trail): a patch release of the same line, with the historian’s encryption extension in
bin\historian_ext\v1.5.6\. Every new database file is written in the 1.x storage format, so the previous release still opens it, and existing files are never converted. Upgrade notes 308 to 315
Part and lot genealogy (Pro, Enterprise)
Section titled “Part and lot genealogy (Pro, Enterprise)”- Part and lot genealogy (2 November): a new Genealogy workspace records parts and lots, what was built from what, operations and their results, in eaxScada’s own database, with a tamper-evident chain anchored in the audit trail. It works with any PLC and driver. Part and lot genealogy
- PLC handshake: a capture trigger per station event; the PLC gets its acknowledgement only once the record is synced to disk, or an error code saying why it was refused. The answers need the new role
Genealogy_Capture. Capture genealogy from a PLC - Search by ID prefix, unit pages, trace backward and forward, recall from a lot, exports to CSV and JSON lines (also of a time range) and print layouts. Trace, recall and export genealogy
- Retention per unit type, signed purge after an encrypted, verified archive, and offline commands to archive, restore and verify. Records are kept forever by default. Genealogy retention, purge and archives
- Parquet export in a Hive folder layout for analytics tools, off by default. Export genealogy for analytics tools
- High availability (Enterprise): records replicated to the standby, with
ack_durabilityto choose when the PLC is acknowledged. High availability - Scripts and the AI assistant read genealogy:
genealogy.findandgenealogy.tracein eaxTags scripts, four read-only MCP tools andresource://scada/genealogy/schema. Scripts and the AI assistant - API under
/api/genealogy. Genealogy API - The database file is updated every 5 minutes (18 November; safety: genealogy store): the store checkpoints every 5 minutes instead of every 10 seconds, so far fewer power losses can catch a checkpoint. Every acknowledged record stays in the journal until then and is replayed at start. Durability, upgrade note 537
Analytics and Reports (Pro, Enterprise)
Section titled “Analytics and Reports (Pro, Enterprise)”- Analytics and Reports (5 November): a new workspace to run reports and download them as PDF and Excel files. Reports read as the person who runs them: a report shows only the tags that user may read, and says on page 1 how many were hidden. Bad and uncertain values are always marked, a figure computed from several values is good only if all of them are, and simulated values are flagged. Nothing in a report writes. Pro and Enterprise only, not in the Free evaluation. Analytics and Reports
- Datasets: named read-only queries over the historian or the alarm journal, with a tag scope, parameters with defaults such as
yesterdayorstart_of_month(-1), the quality helpers (good_avg,agg_quality…), checks on save and a preview as you. Create a report dataset - Report mode in the designer: File > New Report… lays out pages with a header and footer, text, KPI tiles, tables with groups, subtotals and totals, charts and repeat groups; a preview with real rows; a PDF draft rendered by the server. Reports deploy with the project. Design a report
- Runs and files: run a deployed report for a day, follow it in the Runs tab, download the PDF and the workbook; every file is archived with its SHA-256 hash and checked before each download. Run a report and download the files
- Eight new rights, from
reports_viewtoreports_admin. Grant report rights - Reference: relations and columns, helpers, defaults, limits, template elements and placeholders, run records, routes and configuration keys. Analytics and Reports reference
- Schedules: reports that run on their own at a time (presets or a cron expression), at the end of each shift (
reports.shifts), when a batch ends or when a tag turns on, as their owner with the owner’s rights at each run; each slot runs once, also across a daylight-saving change and an HA failover; catch-up and grace after downtime; schedules restored from another server stay off. Schedule a report - Signed reports (Part 11): a signature plan per report (review, or review then approval, with roles, meanings and separation of duties); each e-signature adds a signed copy with a signature manifestation page, and the archived original never changes. Sign a report
- Archive: the Archive tab, Verify (the original, its run record and every signed copy), PDF/A-3b archived PDFs with the datasets’ rows embedded, a quota and a disk floor, a 3-year retention for unsigned reports, and a purge with a dry run and an e-signature; signed reports are never purged. Verify and purge the report archive
- Delivery: e-mail sent by eaxScada (a link by default, STARTTLS, the password stored write-only, allowed domains for addresses outside eaxScada) and files in allowed folders; signed reports go out once fully signed. Set up e-mail and folder delivery
- History kept only in the historian’s CSV files is now part of report datasets, with the trends’ rule. A report shows only what you may read
- The Analytics workspace (6 November): your own SQL over the historian or the alarms, run as you with your read rights, with a time window and parameters, results in the data grid with their quality marked (and Query ignores quality when a query reads values without it), charts (line, bar, scatter, pie, heatmap; PNG and CSV), personal saved queries and Save as dataset. Analyse data in the Analytics workspace
- Export whole results (6 November): the Export split button writes the whole result of a query, and the Datasets grid’s Export a saved dataset, as CSV, Excel (with an About sheet) or Parquet. The server reads the rows again with your read rights and writes the file itself; limits refuse an export, never cut it; files are yours only and kept 24 hours. Export analytics results
- Extracts across sources (6 November): read the historian’s samples and the alarm journal into extracts of your own in-memory session, with your read rights, then join them in one query with the source Extracts (this session); quality travels through the join. Bounded per user and server-wide. Combine sources with extracts and pivot on the server
- Pivot on the server (6 November): a result too large for the browser is grouped on the server into row groups and a pivot column (sum, average, minimum, maximum, count), through the normal query path. Pivot a large result on the server
- PDF/A validated (6 November): archived PDFs and their signed copies are validated with an independent PDF/A validator, PDF/A-3B profile; signed copies are now PDF/A-3b too, and about the size of the original plus the signature page. PDF/A with the data inside
- HA failover keeps every report (6 November): run records and archived files replicate to the standby; after a failover the new primary lists, serves, verifies and signs them, and delivers a pending signed report once. System Health shows the archive replication. High availability: run records and the archive
- Archived reports stay readable after a downgrade (6 November): a read-only workspace (Runs and Archive), Verify and the downloads; schedules pause and resume with the licence. After a downgrade or a licence expiry
- Pickers for schedulers and designers (6 November): the schedule editor offers users, folders and options, and the signature plan offers role names, to non-administrators too; the Runs list shows each run’s signature status as the server decides it. Times labelled UTC are shown in UTC. Set up e-mail and folder delivery
Shift log (Enterprise)
Section titled “Shift log (Enterprise)”- The signed shift log (14 November, Enterprise only; safety: authorization, e-signatures, audit trail): a Shift log panel in the operator runtime where each line or area keeps its own log of notes, deviations, maintenance, safety items and standing instructions, with references to tags, alarms, batches and screens and what they showed at that moment. Every entry is a record in the audit trail; deviations, safety items, instructions and corrections and closures of signed entries are password-signed, notes and maintenance attributed (a log may require a password). Entries are never edited or deleted: corrections, voids and closures are new entries. Open items carry over from shift to shift. Write in the shift log and hand over a shift
- Signed handover: the outgoing operator signs a summary and a status line per open item, the incoming operator co-signs the same content in their own session or at the same console; a shift without a completed handover is recorded as missing (a notice, not an alarm). The signed shift log
- Studio settings: Project > Shift log… for the logs, their shift calendar (
reports.shifts), who may read, write, sign and review, the entry types and the handover settings; five new rightsshiftlog_viewtoshiftlog_admin. Set up shift logs - Shift report: the starter report “Shift log report” and the schedule trigger After each shift handover in Analytics and Reports. Set up shift logs
- Add to shift log from an alarm (row action and detail card; it acknowledges nothing), from the operator faceplate, and with the screen-script function
system.shiftlog.add: the entry dialog opens with the reference attached, and the operator records. Add to shift log - API under
/api/shiftlog. Shift log API - Period export (16 November; safety: audit trail, authorization): a log administrator exports one log’s records for a period (at most 366 days) as a ZIP file of the entries, their audit records and a manifest with the SHA-256 of each file, from More > Export period… in the runtime panel or with
POST /api/shiftlog/exports. The export is recorded in the audit trail before the file is sent. Export a period - Security review fixes (15 November; safety: authorization, e-signatures, audit trail): a draft is recorded once, changing the settings needs
shiftlog_adminas well as the engineer level, a catch-all DENY refuses every shift log and Analytics and Reports right, instructions are closed or corrected by a reviewer or their author, verification is rationed and the audit trail’s chain is for administrators, and script dialogs open one at a time after a click. Upgrade notes 350 to 363 - Signatures and fields per entry type in the Studio (16 November; safety: e-signatures): Project > Shift log… has a password-signature switch for notes and another for maintenance, and a grid of the fields of each entry type (name, label, kind, required, choices, order). A signature asked for when an entry was prepared is required when it is recorded, even if signing was switched off in between. Signatures per type, Fields per type, upgrade notes 431 to 435
- Verify an export (16 November; safety: Part 11 records, authorization): every reader of a log checks a period export, the ZIP or its manifest alone, against the server’s audit trail, from More > Verify an export… in the runtime panel or with
POST /api/shiftlog/exports/verify. The report names each check (recorded, manifest, files, records in the trail, the trail reproducing the export), and the verification is recorded asSHIFTLOG EXPORT_VERIFIED. Verify an export, Export verification, upgrade notes 436 to 440
OEE and downtime (Pro, Enterprise)
Section titled “OEE and downtime (Pro, Enterprise)”- OEE and downtime (17 November, Pro and Enterprise; safety: values operators see, authorization, audit trail): machine states, downtime events and OEE worked out from what the historian logged, for any machine and any PLC. It only reads: it never writes a tag or sends a command to a machine. Off by default (
production.enabled). OEE and downtime - Machines in the Studio: Analytics and Reports > Production for machines (state from a state code map, PackML, conditions on tags or the counter; two of total, good and reject; fault code and product), reason codes, production plans with breaks and exceptions, ideal cycles per product and the settings, with in-grid warnings, and Apply logging rules for the historian logging the source tags need (preview first). Set up OEE and downtime
- The Downtime panel in the operator runtime: the state now, the shift’s availability, performance, quality and OEE with their data quality, the stops with Reason needed markers, the reason dialog with the machine’s suggestion (never pre-selected), and an e-signature for a change after the shift closed. The screen action Open downtime panel opens it. Enter downtime reasons
- Planned stops, count adjustments and recompute with a preview, recorded in the audit trail. Record planned stops, adjust counts and recompute OEE
- Reports and dashboards read the results through the new dataset family
productionand its helpers (prod_oee,prod_row_quality…). Dataset family production - Seven new rights
production_viewtoproduction_recompute, an API under/api/production, HA replication of the results and the system alarmALM-SYS-PRODUCTION. OEE and downtime reference, upgrade notes 501 to 512 - Before going live (18 November, eaxScada 041a1be2; safety: audit trail, authorization): a recompute is refused without its preview; configuration saves are recorded before they are saved; a recompute’s outcome is recorded (
RECOMPUTE_COMPLETEDwith the rows and the sums before and after per shift, orRECOMPUTE_FAILED); Add OEE datasets in Analytics and Reports > Schedules adds ten starter datasets. Starter datasets, upgrade notes 518 to 521 - Automatic reasons and provisional stops in the Downtime panel (18 November, eaxScada 63fccf8c): a cause the machine reported is shown in the Reason column with an amber automatic tag and an Automatic reason marker; the stop still counts as without a reason until someone confirms it. A stop still being computed has a Provisional tag and marker. The CSV export always carries the Automatic reason column (the machine’s code) next to Reason (the reason in force). Automatic reasons
- Fault code logged just after the stop (18 November, eaxScada 0e87fc4a; safety: values operators see): a stop with no fault code and no alarm at its start now gets its suggestion from the first mapped fault code logged in the 2 s after the start, while the stop lasts, for PLCs that write the code a moment after the state. It stays a suggestion even when the machine accepts suggestions without confirmation. Stop times, categories and every OEE number are unchanged. OEE and downtime
Upgrade notes: what now behaves differently
Section titled “Upgrade notes: what now behaves differently”Writes and safety:
- A write to a tag that does not exist is refused (
404 unknown_tag), over HTTP, NATS and for assistant setpoints. Before, it created a memory tag and answered200. Define such tags as eaxTags. - A simple screen interlock is enforced by the server (
409 interlocked) for every writer, signed or not. Check that each stop command has no interlock, or that its Bad-value setting is Allow. - Out-of-range writes are refused for every writer: input limits, faceplate setpoint limits (screens and dashboards), the tag’s write range and the engineering range (now also over NATS and for assistant setpoints).
- An input object’s confirmation or signature is required by the server for every writer of its tag; commands inside groups now get the signature and confirmation they ask for.
- A write without a value is refused (
400); it used to write 0. - A bound limit tag that is missing or not Good refuses every write (fail closed).
- Text is written only to String tags, and numbers only to the others.
- A Faceplate’s interlock tag is enforced on the operator faceplate and by the server, and it is active when not 0: a value of 2, -1 or true now blocks the setpoint (before, only exactly 1 did, and the server did not check it). A missing or Bad interlock blocks unless a Bad value is allowed. A faceplate without an interlock tag never lets a value through another object’s interlock on the same tag. Enforce interlocks
- A button’s Bind-tab Disabled interlock (
bindings.disabled) now disables the button and is enforced by the server; it used to do nothing. - A Toggle button writes the opposite of the live value, and refuses when that value is unknown, not Good or changed while the operator was asked. The first Toggle after a page load used to write 1 whatever the plant read.
- Dashboard command cards (push button, batch reactor, pump, PID controller) have their own Confirmation and Interlock tag, required by the server for their tags (
403 confirmation_required,409 interlocked). The reactor’s E-STOP is exempt. Manage dashboards - Acknowledgements from the alarm card and the data table go through the acknowledgement dialog (reason required, the signer is the signed-in user). The alarm card’s ACK ALL is replaced by ACK VISIBLE (n): only the unacknowledged alarms the card shows.
- No pre-filled signature meaning. New buttons save none; the stock texts older versions saved count as empty, and the meaning signed is what is sent (“write 1 to …”), unless the engineer wrote one.
Deploy and runtime:
- New projects have live editing off: saves wait for Deploy; a never-deployed project shows no operator screens until it is deployed. Existing projects keep it on.
- The automatic deploy runs the same checks as Deploy and is refused (journaled
AUTO_DEPLOY_REFUSED) when one fails. - The runtime draws deployed screens and dashboards only; a page, dock or popup of an undeployed screen or dashboard shows “This screen is not deployed.”
- The write policy is the strictest of the deployed and saved copies: removing protection takes effect at Deploy.
- An unknown route or screen id says “not deployed” instead of opening the startup page.
- Applied AI screen proposals wait for an explicit Deploy.
Display and objects:
- A colour condition that reads a Bad value is not applied: the object is neutral grey with a red marker; a Bad interlock disables its command; Uncertain values are shown with an amber
?. - A disabled or locked button shows its disabled colours as well as the dimming, and says why in a tooltip.
- The alarm banner’s Ack opens the acknowledgement dialog (reason required); the banner’s area filter matches whole folder names.
- Ctrl+click in the designer selects; only Alt+click runs an action.
- Web content runs in a sandboxed frame: its HTML and scripts no longer see the operator page, its session, cookies or storage, and cannot send requests; they receive tag values one way. Content that used page functions must be rewritten. An iframe address must be http(s). Web content
- Map tiles are a project setting (Project manager, Map tiles), none by default: a map shows its markers on a blank background and no operator browser calls the internet until a tile source is set. Map
- The video object refuses rtsp:// and other non-HTTP addresses with the reason, and says NOT PLAYABLE for a source the browser cannot play.
- A MultiState indicator’s list of states moved to
msStates; screens saved before are migrated when read and draw as before. A new indicator starts with neutral states. - A group draws nothing of its own: its size is its objects’ bounding box, with no fill or stroke over its objects.
- Paste special starts as a no-op; a rule that strips a folder from every tag is applied only after a confirmation.
- A new installation has no sample components; components already saved in a data folder are kept.
Accounts, AI and integrations:
- AI co-pilot accounts and API-token clients may use the MCP gateway only, cannot save screens directly (they propose), never sign and never get a PLC token.
- Disabling or deleting an account revokes its API tokens.
- Dashboards: creating one needs a name; deleting one in use answers
409; deleting a missing one404. scada-clilost itstags,alarms,historyandprojectcommands: use the HTTP API with an API token.- Unused broker buckets (
scada_displaysand four others) are deleted once at the first start.
Screen access, signed deploys and alarms (11 October):
- A screen’s Required Access Level is enforced. It used to be stored and read nowhere. A user below the level no longer gets the screen: it is left out of the runtime’s screens and menus; a link, address, page, dock or embedded copy shows You don’t have access to this screen, and a popup of it is refused with the same words (it used to open). Check every screen’s level before upgrading.
- A restricted screen’s commands count only for users at or above its level. A write naming the screen from a lower user is refused (
403 screen_access_denied,WRITE_DENIED_SCREEN_ACCESS), and its unblocked commands no longer let a lower user’s value past another object’s interlock. Writes over NATS count only the commands of screens with no restriction. - A Compliance_Auditor (level 20) is below “Shift_Operator and above” screens, and the AI co-pilot account (level 10) reads only screens with no restriction, in the Studio and through the assistant’s screen tools (
scada_get_screen,scada_list_screens,scada_propose_screen). - Reading a screen in the Studio above your level is refused (
403) below Lead_Engineer; engineers and administrators read every screen. - An unknown stored level means Administrator only (lint
screen-access-unknown). - Telemetry Streaming Mode is removed from Display Settings; it did nothing.
- New projects require an e-signature to deploy. The Deploy dialog asks the deployer’s password; API tokens and the AI co-pilot account can no longer deploy such a project; with live editing on, saves wait for a signed Deploy. Existing projects keep deploying without a signature until the setting is turned on.
- Turning “Require e-signature to deploy” off needs the engineer’s e-signature, and every change is journaled.
- A Pro or Enterprise server imports
alarm_definitions.jsononce when its alarm database has never held alarms. Shelves are not carried over (shelved alarms come back unshelved). A database that held alarms is never merged with the file. - A Pro or Enterprise server refuses to start when its alarm database is empty and
alarm_definitions.jsoncannot be read: fix or remove the file. - eaxPLC enforces its own deploy settings on every program load, including deploys eaxScada forwards; see What’s new in eaxPLC.
- The AI assistant and MCP no longer trim whitespace from PLC source they deploy: the bytes deployed are the bytes reviewed. A program that only matched its review after trimming now needs a review of the exact text.
- A PLC token issued at sign-in is now also accepted by
POST /api/collab/plc-approval(besides the AI assistant’s routes); nothing else accepts it.
Drivers (11 October):
- Existing Modbus TCP connections are unchanged on the wire: every request still goes to the connection’s unit id, byte for byte as before, whatever their device’s station field holds. Only a connection created or saved as a Modbus TCP gateway (
"gateway": true) sends each station’s unit id. Modbus TCP channels now also report Link diagnostics (linkinGET /api/dev/driversand in the driver diagnostics). - A Modbus TCP gateway refuses a station id that is not a unit id 1-247 (its tags are BAD, its writes refused with nothing sent) and unit id 0 (broadcast). A gateway with stations cannot be saved as a Modbus TCP device connection.
- Modbus TCP channels accept
timeout_msin their settings (100 ms to 30 s) to bound each request. Without it the timeout is 2 s, unchanged.
Editor, historian, alarms and 3D (27 October):
- The same timestamp written twice is kept once, with the later value, in the memory cache, the store, the history API and exports. Before, which of the two was shown could depend on where it was read from. Backfilled samples are written to a
late.csvnext todata.csvin the partition folder and are read with it. - The runtime’s backup alarm horn (used when the main alarm sound is not available) follows the one-beep rule: one short beep per activation of an alarm without acknowledgement, as the main horn does.
- The designer’s live preview never changes the screen. Animations, bindings and live multi-state values shown while previewing are no longer saved, exported or recorded in the history; edits made during the preview are saved and undone exactly.
- 3D model packs are replicated in a high availability pair. Install, replace and uninstall a pack on the active server; the standby refuses these with a link to the active server. Packs are not in project checkpoints.
- The 3D palette’s My models lists only the models you added; built-in models moved to the kit groups of their category.
- Ctrl+N opens New of the workspace shown (an alarm in Alarms, a recipe in Recipes, a connection in Drivers, a scene in 3D); it used to open a new screen everywhere.
Drivers (28 October):
- Each device is polled at its own scan rate. Every channel used to be polled on a fixed 100 ms cycle, whatever its devices’
scan_rate_ms. A device set to 250 ms (the Studio’s default for a new connection) is now polled every 250 ms, a device without a scan rate every 100 ms as before: lower the scan rate of a device whose values must update faster, and raise it on slow serial lines. Scan rates - Text writes reach FINS, MC protocol and OPC UA devices. A String tag’s text write used to be refused for any device with a station id, which every connection created in the Studio has; it is now refused only on station-addressed drivers (serial lines, buses, gateways). Check the write range (Longest text, Only these texts) of String tags on these connections before upgrading.
- A link error stays shown until that unit answers again, plus a 3 s hold, and each unit keeps its own error, so the Link card no longer flickers between errors.
Audit trail, historian, batches and remote access (1 November):
- Replaced by note 273: the audit trail is no longer a JSON file and
audit_ledger.jsonlis no longer converted; the release starts a new trail inaudit.duckdb. - Replaced by note 278: a trail that does not open no longer stops the server: it runs with the trail down (
ALM-SYS-AUDIT-DOWN) and refuses the actions that record first. Do not edit, move or replace the trail while the server runs. - Recipe and batch actions refuse when their audit record cannot be written: approval, batch creation, START, RESUME, RESTART, RESET, the release signature and a signed download. PAUSE, HOLD, STOP and ABORT always act.
- Lots are required. Every ingredient of an existing recipe is lot tracked, and a batch is refused until each lot-tracked material has a lot (lots used to be made up). Untick Lot tracked for materials without lots before production; integrations must send
lot_numbers. - Lot patterns are enforced, and a recipe with a pattern that is not valid cannot be saved. The old placeholders (
LOT-####and the former example patterns) are ignored. - Batch records show measured amounts only. An ingredient without an Actual tag is recorded as not measured; existing records show “not measured”. In the batch JSON,
actual_amountandin_tolerancecan benull, and an ingredient withoutmeasurementwas not measured. - A batch ID in use is refused (it used to overwrite the other batch); left empty, the server assigns a unique one. A batch with no unit records none (it used to record “Reactor 1”).
- Periodic historian samples carry the tag’s quality: queries and reports that keep only quality 192 leave the Bad and Uncertain periods out. A triggered rule no longer logs while its trigger tag is Bad.
- Translations, UDT instantiation, starter templates and deleting the active project are refused through remote access while a review reason holds (Enterprise, Co-sign remote deploys, or a project that requires an e-signature to deploy). Translations can be requested for approval, the others are made on site.
- Remote changes that act on the plant can be approved on Pro and Enterprise instead of being refused; on Starter they stay refused. A remote Test connection no longer needs a review, and is refused on a channel disabled on site.
Part and lot genealogy (2 November):
- Grant the genealogy handshake. Before a PLC can get its genealogy acknowledgement, create the role
Genealogy_Captureand give it a topic write (publish) ALLOW rule on that PLC’s Ack and Err tags. Without it no answer is written; a DENY rule matching the tag wins. Check in Genealogy > Capture and configuration lists the handshake tags and grants. Grant the Genealogy_Capture role - Back up
data/genealogywhole: the journal files (genealogy-journal-*.gjl),genealogy.lock,settings.jsonand the purge archives inarchives/. The PLC is acknowledged once a record is in the journal, before it is in the database, and after a purge the archive is the only copy of the removed records. Only one server process may open the folder. - Keep the recovery key’s private file. A purge is refused without a recovery key, and without its private file the purge archives cannot be read or restored.
- Genealogy settings are per server.
data/genealogy/settings.json(pseudonymise_operators,duckdb_memory_limit,ack_durability,retention,hive_export) is not replicated: on a high availability pair, set it the same on both servers. A change applies at the next start. - Choose
ack_durabilityon a high availability pair, on both servers:replicated(the PLC acknowledgement waits up to 2 s for the standby),local, or leave it out (replicated while a standby is heard). Any other value,autoincluded, is refused. While ALM-SYS-GENEALOGY-REPLICATION is up, acknowledgements are local only. - Records are kept forever until you set a retention per unit type (at least 365 days). The Parquet export folder, if you switch it on, is not encrypted and is not purged: set its access and retention on site.
- Go memory limit. The server now sets a soft limit on its Go heap:
--go-memory-limitdefaults toauto(40% of physical memory, at least 2 GiB); aGOMEMLIMITenvironment variable wins when set. Give a size (4GB), a share (30%) oroffto change it. Command line - Genealogy is read-only after a downgrade. When the licence no longer includes genealogy, records stay readable and exportable, but captures and records are refused and the PLC handshake answers error 6.
Audit trail, rights and historian (2 November):
- Check custom roles and DENY rules for
recipe.*andbatch.*before upgrading. Recipe and batch actions now follow the rightsrecipe.edit,recipe.approve,recipe.download,batch.runandbatch.sign, held from the Process_Supervisor level (60). A custom role holds them by its level; an ALLOW rule does not grant them below level 60. A feature rule that denies one, such asbatch.*orrecipe.*, now refuses those actions (403) for every role, group or user it matches, except the Administrator. Built-in roles keep their access. Who may change recipes and run batches - Integrations now see
503or403instead of400. Creating a batch, sending a batch command or saving a recipe answers503 AUDIT_NOT_WRITTEN(was400) when the audit trail cannot be written, and403when the right is missing. Treat503as “nothing changed, retry once the trail is back”. - More actions are refused without their audit record (
503 AUDIT_NOT_WRITTEN): project files and assets, dashboards (also a card save, now recordedDASHBOARD UPDATE), translations and styles, collaboration reviews and claims, account and role administration, tokens, signatures, server files, deploys let through by a review and the PLC safety-target lists. A signature whose record cannot be written answers503, not401or403. Recorded first, refused without the record - Server files write two records per change: the intent (
WRITE,DELETE,MKDIR,ROOT_SAVE,ROOT_DELETE), then<OP>_DONEwith the size and SHA-256, or<OP>_FAILED. Reports that countSERVER_FILESrecords see two rows per change. DEPLOY_REVIEW_SATISFIEDis written before the deploy it lets through (it was written after); reports that read its time now see it before the deploy record.- Starter-template recipes are saved as the user who applies the template, who needs
recipe.edit; each is recordedRECIPE_SAVED. - Long trends show overridden periods as Uncertain (dashed), and quality codes by their OPC major bits: a non-standard code of 192 or more whose bits read Bad no longer draws as Good and no longer fires a triggered rule. Stored samples are unchanged.
- Watch ALM-SYS-HISTORIAN-LOST. The new High system alarm says the historian could not store some points: read
last_loss_reasonin System Health. “Points written” now counts only points actually stored. When the historian falls behind
Alarm store, deploys, templates and the analytics export (2 November):
- Starter sites that use the historian’s analytics export must move to Pro. On Starter, new exports stop (scheduled and manual) and changing the export settings is refused (
403, codeEDITION). Files already exported stay where they are, untouched; history stays readable. Which editions export - Watch the new system alarms ALM-SYS-ALARM-STORE and ALM-SYS-ALARM-JOURNAL-LOST. ALM-SYS-ALARM-STORE means the alarm store refuses writes (definition changes and shelves are refused) or an unshelve is not saved yet; ALM-SYS-ALARM-JOURNAL-LOST means alarm journal events were lost from the stored journal. Check System Health (
alarms.store, with the last error) and the server log; free disk space is the first thing to check. Store before live - Starter templates now create
Plant/...tag paths, notSite1/.... Projects already created from a template are unchanged. If you add read (subscribe) rules for a project made from a template after the upgrade, write them forPlant/(for examplePlant/Processing/>). - A shelve is refused when it cannot be stored. Operators then get an error and the alarm stays shown (
ALARM_SHELVE_FAILED). Before, such a shelve held for the session only and was answered as made. Tell operators that a refused shelve is not in effect. - Integrations that change alarm definitions (
POST/DELETE /api/alarms/definitions) now get503 AUDIT_NOT_WRITTENwhen the audit trail cannot be written, and503 ALARM_STORE_NOT_WRITTENwhen the alarm store cannot write the change: in both cases nothing changed. Audit queries find these changes asALARM CREATE,UPDATEandDELETErecords from this release on; there are none for earlier changes. - Integrations that deploy (
POST /api/dev/projects/{id}/deploy) now get503with"code": "AUDIT_NOT_WRITTEN"when the audit trail cannot be written: nothing was deployed and operators keep the previous version. Treat it as “retry once the trail is back”. Audit queries that count deploys byDEPLOY_SIGNEDorDEPLOY_REVIEW_SATISFIEDshould countDEPLOY(the intent) orDEPLOY_DONE(went live) instead: every explicit deploy now writes both. Automatic deploys without a review gate appear asDEPLOY_AUTO_DONEandDEPLOY_AUTO_FAILED. Recorded first, refused without the record - Integrations that shelve alarms or change alarm definitions now get
503with"code": "ALARM_STORE_NOT_WRITTEN"when the alarm store cannot write the change (was400for a shelve,500for definitions). Nothing changed: the alarm stays shown, the definitions are unchanged. Treat it as “retry once the alarm store is back” (ALM-SYS-ALARM-STORE, item 88).
History values the AI assistant reports (2 November):
- Integrations reading history buckets (
scada_query_tag_historywithbucket_seconds, and the free-SQL average answered without the columnar engine) must handle an empty (null)avg,minandmax(andavg_value): a bucket with no Good sample has none. Values change where Bad, Uncertain or overridden samples were present, since they are no longer averaged in. New fields:quality,good_count,uncertain_count,bad_count,first_quality,last_quality,buckets_not_good(andavg_overin the free-SQL answer); none removed. Treat a bucket whosequalityis notgoodas not a plain reading. Data quality in the values the assistant reports
Free historian SQL, reverts, restores, the plant e-stop tag and the audit trail (3 November):
- Integrations and assistants using free historian SQL (
scada_query_historian, also throughPOST /api/mcp/tools/call) get a newwarningfield when the query readsvaluewithout selecting or filtering onquality, and aquality_class(or<alias>_quality_class) on each row that carries a quality code. The SQL is never rewritten and no field was removed, but a client that copies every column of a row now also getsquality_class. Treat an answer withwarningas unchecked, never as a plain reading, and add the good-quality filter(quality % 256) >= 192 AND quality <> 512to averages, minimums and maximums. Quality in free SQL answers - Checkpoint reverts can be refused with
503 AUDIT_NOT_WRITTENwhen the records of their alarm definition, alarm class or e-stop changes cannot be written: nothing changed (CHECKPOINT_REVERT_REFUSED). Sign and revert again once the trail is back. A restored server backup in the same case is not applied at start-up but waits, and is applied as soon as the trail can be written. Audit queries find these changes asALARM CREATE/UPDATE/DELETE,ALARM_CLASSES …andPROJECT PLANT_ESTOP_TAGrecords whose reason names the checkpoint or backup; there are none for earlier reverts and restores. Records written before a revert or restore - Changing the plant e-stop tag can be refused with
503 AUDIT_NOT_WRITTEN(project save, activation, deleting the active project, a deploy that moves the live signal) when itsPROJECT PLANT_ESTOP_TAGrecord cannot be written: the setting is not stored and the signal does not move. An automatic deploy in that case is refused (AUTO_DEPLOY_REFUSED), operators keep the previous screens, and it is tried again at the next load. Plant emergency-stop signal tag - Applying a starter template can now be refused with
403anddenied_tagswhen one of its alarms names a tag (alarm tag, ack, shown or PLC ack tag) the user may not read: nothing is applied and nothing is recorded. Give the user read rules for the template’s area (for examplePlant/Processing/>), or let a user who may read it apply the template. A template alarm whose controller handshake does not check is no longer added; the answer lists it as failed. - A chain check can fail with the reason
unreadable(the audit database cannot be read): treat it as a tamper or disk finding. Text that is not valid UTF-8 is recorded with U+FFFD. (The memory window this note described is gone with the audit trail database: note 289.) How verification works - Replaced by note 289:
security.audit_memory_recordsandsecurity.audit_memory_bytesno longer apply. A negative or unreadable value, ornone,unlimitedorofffor the size, still stops the server at start (“audit ledger settings refused”). Audit trail memory - Integrations reading
GET /api/auditcan get500with an error when the audit trail cannot be read, where they used to get a shorter list that looked complete. A server backup in that case fails (BACKUP_FAILED, the backup alarm) instead of holding a short trail. Treat both as a tamper or disk finding: run Verify in Security > Operations audit (the chip shows Unreadable from #N) and do not edit or restore the trail’s files. The audit trail on disk
The plant e-stop signal on deploy, and the unreadable audit trail (3 November, continued):
- Audit reports that pair the plant e-stop change with a deploy must follow the new record order. A deploy that moves the signal now records
DEPLOY,PROJECT PLANT_ESTOP_TAG,DEPLOY_DONE(wasPROJECT PLANT_ESTOP_TAG,DEPLOY,DEPLOY_DONE); an automatic onePROJECT PLANT_ESTOP_TAG,DEPLOY_AUTO_DONE(under a review gate:DEPLOY_REVIEW_SATISFIED,PROJECT PLANT_ESTOP_TAG). Read the e-stop change as the record afterDEPLOY(or beforeDEPLOY_AUTO_DONE). A deploy that fails after the move addsPLANT_ESTOP_TAG_FAILED(the signal moved back). Integrations that deploy can get409when the current signal was set between the checks and the move: nothing was deployed and the signal did not move. Record sequence of a deploy - More readers answer
500on an unreadable ledger file. Integrations callingGET /api/xref/uses?kind=usermust treat500as “the trail cannot be read in full”, never as an empty or complete list. Genealogy Verify (POST /api/genealogy/verify) now answers500with"status": "anchors_unreadable"and"ok": false: treat it as not verified. Monitoring that readsGET /api/system/health/hamust handle the newaudit_trailobject (readable,error) andwarnings; readers ofGET /api/system/health/backupmust checkhistorian.last_restore_readablebefore trusting an emptylast_restore(false: a restore may be missing; the reason is inlast_restore_error). System Health
Linux packaging (3 November):
- On Linux, eaxScada and eaxPLC install from a release archive with one layout: services
eaxscadaandeaxplc(the unitseaxscada-proandeaxscada-communityare gone: the licence sets the edition), userseaxscadaandeaxplc, programs in/opt/eaxware/<product>/bin, configuration in/etc/eaxware/<product>, data in/var/lib/eaxware/<product>, the console log in journald. The container images use the same paths inside (volumes at/var/lib/eaxware/<product>/dataand/logs, the same volume names as before). An installation of the older layout is reported byinstall.shand moved only with--migrate, which never deletes data; scripts, monitoring and backups that nameeaxscada-pro,/opt/eaxscadaor/var/lib/eaxscadamust be updated. Upgrade from the earlier Linux layout
Simulated PLCs and Sparkplug B:
- Values from a simulated eaxPLC are refused by default (
plc.accept_simulated: false). A test bench where eaxsim feeds this server reads those tagsBad (source refused)after the upgrade: accept simulated PLCs in Tools > Simulated PLCs (an Administrator, with a reason) for commissioning, and refuse them again before production. The historian table and the alarm journal get asimulatedcolumn at the first start, and the CSV partitions and exports a 6thsimulatedcolumn; an older release ignores them. After a restart, a real eaxPLC’s first UNS values can appear up to one heartbeat (2 s) later. Accept or refuse simulated PLCs - Sparkplug B values can now read Bad or Uncertain. A metric its edge node sends as Bad, the metrics of a dead node or device, and a node’s values after a sequence gap no longer read Good. A metric no longer in the latest birth reads Bad and cannot be written. Map Sparkplug B tags by the full address that Browse offers: a bare metric name that two nodes or devices share is refused as ambiguous. MQTT and Sparkplug B
Log file:
- A log file that cannot be written now stops eaxScada at start. Before, the server ran without a log file and logged a misleading syslog error. The log file is now set by
logging.file(EAX_LOG_FILE; defaultlogs/eaxScada.logunder the work directory,/var/lib/eaxware/eaxscada/logs/eaxScada.login the Linux packages) and switched off bylogging.file_enabled: false(EAX_LOG_FILE_ENABLED=false). Before upgrading, check that the log folder is writable by the server’s account; under systemd a folder outside/var/lib/eaxware/eaxscadaneeds aReadWritePaths=drop-in. Log file
Broker watchers, local driver devices and background requests (4 November):
- An eaxsim host on eaxScada’s broker needs a watcher identity for its UNS prefix guard. Without one the guard cannot connect or subscribe, fails closed, and every simulated PLC’s UNS telemetry and commands are refused. Make a seed (
eaxscada --gen-device-seed <file>), start eaxScada with--nats-watcher eaxsim=<its public key or the seed file>(EAX_NATS_WATCHERS; on an HA pair, the same key on both nodes) and eaxsim with-nats-nkey <seed file>. Use a new key: a key that is already the server’s, a PLC’s or another watcher’s, a name given twice or an unreadable seed stops eaxScada at start. Connect an eaxsim host to eaxScada’s broker - Check that no eaxPLC uses the id of one of this server’s driver devices. Values this server’s own Modbus, S7 or other driver devices publish on the UNS are no longer held for a PLC announcement. An eaxPLC (above all a simulated one) using such an id takes those paths only from its first announcement, and its values before it are not held. Give each eaxPLC an id no local driver device uses. How a PLC is told simulated
- Behind a reverse proxy, the Studio and the runtime no longer poll a route that answered
404or403./api/remote/sessions,/api/collab/reviews?live=1and/api/genealogy/statusare not asked again by the page, and after a404not by the browser tab for 10 minutes; a failing route (no answer,408,429,5xx) is asked less often, the wait doubling from 15 s up to 5 minutes. A route you open at the proxy later is used again in a new tab, after those 10 minutes, or (after a403) at the next page load. Access logs and request-rate monitoring at the proxy see far fewer of these requests. A proxy that routes only part of the API
Installable app and alarm journal at shutdown (4 November):
- Two new public paths:
/manifest.webmanifestand/sw.js(GETonly, no sign-in, no site or user data), with the static files/static/pwa/offline.htmland/static/img/pwa/*.png. A reverse proxy in front of eaxScada must pass both paths through, as it does/static/, or the app cannot be installed (the browser keeps working). Installing needs HTTPS orlocalhost: over plain HTTP the browser offers nothing and no install item is shown./sw.jsis refused through eaxCloud remote access. Install eaxScada as an app, Paths the proxy must pass - At shutdown, alarms are shown suppressed with “server shutting down” and no longer trip or return to normal. A condition that changes during the shutdown is evaluated at the next start instead. A log monitor that watched for “alarm journal event not recorded: sql: database is closed” should watch for the WARN line “alarm event not recorded: the alarm journal is closing (server shutting down)” (field
not_recorded, the count) instead; it is written only for an event raised after the engine stopped. The journal at a server shutdown
Analytics and Reports (5 November):
- After the upgrade only the Administrator can use Analytics and Reports. Eight new rights (
reports_view,reports_design,datasets_edit,reports_schedule,reports_distribute_external,reports_sign,analytics,reports_admin) are feature rules in Security > Permissions. Existing permissions are not changed: without a rule naming a right, only the Administrator holds it, and the catch-all*does not grant it. To match a new installation, givereports_viewto Shift_Operator and Process_Supervisor, andreports_view,reports_design,datasets_edit,reports_scheduleandanalyticsto Lead_Engineer; givereports_sign(withreports_view) to your own QA role when signing comes. A DENY rule on a right refuses it to the Administrator too. The AI co-pilot can never hold more thanreports_view. Grant report rights /api/reports/*and/api/analytics/*answer403 EDITIONon Free and Starter, the Administrator included: the module is Pro and Enterprise only and, unlike the other Pro data features, not part of the Free evaluation. A Pro licence on a build without the columnar historian answers503 REPORTS_UNAVAILABLE. With security off the routes answer403. API tokens are refused on every route of the module except the on-demand runs and the file download (403 REPORTS_TOKEN), and those stay closed while the token gate admits only the MCP gateway. Through eaxCloud remote access, signing, schedules, the purge and the settings change are refused./api/system/infoand/api/licencelist the new featureanalytics_reports. Grant report rights- Check the new
reports:,analytics:andsite:sections before starting an upgraded server if yourconfig.yamlsets any of them: a refused or out-of-range value now stops the start, as the audit settings do (for examplereports.run_timeoutshorter thanreports.query_timeout, a relative folder inreports.folders.allowed, or asite.time_zonethat is not a zone name). Nothing changes for a file without these keys. The report engine starts only whenreports.enabledis on, the licence in force at start-up includes Analytics and Reports, and the build has the columnar historian; otherwise the routes answer503 REPORTS_ENGINE_OFF, and a licence installed later takes effect at the next start. Reports print times insite.time_zone(empty: the server’s own zone). Configuration keys - A report figure computed from several values is good only if every one of them is good (the
agg_qualityrule): uncertain if any is uncertain and none is bad, bad otherwise, and a missing or unknown quality counts as bad. KPI tiles average the good samples only and print “No good data”, never 0, when there is none, so a report’s average can differ from a plain average of the same rows that includes bad samples. A historian dataset that returns values without their quality is refused on save. Data quality - New stored data to include in disk budgets and backups. Datasets are kept in
data/reports/datasetsas project content (in checkpoints, replicated to an HA standby, saved on the primary first); run records indata/reports/runs; the files of every run inreports.archive.dir(defaultdata/reports/archive/<yyyy>/<mm>/), written once and checked against their SHA-256 before every download (500 REPORTS_INTEGRITYwhen a file no longer matches: do not edit or move these files). A run with files is not deleted from the workspace (409). Run records, the archive and SHA-256 - Integrations that read screen documents meet a new kind,
report. A report template is a screen of kindreportwith areportmember; it is listed and deployed with the other screens and gets no runtime page. Saving or deploying a report that holds an object able to write (an input field, a button with a command, a setpoint, a script, a component that writes) is refused (400); a member the report model does not know is refused on save. Runs use the deployed copy only: a report that is only saved does not run (404). Design a report - Audit trail readers get the category
reports:dataset.create,dataset.update,dataset.delete(written before the change,_FAILEDafter a failed one),run.start(before the run),run.succeed,run.fail,run.refuse,run.cancel,run.previewandfile.download(before the file is sent). A dataset change, a run or a PDF draft whose record cannot be written is refused (503 AUDIT_NOT_WRITTEN). Audit events
Analytics and Reports: schedules, signatures, archive and delivery (5 November):
- Reports find the quality column in any case. A dataset that returns
AS Quality_Class(orQUALITY) had its quality ignored in the PDF and the workbook, so every row counted as good; it is now read, with one rule for the PDF, the workbook, the designer’s preview and the dataset grid (quality_class, elsequality; a row whose quality cannot be read counts as bad). Reports over such datasets can now show bad and uncertain marks, and their KPI figures can change. Data quality - Archived PDFs are written as PDF/A by default (
reports.archive.pdfa: true): fonts embedded, and one CSV file per dataset with the report’s rows embedded in the PDF, so files are larger. They are PDF/A-3b, validated with an independent PDF/A validator, PDF/A-3B profile (see note 136). Setreports.archive.pdfa: falseto keep plain PDFs. PDF/A with the data inside - A run that would pass the archive quota or the disk floor fails and archives nothing.
reports.archive.quota(default20GiB) and the floor, the larger ofreports.archive.min_free(default2GiB) andhistorian.disk.critical_freeon the archive’s disk, are now enforced; nothing is deleted to make room. Before upgrading, compare the size ofreports.archive.dirwith the quota and the free space with the floor; the alarm ALM-SYS-REPORTS is active from 80 % of the quota. Quota and disk floor - On-demand runs resolve their relative dates when they are asked for, no longer when they start:
yesterdayin a run queued at 23:59 that starts at 00:01 is still the day before the request. Scheduled runs resolve them at their slot. The run record has the new fieldas_of. Time zones - Users may open other users’ runs whose tags they may all read. A run record, its files, its verification and its signatures now open, besides the runner and
reports_admin, for a user who may read today every tag the runner could read in that run (a user who may read every tag opens them all). Opening one writesfile.view. Others get the same404as for a missing run. Runs with an alarms dataset, and runs recorded before this release (they hold no read scope), stay with their runner andreports_admin.GET /api/reports/runs?scope=allandGET /api/reports/archivelist them. Opening another user’s run - Report datasets include history kept only in the historian’s CSV files (an installation upgraded from a build without the columnar store, history from before a columnar store reset): reports over such periods now show rows they used to miss, so their figures can differ from earlier runs. Each tag’s CSV rows are read only before its first point in the columnar store; an encrypted historian is read as before. A partition file that cannot be read makes the run fail instead of returning a shorter report, and a long CSV-only window can pass the 15-second preview limit (the message says to shorten it). History kept only in the file store
reports.email.smtp.starttls: falsestops the server at start unlessallow_plain: trueis set, the host is this machine (localhostor a loopback address) and nousernameis set. Mail always goes with STARTTLS otherwise, and a mail server that does not offer it receives nothing. Port 465 (implicit TLS) is not supported: use the submission port with STARTTLS, usually587. Set up e-mail and folder delivery- New stored data and HA steps. Schedules are project content in
data/reports/schedules(in checkpoints and replicated); a schedule that comes from another server stays off until areports_adminturns it on here. The server writesdata/reports/server-identityat its first start and, on a single server,data/reports/schedule-state.json. On an HA cluster, set the samenats.cluster.nameon every node (it already must be), and copydata/security/reports_secrets.jsonanddata/security/reports_secrets.keyto every node after storing the SMTP password: a node with another key delivers nothing. Signed copies are archived next to the originals (<run>.signed-<n>.pdfand.json). Schedule a report - Integrations meet the new routes and answers: schedules, signatures, verify, the archive list, the purge and the SMTP password answer instead of
501;PUT /api/reports/settingsanswers501 RESTART_ONLY(everyreports.*key is read at start-up). The AI co-pilot and API tokens are refused on every schedule, signature, purge and settings route (403 REPORTS_AI,403 REPORTS_TOKEN); through eaxCloud remote access the archive list and the schedules’ status are view and every change, signature and purge is refused. A run with a signature, or waiting for one, is never removed (409). Existing run records keeptrigger.kind: on_demand. HTTP routes - Audit trail readers get new
reportsevents:schedule.create,schedule.update,schedule.delete,schedule.enable,schedule.disable,schedule.owner_change,sign.review,sign.approve,archive.verify,archive.purge(one before each deleted file),deliver.email,deliver.folder,file.viewandsettings.update; a scheduled slot that is refused writesrun.refuse. Monitoring gets the system alarm ALM-SYS-REPORTS and thereportssection of System Health. To let QA sign, grantreports_sign(withreports_view) to your QA role. Audit events
Analytics and Reports: signed copies, UTC, HA, licence changes and the analytics workspace (6 November):
- Signed copies are about the size of the report. A signed copy wrote every page of the original again for each page before it, so an 80-page daily report of 29 KB gave signed copies of 8.9 MB; each page is now copied once (an 83-page sample: 14.6 MB before, 443 KB now). The pages print exactly as before and the original is untouched. Signed copies made before stay as they are (signed records are never rewritten); a new signature on such a run writes its new copy at the normal size. Signed reports
- Times labelled UTC are shown in UTC. The signatures’ Signed (UTC), the run’s Finished (UTC), the “Signed: …” confirmation and the Archive’s Archived (UTC), Data from (UTC), Data to (UTC) and Kept until (UTC) columns were shown in the browser’s zone; they are now UTC, also in the CSV export and the column filters, and the Archive’s Archived from / until (UTC) fields take UTC days. Site time is the site time the server recorded with the signature (
site.time_zone, else the server’s zone); the server’s own zone is no longer printed as “Local”. Compare exported Archive CSVs made before and after the upgrade with this in mind. Time zones - HA clusters with Analytics and Reports start again. The HA configuration store stopped the server at start-up when the report datasets (
reports.datasets) and schedules (reports.schedules) registered, because it accepted only domain names without dots. Dotted domain names are accepted now; the keys of the existing domains are unchanged, so nothing is migrated. Report datasets and schedules now replicate to the standby and survive a restart like the other project documents. HA replication - A signed copy’s record says PDF/A:
pdfa: "3b"in the signature’srenditionwhen the copy is PDF/A-3b. Records of copies signed before keep their records. Signatures - The workspace is read-only after a downgrade, no longer hidden: when the licence does not include Analytics and Reports but the engine runs read-only, the Runs and Archive tabs are shown (no Reports, Datasets, Schedules, Analytics, Sign, Purge or Settings, no Cancel or Remove), with the chip “Read-only: the licence in force does not include Analytics and Reports; archived reports stay readable”. Every change is still refused with
403 EDITION. After a downgrade - System Health has an Analytics and Reports section: the licence (read-only or included), schedules paused by the licence, the scheduler, the archive’s use and faults, ALM-SYS-REPORTS with its reasons (also in the attention banner), and the archive replication with each standby’s last report and the files a standby refused. ALM-SYS-REPORTS
- Signed copies are now PDF/A-3b when the run’s archived PDF is. They failed the validator before (no output intent, no document metadata, no file identifier, objects copied without the line breaks PDF/A asks for); a signed copy now carries the same colour profile, metadata and file identifier as the archived PDF, in PDF 1.7, and prints exactly as before. The archived PDFs themselves were validated as written (an independent PDF/A validator, PDF/A-3B profile) and do not change. The data CSVs stay embedded in the original only. A run archived without PDF/A gives a plain signed copy. PDF/A with the data inside
- Signed copies made before this version stay plain PDF (signed records are never rewritten). Two signed copies of one signature are not byte-identical; each copy’s hash is recorded after it is written, as before, so compare hashes from the run record, not from a second rendering. Signatures
- New route
POST /api/analytics/query: an ad-hoc query runs as the person who sends it, as an unsaved dataset through the dataset path (the SQL guard, the allowed tag set, the secured relations, the bound window, the rolled-back transaction).tag_history,main.*, temporary tables, files and table functions are refused; a tag parameter outside the user’s rights is refused before the query runs; the time window (from,to) is required andtag_scopecan only narrow. Hidden tags are counted, never named. Analytics workspace - Analytics limits: at most
analytics.max_rowsrows (default 100,000; the key is now used) andreports.query_timeout(60 s) per query, results at most 64 MiB, one running query per user and two per server (429 ANALYTICS_BUSY, never queued). A result is kept as the user’s cursor (one per user, 10 minutes idle, 16 per server) and read in pages of at most 10,000 rows (GET /api/analytics/query/{id});DELETE /api/analytics/query/{id}drops it; another user’s result answers404;DELETE /api/analytics/querycancels your running query (409 ANALYTICS_CANCELLED). Analyse data - SQL errors answer
422 REPORTS_SQLwith{message, line, column}in the text sent; the workspace shows them at the editor’s line, also for “run the selection”. Analytics workspace - Analytics results carry quality, never guessed. With a quality column each row has the server’s class (
row_quality). A historian query that reads values without quality is answered withignores_quality, the save rule’s reason and fix, and the rows that may hold non-good samples (row_affected); the grid marks them and the chart draws them as non-good. Integrations reading results must honour these fields. The analytics workspace - Analytics is for people with the
analyticsright only: an API token (403 REPORTS_TOKEN) and the AI co-pilot, whatever its rights (403 REPORTS_AI; it keeps its own MCP SQL tool), are refused on every analytics route. Through eaxCloud remote access a query is an engineer action. Who may use it - Audit trail readers get the category
analytics:analytics.queryfor every query run, refused or cancelled, with the SQL text’s SHA-256 (the full text in the server log), the parameters, rows, the result hash and the duration; one record per identical query per user per minute, the repeats counted into the next. A result whose record cannot be written is not given (503 AUDIT_NOT_WRITTEN). Audit events - Saved queries are personal, stored in
data/analytics/saved_queries.jsonby user id: not project content, so not in checkpoints, project archives or HA replication; at most 200 per user; the time window is not kept. “Save as dataset” is the datasets route (datasets_edit, the save check and its quality rule). Save the query - The Analytics tab is shown with the
analyticsright only (a new installation gives it to Lead_Engineer; see note 113 for upgraded installations); on a phone it says to use a wider screen. Grant report rights - Export, extracts and the server pivot are in this release too:
/api/analytics/export,/api/reports/datasets/{id}/exportand/api/analytics/extractsno longer answer501(notes 164 to 178). Going further - Run records reach the HA standby. Every run record change (queued, finished, each signature, each delivery outcome, the purge) is replicated server state (the cluster store’s domain
reportruns, never part of a checkpoint), written on the node first and committed to the cluster after. A signature and the taking of a pending delivery are committed to the cluster first: refused there (a standby, a primary without quorum or replaced by a newer term, a copy older than the cluster’s), nothing is recorded. A record never loses a signature to an older copy, and one holding archived files or signatures is never removed by replication. HA replication - Archived files reach the HA standby: the standby pulls the primary’s archived PDFs, workbooks and run sidecars, then each signed copy and its link record, by hash, within its own
reports.archive.quotaand disk floor. Size the standby’s archive disk like the primary’s. A purge on the primary removes the purged run’s files on the standby too, with onearchive.purgerecord per file (replicated: true). High availability - After a failover the new primary lists every run, serves and verifies the files and takes the next signature. A run another node left queued or running is closed as failed (a scheduled slot is re-run once within its grace); a delivery another node had started is closed as failed and never sent again (some recipients may have received it); a fully signed run whose delivery was pending is delivered once by the new primary. High availability
- ALM-SYS-REPORTS is also active when a standby has not confirmed an archived file for more than an hour, or refused a file of the primary (another hash), and while schedules are paused by the licence. System Health shows the replication (
reports.replication: “archive replication behind by N files”, the last pass, refused files, run records not committed). ALM-SYS-REPORTS - Archived reports stay readable after a downgrade or a licence expiry (Starter, Free, an expired licence). Open, with every other check:
GET /api/reports/me,GET /api/reports/runs,GET /api/reports/runs/{id}, its files (pdf,xlsx,signed-<n>),POST /api/reports/runs/{id}/verify,GET /api/reports/runs/{id}/sign,GET /api/reports/archive. Every other route answers403 EDITION, including signing a step of an archived run: signing is part of the module. Signatures already given stay checkable, and a licence with the module lets the next step be signed again. After a downgrade - The report engine starts read-only when the licence does not include Analytics and Reports but report data exists (
data/reports/runsor the archive folder); before, it did not start and the archive was unreachable (503 REPORTS_ENGINE_OFF). The licence is checked on every change, so an expiry while the server runs takes effect at once. After a downgrade - Schedules pause with the licence: no slot claimed, run-now
refused, event and batch-end triggers skipped, ALM-SYS-REPORTS “paused by the licence” for each schedule. A licence with the module resumes them without a burst, the missed slots following each schedule’scatch_up(last_missed: the newest one;none: none;all: the newest 10). Pending deliveries wait and are delivered once the licence is back. When the licence no longer includes the module - HA upgrade step: nothing to migrate. At the first start of this version on a cluster, the existing run records are copied to the cluster store from the primary; the standby then pulls the existing archive. Watch System Health until it is no longer behind before you rely on a failover. High availability
E-signatures (6 November, safety: authentication):
- Every signature-ticket route answers a refused signature
403withstatus: "signature_refused", no longer401:POST /api/auth/signature-ticket,/api/dev/projects/{id}/deploy-esign/ticket,/api/collab/reviews/{id}/signature-ticket,/api/checkpoints/{id}/sign,/api/backup/sign,/api/reports/runs/{id}/sign/ticket,/api/reports/archive/purge/ticket. That covers a wrong password, an unknown or disabled signer, the AI co-pilot, an API token and a tag the signer may not write. A lockout stays429, a missing password or field400, a ticket the server could not hand out (open-ticket cap, HA store)503(it was401), an unrecorded signature503 AUDIT_NOT_WRITTEN.401only means “no session” (code: "no_session"onPOST /api/auth/signature-ticket). Integrations that took401for a wrong password must read403 signature_refused. A refused signature is not an ended session - A wrong password no longer signs the person out. The page signed out on any
401from a signature; now the dialog stays open with its message and an empty password field (also on a401whose answer sayssignature_refused, from an older route). The report Sign and purge dialogs send their ticket requests by the normal request path again. The lockout is unchanged: each wrong password counts, the fifth locks the account for 15 minutes (429), and the right password is refused while it lasts. Sign a report - Genealogy signatures (records that release or quarantine, corrections, voids, imports, purges; the signer’s own and a correction’s second person’s): a wrong password, an unknown or disabled signer
403 status: "signature_refused"(was401); a lockout429; a missing password400; an unknown second signer403(was401). Genealogy API - Applying an AI proposal (
POST /api/mcp/approve/proposal): a wrong password403 status: "signature_refused"(was401 signature_rejected); a lockout429 signature_refused; no password403 signature_required(was401); an unrecorded signature503 AUDIT_NOT_WRITTEN(was401). The Apply dialog in Studio > AI gateway stays open on a refused signature, says why under the password field and empties it; the proposal is unchanged. It still closes on success and on any other refusal. Review and apply proposals - The supervisor co-signature of a batch start (
POST /api/batches,supervisorandsupervisor_password): a wrong password, an unknown or disabled co-signer403(was401); a lockout429(was401); no password400. The answer stays plain text, and the Launch batch dialog stays open with the message. POST /api/auth/signature(the signature eaxPLC asks eaxScada for, with the person’s PLC token or session): a wrong password403 status: "signature_refused"(was401); an account that is not active403(was401); no password400(was401); a lockout429withstatus: "signature_refused"; the AI co-pilot and an API token403withstatus: "signature_refused".401is only “no caller” and sayscode: "no_session". The same shape applies toPOST /api/auth/signature-ticket(its400and AI co-pilot403carrystatus: "signature_refused", its401code: "no_session"). The lockout is unchanged on every route (a locked account’s session also ends, as before). A refused signature is not an ended session- eaxPLC needs no change to work with this eaxScada (it already took
403for a refused signature). eaxPLC’s own update tells a refused signature from a missing session, with an older and this eaxScada. What’s new in eaxPLC
Analytics and Reports: pickers and signature status (6 November):
- New read routes for schedulers and designers (a person only: an API token and the AI co-pilot are refused; remote access: view):
GET /api/reports/schedules/options(reports_scheduleorreports_admin: the shift calendar names, the delivery folders’ base names, never a path, a name two allowed folders share left out; whether attachments, external domains and e-mail are allowed, the domains themselves only forreports_distribute_external),GET /api/reports/recipients(reports_scheduleorreports_admin: active accounts as{id, username, full_name, has_email}, never an address or a role, never the AI co-pilot),GET /api/reports/roles(reports_design: role names for a signature plan). The schedule editor and the signature plan offer these lists to non-administrators instead of typed names. Schedule routes GET /api/reports/runsandGET /api/reports/runs/{id}carry each run’ssignature(state, plan, the step it waits for, signatures given, retention, hold) as the server decides it; the page no longer works it out itself. Run record
Analytics and Reports: export, extracts across sources and the server pivot (6 November, safety: read permissions, what leaves the plant as a file, authorization, audit):
- New export routes:
POST /api/analytics/export(analytics) andPOST /api/reports/datasets/{id}/export(reports_view) answer202with a job andLocation;GET /api/analytics/export/{id}(the job),GET /api/analytics/export/{id}/file(the file,ETag= its SHA-256,no-store) andDELETE /api/analytics/export/{id}take either right. An export reads as the person who asks, through the same secured path as a query (read rights, allowed tags, the window required,tag_scopeonly narrowing); the query is checked before the job is queued (422). The server writes the file from the secured rows;COPY,ATTACHand the file-reading functions stay refused in user SQL. Export routes - An export is its owner’s only: another user’s export id answers
404(never403), an id not of the shapeexp_<yyyymmdd>T<hhmmss>Z_<12 hex>answers400before any lookup. Integrations cannot share export ids between accounts. Who may export - Export limits refuse, never cut: over
analytics.export.max_rows(1,000,000) oranalytics.export.max_bytes(512 MiB) the job failsEXPORT_LIMIT, its partial file is deleted and the download answers413. One export per user (409 EXPORT_BUSY);analytics.export.workers(1) run on the server, the others wait; five minutes per export; a file that is not ready answers409 EXPORT_NOT_READY, one gone410. Files are deleted afteranalytics.export.keep(24 h), swept at start-up and every 10 minutes (files of an earlier run included). Limits - Export defaults lowered, and checked at start-up:
analytics.export.max_rowswas5000000, now1000000;analytics.export.max_byteswas2GiB, now512MiB, and more than4GiBstops the server at start (the result is held in memory while the file is written). A relativeanalytics.export.dirmust be insidedata/without.., else the server does not start: give an absolute folder. Checkconfig.yamlbefore the upgrade if you set these keys. Configuration keys - Analytics queries have their own keys:
analytics.query_timeout(60 s; wasreports.query_timeout),analytics.per_user(1) andanalytics.workers(2; wasreports.workers). With the defaults nothing changes; if you tunedreports.query_timeoutorreports.workersfor analytics, set the new keys (the report runs keep thereports.*keys). Configuration keys - The AI co-pilot and API tokens are refused on every export and extract route (
403 REPORTS_AI,403 REPORTS_TOKEN). Before this version the AI co-pilot’s account passed the checks of the dataset export route, andPOSTandDELETE /api/analytics/extractswere not marked person-only (all three answered501). Through eaxCloud remote access, exports and extracts (including the newGET /api/analytics/extractsandDELETE /api/analytics/extracts/{name}) are engineer actions. Who may use it - New extract routes:
POST /api/analytics/extracts(201) reads one relation (samples,alarm_events,alarm_definitions) over a window, as the user, into the user’s own in-memory session;GETlists them with the session and the limits;DELETE /api/analytics/extracts/{name}drops one,DELETE /api/analytics/extractsall. Sessions are keyed by user id: another user’s extract answers404 EXTRACT_UNKNOWN(or410 EXTRACT_EXPIREDwithout a session of their own). Extract routes - Queries and exports over extracts:
POST /api/analytics/queryand/api/analytics/exporttake"family": "extracts": oneSELECTnaming only the user’s extracts (no qualified names, no table functions), notag_scope(and for an export nowindow:400 EXTRACT_SPEC). Result ids start withax_(aq_for the other families). A query over extracts takes a place amonganalytics.workerslike any query (429 ANALYTICS_BUSY, never queued). Query across the extracts - Extract limits:
analytics.extract_rows(2,000,000, now applied) and the newanalytics.extract_bytes(512 MiB; more than 4 GiB stops the server at start) per session;analytics.extract_per_user(new, 8, 1 to 32);analytics.extract_idle(new, 30 min, 5 min to 24 h). An extract over a limit is refused whole (413 EXTRACT_LIMIT); one too many409 EXTRACT_TOO_MANY; a bad name400 EXTRACT_NAME; a bad family, relation or window400 EXTRACT_SPEC; a cancelled read409 EXTRACT_CANCELLED; the server stopping503 EXTRACT_CLOSED. Limits - Server-wide cap of extract sessions: at most
analytics.extract_sessionsusers (new, default 4, 1 to 64) hold extracts at once; a new user’s first extract beyond it answers429 EXTRACT_SERVER_FULL(never queued, recorded as a refused create), while the users who hold a session keep working. The extracts’ worst-case memory,extract_sessions × (2 × extract_bytes + 256 MiB), is 5 GiB with the defaults; a configuration above 16 GiB stops the server at start. Size it to the memory the server can spare beside the runtime. The server-wide cap of sessions - Audit trail readers get new
analyticsevents:analytics.export(every export, done or refused: format, rows, bytes, file and SQL hashes, window, parameters, scope, dataset and revision),analytics.extract.create(every extract, made or refused),analytics.extract.drop(reasonuser,idleorshutdown);analytics.queryalso records queries over extracts (family: extractsand the extract names). An export whose record cannot be written fails and its file is deleted (the download answers503 AUDIT_NOT_WRITTEN); such an extract is dropped before any query sees it. Audit events - Pivot on the server: when a result is cut at
analytics.max_rows, the page groups the whole result on the server by writing aGROUP BYquery (at most 50 pivot values) into the editor and running it through the normal query route;PIVOTitself stays refused in user SQL. Pivot a large result on the server - The Analytics tab has an Export split button (it moves into the toolbar’s More menu when short), an export status line, an Extracts (this session) panel (a drawer at 1024 px and below), the source Extracts (this session) and Pivot on the server; the Datasets grid has an Export action. Saved queries may be over extracts; Save as dataset is not offered for them. Export analytics results
- Grid chips in the singular: “1 row not known good”, “1 extract with hidden tags” (all five languages).
- New stored files: export files under
analytics.export.dir(data/analytics/exports/<user id>/by default), deleted afteranalytics.export.keep(24 h); each file is at mostanalytics.export.max_bytes, and a user may make several in a day, so leave that folder’s disk some room. Extracts are held in memory only, never written to disk. Export analytics results
Screen scripts in a sandbox, and the right screens.script (7 November, breaking; safety: a capability boundary for code that runs in the operator’s browser, and authorization; every edition):
- Every project runs its screen scripts sandboxed, new and existing: Run script actions (
run_command), screen and popup startup scripts and objects’ event scripts. A script no longer getsplayerorthis(undefined), norwindow,document(cookies),parent,location,navigator,localStorage,fetch,XMLHttpRequest,WebSocket,alert,confirmor the page’s globals (runtimePlayer,scadaPopup,eaxGuardedTagWrite…). Using one fails the script with codesandbox_refused. Before the upgrade, open the Problems panel on a test copy and rewrite every script it lists underscript-not-sandboxedandstartup-script-not-sandboxedwithsystem.*. Migrate screen scripts to the sandbox - Every
system.*call that reaches the page returns a Promise,system.nav.current()andsystem.popup.list()included (they answered at once): writeawait.system.util,system.params,system.timerandsystem.tag.subscribestay immediate. A script is now the body of anasyncfunction, soawaitworks at the top level; scripts with the oldreturn (async () => { ... })();wrapper keep working. Calls that used to answer at once - Only the documented
system.*functions are reachable (an allow-list), each call checked: plain data only (a function only forsystem.timerandsystem.tag.subscribe), sizes (16 KB per call; 10 MB for files), at most 64 waiting calls, and no<,>,"or backtick in a path, name or text value the page uses (refused, codeinvalid). Texts of dialogs, toasts, desktop notifications and log lines are shown as text: markup a script put in them is no longer drawn. Limits of a call system.nav.navigateopens only this server’s pages, for every script, legacy ones included: ajavascript:ordata:address, or another site, is not opened (logged in the browser console). Open other sites withsystem.nav.openWindowand the project’s allowed external addresses.- A script that keeps its sandbox busy for 5 seconds is stopped (code
timeout; an endless loop used to freeze the operator’s page). The screen’s sandbox is closed with every script, timer and subscription in it, including the startup script’s; the next script gets a new sandbox. Reopen the screen to run its startup script again. One sandbox per screen - A refused or stopped script is marked, not toasted: a rose dashed outline and a Script refused or Script stopped label on the object (a startup script: a chip at the top left of the screen), the reason on click, removed after a minute. New client event kinds
script_refusedandscript_timeout, written to the server log and the audit trail (SCRIPT_REFUSED,SCRIPT_TIMEOUT) and counted in the 20 events per session per minute. Client events - New right
screens.script: saving a screen, popup, display, report or component that adds or changes a script needs it; without it the save stores nothing and answers403{"status": "script_permission_required", "code": "SCREEN_SCRIPT_PERMISSION", "permission", "doc", "scripts": [{kind, where}]}, recordedSCREEN_SCRIPT_REFUSEDin the Access audit. Unchanged scripts need no right: moving, resizing, restyling, renaming and removing a script do not. Copying an object with a script, duplicating a screen with scripts and turning a command into a script do. What needs the right - Who holds
screens.script: the Administrator always; Lead_Engineer and any role of level 80 or more unless a DENY feature rulescreens.script(orfeature:screens.script,screens.*) takes it away; no role below level 80, whatever an ALLOW rule says; never the AI co-pilot, whatever its other roles. Nothing to migrate for people. Integrations that save screens with scripts must use an engineer-level account; the AI co-pilot’s MCP screen tools are refused when they add or change a script. Who holds it - Every save path is checked: the Studio, restoring a screen version, duplicate, find and replace, make translatable, AI proposals applied by a person, the MCP screen tools, starter templates and checkpoint reverts (a revert whose screens or components add or change scripts answers the same
403; a server backup restore is not checked). - New project setting “Legacy screen scripts (unsandboxed)”: off for every project. Turning it on needs an Administrator and a reason (
403 LEGACY_SCRIPTS_ADMIN,400without a reason); off needs Lead_Engineer. Journaled first asPROJECT_LEGACY_SCRIPTS_CHANGED(old and new value, reason;503 AUDIT_NOT_WRITTENand nothing changes without the record). A project save keeps it; a checkpoint revert that would turn it on needs an Administrator; never changed through eaxCloud remote access. Legacy screen scripts - New routes:
GETandPUT /api/dev/projects/{id}/legacy-scripts({"legacy_scripts": bool, "reason"}; remote access:GETengineer,PUTnever),GET /api/runtime/script-policy(any signed-in user:{"project", "legacy_scripts", "timeout_ms"}; the browser keeps it 30 s and runs scripts sandboxed when it cannot read it), andGET /static/sandbox.html, the sandbox document, served with its ownContent-Security-Policy(no network,sandbox allow-scripts). If a reverse proxy in front of eaxScada rewrites response headers, keep this document’s policy as the server sends it. HTTP API - New Problems panel warnings
script-not-sandboxedandstartup-script-not-sandboxed(warnings: the deploy gate does not block on them). Check screens before deploying - Not changed: expressions (bindings, conditions, chart option expressions, text templates) are not scripts and run as before; the Scripting workspace and eaxTags scripts run on the server as before; the server’s checks of every write are the same.
Deploy impact preview, and an acknowledgement for command changes (7 November, breaking for API clients and scripts that deploy; safety: commands to equipment, a deploy gate, audit; every edition):
-
A deploy that changes command targets, scripts or the write policy needs an acknowledgement.
POST /api/dev/projects/{id}/deploymust then carry{"ack": {"preview_hash": "<hash>", "reason": "<why>"}}, where the hash is thepreview_hashofGET /api/dev/projects/{id}/deploy-preview. Without it, or with an empty or blank reason (or one over 1000 characters), the deploy is refused409 {"status": "deploy_preview_ack_required", "preview": {...}}; nothing is deployed. This includes the first deploy of any project with buttons (every command target is “added”). A deploy whose preview has none of these changes needs nothing new. Before the upgrade, change every script, pipeline or integration that deploys to read the preview and send the acknowledgement:Terminal window # 1. what would change: ack_required, counts, the lists, and preview_hashcurl -s -H "Authorization: Bearer $TOKEN" https://scada.example/api/dev/projects/default/deploy-preview# 2. deploy, acknowledging exactly that previewcurl -s -X POST -H "Authorization: Bearer $TOKEN" -H 'Content-Type: application/json' \https://scada.example/api/dev/projects/default/deploy \-d '{"ack": {"preview_hash": "<preview_hash>", "reason": "Release 4.2 of the line 2 screens"}}'Add
signature_ticketto the body as before when the project requires an e-signature. API clients and scripts -
409 deploy_preview_stale: thepreview_hashsent is not the preview the server computes at the deploy (the project was saved after the preview was read). The answer carries the newpreview. Read the preview again and decide again. A client that read a preview with nothing to acknowledge and deploys after a save gets409 deploy_preview_ack_requiredinstead. Refusals -
The AI co-pilot’s account cannot acknowledge: its deploy of such changes is refused
403 deploy_preview_ack_refused; a person deploys it. -
The acknowledgement is checked right after the review gate and before the e-signature: a refused acknowledgement does not use the signature ticket. The order and behaviour of the other checks (plant e-stop setting, lint gate, review, e-signature) are unchanged.
-
An explicit deploy is bound to the manifest its preview compared. A change saved between the checks and the deploy refuses it (
409 deploy_preview_stale, recordedDEPLOY_FAILED; the previous deploy stays live). Before, a deploy without a review or an e-signature published whatever was saved at that moment. -
New route
GET /api/dev/projects/{id}/deploy-preview(Lead_Engineer or Administrator; operators and supervisors403), read-only:preview_hash,base,next,screens,command_targets(added,removed,changed),scripts_added,scripts_removed,write_policy_changes,ack_required,counts,lint. A reverse proxy that lists the routes it lets through must list it for the engineers who deploy, or the Deploy dialog shows that it could not read the changes and keeps Deploy disabled. Deploy preview API -
Audit trail readers: the
DEPLOYrecord now ends with the preview (deploy preview <hash> acknowledged by <user>, reason: "<reason>"; ...counts, or the counts and “no acknowledgement needed”); new recordsDEPLOY_PREVIEW_REFUSED(a deploy refused by the acknowledgement check) andDEPLOY_AUTO_PREVIEW(an automatic deploy that changes command targets, scripts or the write policy, once per preview), in the access audit and the operations audit. Audit records -
Live editing is not blocked: an automatic deploy is never asked for an acknowledgement and its gates are unchanged; it is recorded (
DEPLOY_AUTO_PREVIEW). To have every command change acknowledged by a person, turn live editing off for the project. Live editing is recorded, not blocked
The AI assistant as reviewer of a deploy (8 November; safety: AI in the deploy flow, a deploy gate, approvals, audit; Pro and Enterprise with the AI assistant enabled and set up):
- An approval needs the assistant’s findings seen. When a project review has an assistant check,
POST /api/collab/reviews/{id}/deciderefuses an approval while the check runs, and, when the completed check has findings, unless the body names the check’s digest:{..., "assistant_check_seen": "<digest>"}(fromassistant_check.digestofGET /api/collab/reviews/{id}). The refusal is409 assistant_findings_unseen, and the signature ticket is not used up. Reviews without an assistant check, and checks without findings, are approved as before. Clients that approve through the API must send the digest. Signing a decision - New policy setting
assistant_check(“Require the AI assistant’s check” in Review before deploy), off by default.PUT /api/collab/policyaccepts"assistant_check": true|false; a body without it keeps the stored value, so existing clients do not change it. Switching it on needs Lead_Engineer; off, an Administrator.GET /api/collab/policyalso answersassistant_check_storedandassistant(available, provider, location, reason). The site policy - With the required check, a deploy also needs the approving review’s check completed on exactly the manifest it publishes: a check not run, running, failed or completed on another manifest refuses the deploy
409 REVIEW_REQUIREDwith the reason, and only approvals that confirmed the findings count. The gate verdict (GET /api/collab/deploy-gate) carriesassistant_check: {state, hash, findings, counts, card, required, reason}. While the assistant is unavailable to the project, the check is not required, even when the setting is stored. The required check - Findings never block a deploy by themselves, whatever their severity (
blockingincluded): the assistant is advisory and never an approver; a decision from it is refused, and the AI co-pilot account cannot start a check (403). POST /api/collab/reviewswithassistant: truestarts the check of a project review, and answers409 assistant_unavailablewhen the assistant cannot review the project. New routePOST /api/collab/reviews/{id}/assistant-check(Lead_Engineer or Administrator;202) runs it again; it is refused once approvals were given on a completed check (request a re-review).GET /api/collab/reviews/{id}carriesassistant_checkandassistant_availability. PLC program reviews get no assistant check. The AI assistant’s check- Audit trail readers: new ledger records (category REVIEW)
ASSISTANT_REVIEW_STARTED,ASSISTANT_REVIEW_COMPLETED(byai-assistant) andASSISTANT_REVIEW_FAILED; each finding’s comment thread is aCOLLAB_THREAD_CREATEDbyai-assistant; the security audit addsAI_REVIEWandAI_REVIEW_FAILED. Audit
Historian memory cache bounded (8 November; safety: historian values operators see; every edition):
- Points already stored leave the in-memory cache once the tag has 600 newer stored points or they are more than 10 minutes old; reads take them from the store. Points no store took (logging paused by the disk guard, a refused write) stay in the cache as before, up to 50,000 per tag. What trends, exports, reports and the AI assistant’s history tools return is unchanged: recent trends still come from memory, older ranges from the store. The server’s memory now levels off under a steady load. The in-memory cache of recent points
Search reviews and comments (8 November; safety: authorization of what a search returns; Pro and Enterprise):
- New read-only route
GET /api/collab/search(project=orplc=,q,kind,from,to,author,limitup to 200) returns only the records the caller may read through the routes they come from: reviews, decisions, checks and PLC comments for any signed-in user; a comment on a screen only with that screen’s read right. Tag comments are not searched. Search reviews and comments - The AI co-pilot account is refused (
403 ai_copilot_refused): the archive holds every person’s review discussion. - New edition feature
collab_search, Pro and Enterprise, listed in the edition status. Free and Starter answer403(“Search reviews and comments requires a Pro licence or higher.”); Free still evaluates reviews themselves. A build without the columnar engine answers501 archive_not_built. - A new local file,
<data>/collab/archive.duckdb, derived from the stored reviews and comments: opened at start-up once it exists, created on the first search, and rebuilt from them when deleted; not encrypted and not in backups. When it cannot be read the search answers503 archive_unavailable; reviews, decisions, comments and deploys never wait on it and are not affected. The archive
Who else is on a screen, and the editing lock with Take over (8 November; safety: authorization; every edition):
- New routes
GETandPOST /api/studio/presence(who is on the screens the caller may read, each screen’s lock, a tab’s heartbeat) andPOST /api/studio/presence/lock,/takeoverand/release. A heartbeat on a screen the caller may not read is refused403and not recorded; lock and take-over need the edit right on the screen (Lead_Engineer or above, the screen’s write permission and its read right), refusals403journaledPERMISSION_DENIED. Studio presence API - A screen someone else is editing opens read-only in the Studio: the canvas takes no edits, the properties panel is inert, and Save and auto-save do nothing until you take over or save your changes as a copy. Saving itself is unchanged: the lock is advisory, a save is never refused for want of the lock, and the revision check (
If-Match,409 stale) stays the guard against lost updates. - A take-over is recorded in the audit trail before it is made (category
SCREEN, actionSCREEN_EDIT_TAKEOVER, old value the previous holder, new value the new one); when the record cannot be written it is refused503 AUDIT_NOT_WRITTENand the lock stays. It needsconfirm: true(400 confirm_requiredotherwise) and never touches the stored screen or its revision. - The AI co-pilot account and API tokens take no part: every presence route answers them
403 ai_copilot_refused; they never appear and never hold a lock, and their saves go through the revision check as before. - In memory on one server, not replicated. After a restart or an HA failover presence rebuilds from the next heartbeats (within 15 s). An HA standby, or a primary without quorum, refuses the lock and the take-over like other Studio changes. Through eaxCloud, reading presence is a view route; heartbeats, locks and take-overs are engineer routes, so a remote viewer does not appear. The WebSocket signal
STUDIO_PRESENCE_CHANGEDcarries no content.
Every tag on the UNS once, and the telemetry replay buffer (9 November; every edition):
- Every tag change is published once on
uns.telemetry.<path>(path separators as dots), with the same payload as a driver’s values. eaxTags and internal tags (System Health and others no driver reads) moved there fromscada.v1..., withdevice_idandaddressempty; an MQTT channel’s values are there too. Normalised telemetry subjects scada.v1.corp.paris.processing.areaA.cell1.tag.<path>.valis no longer published, noralarm.v1.corp.paris.processing.areaA.cell1.alarm.<id>.event: the fixed placeholder names never described the plant. A client that subscribed toscada.v1.>subscribes touns.telemetry.>; one that subscribed to the alarm subject, touns.alarm.>(alarm transitions onuns.alarm.<alarm id>.event, the alarm event as JSON).- A NATS channel reading another broker has its values republished on this server’s broker as
uns.telemetry.<path>, once, with this server’s origin mark so that no bridge takes them in again. A channel reading this server’s own broker is not republished. A channel disabled while running publishes each of its tags once with the out-of-service quality. - The JetStream stream
TELEMETRYholds at most 64 MB by default (10 minutes at most, the oldest messages first; it held 256 MB and alsoscada.>). The new keynats.telemetry_buffer(at least1MB) sets it; an invalid value is logged and the default kept. An existing stream is updated at start. A client replaying from the buffer gets fewer minutes back at a high change rate. Server configuration
Historian reads: memory, speed and CSV history (9 November; safety: historian values operators see; every edition):
- With the columnar engine, points the store took are no longer kept in memory: trends, exports, reports and the AI history tools read them from the store. Only points no store took stay in the cache (up to 50,000 per tag), with any stored point of the same tag and timestamp, so the later write still wins. Builds without the embedded database keep the 600-point / 10-minute window. What a read returns is unchanged. The in-memory cache of recent points
- Trend and history reads no longer wait for the historian’s writes, and a read of the CSV partitions no longer waits for a CSV write in progress. Results are the same.
- When a columnar query fails with encryption at rest (no CSV copy), the fallback returns only the points no store took; it used to return the newest 10 minutes or 600 points per tag too. Without encryption the fallback reads the CSV copy, as before. Superseded in this release by items 233 and 238: no CSV copy is written, and a failed columnar read is “History unavailable” (
503). - CSV and JSON exports with encryption at rest include every day, the columnar store’s days and tags included; an error reading them fails the export instead of exporting less.
- CSV history is read with DuckDB’s CSV reader, all the tags of a request in one query, with the same points as the built-in reader (one per tag and timestamp, the later write,
late.csvoverdata.csv). On any doubt (a file being written, a malformed row, two different rows of one timestamp in one file, a reader error) the built-in reader answers for that tag. The built-in reader names the window’s days instead of listing every day folder. How trends read CSV history - Tags whose CSV cell is quoted read back (a path with a comma, double quotes such as OPC UA
"DB1"."Speed", or a leading space): they had no history before. - Only
data.csvandlate.csvare read in a tag’s day folder; other*.csvfiles there are ignored. - New server flag
--diag-pprof-addr(support tool, off by default): heap and CPU profiles and memory statistics on a listener of its own, loopback addresses only (127.0.0.1:<port>,[::1]:<port>,localhost:<port>); any other address is refused and logged, and the server starts without it. Reach it from another machine through an SSH tunnel only. Command-line flags
Historian copies, restores and unavailable history (9 November; safety: historian data and values operators see):
- The daily Parquet export comes on in Pro and Enterprise, with the columnar store and without encryption at rest, when the config file does not set
historian.export.enabled. Withoutkeep_daysit keeps the historian’s retention. The old generated section (enabled: false,schedule: "02:00",dir: "./data/historian_export",format: parquet,keep_days: 0,compress: true), left exactly as written, reads as unset: the export comes on, and the server logs “daily history export now on by default”. Scheduled export of closed days - The first export run takes time and disk: it exports every closed day still in the history, once: about 18 s per day of history at 1,000 tags/s on the reference workstation (about 30 minutes for 90 days, about 2 hours for a year), and about 10 bytes per stored point in
./data/historian_export. It resumes after a restart, and a day the disk cannot take is skipped with ALM-SYS-HISTORIAN-EXPORT. - To keep the export off, write
historian.exportwithenabled: falseand no other line (or change any value of the old section): an unchanged old section turns it on. Keep the export off - A nightly snapshot of the columnar store is made in every edition, also when the config file has no
historian.snapshotsection: at 01:30, to./data/backup/historian, 2 kept, each about the size of the store, on the same disk by default. Leave room for up to three copies there, or sethistorian.snapshot.dirto another disk;enabled: falseturns it off. New system alarm ALM-SYS-HISTORIAN-BACKUP (medium) and audit eventsHISTORIAN_SNAPSHOT,HISTORIAN_SNAPSHOT_SKIPPED,HISTORIAN_SNAPSHOT_FAILED. The nightly snapshot - New offline restores (server stopped; without
--confirma dry run):eaxscada historian-restore --snapshot <file> [--confirm]replaces the whole columnar store (auditHISTORIAN_SNAPSHOT_RESTORED);eaxscada historian-restore --from-export <dir> [--from <day>] [--to <day>] [--confirm]adds only the points the store lacks (auditHISTORIAN_EXPORT_IMPORTED). Both keep the previous historian folder. Second copies of the history, and restoring them - An unavailable history is an error, not a shorter answer where no complete copy can answer (with encryption at rest):
/api/historyanswers503{"status": "history_unavailable"},scada_query_tag_historyreturns an error,/api/historian/exportand the scheduled CSV export fail the day,eaxscada historian-backupfails. A client of/api/historymust handle the503. No CSV copy is written any more (item 237), so this holds with and without encryption. When the history store does not answer - Trends show “History unavailable” with Retry and retry every 30 s, keeping the live samples; the History page draws nothing and says so; the Studio’s values table shows no rows.
- A tag’s CSV history ends where the columnar store began receiving that tag, not at the store’s earliest timestamp: after a backfill into the CSV era, trends,
/api/history, the AI history tool, exports, report datasets and the offline backup show the CSV history up to the store’s start. Where a tag’s CSV history ends - Two tag paths sharing one CSV folder are both exported and backed up, and the folder is kept until the longest retention, never deleted by one path’s shorter retention. The storage inventory reads CSV folders only for tags with a shorter per-tag retention; purge records count tags by folder name. Two tag paths in one CSV folder
Historian: one store, the spool, the snapshot margin (10 November; safety: historian data and values operators see):
- No more CSV in any edition of the release build, Free included (the rule is per build, not per licence). The historian writes no CSV partitions in its folder any more; the columnar store is the single store. Scripts or tools that read
data/historian/year=*/…/data.csvfor new history must move to the scheduled export (historian.export, one Hive-partitioned Parquet file per closed day, Pro and Enterprise). CSV history written before the upgrade stays and is still read. Builds without the embedded database (no columnar store) keep writing CSV partitions, unchanged. The Hive-partitioned CSV files - A failed history read is always “History unavailable” (
503{"status": "history_unavailable"}), never a partial series: there is no CSV copy to answer it. A restore (historian-restore) writes the columnar store only. When the history store does not answer - Points the store does not take wait in the spool, on disk under
<historian folder>/spool/, in order, instead of being counted lost; they are written when the store takes writes again (retried every minute), also after a restart. A store that does not open at start (without encryption at rest) no longer leaves the server running on CSV for the whole run: it keeps points in the spool and opens the store as soon as it can. New keyhistorian.spool.max_size(default 2 GB): when the spool is full, new points are counted lost (ALM-SYS-HISTORIAN-LOST). Leave room for it on the historian’s disk. When the store does not take writes: the spool - New system alarm ALM-SYS-HISTORIAN-STORE-DOWN (high, condition
HistorianStoreDown): active while the store does not take writes, clears when it takes them again. System Health’s Logging row says “store not taking writes - points kept in the spool”, and a Spool row shows the points waiting, the size of the maximum, the quarantine count and the error. - A point the store refuses for good while it takes other writes is kept in a quarantine file in the spool folder and counted lost once; a damaged spool record is cut, kept aside and its points counted lost. Under encryption at rest the spool is encrypted too.
- The nightly snapshot and the daily export skip on low disk only when free space is under what they need plus the disk guard’s critical line (
historian.disk.critical_free), no longer the warning line (warn_free). The skip says “…plus the disk guard’s critical margin of X”. The description of ALM-SYS-HISTORIAN-BACKUP says so. The nightly snapshot
Historian: the CSV history import, log levels, the spool cause (10 November; safety: deletion of operator-visible history after verification, and historian values operators see):
- New offline command
eaxscada historian-migrate-csv [--yes] [--reason <text>](server stopped): imports the CSV partitions into the columnar store, newest day first, verifies each day in the store, then deletes that day’s CSV files by exact path, each only if unchanged. Without--yesa dry run. With--yesit writesHISTORIAN_MIGRATION_STARTto the audit trail first and refuses if the trail cannot be written; thenHISTORIAN_MIGRATION_DONEorHISTORIAN_MIGRATION_HELD(HISTORIAN_MIGRATION_RESUMEDon a resume). Deleted CSV files cannot be restored by eaxScada: take a historian backup first. Where the store already has a value, it keeps it and the CSV value is recorded as a conflict. An approved import cut short resumes at the next run with--yes, or in the background when the server starts (a paused one stays paused). It refuses to start, or pauses, when the disk lacks the room it needs plushistorian.disk.critical_free. Import the CSV history into the store - Points the store refused in earlier releases appear after the import. The old CSV copy held them and trends did not show them; the import brings them into the store as “recovered” points, so trends, reports and exports show them from then on.
- A torn last line is not imported. A last line cut short in a CSV file was never shown by the built-in reader, but the trends’ faster CSV reader could show it when it could still parse it. Such a point can disappear from a trend after the import.
- Days kept for attention stay CSV. A day that fails a check keeps its files and stays readable by the CSV rule, and so do the older days of the same tag (“a newer day of the same tag folder … is kept for attention”), and the older days under a folder written in the last 2 minutes. The command then exits with code 1 and lists every kept day with the reason.
- Historian storage events log at their own level. Successes (a snapshot written, a day exported, logging resumed) at INFO, a failed snapshot at ERROR (with a failed export and logging paused, as before), the rest at WARN. They were all WARN or ERROR: a log filter or alert on WARN no longer sees the nightly snapshot written, and an alert on ERROR now sees a failed snapshot. In the server log
- System Health’s Spool row shows a short store error: the cause with the store file’s name, without its folder path or the database driver’s prefix. The full error stays in the server log and in
GET /api/historian/storage(spool.last_error); the short one is the new memberspool.last_error_short.
Historian: the CSV history import from System Health (10 November, eaxScada 61868ec; safety: deletion of operator-visible history after verification, authorization):
- The CSV history import is available from System Health, for administrators only: Historian storage > CSV history (before the columnar store) > Review import…. It is signed with an e-signature (the signed-in administrator, shown read-only, a reason and the password, neither filled in; decision
historian_migrate) over the plan as shown: a plan that changed since is refused (409), and you sign again.HISTORIAN_MIGRATION_STARTis written with the signature before anything starts; if it cannot be written, nothing starts (503AUDIT_NOT_WRITTEN). An API token, the AI co-pilot and an eaxCloud remote session cannot run it. From System Health - Pause and Resume from the dialog are recorded (
HISTORIAN_MIGRATION_PAUSED,HISTORIAN_MIGRATION_RESUMED) and need no new signature. Closing the dialog does not stop the import. - “Retry kept days…” plans the kept days again (signed,
HISTORIAN_MIGRATION_RETRY): the days kept for attention and the older days kept with them are imported again from the start, with the same checks. A file repaired since the approval is read with its new size and modification time, a folder now gone is marked gone, and a folder left out because it was being written becomes a day to import once it is no longer written. A folder written in the last 2 minutes stays out, and the older days of its tag stay kept with their reason: retry later. Before, a kept day stayed kept until a new run of the command. - The retry’s audit record lists the files: each retried day folder with its files (name, size, modification time), written before anything changes. If it cannot be written, nothing changes (
503). A retry without the disk the retried days need is refused (409low_disk). - One import at a time: a start or a retry while another start, retry or run is in progress is refused (
409busy). A signed start or retry that did not start is recorded asHISTORIAN_MIGRATION_REFUSED. - Not on phones: the studio does not show System Health on a phone, so the import dialog is on tablets and larger screens. Use the command line
eaxscada historian-migrate-csvthere. - New routes, never over remote access:
GET /api/historian/migrationandPOST /api/historian/migration/sign,/start,/retry,/pause,/resume. Historian CSV import API
Historian: CSV history import follow-ups (10 November, eaxScada a55d6af; safety: historian values operators see):
- A retry the server refuses answers
409with its code instead of500 failed:retry_later(every kept day is still kept: a folder of its tag was written in the last 2 minutes),not_approved(no import approved),nothing_kept(no day kept for attention). API status change: the signing step (POST /api/historian/migration/sign, purposeretry) answerednothing_to_retry; it answersnothing_keptnow. An integration that reads that status must read the new one. Refusals - A run started from the studio records its end, as the command line does:
HISTORIAN_MIGRATION_DONE, orHISTORIAN_MIGRATION_HELDwhen days are kept, once per run end, with the day folders imported and deleted, the rows imported, the points recovered, the conflicts kept and the days kept. A paused run, or one stopped by a shutdown, has not ended: its resume (after a restart too) writes the record. - A shutdown during the import finishes the day in progress, then the import stops and resumes at the next start. Before, a shutdown in the middle of a day rolled it back and kept it for attention (“commit: … rolled back”), with the older days of its tag, until an administrator retried them.
- The retry dialog’s note says what a retry does: “The kept days are planned again as they are now: a repaired file is read fresh and imported with the same checks. A folder written in the last 2 minutes waits, and the older days of its tag stay kept (retry later).” It said that a changed day stayed kept and needed a new approval, which was no longer the case.
- The plan grid’s “Points (est.)” has thousands separators, as the summary does, and the import dialog opens at its top (the summary and the rules), not scrolled down to the reason field.
Historian: set a broken store file aside (10 November, eaxScada f6011fa; safety: what operators see of the history, authorization):
- New: System Health > Historian storage > Store file > “Set the store aside…”, for administrators, offered only while the store file did not open at start (and has not since). Nothing is automatic: as before, the server keeps the points in the spool and tries the store every minute, the file untouched. Not offered for a store that opened and later failed writes, nor for an encrypted store (it stops the server, as before). When the historian store file does not open
- Locked is not damaged. The file is checked before anything is offered (Windows: open without sharing; Linux: a lock, with the PID). A file in use by another process (
409 locked), one eaxScada may not read (unreadable), one that opens when checked (opens_now, taken back at once) or a missing one (missing) is refused, with the cause named. - What the set-aside does: e-signed by the signed-in administrator (decision
historian_store_set_aside) over the file, its size, time and open error (a file that changed since:409 changed);HISTORIAN_STORE_SET_ASIDEis written before the file is renamed (503 AUDIT_NOT_WRITTEN: nothing changes); the file becomesscada_history.broken-<UTC time>.duckdb, its.walwith it, never deleted or overwritten; a new empty store opens and the spool drains into it. Refused during a CSV history import call or a snapshot (busy) and with less free disk than about twice the spool plus 256 MB above the critical line (low_disk). A refusal after the signature isHISTORIAN_STORE_SET_ASIDE_REFUSED. - After a set-aside, trends show the new store’s points only until the restore. System Health shows “Store set aside” with How to restore…: the newest snapshot made before the set-aside, the command and the documentation. The record
scada_history.set-aside.jsonin the historian folder stays until a snapshot restore. - The snapshots made before a set-aside are kept: while the record is there, the nightly snapshot never prunes them and they do not count towards
historian.snapshot.keep. - New flag
eaxscada historian-restore --snapshot <file> --keep-current(server stopped; without--confirma dry run): the snapshot’s history takes the store’s place and the current store’s rows are appended after it in write order (later writes win), checked by count and checksum before the swap. History written between the snapshot and the set-aside is in neither file (only in the broken one); the dry run says so. Without--keep-currentthe dry run now says how many rows of the current store the restore would drop. Every snapshot restore removes the set-aside record. Unencrypted stores only. Restore from a snapshot - The CSV history import after a set-aside shows “not started” (its state was in the broken store); a new plan lists the CSV still on disk. Days already imported and deleted are in the broken file and the snapshot: the restore brings them back.
- New routes, never over remote access:
GET /api/historian/store,POST /api/historian/store/signand/set-aside;GET /api/historian/storagegainsstatus.spool.set_aside_offeredandstatus.spool.set_aside. Historian store API
Historian: set-aside follow-ups and the nightly snapshot (10 November, eaxScada 23c5c8f; safety: historian data and what operators see of the history):
- The nightly snapshot runs once a day, no longer after every restart. At start the last run is taken from the newest snapshot in the folder (its record, else the time in its name), so a restart after today’s snapshot takes none; a snapshot missed while the server was off is still taken at the next check. Before, every start after the scheduled time took a new snapshot about a minute later, and with
keep: 2a few restarts in one day pruned the snapshots of the days before, leaving only that day to restore from. Check./data/backup/historianafter the upgrade: it keeps one snapshot per day again from now on. The nightly snapshot - After a store set-aside, the scheduled export and the nightly snapshot run again on the new store at the next minute’s check. Their last errors, recorded while the store did not open (“historian inventory: … Corrupt database file …”), are cleared. Before, System Health showed “Scheduled export: failing” until the next hourly retry.
- System Health’s “Export error” row shows the short cause: the store file’s name, without its folder or the database driver’s prefix, as the Spool row. The full error stays in the server log and in the export status (
last_error); the short one is the new memberlast_error_short. - The restore dialog names what it picks: “The newest snapshot made before the set-aside is …” (it said “The latest snapshot is …”, although it already chose the newest one made before the set-aside), or “No snapshot of this historian made before the set-aside was found: restore one from your backups.” The diagnosis banners of the set-aside dialog start with a capital letter. When the historian store file does not open
The audit trail in its own database, in Starter, Pro and Enterprise (11 November, eaxScada 089e75e; safety: audit trail, authorization, commands to equipment):
- The audit trail starts fresh. It is now the DuckDB database
audit.duckdbin the audit folder (security.audit_data_dir, default./data/audit), separate from the historian. The first start of this release in a paid edition creates it with a new genesis record. The records of an earlieraudit_ledger.jsonlare not imported, and that file is not read, changed or deleted (nor its.v1-*.bak,.torn-*and.unreadable-*side files). Installs of earlier builds were test installs: they start a fresh trail. Keep or archive the old file yourself. When it is in the folder, the recordAUDIT_TRAIL_STARTEDafter the genesis says so. Notes 61 and 62 no longer apply. Upgrading: the trail starts fresh - One record, one committed database transaction, written before the action goes ahead: each record is on disk before the action is done. Records that arrive together commit, or fail, together. Nothing else is written: no JSON copy, no CSV, no spool. A commit that fails refuses the action (
503 AUDIT_NOT_WRITTEN) and puts the trail down (note 278). - The Free edition has no audit trail. Actions that recorded first go ahead without a record; their reason, e-signature and two-person checks still apply. Nothing is created in the audit folder. Security > Operations audit,
GET /api/auditandGET /api/audit/verifyanswer403with"code": "NO_AUDIT_TRAIL"(“The audit trail requires a Starter licence or higher; this server has no audit trail.”): integrations that read the trail from a Free server must handle it (the Studio view shows it as a note, note 296). A Free server with a trail from a paid period reads it, read-only (view, Verify, backups). A build without DuckDB has no audit trail in any edition. Which editions record - The Free edition refuses the AI co-pilot’s actions on equipment and the genealogy purge (
403 NO_AUDIT_TRAIL; the MCP tools return the refusal as their error): staging and approving a setpoint, PLC program deploy, I/O force, PLC control (start, stop, mode), rollback, andPOSTof a genealogy purge, before anything is staged, sent or deleted. Before, Free ran them with a record. - The sign-in trail stays in every edition, Free included: the Access audit (sign-ins, refused sign-ins, lockouts, accounts, roles, tokens, signatures) and the features that write there (eaxTags, PLC safety targets, security administration, signature tickets).
- A trail that does not open no longer stops the server, and is never renamed aside automatically. In a paid edition, when
audit.duckdbdoes not open or take writes, the server starts or keeps running with the trail down: the new critical system alarm ALM-SYS-AUDIT-DOWN is active, every action that must be recorded first is refused with503 AUDIT_NOT_WRITTEN, and monitoring, alarms and trends keep running. The trail is tried again every 30 seconds (at an action at most every 5 seconds); when it opens it continues withAUDIT_TRAIL_RESUMEDand the alarm clears. Before, the server did not start (audit ledger failed to start), and an unreadable file was renamed and replaced by a new chain. When the audit trail is down - System requirements of the audit folder, checked when the trail opens (paid editions). Refused, with the trail down as in note 278 and checked again every 30 seconds: a network share, a RAM disk, less than 10 GB free. Warned, logged and recorded as
AUDIT_STORAGE_WARNING: removable media, SD cards and eMMC, less than 20 GB free, and a synced write faster than 50 µs at the median or slower than 50 ms at the 99th percentile. Check the audit folder’s volume before you upgrade a paid server: with less than 10 GB free it runs with the trail down. Movingsecurity.audit_data_dirtakes a restart. Audit trail system requirements - An audit folder that is the historian’s folder, inside it or around it stops the start (“security.audit_data_dir (…) is the historian folder, inside it or around it (…): the audit trail must be its own database file outside it”). Give the audit trail its own folder. Since e9926e8 in a paid edition only (note 292).
- New offline command
eaxscada audit-set-aside [--confirm --user <administrator> --reason <why>](server stopped; without--confirma dry run; the password is read from standard input and checked as an e-signature,ESIG_VERIFIEDin the sign-in trail). It refuses a trail that opens, one held by another process, one whose error names the encryption key, a Free licence, and a signer who is not an administrator or is the AI co-pilot. Otherwiseaudit.duckdband its.walbecomeaudit.broken-<UTC time>.duckdb(and.wal), never deleted, and a new trail starts: its genesis, thenLEDGER_FILE_SET_ASIDEwith the old file’s name, size and SHA-256, who and why. Set a damaged trail aside - The audit trail is encrypted with the historian’s key when
historian.tde_encryptionis on: at start, in the offline commands, in the backup’s copy and in a restore. Switching encryption on or off for an install that already has anaudit.duckdbis not supported yet: the file does not open with the other setting and the trail is down (503);audit-set-asiderefuses it. Turn the setting back. Encryption - Licence changes while running. A licence with the audit trail installed while the server runs Free starts the trail at once (
AUDIT_TRAIL_STARTED; over a trail kept from a paid period,AUDIT_TRAIL_RESUMED, note 295); if it does not open, it is down, never absent. A licence removed or expired while running keeps the trail recording until the next start. - Server backups carry a verified copy of
audit.duckdb(entryaudit/audit.duckdb, made with new records held for the copy, checked for its chain, record count and last record).backup.jsongainsaudit_trailandaudit_last_hashbesideaudit_ledger_records. A copy that fails fails the backup (BACKUP_FAILED). A Free server’s backup has an empty entry (audit_trail: “none: not in this edition”). - Restore puts the trail back verified, and refuses older backups.
eaxscada restorestages the copy, checks its SHA-256, chain, record count and last record, and only then replacesaudit.duckdb(the previous one is inrestore-before-<time>; a copy that does not check out leaves the trail in place). It resets the tip anchor and recordsAUDIT_TRAIL_RESTOREDin the restored trail. A server backup made by an earlier release (audit/audit_ledger.json) is refused, as a whole, with the reason. Make a new server backup right after the upgrade. Restore a server backup GET /api/auditpages and filters:before(the cursor from theX-Audit-Next-Beforeheader of the previous page),user,resource(exact, or a prefix ending in*),origin,fromandto(RFC 3339 or Unix ms), besideslimit(0: every record),categoryandaction. The answer is the same array, newest first. A bad value answers400(before, alimitthat did not read as a number returned every record). A reader limited by tag read rights is served page by page. Audit trail API- Tip anchor. The trail’s last record (place and hash) is also kept in the security store. A trail whose last records were cut off, or that was replaced by an older file, is found at the next start:
LEDGER_TIP_MISMATCHis recorded (the start continues) and Verify reports reasontip_anchoruntil the next start. - Verify reports
missing_record(a place of the trail is empty: a record was removed) and checks that each record’s stored context is the one its hash covers (record_hash). A commit that reported an error but reached the disk is recorded asLEDGER_COMMIT_UNCONFIRMEDwhen the trail opens again (its action was refused). Audit trail API security.audit_memory_recordsandsecurity.audit_memory_bytesno longer apply: accepted, ignored, with a warning at start. A negative or unreadable value is still refused. Remove them fromconfig.yaml. Note 100 no longer applies.- The offline commands (
historian-migrate-csv,historian-restore,restore,--reset-admin-password) record intoaudit.duckdbin a paid edition (the licence is checked as the server would) and write nothing there in the Free edition. While another process holds the trail, the historian commands refuse to go on; the password recovery says the record was not written (the sign-in trail has its entry). In a paid edition the password recovery creates the trail when the server never made it. Recover the administrator account - Monitoring: the new condition
AuditTrailDownineaxscada_system_conditionfollows ALM-SYS-AUDIT-DOWN. Alert on it: while it is 1, operators’ commands with a reason or signature, saves and deploys are refused. Metrics
The audit trail: the Free edition’s start, the trail’s state on screen, a disk alarm (11 November, eaxScada e9926e8; safety: audit trail, authorization):
- The audit folder check stops only a paid edition’s start. An audit folder inside or around the historian’s still stops Starter, Pro and Enterprise (note 280). The Free edition now starts with such a folder: it records nothing, and a trail kept there from a paid period is not opened (a warning in the log; the server runs as if it had no trail). A Free server without a trail no longer checks the folder. Before, the Free edition did not start either.
- A licence installed while the server runs with such a folder puts the trail down (
ALM-SYS-AUDIT-DOWN, actions that record first refused with503 AUDIT_NOT_WRITTEN), never recording there. Setsecurity.audit_data_dirto a folder outside the historian’s and restart: the 30-second recheck does not fix a setting. When the audit trail is down AUDIT_TRAIL_STARTEDfollows every new trail’s genesis: “The audit trail starts here (eaxScada <version>).”, or, for a trail started by a licence installed while the server runs, “A licence that includes the audit trail was installed while the server ran: the audit trail records from here on.” Before, it was written only when an earlieraudit_ledger.jsonlwas in the folder (it still names that file then) and on a licence install. A trail made byeaxscada audit-set-asidekeepsLEDGER_FILE_SET_ASIDEafter its genesis instead. Reports that expect the genesis to be followed by the first user action must skip it.- A licence installed over a trail kept from a paid period continues it with
AUDIT_TRAIL_RESUMED, notAUDIT_TRAIL_STARTED: “… The audit trail records again: no records were kept from <its last record> to <now> (Free edition).” It is written once. The chain continues (one trail, Verify valid). Note 283 now says so. Which editions record - Security > Operations audit shows the trail’s state above the grid. Free: “The audit trail is part of Starter, Pro and Enterprise; this server records nothing.”, an empty grid with that text, and no chain chip or Verify (before: “The operations audit could not be read (HTTP 403: …)”). Free with a trail from a paid period: an amber read-only note; Verify stays. Down: a rose note pointing to System Health. Keep accounts and audit trails in order
- System Health has an “Audit trail” card: the mode (recording, down with the cause, read-only, none), the file, its size and records, the last append, the append time p50 / p99 over the last 1,000 appends (amber above 50 ms), whether it is encrypted, and the system requirement warnings. A trail that is down, a requirement warning while it records, and
ALM-SYS-AUDIT-DISKadd a line to the banner. Audit trail card - The licence dialog says what the audit trail does, below the licence: “Audit trail: recording”, “down (cause)” (rose), “read-only (…)” (amber), “none (Free). Starter, Pro and Enterprise record changes and commands.” or “none (this build has no audit trail)”. Activate a licence
- APIs:
GET /api/system/healthgainsaudit_trail(mode,reason,file,size_bytes,records,last_append,append_p50_ms,append_p99_ms,append_samples,encrypted,warnings);GET /api/system/infogainsaudit_trail.mode(andwhy:freeorbuild, for none; never the reason);GET /api/licencegainsaudit_trailwith the reason when down;GET /api/auditandGET /api/audit/verifycarry the headerX-Audit-Trail-Mode(recording,down,read_only,none). The trail’s state - New system alarm
ALM-SYS-AUDIT-DISK(“Audit trail disk low - under 10 GB free”, medium; conditionAuditTrailDiskLowineaxscada_system_condition): active while the trail records, or must record, and the audit folder’s volume has less than 10 GB free. The trail keeps recording until the disk refuses a write (thenALM-SYS-AUDIT-DOWN). Clears at 10 GB free. Never in the Free edition. Alert on it besideAuditTrailDown. System alarm ALM-SYS-AUDIT-DISK
The audit trail down: the grid’s text and the log’s fix (11 November, eaxScada 8ff62f5; safety: audit trail):
- While the trail is down, Security > Operations audit no longer shows the server’s error. Under the rose note, the empty grid says “The audit trail is down; System Health has the reason.” (before: “The operations audit could not be read (HTTP 500: …)”, with the server’s message naming the database file and its folder). Other failures still show the HTTP status and the reason. The log line
AUDIT TRAIL DOWNafter a licence install now gives the right fix for an audit folder inside or around the historian’s: “set security.audit_data_dir outside the historian folder and restart eaxScada” (before: “the trail opens by itself within 30 seconds”, which it does not for this cause; note 293). Other causes keep the 30-second line. When the audit trail is down
HA records of a single server, genealogy replication, the NATS server 2.15.3 (12 November, eaxScada b6416d1; safety: audit trail, HA). When a node takes its lease, accepts control or demotes is unchanged:
- A server without an HA cluster no longer records
HA_PROMOTEDat every start orHA_DEMOTEDat every clean stop. It still takes its own lease at start and releases it at stop, but writes nothing to the audit trail for it. The log says “Node <id> took its lease (no HA cluster, term N): accepts control” at start and “Node <id> released its lease (no HA cluster; <reason>): accepts no control” at stop (before: “Node <id> PROMOTED to PRIMARY (Term N, …)” and “Node <id> demoted to STANDBY (…)”, each with an audit record). A single server that loses its lease while running still recordsHA_DEMOTEDwith the cause, andHA_PROMOTEDwhen it takes the lease back. Reports or alerts that counted these records on a single server see none at a restart now. HA panel - HA clusters record as before: every promotion once, the cluster’s first included (cause
new_cluster), and every demotion. HA panel - System Health’s HA panel on a single server shows this node holding its own lease, its term, and as last takeover the lease taken by this node (source “this node”); it reads no
HA_PROMOTEDrecord for it (before: the takeover came from the record written at the start). HA panel - The NATS server built into eaxScada is 2.15.3 (before: 2.14.5; eaxPLC’s NATS client is 1.55.0, before 1.53.1). The message store (
data\nats) is opened as it is, with no conversion, and going back to the previous eaxScada release on the same folder works with nothing lost (tested on a copy of a real single-server store). Before you upgrade, copydata\natswhile eaxScada is stopped. Embedded NATS server and JetStream - HA clusters: upgrade the nodes as Upgrading a high-availability pair says, and do not add, remove or move nodes while you do. Copy each node’s
data\natswhile it is stopped. - Genealogy replication: the “refused” count in the replication stats rises only after the refusal is recorded and alarmed (
GENEALOGY_REPLICA_REFUSEDin the audit trail, ALM-SYS-GENEALOGY-REPLICA-REFUSED raised). Before, under load, the count could briefly include a refusal not yet recorded or alarmed. High availability
The embedded database DuckDB 1.5.6 (12 November, eaxScada b75db21; safety: historian data, audit trail, the query guard). What the stores hold, how they write and when a record is acknowledged are unchanged:
- Before you upgrade, stop eaxScada and copy every
*.duckdband*.duckdb.walfile of the data folder (historian, audit trail, security, alarms, recipes, genealogy, log console, collaboration archive). Keep the copy until the new release has run for a while. Upgrading - The package ships DuckDB 1.5.6 (
duckdb.dllnext to the server; before: 1.5.5) and the historian’s encryption extension for it inbin\historian_ext\v1.5.6\windows_amd64\(Linux:historian_ext/v1.5.6/linux_amd64/). Thev1.5.5folder is no longer used. Ifhistorian.extension_dirorEAX_HISTORIAN_EXT_DIRpoints at your own bundle, put the 1.5.6 bundle there before you upgrade: otherwise the encrypted historian, and on an install with encryption at rest the audit trail and genealogy, refuse to start, with the expected path in the log. The extension is never downloaded at run time. Encryption at rest on offline and air-gapped installs - Every new DuckDB file is written in the 1.x storage format: new stores (historian, audit trail, security, alarms, recipes, genealogy and its state file, log console, collaboration archive), the nightly historian snapshot, the audit trail’s backup copy and eaxCollab’s archive. DuckDB 1.5.5 opens all of them, so going back to the previous package on the same work folder works. Before, new files took the engine’s default format; a later engine version could have written files the 1.5 builds do not open. The nightly snapshot
- Existing files are never converted. The format applies only to a file the server creates; a store that exists keeps its own format, encrypted or not. Nothing is migrated at the upgrade. The historian
- The query guard refuses a query whose parsed form lacks the names it checks (AI co-pilot SQL, the log console, report datasets, analytics extracts): a function or table without its name, schema or catalog, or with an empty name, is refused instead of passed. DuckDB 1.5.6 always gives these names, so no query that ran before is refused now. No write path
- Queries that change data inside a
WITHclause stay refused (WITH d AS (DELETE ... RETURNING *) SELECT ...): the guard refuses them itself, whatever the engine’s parser accepts. No write path - The editor’s syntax-error marker stays on the token the message names when the text before the error holds characters outside ASCII (accents, symbols), whichever way the engine counts the position. On DuckDB 1.5.6 nothing changes. Analyse data in the analytics workspace
- A database error that names the engine’s own schema in quotes (
"main".x,"temp".x) is shown as “the query cannot run as written”, like the form without quotes, and never with the internal names. No write path
Changes of 13 November:
- NATS commands in an HA pair: only the primary with quorum takes them; a node that may not dispatch answers refused (
HA_NOT_PRIMARY), never drops. Send commands as NATS requests: a plain publish gets no answer, so a refused command is not reported back. With no node dispatching, a request gets “no responders”; retry it. - A wrong e-signature on a tag that needs none is
403 signature_rejected, no longer401, and is journaledWRITE_DENIED_SIGNATURE_REJECTED. The tag write counter uses that code in place ofSIGNATURE_REJECTED. A client that treated401as a wrong password must read403withstatus: "signature_rejected". - Integrators who connect to the broker with their own NATS user or NKey: check the role’s rules. A tag-path subscribe rule (
Plant/Area/>) now gives exactly that tag’s telemetry (uns.telemetry.Plant.Area.>), and a tag-path deny now denies it. A role with no subscribe rule now receives no telemetry. A tag-path publish rule grants nothing on the broker: a client that sends commands needs the subject ruleuns.command.write. A rule that cannot be written as a subject fails closed and is logged as a warning. Roles whose rules are only>or subjects, as on a new installation, are unchanged. - No user connection gets JetStream or the broker’s other own subjects (
$JS.>,$JSC.>,$KV.>,$O.>,$SYS.>,$SRV.>,$MQTT.>,$NRG.>), whatever its role,>included. A client that read the buffer of theTELEMETRYstream, or a key-value bucket, must subscribe to the live subjects instead. - Publishing telemetry needs a rule that names
uns.telemetry. A user allowed>(oruns.>) can no longer publish onuns.telemetry; a user with>from one role and auns.telemetryrule from another publishes no telemetry (logged). Connect producers of telemetry, such as an eaxPLC edge runtime, as devices with their NKey, not with a user name and password. - A NATS channel ingests a telemetry message only when its subject names the tag of its payload (
uns.telemetry.Plant.FT101.PVforPlant/FT101.PV). Messages that name another tag in their payload are dropped and counted ineaxscada_uns_ingest_refused_total{reason="TELEMETRY_SUBJECT_MISMATCH"}; check that counter after the upgrade. The subject names the whole path whatever the channel’s inbound prefix (uns.telemetry.Site.Line.plc-01.>takes eaxPLC’suns.telemetry.Site.Line.plc-01.CounterforSite/Line/plc-01/Counter). The registry of simulated PLCs applies the same rule. - A NATS channel never writes to a
uns.telemetrysubject, numbers or text, and a write its broker refuses is reported as failed (it was reported as written). Write to a tag throughuns.command.write. - A screen rollback names a commit hash of 7 to 40 hexadecimal characters (
400otherwise), is recorded before anything changes, and is refused with503 AUDIT_NOT_WRITTENwhile the audit trail is down. A screen file that cannot be written now fails the save instead of answering saved. - The project’s startup page cannot be deleted (
409 startup_page): set another startup page first.
The shift log (14 November, eaxScada 4bc9c10b; safety: authorization, e-signatures, audit trail, HA). A new feature, Enterprise only; nothing changes for a server that does not use it, except notes 325 and 327:
- The shift log is Enterprise only. On Free (its evaluation sessions included), Starter and Pro every
/api/shiftlogroute answers403with codeEDITION, the Administrator included; so does a server without an edition service. The runtime shows no Shift log button and the Studio shows no Project > Shift log… menu item (note 393). When the licence changes - The server decides at start whether it writes the shift log, and keeps that answer until it restarts. A licence that expires, is removed or becomes invalid while the server runs leaves the shift log writable until the restart (the panel says “Read-only from the next restart”); an Enterprise licence installed while it runs takes effect at the next start. A server that starts outside Enterprise with shift log records in its audit trail is read-only: the
GETroutes answer, every other method answers403 EDITION, and no missing-handover record is written. A handover signed out but not taken over is shown “Not completed: the licence changed”. When the licence changes - Five new rights:
shiftlog_view,shiftlog_write,shiftlog_sign,shiftlog_review,shiftlog_admin, feature rules in Security. A new installation gets rules for them (Shift_Operator view, write and sign; Process_Supervisor also review; Lead_Engineer and Administrator all five). An upgraded installation gets none: only the Administrator holds them until you add rules. The catch-all*andshiftlog_*do not grant them, a DENY rule refuses them to the Administrator too, and the AI co-pilot can holdshiftlog_viewat most. Each log can narrow them with its own readers, writers, signers and reviewers. Grant the rights - Which entries are password-signed: deviations, safety items, instructions, both sides of a handover, and corrections and closures of signed entries. Notes and maintenance entries are attributed to the signed-in user without a password unless the log requires one. An instruction is recorded only by a person with
shiftlog_reviewand needs a valid-until date. Signing on a log needsshiftlog_signand at least the log’s minimum level (Shift_Operator, 40, by default). Entry types - Six new signature decisions (
shiftlog_record,shiftlog_review,shiftlog_handover_out,shiftlog_handover_in,shiftlog_correct,shiftlog_close), issued throughPOST /api/shiftlog/sign-ticketover the content hash the server prepared, as one-timeeso_tickets valid 60 seconds. They are issued and redeemed only over shift log objects, and no other decision is accepted over one. The author never reviews their own entry and the outgoing operator never takes over their own shift (403 SHIFTLOG_SAME_PERSON, on the user id and on the user name without regard to case). Signing - Every shift log write is recorded first in the audit trail, category
SHIFTLOG, actionsENTRY_RECORDED,ENTRY_CORRECTED,ENTRY_VOIDED,ENTRY_REVIEWED,ITEM_CLOSED,ITEM_EXPIRED,HANDOVER_SIGNED,HANDOVER_ACCEPTED,HANDOVER_DECLINED,HANDOVER_WITHDRAWN,HANDOVER_MISSINGandINDEX_REBUILT. When the record cannot be written nothing is stored and the answer is503 AUDIT_NOT_WRITTEN(the draft is kept); a server whose trail does not record answers503 SHIFTLOG_NO_TRAIL. A change of the shift log settings is recorded first asSHIFTLOG_SETTINGS UPDATE. Audit actions - A shift log entry is never edited or deleted:
PUTandDELETEon/api/shiftlog/entries/{id}answer405withAllow: GET. Corrections, voids and closures are new entries; the corrected entry stays visible, struck through. Corrections, voids and closures - The handover binds two signatures to the same content: the summary, each open item’s status line and the hashes of the shift’s entries. An entry added or an item closed between the two signatures refuses the take-over (
409 SHIFTLOG_STALE). Co-signing at the outgoing operator’s console is on by default per log and refused through eaxCloud remote access (403 cosign_inline_remote); every handover step is refused remotely (403 remote_never). A handover can be signed out from 60 minutes before the shift end by default. The handover - A missing handover is recorded, not alarmed: at the shift end plus the grace (30 minutes by default) without a completed handover, the server records
HANDOVER_MISSINGas the system, with the open items; no alarm is raised. An instruction past its valid-until is recordedITEM_EXPIRED. A log can turn off the required handover. The handover - API tokens may read the shift log with
shiftlog_viewbut never write or sign in it, and the AI co-pilot never writes or signs (403 SHIFTLOG_SIGNER). With security off every shift log route answers403 SHIFTLOG_SECURITY_OFF. The checks, in order - Remote access classes: the reads are view; drafts, prepare, sign-ticket, entries, corrections, closures and reviews are operate; the handover, the verification, the index administration and the export are never remote; the settings are read at engineer class and never changed remotely;
POST /api/reports/starters/shift-logis never remote (note 341). Allow remote access - HA: shift log writes happen only on the primary with quorum (
409 ha_standby). Two new NATS key-value buckets in theEAX_COLLABaccount,shiftlog_drafts(drafts expire after 14 days) andshiftlog_handover, have three replicas on a cluster of three servers or more and are refused (503 SHIFTLOG_UNAVAILABLE) when they do not answer as such. A take-over on a server that does not yet hold the outgoing record answers409 SHIFTLOG_HANDOVER_SYNCING. The missing-handover check runs on the primary only. High availability - New files in the data folder:
data/shiftlog/settings.json(the settings, a project document in checkpoints and in the HA configuration store) anddata/shiftlog/index.duckdb(the read index, derived from the audit trail, encrypted when historian encryption at rest is on, rebuilt from the trail when missing or when its check fails). Back up the audit trail: the index can always be rebuilt from it. Every entry is a record in the audit trail - Analytics and Reports gains the dataset family
shiftlog, the schedule triggershiftlog_handoverand the routePOST /api/reports/starters/shift-log, all Enterprise only. Nothing is added to a project until an engineer clicks Add shift log report. Add the shift report - “Add to shift log” from alarms, faceplates and screen scripts; not in this release. “Add to shift log” exists from an alarm (the row action Shift log in an alarm summary, and Add to shift log in the alarm’s detail card; it acknowledges, shelves and silences nothing), from the operator faceplate dialog (the faceplate’s tag), and through the screen-script function
system.shiftlog.add({type?, refs}), sandboxed scripts included. Each one opens the New entry dialog with the references attached and records nothing itself: the operator records. A batch is added through the function ({kind: 'batch', id}); there is no batch button. Not in this release: the period export (POST /api/shiftlog/exportsanswers501 NOT_IMPLEMENTEDafter its checks), assistant drafts of a handover and shift log tools for MCP clients. References to lots, units and report runs are refused (400) rather than recorded without a snapshot. Add to shift log, system.shiftlog.add - References read through the author’s rights, and never write: a tag, alarm, batch or screen the author may not read is refused (
400); the snapshot keeps a bad or uncertain quality as it was read. Nothing in the shift log writes a tag, acknowledges or shelves an alarm, or starts or stops a batch. What the shift log never does
Shift log follow-ups (14 November, eaxScada 7d8a6411; safety: authorization, audit trail):
- The shift log starter route is never remote.
POST /api/reports/starters/shift-logis listed as never in the remote-access table, like a change of the shift log settings: it writes datasets and a report to the project on this server. Shift log API - A missing handover is never recorded for a shift that ended before the log existed, or before the current licensed period began. A log deleted and added again exists from the moment it was added again. The start of the licensed period is kept across restarts in
data/shiftlog/licensed_since.json: an Enterprise start keeps it, a start without Enterprise removes it, and the next Enterprise start begins a new period. When the audit trail is too long to find when a log was created, the 24-hour lookback alone applies and the server logs a warning. The handover GET /api/shiftlog/logsgives each log’sarea(tag_prefixesandalarm_areas,[]when none), only for the logs you may read. The runtime uses it to choose the log of an “Add to shift log”. Shift log API- The server checks the shift log settings with the same limits as the Studio: a log name of 1 to 80 characters (it allowed 120), a grace and a sign-out window of 0 to 480 minutes, 0 meaning the default (it allowed 1,440). A settings document over these limits is refused (
400). In the Studio form the grace and the window are 1 to 480. The settings document
Modbus block reads (14 November, eaxScada 5e54038d; safety: values operators see):
- Modbus devices now read in blocks when block reads are on. Modbus TCP, the Modbus TCP gateway, Modbus RTU, Modbus ASCII and Modbus RTU over TCP now honour the device’s Enable Block Read Optimization (
block_read_optimization), which is on for a device created in the Studio. Before, it was ignored and every tag was its own request. Now there is one request per block of neighbouring tags of one unit id and one area: at most 125 registers or 2,000 bits, and at most the device’s Max Block Read Size (64 for a device created in the Studio). Each tag takes its own registers or bits from the answer. After the upgrade, check the values of each Modbus device; to go back to one request per tag, turn block reads off on the device. Modbus block reads - New channel settings
block_gap_registers(default 16) andblock_gap_bits(default 64) on Modbus TCP, Modbus RTU and ASCII, and Modbus RTU over TCP: the most unmapped registers or bits one block spans between two tags; 0 reads only tags next to each other together. Driver channels, devices and tags - A block the device refuses with exception 01, 02 or 03 is read again tag by tag in the same poll, so one bad address makes only its own tag BAD. The refused addresses are remembered: they are read alone from then on, and no block spans them. Any other failure of a block (a timeout, a lost connection, exception 04 or 0B) makes every tag of the block BAD. Modbus block reads
- A block answer is used only within its poll cycle, and a Modbus one only within the request timeout: a tag never gets a value from an earlier poll. The Omron FINS and MC protocol / SLMP block reads also end with their poll cycle. A write ends the poll’s Modbus blocks: the reads after it in that poll are made one by one.
- On a Modbus channel the inter-request delay (
inter_request_delay_ms) applies per request sent, not after a tag served from a block already read. A Modbus channel with a delay polls faster when its tags are read in blocks. Other drivers are unchanged.
Shift log security review fixes (15 November, eaxScada 6034093b; safety: authorization, e-signatures, audit trail). Enterprise only, except note 352, which also covers Analytics and Reports (Pro and Enterprise):
- A draft is recorded once. Two requests that record the same draft at the same time (a double click, a retry on a slow answer, two tabs) made two entries. Now a commit takes the draft’s claim, one holder across the cluster, and checks the audit trail again: the second request answers
409 SHIFTLOG_STALE“this draft is being recorded by another request”, and so does a change, a prepare or a delete of that draft meanwhile. A later repeat answers the first entry. A claim left by a request that ended without releasing it expires after 2 minutes. Drafts - Changing the shift log settings needs
shiftlog_adminas well as the Lead_Engineer or Administrator level (PUT /api/dev/shiftlog/settings; it needed the level only). A DENY onshiftlog_adminrefuses it to the Administrator too. On an upgraded installation, grantshiftlog_adminto your engineers (a feature ruleshiftlog_admin, ALLOW, on Lead_Engineer): until then only the Administrator can save the settings. New installations already grant it. Grant the rights - A catch-all or prefix DENY now refuses every shift log right and every Analytics and Reports right, the Administrator’s included. A DENY feature rule with the pattern
*,feature:*or a prefix ending in*(shiftlog_*,reports*) used to be ignored by these rights; it now refuses each right it covers. Such a pattern in an ALLOW rule still grants nothing. Check for DENY*rules before the upgrade: a person they cover loses the shift log and Analytics and Reports. The checks, in order, Grant report rights - A standing instruction is closed or corrected by a reviewer of the log or by its author only (any writer could). Its valid-until date changes only with
shiftlog_review: the author without it corrects the text and keeps the date (403 SHIFTLOG_RIGHT). A correction of an instruction keeps a valid-until date (400 SHIFTLOG_INVALIDondue); a void ends it. Entries, corrections, closures, reviews - Verification is rationed, and the audit trail’s own chain is for
shiftlog_adminonly.GET /api/shiftlog/verifyreturnstrail_chain, and its problems of kindtrail_chain, to ashiftlog_adminonly; for anyone else that check is skipped. Each user verifies at most once every 30 seconds and one at a time: sooner,429 SHIFTLOG_BUSYwithRetry-After. Verification and the index system.shiftlog.addopens one dialog at a time, only right after a click or tap, at most 3 times a minute per page. Otherwise it rejects and opens nothing, with the codebusy(a shift log dialog is open, a signature is being sent, or the script’s previous call is still open),no_gesture(no recent click or tap: a startup script or a timer) orrate_limited(note 390; earlier builds rejected all three asrefused_policywith abusy:style message prefix). A legacy script outside the sandbox getsbusyonly. Add to shift log from an alarm or a faceplate also refuses while a shift log dialog is open (“A shift log dialog is already open: finish or close it first.”). system.shiftlog.addcontent_hashis required on a handover accept and decline: 64 lower-case hexadecimal digits, the pending handover’s content you reviewed. Missing or of another form:400 SHIFTLOG_INVALID. An empty hash used to match any pending handover. The handover- One review per reviewer. A second review of the same entry, as recorded, by the same person answers
409 SHIFTLOG_ALREADY_REVIEWED(new code), checked against the audit trail; so does a second review sent while the first is being recorded. Two records without a user id or a name are never taken for the same person (note 391). Entries, corrections, closures, reviews GET /api/shiftlog/entries/{id}falls back to the audit trail. When the index does not hold the entry yet, the server waits up to 2 seconds for it to catch up, then reads the entry from the trail in the logs you may read and answers{entry}withoutstateandchain. An entry the trail holds is never answered404, also when the index is not available. Reads- Signature password fields start empty and stay empty: the e-signature dialog and the co-sign fields at the console clear a password the browser fills in by itself, and the co-sign fields are no longer a form a browser offers saved credentials for. Take over a shift
- Deleting a draft is checked like any write: refused on a read-only server, on a standby, to an API token and to the AI co-pilot, and while the draft is being recorded (note 350). Drafts
- Reading a handover writes nothing.
GET /api/shiftlog/logs/{log}/handoverworks the state out from the audit trail for the answer; the watcher, every minute on the server that writes the shift log, stores it for the current and the previous shift. Reads - A closure is refused when the item’s state cannot be read from the index (
503 SHIFTLOG_UNAVAILABLE): an item is never closed without knowing whether it is still open. Before, the closure went ahead. Entries, corrections, closures, reviews system.shiftlog.addaccepts the reference kindstag,alarm,batch,screenandentryonly, the kinds the server records.lot,unitandreport_runare refused withinvalidbefore the dialog opens (they were refused by the server, with400, after the operator filled in the dialog). system.shiftlog.add
Live values per view (15 November, eaxScada 561bc412, every edition; safety: values operators see):
- The server sends each browser tab only the tags its views subscribe.
TAG_INIT(every readable tag when the socket opened) andTAG_UPDATE(one message per change) are gone: a view sendsSUBSCRIBE, the server answersTAG_SNAPSHOTand then sendsTAG_UPDATES. The read right is checked when a tag is subscribed; a refused tag never gets a value. Through eaxCloud remote access the subscriptions are carried to the site. Browser tabs opened before the upgrade receive alarms but no tag values, and show their values as stale until they are reloaded: reload every operator console and wall screen after the upgrade. A client of your own that readTAG_INITorTAG_UPDATEmust subscribe. Live data socket - Values can reach screens up to about 100 ms later. The changes of a tab’s tags are sent together once per batch window: the latest value of each tag, with its own quality and timestamp. New keys in
server::ws_batch_ms(default 100, 50 to 1000),ws_max_tags(default 50000, at most 500000) andws_max_views(default 256, at most 4096);0is the default, and a value out of range stops the server at start. Settings - The browser may now send on
/ws: frames of at most 64 KiB (it was 4 KiB), at most 20 messages a second with a burst of 40. A larger frame closes the socket (1009); a message over the rate is refused (SUBSCRIBE_REFUSEDrate). Tags pastws_max_tagscome back inlimitedand are shown Bad “too many tags on this page”; a view pastws_max_viewsis refused. Limits hmiBus.getAllTags()returns the subscribed tags only, not every tag of the project, and so does the tag map of an HTML widget.system.tag.readandreadManyof a tag no view shows wait for the server’s snapshot and keep the tag subscribed for 30 seconds. How live values reach screens- A tag’s unit and description are refreshed when the tag is subscribed, not with each change: a unit or description edited while a page is open shows the next time a view subscribes the tag (the page opened again, or reloaded).
- Right after a navigation, a new screen waits for the snapshot of its tags (note 372: it is held hidden for at most 2 seconds, then a value still missing shows Bad “No value received”). A tag the account may not read, a tag the server does not know and a tag over the limit are shown Bad with no value, never with an old value; after a reconnect, values stay stale until every view has its snapshot again. Show bad and stale values
- Sizing. The server’s work now follows the tags on screen, not the size of the project. Measured on a project of 100,000 tags changing 10,000 times a second, a control room of 20 screens of 300 tags each costs about 0.07 server cores (it was 2.40) and 2.8 kB/s per tab (it was 2.08 MB/s). What a control room costs
Tag registration (15 November, eaxScada 9a677d40, every edition):
- Registering tags takes time in step with their number. 100,000 tags register in well under a second at start-up or on import (it took 11 to 14 minutes), and the tag engine holds about 175 bytes per tag. Nothing changes in the API or in what a tag holds. What a control room costs
New screens and their first values (15 November, eaxScada 2703ead2, every edition; safety: values operators see):
- A new screen is held hidden until its values are in. A page, dock, popup or inner screen drawn for the first time stays hidden, and cannot be operated, until the server has answered for the tags it reads, for at most 2 seconds. Then it is shown; a value still missing shows Bad “No value received”, never a designed value. The page’s tags are subscribed from its screens’ documents before they are drawn (they were subscribed at each object’s first read). With the link down a screen is shown at once, its values stale. What the operator sees
- Inner screens show live values. The objects of an inner screen (a screen shown inside another) kept the values they were designed with and never showed a tag’s value or quality. They now update like the page’s objects and show Bad when their tag is Bad. Check your inner screens after the upgrade: an object that showed its designed value now shows the plant’s value, or Bad. Show bad and stale values
- A 3D vessel whose level has no usable value shows a hatched amber band around its shell (no value received, Bad quality, not a number), instead of no liquid, which looked like an empty tank. Its label names the quality: “— No value received” instead of a bare “—”. Live data in 3D
- The reasons of a Bad value are translated in the runtime’s five languages: not readable for this account, too many tags on this page, unknown tag, not subscribed, no value received.
Multi-state indicators and popups (15 November, eaxScada ccf1fb5d, every edition; safety: values operators see):
- A multi-state indicator without a value shows its fallback state, never its first state. A tag released, refused or unknown has no value; it used to read as 0 and drew State 0, often “STOPPED” or “CLOSED”. The fallback state is the one chosen as Default fallback state in the indicator’s dialog (on a new indicator, the fallback state with the caption
?). An indicator whose fallback state was deleted still shows its first state: check that each indicator has a fallback state that cannot be taken for a plant state. Multistate indicator - A tag update touches only the multi-state indicators of that tag, not every object of the screen. Measured on a screen of 2,000 objects at 5,000 changes a second: about 4,500 updates a second reach the screen (about 1,000 before), and the page’s main thread is 52 % busy instead of 97 %.
- A popup subscribes its tags from its screen document when it opens, before it is drawn, and releases them when it closes. A tag the page also reads keeps its value. How live values reach screens
Historian disk budget (15 November, eaxScada 5d190b63; safety: historian values operators see):
- The purge on a critically full disk now works with the columnar store. It deleted only CSV history, so on a columnar store it deleted nothing and logging stayed paused while the disk stayed full. With
purge_on_criticalit now deletes the oldest days, never today or yesterday, only until the store has room inside its file for about two days of new history (twice the daily ingest, at least 64 MB). This frees no disk space: the store’s file stops growing, it does not shrink. Each purge is audited asHISTORIAN_PURGEwith the reasondisk_critical. Disk space critical with the columnar store - When the store holds less than the disk’s shortfall, the purge record and the log say that something else is filling the disk. The amount purged never depends on the shortfall, so a disk filled by another program does not empty the history. A purge that frees no room in the store waits an hour before the next attempt.
- The pause on a critical disk counts the store’s free blocks. History may go on being written into the room inside the store’s file while the volume itself keeps at least half the critical line free; under that, logging pauses as before. The pause message gives both figures.
- A config file without a disk budget is warned about at every start: no
retention(global or per tag) and nomax_sizelogs the warninghistorian has no disk budget, with what then happens and the keys to set. historian:keys after a sub-section the server does not read are read. Aretentionormax_sizewritten below such a sub-section (for exampleparquet_export:in older sample files) was silently ignored, so history was kept until the disk was full. Check thehistorian disk budgetline in the log after the upgrade: a budget that was ignored now applies, and the first purge, about 30 seconds after the start, can delete days. An unreadablemax_sizeis now logged as a warning. Server configuration- On Linux the free space is computed from the filesystem’s fragment size. On a filesystem whose block size is larger (some network filesystems) the byte thresholds (
critical_free: 5%, 5GB) read a wrong free space; percentages were right. - Shipped config files set a disk budget, for new installs only (an existing file is never changed):
retention: 90d;max_size10 GB (Linux archive, appliance, community image) or 20 GB (Windows archive, Pro Docker image, high-availability sample);warn_free: 15%;critical_free: 5%with a floor of 2 GB or 5 GB; purge and pause on; logging defaults 1 s, deadband 0, 10 min. Leave about three timesmax_sizefree: the nightly snapshot keeps two copies of the store. Keep the historian within its disk budget
MQTT ingest, feature DENY rules and shift log scripts (15 November, eaxScada f99c08fa; safety: values operators see, authorization):
- An MQTT message writes only the tags its channel maps to its topic (the mapping’s address is the topic). A payload
pathmust be one of those tags; a topic no tag of the channel is mapped to creates no tag. Before, the payload’spath, or the topic minussensors/, was written whatever it named: another channel’s tag, or a new tag. Before the upgrade, map every tag an MQTT channel must take to its topic, or set Also accept unmapped tags under (ingest_path_prefix): until then the messages of an unmapped topic are dropped. Which tags a message may write - Sparkplug B values are written only to paths the channel maps, or under its
ingest_path_prefix. Another channel’s tag is refused, whatever the prefix. - New metric
eaxscada_mqtt_ingest_refused_total{channel, reason}with the reasonsUNMAPPED_TOPIC,PAYLOAD_PATH_NOT_MAPPED,OTHER_CHANNEL_TAG,UNMAPPED_PATHandNO_MAPPINGS, and a warning in the log at most once every 10 seconds per channel and reason. Metrics - A catch-all or prefix DENY now refuses the genealogy and the recipe and batch rights. A DENY feature rule with the pattern
*,feature:*or a prefix ending in*(genealogy*,batch*,recipe*) was ignored by these rights, which matched only the right or its family (genealogy.*,recipe.*,batch.*). It now refuses each right it covers, as for the shift log and Analytics and Reports (note 352). Such a pattern in an ALLOW rule still grants nothing. Check your DENY*rules before the upgrade: a person they cover loses genealogy, recipes and batches. The default rules hold no feature DENY. Feature DENY rules system.shiftlog.addrejects with its own codesbusy,no_gestureandrate_limited, no longerrefused_policywith abusy:message prefix; a legacy script outside the sandbox getsbusyonly. A script that does not catch the rejection shows the operator a plain, translated warning instead of a script error. A script that testedrefused_policyor the message prefix must teste.code. system.shiftlog.add- A shift log review is refused as a second review by the same person only when the user id or the name matches: two records with no id or no name are not one person (Enterprise).
Feature DENY rules and the Administrator (15 November, eaxScada 3cd5d679; safety: authorization):
- A matching feature DENY refuses the genealogy and the recipe and batch rights to the Administrator too, as it already does the shift log and Analytics and Reports rights: the right itself, its family,
*,feature:*or a prefix ending in*. Without a matching DENY the Administrator holds every right, as before. The Administrator keeps security administration, so can always remove the rule. The default rules hold no feature DENY, so no Administrator loses a right at the upgrade unless a rule of yours matches. Feature DENY rules
Shift log: Studio menu, polling and the period export (16 November, eaxScada 956c7daa: merges d81c6eb0, bba46068 and df5f2fc0, Enterprise; safety: authorization, audit trail):
- The Studio shows Project > Shift log… only when the licence has the shift log (Enterprise), as it does Genealogy and Analytics and Reports. Before, the item was listed in every edition and opened a locked card. The runtime stops asking for the shift logs (
GET /api/shiftlog/logs) for the rest of the session after an answer that the shift log is not licensed (403 EDITIONor404). Set up shift logs POST /api/shiftlog/exportsis served: the period export of one log,{log, from, to}(toexcluded, at most 366 days), as a ZIP file ofentries.jsonl,records.jsonlandmanifest.jsonwith the SHA-256 of each file, filtered by the audit record’s time. It answered501 NOT_IMPLEMENTED. The route needsshiftlog_adminas well asshiftlog_view(the route list saidshiftlog_view); a matching feature DENY refuses them to the Administrator too. People only: never an API token or the AI co-pilot (403 SHIFTLOG_SIGNER), never on a standby (409 ha_standby). Enterprise, or a server read-only after a licence change. Period export- An export is recorded before any byte is sent: the record
SHIFTLOG EXPORTEDwith the export id, the period and the manifest’s SHA-256. If it cannot be written, the answer is503 AUDIT_NOT_WRITTENand no file is sent. The answer carriesX-Eax-Export-Id,X-Eax-Manifest-Sha256andX-Eax-Audit-Record. - The runtime panel’s More > Export period… for log administrators (also on a read-only server): presets This shift, Previous shift, Today, Last 7 days and Custom, the file downloaded under the server’s name, the export id and manifest SHA-256 shown with copy buttons. Export a period
Rights when the permission rules cannot be read, and the MQTT ingest check (16 November, eaxScada 956c7daa: merge 3290a3f7; safety: authorization):
- The genealogy and the recipe and batch rights are refused when the permission rules cannot be read, to every user, the Administrator included, as the shift log and Analytics and Reports rights already were. The reason is “permissions could not be read; <right> refused”, and a WARN is logged. Before, rules that could not be read were skipped, so a DENY fell through to the role’s default rights. A store with no rules still means the defaults. Feature DENY rules
- The MQTT ingest check answers without blocking other messages in steady state. No change in what it accepts or refuses, or in
eaxscada_mqtt_ingest_refused_total.
config.yaml (16 November, eaxScada 956c7daa: merges 25d1b597, 40ed3978 and 956c7daa, every edition):
-
A config.yaml key the server does not read is named at start-up: one WARN per key with its line and, when a known key is close, “did you mean <key>?”; an unknown section once, with the number of keys under it. The server always starts and no setting changes. How eaxScada reads config.yaml
-
Keys are read in the section their indentation puts them in. Check your file if it writes keys after a sub-section: these now read differently.
nats.portafternats.cluster:sets the NATS server’s port (it was read as the cluster’s port, and the NATS server stayed on its default port);nats.host,nats.http_portandnats.http_hostafternats.cluster:are read (they were ignored);- a one-line
nats.leaf_nodes: [...]afternats.cluster:is read (it was ignored); logging.levelafterlogging.syslog:sets the main log level (it was read as the syslog level);logging.fileandlogging.file_enabledafterlogging.syslog:are read (they were ignored);- a section’s keys after a sub-section the server does not read are read, such as
server.hostandserver.portbelow atls:block (they were ignored); - a top-level
tier:after a section is read, and one inside a section is not (tiernever sets the edition); - a known key below a header the server does not read is ignored and named at start-up (
port:undermetrics:extra:server:was read asserver.port); - a known sub-section nested deeper than its place (
historian:disk:store:) is ignored and named (it was read as that sub-section).
Every shipped sample, template and installer output reads the same as before.
-
nats.routes:and a top-levelroutes:are lists of cluster routes, read from their-items as before, and no longer named as unknown. Written on one line (routes: [a, b]), which was never read, they get their own WARN: “write each entry as a “- “ item”. -
The shipped sample config files hold only keys the server reads (the full-build Docker image, the Windows sample, the standard-build image), with no edition (it comes from the licence) and no account or password: the first password is generated into
data/security/initial_admin_password, or taken fromEAX_ADMIN_PASSWORD_FILE, and must be changed at the first sign-in. No sample setsadmin/admin. An existing file is never changed. First sign-in
Drivers (16 November, eaxScada 956c7daa: merge 61810856; safety: values operators see):
- Omron FINS and Mitsubishi MC protocol (SLMP) connections wait the inter-request delay only after a sent request, not after a tag served from a block already read. With 20 words in one block and a delay of 100 ms, a poll took 2.02 s; it now takes about 0.1 s. Omron FINS
- The Studio’s Modbus connection forms (TCP, gateway, RTU, ASCII, RTU over TCP) have Block gap (registers) (0 to 125, empty: 16) and Block gap (bits) (0 to 2000, empty: 64). A value out of range is refused on save. Modbus block reads
Page switches and modal popups (16 November, eaxScada 956c7daa: merge fc2a163d, every edition; safety: commands to equipment, values operators see):
- A page switch whose tag list needs more than one frame sends only the difference:
SUBSCRIBEwithappend: trueandremove, the leavers released first, then the joiners snapshotted; tags both pages share keep their subscription and get no new snapshot. For two pages of 20,000 tags sharing 15,000, a switch snapshots 5,000 tags instead of up to 20,000. Tags held by popups or inner screens are never dropped, and the limits are unchanged. Clients that send only replaces still work. Live data socket - SAFETY: a modal popup now blocks taps over the whole screen. Before, a band of the page stayed tappable under a modal popup, with the command buttons in it: in the phone’s cards view the cards above about y 267, on a desktop the area above alarm banner objects. Check after the upgrade that no operator procedure relied on reaching the page while a modal popup is open. Popups
- Popups keep clear only of the alarm banners the operator can see. A banner hidden under something else (the phone’s cards view, a sheet) no longer moves popups down.
Deploy files (16 November, workspace):
- The Docker Compose files and the deployment README describe high availability plainly: the HA compose file is two eaxScada nodes and a witness with an active-passive lease (3 s by default, renewed every 0.5 s); the plain Pro compose file starts two independent nodes, with no high availability. Claims of a hot standby with a 10 ms heartbeat, failover in under 50 ms and ports 4242/4243 were removed: they did not describe the product. Enterprise: high-availability pair
Web content objects (16 November, eaxScada 7fa39855: merge 56a1c022, every edition; safety: values operators see):
- Web content (HtmlWidget) objects have a Tags list, in the Properties tab (saved as
props.tags). Its tags are subscribed with the object’s screen wherever it is shown (page, popup, inner screen, dock) and sent to the frame without asking, sodata-tagelements,eax.onandeax.valuehave their values at once. Before, since screens subscribe only the tags their objects name, a value the HTML read by path arrived only when another object used the same tag. The Tags list - A screen saved before the list existed subscribes the paths its HTML names literally:
data-tagattributes, andeax.on,eax.valueandeax.tagwith a quoted path. The inspector shows them as detected until Use these tags keeps them as the list. With a list, paths found in the HTML but not listed are named, each with Add. A path built at run time cannot be found: list it. - A path the HTML asks for at run time is held while the object is shown. Before, it was read once and released by the page’s sweep a few seconds later, and its value went stale.
- An inline script of the HTML can call
eax.onandeax.scanwhere it stands: the calls are queued until the frame’s runtime starts after the content. Before, such a script found noeaxand failed.eax.valueandeax.taganswerundefineduntil then. Web content script API - Where-used and Find and replace cover the Tags list: a renamed tag is rewritten in it. No change to read rights: a tag the operator may not read shows Bad.
Inner screens (16 November, eaxScada 7fa39855: merges 6446dead and 7fa39855, every edition; safety: values operators see, commands to equipment):
- An inner screen switched at run time subscribes its tags before it is drawn (
system.nav.loadInnerDisplay,system.nav.swapInner): the tags its objects name, web content Tags lists included, as the container’s own viewinner:<container>. It is held hidden until they are answered, for at most 2 seconds; a value still missing then shows Bad. They are released when the page is left or the container shows another screen; a refused screen releases them too. Before, its tags were subscribed only at their first read and released by a later sweep, and the screen showed “No value received” for values on their way. The page’s default inner screen stays in the page’s view. Inner screens system.nav.swapInner(container, screen, {set} or {params})works in sandboxed scripts with its options. Onlysetandparamsare accepted, with the parameter name and value limits; another shape is refused withinvalidand nothing is loaded. The values are held to the strict character set.system.nav.loadInnerDisplay(screenId)without a container loads into the page’s one inner container. A page with none refuses withnot_found, a page with several withinvalid(naming them); nothing is loaded. Before, it went to a container namedinner-display-containerwhatever the page named (missing: over the page’s centre area), and a sandboxed script’s one-argument call was refused as a bad argument.- Inner screens are scaled to their container like the page, by their own scaling mode (fit, stretch, pan; fit on a phone), the default one and swapped ones alike, and are fitted again when the container changes size (window resize, a phone turned, a dock opened). Taps and the placement of popups next to an object follow the scale. Before, an inner screen was drawn at its design size and cut off in a smaller container.
Permissions when the security store cannot be read (16 November, eaxScada 7fa39855: merge 8efe1768, every edition; safety: authorization):
- A failed read of the security store refuses the check: the person’s roles, groups, a group’s roles or the rules of the person, a role or a group. Refused meanwhile: tag writes and reads, screens and PLC control (except for a person holding the Administrator role directly, and for PLC control Lead_Engineer and Engineer held directly, allowed before any rule is read as before); broker (NATS) connections, MCP
plc.force, genealogy, recipes and batches, Analytics and Reports, the shift log, server files andscreens.script, to everyone, the Administrator included. A record that no longer exists holds no rules and is not a failure. Before, the reads that failed were skipped: a DENY in them was not seen and the role’s defaults granted the right. When the security store cannot be read - SAFETY: MCP
plc.forceno longer skips a DENY it cannot read. Before, when the rules could not be read, the role alone allowed the force. POST /api/auth/loginandGET /api/auth/memay answerpermissions: nullwithpermissions_errorwhen the permissions cannot be read. The sign-in still opens the session, so that an Administrator can repair the store; a client must readnullas no rights. Sign-in and profile API- A session whose account cannot be read is refused (
401, “user account no longer active”) on each request while the read fails, security administration included, with a rate-limited WARN. - A
screens.scriptDENY rule refuses the Administrator too, and the catch-all*(feature:*) and any prefix ending in*now match it asscreens.scriptandscreens.*did. Check your DENY rules with*before the upgrade: an engineer or Administrator they target can no longer add or change screen scripts. Grant the right to write screen scripts - When a person’s groups or their roles cannot be read, the AI co-pilot restrictions apply (an AI role through a group cannot be ruled out), except to a person holding the Administrator role directly. Role names grant nothing meanwhile: role levels, the auditor’s reads, the shift log and server file role lists; an Administrator role held only through a group grants nothing either. Before, the failed reads were skipped and the AI restrictions did not apply.
- Refusals on unreadable permissions are logged as WARN lines with the user, the right and the cause, at most one line per check and user every 10 seconds for the frequent checks, with
refusals_not_logged. The cause is never sent to the client.
Charts, tables and web content in inner screens, docks and popups (16 November, eaxScada c7e74f27: merges f4d0cbc7 and c7e74f27, every edition; safety: values operators see, commands to equipment):
- Charts, data tables, web content, gauges and alarm objects in an inner screen are drawn in the inner screen’s own layer and follow its fit: when it loads, when a script swaps it, when the container changes size and when a phone is turned. Below half scale, and on a phone, they are laid out at their design size and shrunk together with the screen, as on the page, so a trend’s labels and a table’s text do not overlap. Taps land on them. Before, they stayed at their design size away from the inner screen, or were not shown when the inner screen replaced the page’s centre. Inner screens
- The same objects in a dock are drawn in the dock’s own layer: they scroll with a dock longer than the window, follow a dock or window resize and a rotation, take taps, and slide away with an auto-hide dock. Before, they were drawn over the page’s screen at the dock’s coordinates (at the page’s scale when the page was shrunk), stayed on the page when an auto-hide dock slid closed, and did not scroll with the dock. Docks
- A dock or an inner screen that shows another screen removes the previous screen’s objects with its canvas: its charts, tables and web content frames.
- A dock waits for its declared tags: the tags its objects name, the Tags lists of web content included, are answered before it is shown, for at most 2 seconds, as for an inner screen; a value still missing then shows Bad. Its tags stay part of the page’s view. What the operator sees
- A dock that shows the page’s own screen no longer takes over the page’s canvas. Before, the dock’s canvas was registered under the screen’s name, which is also the page’s, and a window resize then fitted the dock’s canvas as if it were the page.
- Alarm objects in a popup or an inner screen are placed from that canvas (its scale, offset and groups). Before, they were placed with the page’s zoom and position: at the wrong place and size.
Shift log signatures and fields per entry type (16 November, eaxScada 4530b039: merges b3e85fcd and 4530b039, Enterprise; safety: e-signatures):
- SAFETY: a signature asked for when an entry was prepared is required when it is recorded, even if the log’s settings stopped signing that type in between. The write without a ticket is refused (
403 signature_rejected, “a signature is required: sign with your password”) and nothing is recorded. Before, the write followed only the settings at that moment, so an entry the person had been asked to sign could be recorded unsigned. An attributed entry whose type became signed after its prepare is refused the same way, as before: prepare it again and sign. The prepare’s decision is stored with the draft asprepared_decision. Drafts prepared by an earlier build follow the current settings. Signatures and settings changes - Notes and maintenance each have their own password-signature switch in Project > Shift log…: Require a password signature for notes and Require a password signature for maintenance. Before, one switch covered both. A log that signed only one of the two types showed the switch off, and the next save in the Studio removed that signature setting. The logs grid column Notes signed is now Also signed (“Notes”, “Maintenance”, both or “No”). Signatures per type
- The fields of each entry type are edited in the Studio, on a grid under Fields of each entry type: name, label, kind (text, number, choice or date), required, choices and order, with Add field, Up, Down, Edit and Delete. A type has at most 20 fields, a choice field 1 to 50 choices, and the handover none. The logs grid gains the column Fields. Before, the fields could be set only through
PUT /api/dev/shiftlog/settings. Fields per type - The server refuses an entry without a required field, or without its signature when its type is signed, whichever client sends it; a settings change never changes a recorded entry. Both were already the case and are now pinned by tests. The operator’s dialog marks a required field as required to assistive technology too. Fields per type
- The Studio save refuses a field named
voidwith the shift log service’s message (“a unique field name of letters, digits and ‘_’ is required (not ‘void’)”). The name marks a void correction. Before, the Studio’s own check accepted it. Settings document
Shift log export verification (16 November, eaxScada 07f0cddd: merge f6061723, Enterprise; safety: Part 11 records, authorization):
POST /api/shiftlog/exports/verifychecks a period export against the audit trail of this server: the ZIP as downloaded or itsmanifest.jsonalone, as the raw body or the multipart partfile, at most 512 MiB (413 SHIFTLOG_TOO_LARGE). The answer is a report of named checks,200whether the export verifies or not:recorded,manifest_hash,manifest_content,file:entries.jsonl,file:records.jsonl,records_in_trailandtrail_reproduces. The files are compared with the trail’sEXPORTEDrecord, never with the manifest. An export this server did not record failsrecordedand every other check is skipped; the manifest alone skips the file checks andrecords_in_trail. A ZIP holding any other file, a directory or a path is refused (400 SHIFTLOG_INVALID) before anything is read; nothing is extracted to disk. Export verification- Who may verify: the node-wide
shiftlog_view(a feature DENY refuses the Administrator too,403 SHIFTLOG_RIGHT) and the log the manifest names readable (else404 SHIFTLOG_NOT_FOUND). An API token whose user holds the right may verify, as it only reads; the AI co-pilot is refused (403 SHIFTLOG_RIGHT). One verification per user at a time (429 SHIFTLOG_BUSY). Never through eaxCloud remote access. - Each verification is recorded as
SHIFTLOG EXPORT_VERIFIED(export id, form, result, failed checks, manifest SHA-256) when the server records. On a standby, or with the audit trail down, the result is still given and the report’sauditmember says it was not recorded. - On HA, verify on the node that made the export: trail positions are each node’s own, so on the other node the checks that compare positions (
records_in_trail,trail_reproduces) can fail. - Runtime: More > Verify an export… in the shift log panel, for everyone who may read the log: pick the ZIP or the manifest, Verify, and the dialog shows the verdict and each check as Passed, Failed or Not checked. Verify an export
Prefix subscriptions on /ws (16 November, eaxScada 07f0cddd: merges 2319a39e and 66b15adb, every edition; safety: values operators see, read authorization):
- A
SUBSCRIBEentry ending in/*(Plant/Line1/*) subscribes every tag under that path the user may read. Each tag under it is checked with the user’s read rights as an exact path. A tag the user may not read is only counted in the answer’s newprefixessummaries (taken,held,refused,limited), never named and never sent. Before,/*was no wildcard. Prefixes - Tags created later under a held prefix are added when readable, each with a
TAG_SNAPSHOTwhoseidisnull, sent before any of its updates. - Refused and limited prefixes:
*or/*alone, an empty part (a//*), a*or>before the end, and more than 16 prefixes in one view are refused (inrefused, with anerrorin the summary). The tags a prefix gives count againstserver.ws_max_tags; past it, the prefix is listed inlimitedwith the count. - Releasing a prefix (
remove,UNSUBSCRIBE, closing the socket) lets go of the tags the view held only through it; a tag the view also lists itself stays. The page’s client withdraws such a tag as Bad “not subscribed”, never leaving its last value as Good: when its last prefix is released, when the server refuses the prefix, and after a reconnect when the server no longer names it. New in the page’s client:hmiBus.tagsUnder(prefix),hmiBus.prefixInfoand the eventscada:tag-prefix. - New key
server.ws_max_prefixes: prefix entries one view may hold,0or missing = 16, 1 to 256. A value out of range stops the server at start-up, as forws_max_tags. Server configuration
Data tables: a Columns button, and the Studio’s shift log settings at every width (16 November, eaxScada 07f0cddd: merges e5399ea2, 640a5448 and 07f0cddd, every edition):
- Every data table has a Columns button next to Export CSV: show or hide columns by mouse or keyboard, Reset to the table’s defaults, remembered per table in the browser with the column widths, order and sort. The table is never rebuilt: filters, sort and scroll stay. The actions, pinned columns and the row’s own id column always stay shown. Work with data tables
- Columns that a table shows only for some data or rights now follow the operator’s pick: Owner in report schedules, Run as in report runs and the alarm summary’s Controller handshake. While a table does not offer such a column, it is hidden, not in Columns and never exported. Before, each refresh set these columns shown or hidden again.
- Some columns start hidden in a narrow window. The Studio’s shift log logs grid hides Grace (min) and Inline co-sign below 1100 pixels, so it fits at 1024 without scrolling sideways; Columns shows them again.
- The Studio shift log settings dialog uses the window’s width up to 1440 pixels (it was 1180), and every column of the logs grid shows beside the pinned actions at 1280 pixels and wider; a value cut short shows whole in its tooltip. Before, the Rules column was past the grid’s sideways scroll at every size. Set up shift logs
- The shift log panel’s More > Export CSV keeps the operator’s column choice: it still writes the author, the signatures and the reference count without showing them. Before, it showed and hid those three columns around the export.
- The table toolbar is in the operator’s language (Filter rows…, Columns, Export CSV, the row count) and changes with it; so are the default empty and loading texts. Before, it was in English. A column with a filter box keeps the box wide enough to type in.
Remote access: the remote-access check’s refusals in the audit trail, and the control status in a remote session (16 November, eaxScada 3af6157a: merge 3af6157a, Starter, Pro and Enterprise; safety: audit trail, remote access). What a remote session may do is unchanged:
- SAFETY: a remote request refused by the remote-access check is recorded. A request from an eaxCloud remote session that the check refuses (
403withremote_never,remote_switch_offorremote_level), with any method but GET and HEAD, now leaves aREMOTE REMOTE_REQUESTrecord: method, path, status403, the refusal, its reason, the session id, and the eaxCloud portal identity (portal user, e-mail, organisation, level, key fingerprint), never the request body. The record names no site user (site_useris empty): the check runs before sign-in. Its text reads “remote request through eaxCloud (session sid, level level): POST /api/… refused 403 remote_level: not available to a view remote session”. Before, these refusals were only in the server log; a remote request that passed the check was already recorded (“answered status”). What the audit trail records - The record is written before the
403is sent, and the refusal never depends on it. When the audit trail is down or the write fails, the request is still refused with the same answer and the server logs “remote refusal not journaled”. A server without an audit trail writes no record. GET and HEAD refusals stay in the server log only. - A remote session shows “Control status is not available remotely” in a small neutral (grey) status indicator labelled REMOTE, without a banner. The control status (
/api/ha/status) is never served through remote access, as it names the nodes, their roles and the lease. Before, the remote session showed the amber STATUS UNKNOWN banner (“The gateway’s control status cannot be read (HTTP 403). Commands may be refused.”) and asked again every 15 seconds; now it does not ask again while the page is open. Any other refusal of the status still shows the amber banner, and a lost connection still shows GATEWAY OFFLINE. The text is in English, German, Spanish, French and Italian. What people at the site see - Local sessions are unchanged: the indicator and the banners at the site work as before.
Control status in the operator’s language, and the remote note in the Studio status bar (16 November, eaxScada b87d8d95: merge b87d8d95, every edition; the status bar note Starter, Pro and Enterprise; safety: values operators see). When control is accepted or refused is unchanged:
- The control-status texts follow the operator’s language (English, French, German, Spanish, Italian): the Studio header badge, the runtime HUD, the kiosk indicator’s tooltip and the banners (GATEWAY OFFLINE, STATUS UNKNOWN, CHECKING…, ONLINE - PRIMARY, GATEWAY ONLINE, STANDBY - NO CONTROL, QUORUM LOST - CONTROL REFUSED and the HA configuration drift). A language change redraws them at once, without asking the server again. The English texts are unchanged. Node names, addresses and the server’s
drift_reasonare shown as they are. Before, these texts were in English only. What people at the site see - When the control status cannot be read, the banner says why in the operator’s language: “not signed in”, “unreachable” (the gateway did not answer), “unreadable answer” (an answer that is not the status) or the HTTP status, for example “The gateway’s control status cannot be read (unreachable). Commands may be refused.” Before, a network failure showed the browser’s own error message.
- In a remote session, the Studio status bar keeps the alarm summary (SYSTEM NORMAL, 2 IN ALARM · 1 UNACK and so on, in its usual colours). “Control status is not available remotely” is only the tooltip of that segment, in grey. Before, the status bar replaced the alarm summary with “Control status is not available remotely” in amber. A gateway fault (offline, status unknown, standby, quorum lost) still replaces the alarm summary, in a remote session as at the site. What people at the site see
HA lease renewal whose reply was lost, and the embedded broker’s start wait (16 November, eaxScada 48d053dc: merge 48d053dc, HA clusters Enterprise, nats.start_timeout every edition; safety: HA, commands to equipment). When a node takes the lease and when a standby takes over are unchanged:
- A primary whose lease renewal landed although its reply was lost stays primary. The next renewal finds the lease at a newer revision than the one the primary holds, and reads it back from the lease stream’s leader, never from a replica that may be behind. It keeps the lease only if it is its own (same node, same term), not expired, at a newer revision; the log says “its earlier renewal landed although its reply was lost (revision N -> M): kept”. The read writes nothing. Before, the read could be answered by a replica that was behind, and a busy primary demoted with “lease revision conflict on renewal” although no other node had written: a needless failover under CPU load, right after a promotion or a failover. How the primary keeps its lease
- Anything else still demotes the primary at once, as before: another node’s lease or term, a deleted lease, a lease that does not decode or an expired lease (cause
term_superseded, the reason naming what was read). A read that fails, or that still finds the old revision, is retried until the renewal deadline (the lease’s expiry minus a sixth of the TTL, 0.5 s by default), then the primary demotes withlease_lostand accepts no more control. HA panel - An embedded broker not ready in time is shut down before the server stops with “embedded broker failed to start”, so it no longer holds the JetStream store folder (
data\nats). The new keynats.start_timeoutsets the wait (a duration, default10s, the fixed wait of earlier releases, at least1s); a value that is not a duration or is under1sis ignored with aWARNline and the default is kept. Raise it on a slow machine or with a large JetStream store. Embedded broker start - The start-up order of a new HA cluster, unchanged and now documented: a configured standby that starts more than 8 s before the configured primary becomes primary in term 1, and the configured primary runs as its standby. One primary at a time; start the configured primary first. Upgrade the cluster
Feature DENY rules on PLC control and server files (16 November, eaxScada 7a7e845e: merge 7a7e845e, every edition; safety: authorization). Security administration is not affected: the Administrator can always remove a rule:
- SAFETY: a feature DENY matching
plc_controlrefuses PLC control to the Administrator and the engineer roles too: start, stop, force I/O, deploy and rollback. It matches when it namesplc_control(orfeature:plc_control), or is*,feature:*or a prefix ending in*(plc*), on target type feature or api. Before, Lead_Engineer, Engineer and Administrator held PLC control before any rule was read, so no DENY reached them, and a prefix DENY reached nobody. Before you upgrade, check your DENY rules with*,feature:*or a prefix: an engineer or Administrator they cover can no longer start, stop or deploy the PLC. Feature DENY rules and the Administrator - A catch-all ALLOW no longer grants PLC control. Only an ALLOW naming
plc_controlexactly (action execute, write or admin) grants it below level 80. Before, an ALLOW*granted it. A role below Lead_Engineer that started or stopped the PLC through an ALLOW*needs an ALLOWplc_control. - Rules that cannot be read refuse PLC control to everyone, the Administrator included. Before, the engineer and Administrator roles were allowed before the rules were read. When the security store cannot be read
- A DENY
*,feature:*or a prefix ending in*now refuses every server file operation, the Administrator included, as a DENY of the operation or ofserver_files.*already did. Before, these patterns did not cover the server files. The catch-all ALLOW*still grants none of them. Server files: checks on every call - No lock-out: the Administrator keeps security administration. A feature DENY, even
*on the Administrator role, never closes the Security workspace, so an Administrator can always remove a rule that went too far. - Without a matching rule, nothing changes: level 80 and above hold PLC control, the server file operations follow the role levels, and the default rules hold no feature DENY, so no one loses a right at the upgrade unless a rule of yours matches.
The permission dialog’s feature rights (16 November, eaxScada 75dc7258: merge 75dc7258, every edition). What each module’s check decides is unchanged:
- Security > Permissions lists every feature right when Target Type is SCADA Feature: 36 rights in 8 modules with their description, an edition badge and the module wildcards; picking one fills the pattern with exactly that name. Rights the licence lacks, rights held by role level when the effect is ALLOW, and wildcards whose ALLOW grants nothing are disabled with the reason. A typed
*, prefix, unknown name or DENY says what it affects, in amber or rose. The list comes from the new read-only routeGET /api/auth/feature-rights(Administrator only,Cache-Control: no-store, never served through an eaxCloud remote session). Add a feature permission rule, HTTP API
DuckDB 2.0.0 (17 November, eaxScada e69c505b: merge e69c505b, every edition; safety: every database store: historian, audit trail, alarms, security, recipes, genealogy, shift log index, log console, collaboration archive). No sync, write-ahead log or checkpoint setting changed: each commit still syncs the write-ahead log before the record is acknowledged:
- The package ships DuckDB 2.0.0 (
duckdb.dllnext to the server, before: 1.5.6) and the historian’s encryption extension for it inbin\historian_ext\v2.0.0\windows_amd64\(Linux:historian_ext/v2.0.0/linux_amd64/). Thev1.5.6folder is no longer used. Ifhistorian.extension_dirorEAX_HISTORIAN_EXT_DIRpoints at your own bundle, put the 2.0.0 bundle there before you upgrade: otherwise the encrypted historian, and on an install with encryption at rest the audit trail and genealogy, refuse to start, with the expected path in the log. The extension is never downloaded at run time. Encryption at rest on offline and air-gapped installs - Files stay in the v1.0.0 storage format. Every file the server creates is still written in it, existing files are opened in place and never converted, and the previous package (1.5.6) opens every file, snapshot and audit copy a 2.0 server wrote: going back to the previous package on the same work folder works. Engine version and file format
- A file in the DuckDB 2.0 format is opened; only a format newer than 2.0’s is refused, untouched, and the store is shown refused. On 1.5.6 a 2.0-format file was refused.
- Analytics, report datasets and the AI co-pilot’s SQL follow DuckDB 2.0’s rules: the lambda form
x -> x + 1is refused (writelambda x: x + 1);~matches part of a text; an integer division or modulo by zero is an error, not NULL; any error inside a transaction ends it. Check saved queries and datasets that use these forms. SQL on DuckDB 2.0 - An audit record commits about 2 ms more slowly (median about 6.7 ms against 4.4 to 5.0 ms on the same PC, back to back); System Health’s Append p50 / p99 shows it. Historian ingest is the same or faster; short raw reads are 15 to 25 % slower; day reads, aggregates and the store’s size are unchanged.
- eaxCollab’s archive bundle moves the same way (
duckdb_ext\v2.0.0\...). - Not changed: the stores’ contents, their write paths and when a record is acknowledged.
Database stores: reopen after a failed write, refused newer files, and System Health (16 November, eaxScada 52be1403 and 8443b3c2: merges 52be1403 and 8443b3c2, every edition; safety: historian data, alarms, recipes):
- After a failed commit or an invalidated database (a full disk, a write-ahead log write error, an I/O error, out of memory) the historian, alarms, recipes, log console, collaboration archive and shift log index close and reopen their file. Writes are held until the file is open again (opened only once no connection of the old instance is open), the reopen is retried from 1 s up to 1 min, and the store is shown down meanwhile. The historian’s points wait in the spool and are written in order. Before, these stores went on using the failed instance until a restart. When a write leaves the database unusable
- A store file in a newer DuckDB format, or without a DuckDB header, is refused and left exactly as it is, with a message naming the file, its format and the engine. The security store refused stops the start. The historian’s set-aside is not offered for a newer-format file: start the newer eaxScada again, or restore the backup taken before the upgrade. When the historian store file does not open
- The start log and
GET /api/system/healthname the engine and each store: a “DuckDB engine” line and one “DuckDB store” line per store; the answer’s newduckdbblock. - System Health shows a Database stores section (display only): the engine, the newest format it opens, the pinned format, and one grid row per store with its file, format, state, reopens and last cause. A store reopening, down or refused is marked on its row; the marker’s card gives the cause, what it means and what to do. Database stores
The security store after a failed write (17 November, eaxScada fbcc6e4c: merge 29d0e358, every edition; safety: authentication, authorization). The rules themselves, and what a readable store grants, are unchanged:
- SAFETY: the security store reopens after a failed write, like the other stores (notes 477 to 480): a failed commit, a full disk or an I/O error closes its file and opens it again before any later change is acknowledged, and users, roles, groups, rules, identity-provider settings and API tokens are loaded again from the file after every failed write and every reopen. Before, the store went on with the failed instance, and a change acknowledged after the failure could be lost at the next checkpoint.
- SAFETY: while the store reopens or is down, every permission check refuses, the Administrator included: tag writes and reads, screens, PLC control, the broker, every feature right and security administration. The Administrator bypasses are off and the AI co-pilot restrictions apply to everyone. Changes to users, roles, rules and tokens are refused with nothing changed. When the security store reopens after a failed write
- Sessions and API tokens are refused meanwhile (
401, “user account no longer active”); a session is not ended and works again once the store serves. - SAFETY: sign-in fails while the store does not serve, with no session:
401“sign-in refused: the security store is unavailable; try again in a moment”, the same text whatever the password. Sign-in and profile API - SAFETY: a sign-in is refused when the store cannot save it: its last-login time, a failed attempt (which counts towards the lockout) or the reset of an expired lockout, with the same text. Before, these writes could fail unnoticed, so a failed attempt might not be counted. If sign-in says the security store is unavailable
- System Health shows the security store’s live state: the
securityrow of Database stores says open, reopening or down, with its reopens and last cause. The access audit chain goes on from the file’s last record after a reopen. Database stores
Screens held while their first values arrive (17 November, eaxScada fbcc6e4c: merges c99954de, b215f02a, 0cc6ef81 and 26a54224, every edition; safety: values operators see, commands to equipment). The 2-second wait of notes 369 and 372 is unchanged for ordinary screens:
- SAFETY: a held screen hides its HTML objects too (gauges, bars, alarm lines, buttons, web content), on a page, popup, inner screen, dock and the phone’s cards: they take no tap, click, key or focus until the values are in, and return in the same frame as the drawing. Before, only the drawing was hidden: the HTML objects showed default or stale values and their controls could be pressed.
- SAFETY: an isometric map is held with its screen (page, dock, popup, inner screen): hidden, and its blocks refuse every command (click, tap, momentary press, Enter or Space, the phone’s card) in the command path itself. Before, a map could be clicked before its values arrived and its commands judged from values not yet in.
- A screen whose answer comes in parts stays held while the parts keep coming, each within 2 seconds of the last, for at most 30 seconds in all, with “Loading values… N% (n/m)” (in the operator’s language) centred in its place. A stalled answer is let go as after 2 seconds; values still missing show Bad. Before, such a screen was shown after 2 seconds with Bad values that turned good. What the operator sees
- A held screen that is swapped, left or closed lets go at once, so the next screen in its place is neither hidden nor blocked.
- An isometric screen in an inner screen is drawn as its live map, fitted to the container, with its tags subscribed as the container’s view and released with it. Before, the container stayed blank. Inner screens
Large answers on /ws (17 November, eaxScada fbcc6e4c: merge eafba588, every edition; safety: values operators see):
- A
TAG_SNAPSHOTover 1 MiB is sent in parts, each at most 1 MiB, withpart,partsandmore; the per-prefix counts come on the last part. A snapshot that fits in one frame is unchanged. A client of your own that reads/wsmust take the answer as complete on the last part (morefalse). A snapshot in parts - A batch of changes over 1 MiB goes in several
TAG_UPDATESframes, each with whole changes, applying on its own. The batch window is unchanged. - Remote access keeps the socket of a very large screen open: it closes a socket on a message over 16 MiB, which a prefix of a large plant area used to exceed.
Historian restores and imports (17 November, eaxScada fbcc6e4c: merges 31a234b1 and 198384ee, every edition; safety: historian data). Logging, the queue, loss accounting and durability are unchanged:
- An archive restore, an import from the daily export or a CSV history import may leave
scada_history.bulk-notice.jsonin the historian folder: the time ranges written (one per tag; every tag when more than 1,000 tags were written or under encryption at rest), no values. It is expected; the server reads and removes it itself at a later start. Do not delete it. The notice file after a restore or an import
Historian heartbeat (17 November, eaxScada 7acddeb5: merges de3bb9fb and 2dfa0a0b, every edition; safety: historian values operators see). Rules without a heartbeat, deadbands, minimum intervals and periodic rules are unchanged:
- A logging rule can have a heartbeat,
max_interval_s(seconds;0or absent: none, as before): anON_CHANGEorTRIGGEREDrule for one tag logs the tag’s current value, with its own quality and whatever the deadband, when it has logged no point for that long; aTRIGGEREDrule only while its trigger is met. A rule’s heartbeat POSTandPUT /api/historian/configsrefuse a heartbeat out of bounds with400namingmax_interval_s, storing nothing: below 0.5 s or over 86,400 s, negative, on a wildcard path, on aPERIODICrule or on anALARMrule. A client of your own that sent the field before had it dropped silently. Rule API- SAFETY:
default_max_intervallogs a steady tag with no rule every interval, with the tag’s current value and its own quality (a Bad tag is logged as Bad). Before, the point was written only when an update arrived after the interval, so a tag that held still got none and its trend could look empty. A site withdefault_max_intervalset sees more points: at most one per tag per interval (at10m, at most 144 per day for a tag that never changes). Set it to0to turn it off. Tags without a rule - A tag a rule matches is never given the default heartbeat as well: the rule decides, with its own heartbeat if it has one.
Windows saves (17 November, eaxScada 7acddeb5: merge 06baf69e, every edition). Other errors and other systems are unchanged:
- Configuration and data saves on Windows retry their final rename for up to 2 seconds when another process briefly holds the file (“Access is denied”, a sharing or lock violation: an antivirus scan, the search indexer). If it still fails, the save fails with the original error, as before, and its temporary file is removed. If “Access is denied” keeps appearing in the log, exclude the install folder from real-time scanning and indexing. Antivirus and the search indexer
OEE and downtime (17 November, eaxScada 667babf9, Pro and Enterprise; safety: values operators see, authorization, audit trail, historian logging). A server that does not turn it on is unchanged:
- OEE and downtime is off by default. Nothing starts, no file is created and the historian’s logging path is unchanged until
production.enabled: trueis set, the licence includes it at start-up and the first machine is saved. A refusedproduction:value keeps the module off (the server starts and logs why). Turn the module on - Pro and Enterprise only: every
/api/productionroute answers403 EDITIONon Starter and Free (Free’s evaluation sessions included), the Administrator included. After a downgrade while it runs, capture pauses,ALM-SYS-PRODUCTIONis raised, reads stay open and every write is refused; with the licence back the gap is recomputed. When the licence changes - SAFETY: read only towards equipment. No route, panel or dataset of the module writes a tag, sends a command, acknowledges or shelves an alarm or changes a recipe. The screen action
open_downtimeis navigation only. Its only tag write is the server’s ownSystem/Production/CapturePaused. It only reads - SAFETY: seven new rights, and an upgraded installation gets no rule for them: until you add rules, only the Administrator holds
production_viewtoproduction_recompute. A new installation gets rules for Shift_Operator, Process_Supervisor and Lead_Engineer (production_recompute: Administrator only). A DENY of a right, ofproduction_*or of*refuses it to the Administrator too; the AI co-pilot holdsproduction_viewat most; API tokens only read. Grant the rights - SAFETY: a machine is shown only to a person who may read every one of its source tags, in the API, the panel, the datasets and archived reports; one you may not read answers as one that does not exist (
404 PRODUCTION_NOT_FOUND). Who sees which machine - SAFETY: a Bad sample is never counted as running or as good units; a ratio that cannot be computed is “No data” (
null), never 0 % or 100 %; performance is not capped (warningideal_cycle_too_slow); every result carries its quality (good,uncertain,bad= Incomplete data below the coverage threshold, 95 % by default). The formulas - SAFETY: reasons, planned stops and count adjustments are audit records, written before the answer: if the trail cannot write,
503 AUDIT_NOT_WRITTENand nothing changes. A change of reason after the shift closed (8 hours after its end by default) needsproduction_reason_closedand the signed-in user’s e-signature. When a shift closes for reasons - SAFETY (historian logging): Apply logging rules changes historian rules for the source tags of the machines named, and only those: recorded first (
LOGGING_RULES_APPLIED), each rule on change, deadband 0, with the heartbeat OEE needs, through the historian’s rule API; a tag’s other rules are never changed or deleted; the preview writes nothing. More points are logged for those tags. Apply the historian logging - Recompute (
production_recompute) works results out again from the historian, after a preview that writes nothing; the request is recorded first. Before an HA takeover point it needs an explicit confirmation, and a refusal is recorded. Archived reports keep their files. Recompute - In HA only the primary with quorum computes; its results are replicated to the standby, which never computes and answers with the primary’s numbers. After a failover the new primary resumes from the replicated point with its own historian and marks that slice
ha_failover. Writes are refused on a standby (409 ha_standby) and on a primary without quorum (503 ha_no_quorum). Replication metricseaxscada_production_replication_*. High availability - New files
data/production/production.duckdb(results, encrypted at rest like the historian when encryption is on; state intervals kept 400 days by default, events and OEE slices kept) anddata/production/config/. The results are not in the server backup: they are recomputed from the historian. Plan disk for them next to the historian. Retention - Datasets of the family
productionmust return their quality when they return a ratio or a count (save refused with “Add quality column” otherwise), and an archived run holding one opens only to viewers who holdproduction_viewnow. Dataset family production
NATS bridge on this server’s broker and URL credentials (18 November, eaxScada 8ab5af7a and aa8c44d1, every edition; safety: authentication, authorization, values operators see):
- A NATS bridge set to this server’s own broker (
own_broker) takes no credentials and signs in, in process, with an identity of its own that may only subscribe to its inbound subjects. Its inbound subject must lie underuns.telemetry.(any other is refused at save). It publishes nothing: every write on it is refused, and its values are never republished. Connections, lines and stations - A password inside a broker or endpoint URL (
nats://user:password@host, a NATS token asnats://token@host) is a secret: sealed on disk with the driver secrets key, shown as********in the Studio and inGET /api/dev/drivers, and as***in connection tests, events, logs and channel errors. It was stored and shown in plain text. Credentials in a URL - A masked password is kept only for the same scheme, user and host: a save that sends the mask back with another host or user drops it, and the password must be typed again, so a stored password is never sent to another server. Channel audit records carry no credentials: a password change shows mask to mask.
- A payload path relative to a multi-level
uns.telemetryprefix is now dropped (TELEMETRY_SUBJECT_MISMATCH): the subject must name the whole path (uns.telemetry.Line1.T9carriesLine1/T9, notT9). eaxPLC’s subjects, which name the whole path, are now taken in on such a channel. - Switching a connection’s protocol in the Studio and back before saving keeps its stored credentials (NATS token, OPC UA user and password); saving it under another protocol does not carry them over.
OEE and downtime before going live (18 November, eaxScada 041a1be2, Pro and Enterprise; safety: audit trail, authorization):
- A recompute needs its preview:
POST /api/production/recomputewithoutdry_run_tokenanswers409 PRODUCTION_DRY_RUN_REQUIRED; a token of another user, other machines, anotherfromorto, or older than 30 minutes answers409 PRODUCTION_DRY_RUN_STALE. Nothing is recorded in either case. Recompute - A configuration save is recorded first (
CONFIG_SAVED,CONFIG_REMOVED), then committed to the HA configuration store and applied: if the record cannot be written nothing is saved (503 AUDIT_NOT_WRITTEN); a commit that fails after the record is corrected by aCONFIG_NOT_SAVEDrecord. The answer’swarningis now always empty. Configuration documents - A recompute’s outcome is recorded as the system (actor
production):RECOMPUTE_COMPLETEDonce when written, with the rows replaced and the sums before and after per shift (at most 200 shifts listed), orRECOMPUTE_FAILEDonce at its first failure (it is retried). Audit events - Ten starter datasets on request:
POST /api/reports/starters/production(Add OEE datasets in Analytics and Reports > Schedules) adds them, never replacing a taken id; it needsdatasets_editandproduction_view, is recorded first (TEMPLATE_APPLY) and is never offered through eaxCloud remote access. Nothing is added until someone asks. Starter datasets
The data table’s own words, and the German word for an eaxCloud site (18 November, eaxScada 500b1ace, every edition):
- The data table’s own words follow the operator’s language (English, French, German, Italian, Spanish): the filter menus and their operators (Contains, Equals and the rest), AND / OR, Apply / Reset, the column menu, the pager, and the empty and loading texts. A language change switches the toolbar at once and the parts drawn afterwards; a filter menu or column menu already drawn switches when the page is reloaded. Before, these words were in English. Language
- In German, an eaxCloud site is a “Standort” in the Studio’s cloud settings and the remote-session texts (for example “Eine Person am Standort nimmt jede Sitzung an”). “Anlage” stays the word for a plant. Before, the German texts said “Anlage” for the site too.
Historian store state: isolating or down (18 November, eaxScada 3b07ffe5, every edition with the columnar store; safety: historian values operators see). The spool, its order, its size limit and the loss accounting are unchanged:
- A batch the store refuses while it still takes the probe write no longer raises
ALM-SYS-HISTORIAN-STORE-DOWN. The new system alarmALM-SYS-HISTORIAN-ISOLATING(“Historian isolating a point the store refuses - writing the others”, Medium, no sound) is raised instead. The two are never active together. An alarm list, notification or shelving rule written forALM-SYS-HISTORIAN-STORE-DOWNdoes not cover the new alarm: add it where you need it. The store’s state ALM-SYS-HISTORIAN-STORE-DOWNis raised when, after a refusal, no data point has been written for 30 s, which also covers a write or a probe that hangs. Its text says so. System alarms- While the store takes the probe write, the refused batch is tried again every 2 s instead of every minute, so the search for the refused point starts within seconds rather than after about 5 minutes. Every refusal is probed, the first live batch included.
- SAFETY: a point is quarantined only after the store has written a later point. Up to 3 refused points in a row wait for that; a 4th refused in a row means the store is down (“refuses every point”) and nothing is quarantined. Before, a store that took the probe but no data could lose one good point per round. Confirmed, then quarantined
- The quarantined point’s error is kept in
quarantine-<seq>.errbesidequarantine-<seq>.walin the spool folder, and survives a restart. Do not delete it. - The status gains the store’s state:
GET /api/historian/storage(spool.*) and System Health’s status (resources.historian.spool) carrystore_state(ok,isolating,down),down_reason,isolating_since,isolation,last_good_writeandquarantine_last.store_downis nowtrueonly when the store is down, not while it is isolating: a client of your own that readstore_downas “the store refused something” should readstore_state. New metricseaxscada_historian_store_state(0/1/2),eaxscada_historian_quarantined_points_totalandeaxscada_system_condition{condition="HistorianIsolating"}. The store’s state in the status, metrics
The Studio’s own language (18 November, eaxScada 1b22f151, every edition; safety: authentication, user preferences). The operator runtime’s language and how it is chosen are unchanged:
- The Studio has its own language (English, French, German, Italian, Spanish), chosen from the top-bar language button or View > Studio language…, separate from the runtime’s: neither changes the other. It is kept per browser and, when you are signed in, in your user preferences (
studio_lang); the server’s value wins when the Studio opens, and the Studio is in English until one is chosen. Project texts in the editor keep the preview language. Parts of the Studio still show English and follow in later releases. The Studio’s language - SAFETY (authentication):
PUT /api/auth/me/preferencesnow changes only the fields it is given ({language?, studio_lang?}).PUT {}changes nothing; before, it cleared the saved language. Astudio_langother thanen,de,fr,esoritis answered400and nothing is saved. A client of your own that cleared the language by sending{}must send{"language": ""}. The operator’s language
Repair of a file a checkpoint cut short (18 November, eaxScada 4b27da09, the release build, files without encryption at rest; safety: historian values operators see, the audit trail, genealogy). DuckDB can leave a file that does not open after a crash during a checkpoint, its data intact and one block’s checksum wrong. Nothing is ever repaired automatically, the set-aside stays as it was, and no write-ahead log or sync setting changed:
- New: the historian’s diagnosis says whether a broken store can be repaired.
GET /api/historian/storecarriesdiagnosis.repair(candidate,checking,verified,refusedornot_repairable, with the evidence and the verification), andrepair_meaning, the text an administrator signs, once the repair isverified. A client of your own that reads the diagnosis gets these new members. Historian store API - New routes
POST /api/historian/store/repair/check,/repair/signand/repair, for a signed-in administrator only, never an API token, the AI co-pilot or remote access. The check copies the store and its.walnext to it (scada_history.repair-<UTC time>.duckdb; free space for the copy plus 256 MB is needed) and verifies the copy. The repair, e-signed with a ticket bound to the repair, writes the journalscada_history.torn-<UTC time>.duckdb.repair.json, recordsHISTORIAN_STORE_REPAIRED(or, when a signed repair did not go ahead,HISTORIAN_STORE_REPAIR_REFUSED) in the audit trail with both files’ SHA-256, keeps the original asscada_history.torn-<UTC time>.duckdb(with its.wal) and puts the verified copy in its place. The history stays complete: no snapshot restore is needed. System Health has no Repair button yet; it follows in a later release. Repair a file a checkpoint cut short eaxscada audit-set-aside(the dry run) also says whether the trail can be repaired: it checks a copy in a temporary folder (every table, the hash chain from the start, the tip anchor) and removes it; nothing in the audit folder changes. On a trail that does not open, the dry run therefore copies and reads the whole file, and takes longer on a large trail. Repair a trail a checkpoint cut short- New flag
eaxscada audit-set-aside --repair --confirm --user <administrator> --reason <why>, signed like a set-aside (the text signed is “audit-repair of <file>: <reason>”). The trail continues its chain and recordsLEDGER_FILE_REPAIRED; the original is kept asaudit.torn-<UTC time>.duckdbwith a.repair.jsonjournal. Refused, nothing changed, for anything but a checkpoint cut short whose copy verifies. Command-line reference: audit-set-aside - A trail that is down at start logs a hint when it looks repairable: a second
AUDIT TRAIL DOWNline, “the audit trail may be repairable …”, with the commands to run. A historian store that looks repairable logs a warning too. Encrypted files are never repaired: an encrypted audit trail is refused by--repair(“an encrypted audit trail is not repaired (set it aside)”), and an encrypted historian store still stops the server. - SAFETY (genealogy): the genealogy store checkpoints every 5 minutes instead of every 10 seconds. Each acknowledged record stays in the journal until a checkpoint covers it, so the journal replayed at start holds up to 5 minutes of records (before, up to 10 seconds): a start after a power loss can take a little longer. The journal’s and the database’s syncs are unchanged, and no acknowledged record can be lost. Durability
A historian write that hangs, and the repair continued (18 and 19 November, eaxScada a613979e and 85c26b59, builds with the columnar store; safety: historian values operators see, authentication). The spool, its order and the loss accounting are unchanged, and nothing is ever repaired automatically:
- SAFETY: a store write in flight for 30 s now reads down. Each write to the store is timed while it runs: once it has not returned after 30 s,
store_stateisdownwithdown_reasonstalled, andALM-SYS-HISTORIAN-STORE-DOWNis raised, even when the store refused nothing before. It clears when the write returns and the store takes writes. Before, a write that hung before any refusal left the stateokfor as long as it hung.store_down_sinceis the start of that write plus 30 s (or the earlier stall time after a refusal). The store’s state - The repair’s checks run in a separate process of the eaxScada program, which the server starts itself for each file (the patched copy, then the snapshot), read only, each for at most 6 hours. A crash, a hang, an error exit or a missing answer refuses the repair (
refused, with the reason); the server keeps running. The check - Copies left by a restart during a check are deleted at start:
scada_history.repair-<UTC time>.duckdband its.wal, in the store’s folder only, each deletion logged as a warning. The kept originals (scada_history.torn-*) and every other file stay. Do not keep a copy of your own under that name pattern in the historian folder. - The start log says at once whether a store that does not open may be repairable: a warning “historian store at start: may be repairable (a checkpoint cut short)” naming the routes
POST /api/historian/store/repair/check,/repair/signand/repair, or an information line that it is not repairable and only the set-aside is offered. Before, the hint named a System Health button that does not exist yet. - SAFETY (authentication): the repair is signed under its own decision
historian_store_repair, andGET /api/historian/storenames it in the new memberrepair_decision(decisionstays the set-aside’s). A set-aside ticket never repairs, a repair ticket never sets aside, and a repair ticket issued under the set-aside’s decision is refused. Historian store API
Linux and Docker packages (19 November, workspace bd11aef9 and eaxScada 85c26b59):
- eaxScada gets 120 s to stop before it is killed:
TimeoutStopSec=120sin the systemd unit of the Linux archive and of the appliance image (was 30 s),stop_grace_period: 120son every eaxScada service of the release’s Compose files (was Docker’s 10 s). The configurations of the Linux archive, of the full-build Docker image and of the HA sample sethistorian.store.memory_limit: 1GB(without it the store may take up to 80% of the RAM). A stop closes the stores, which checkpoints them; a kill during a checkpoint can leave a store file that does not open. An upgrade replaces the unit but keeps yourconfig.yaml: addhistorian.store.memory_limityourself, and givedocker runor your own Compose file the same stop time. A stop can now take up to 2 minutes. Stopping without cutting a checkpoint short
UDTs (18 November, eaxScada 0c8e02e7 and b821e78d, every edition; safety: engineering data):
- A UDT member’s default is typed and checked against its type:
Booltakestrueorfalse(or0/1from older files),Stringa text (or a number from older files),Int32a whole number in its range,Float64a number. A default that does not suit its type is answered400, naming the member, and nothing is saved. Before, any non-number default was refused, so a UDT with a Bool or String member could not be saved. Older UDT files load and save unchanged. UDT definitions - A UDT keeps its
created_atfrom its first save, whatever a save sends (the Studio used to send the time of each save), and getsupdated_at, the time of the last save (absent from older files until they are saved again). In the Studio, a save keeps members’ descriptions and deadbands and every value you did not edit. - SAFETY: deleting a UDT deletes it on the server. Delete asks first, then sends
DELETE /api/dev/udts?id=<id>(the engineer role, as for a save; recorded in the audit trail first) and reads the list again. Before, the UDT was removed from the Studio’s list only and came back on reload. The server refuses with409while a component template is built on the UDT (it names the templates), answers404for an unknown id and500when the delete could not be written (before,404for every failure). Tags already made from the UDT stay.
Batch records (18 November, eaxScada 0c8e02e7; safety: 21 CFR Part 11):
- SAFETY: the EBR no longer claims integrity.
GET /api/batches/{id}/ebrno longer hasintegrity_valid(it was alwaystrue, with no check behind it); it hasintegrity{"status": "not_checked", "reason": "..."}. The Studio’s badge reads Integrity not verified. No integrity check of batch records exists today: batch records carry no hash chain and no signature over their contents. An integration that readintegrity_validmust readintegrity.statusand must not treat a batch record as verified. The batch record’s integrity
The Studio’s language and dashboards (18 November, eaxScada 1b647bef, 1b2f12f5, b821e78d and c6f65a59, every edition). No command, write, deploy or e-signature logic changed:
- More of the Studio follows the Studio language: the Drivers workspace (a language change re-draws it and keeps what you typed), the PLC hardware wizard, the 3D kit, palette and materials, the isometric blocks and their shortcuts in Help, the 2D Assets tab, the inspector’s States section and the undo history’s step names. A new connection’s default station name is built from the station word: “Knoten 5” in German (it was “Knoten-ID 5”); in English it is the same as before, and a name you type still wins. The dashboard’s edit mode is Edit Layout in the toolbar, the help and the docs (the toolbar said “Edit Matrix”). The Studio’s language
- Dashboard card texts follow the operator’s runtime language in the operator view, and the Studio language in the dashboard editor; they switch when the language changes. Only the words change: what a command writes, the disabled states and the mode codes are the same in every language. Manage dashboards
Memory caps of the database stores (19 November, eaxScada 7cae73da, builds with the columnar store; safety: historian, audit trail, every store whose values operators see). No write-ahead log, sync or checkpoint setting changed:
- SAFETY: every DuckDB store has a memory cap, also without a configured one. A configured value always wins. Without one: the historian 25% of the machine’s memory, at least 512 MiB, at most 4 GiB (1 GiB when the memory cannot be read; on Linux a lower container limit counts); genealogy 1 GiB (
duckdb_memory_limitindata/genealogy/settings.json); alarms, the log console and OEE and downtime 512 MiB (production.duckdb.memory_limit); the audit trail, genealogy states, recipes, security, eaxCollab archive and shift log index 256 MiB. Before, a store without a cap could take up to 80% of the RAM, each its own share. A server whoseconfig.yamlhas nohistorian.store.memory_limit(the Windows package’s, or an older file) now runs the historian under its default. Memory caps of the stores - SAFETY: a store without a threads setting uses one thread per 64 MiB of its cap, at most every core. With a cap and a thread on every core, DuckDB 2.0 failed large statements and the checkpoint after them. OEE and downtime keeps its 512 MiB but now runs 8 threads, not every core; the historian’s
historian.store.threadsand every configured thread count still win. - SAFETY: past its cap a store spills to disk, to a folder named after its file plus
.tmp, next to it: leave room for it on that disk. An encrypted store’s spill files are now encrypted and next to its file; before, they went unencrypted to a.tmpfolder in the server’s working directory. - The start log has one
DuckDB store memory capline per store, with its cap (memory_limit), its threads and where each came from (configordefault), and the machine’s memory. - Limit: a single sort over about 5 to 10 times a small store’s cap can still fail with “Out of Memory”. It fails cleanly: the statement is refused and the store stays usable. Raise that store’s cap if a query of yours needs it.
Dashboard commands and plural counts (19 November, eaxScada ebc02739, every edition; safety: commands). The commands’ decisions, steps, payloads, reasons and signed meanings are identical in every language:
- SAFETY (commands): a dashboard command card’s interlock reasons, confirmation and e-signature dialogs and success messages follow the operator’s runtime language. The signed meaning and the audit reason stay English, exactly as the server records them; the e-signature dialog shows the signed meaning verbatim under a translated Meaning label. When a card is interlocked or disabled does not depend on the language. Manage dashboards
- Every grid count and warning chip uses the language’s singular and plural forms in the five languages, in the Studio and the operator runtime (“1 alarm”, “1 Zeile: …”, French “0 alarme”); before, some read “1 alarms”, “1 checkpoints” or “1 rows: …”. The Studio’s language
eaxCollab (19 November, workspace 5526e173):
- New server flag
-digest-lang en|fr|de|it|es(defaulten): the Daily digest’s card and text are written in that language (headings, sentences, plurals, durations, dates, amounts). English is unchanged. An unknown value refuses the start. The inbox’s language picker does not change the digest: set the flag to the recipient’s language. The Daily digest’s language - Refused agent requests are now logged: one line
sequencer: ingress refusedwith the event, actor, action, object and reason, never the body (rate and duplicate refusals at debug level). Before, a refusal was audited but not logged, so a request refused by the policy (an approval expiry over its action’s maximum, for example) vanished from the log. Refused requests are logged
Batch records (19 November, eaxScada 6a3f2bd5; safety: commands to equipment, batch records, 21 CFR Part 11):
- SAFETY: a batch action is answered only once its record is written. Batch creation, START, RESUME, RESTART, RESET and a prompt acknowledgement whose state or log entry cannot be written are refused with
503and"code": "BATCH_NOT_WRITTEN","status": "refused": nothing changed, no setpoint written. Before, the write errors were dropped and the action was answered OK with nothing on disk. An integration must treatrefusedas “nothing changed, retry once the store writes”. The answers of batch actions - SAFETY: PAUSE, HOLD, STOP and ABORT always take effect. When their record cannot be written they answer
503 BATCH_NOT_WRITTENwith"status": "applied": the command is in effect, its record is kept in memory and written again until it is on disk. Read thestatus: anappliedcommand must not be sent again as if it had failed. A phase step whose record cannot be written puts the batch on HOLD ("status": "held"when an operator action caused it): no further setpoint is written until a RESTART. - A prompt acknowledgement on a PAUSED or HELD batch is refused with
409and"code": "BATCH_NOT_RUNNING": nothing is acknowledged, the batch is not stepped and the prompt still waits. Before, it stepped a held batch into its next phase. RESUME or RESTART the batch first. - New system alarm
ALM-SYS-BATCH-RECORD(“Batch record not written - batch held or record waiting”, High; conditionBatchRecordNotWrittenineaxscada_system_condition) while a batch’s state or log entry is kept in memory but not written. Alert on it. System alarmALM-SYS-BATCH-RECORD - SAFETY: a batch runs the recipe version it was created from. Editing the master recipe no longer changes a batch already created or running; the batch keeps a copy (
recipe_snapshot,recipe_revision). The EBR shows the recipe as run:GET /api/batches/{id}/ebrhasrecipe_source(as_run, orcurrent_not_recordedfor a batch created before this version, withrecipe_note“Recipe as of now (the version run was not recorded).”) andrecipe_revision. Before, the EBR always showed the master recipe as it is now. A batch created before this version still runs, and shows, the master recipe as it is now. A batch runs the recipe it was created from - The batch log is in order: START, then ENTER. A START is logged before its first phase’s ENTER, as the command comes before its setpoints. A report or integration that read the first log entry as the phase entry must read it by
state_transition. In the Studio, the answers above read “Not done: the batch record could not be written; nothing changed”, “Done, but the batch record could not be written yet; it is written again”, “The batch was held: its record could not be written” and “Resume or restart the batch first”, in the Studio language, never as a success.
Batch record integrity (19 November, eaxScada 72fda8db; safety: commands to equipment, batch records, audit trail, e-signatures, 21 CFR Part 11):
-
SAFETY: batch records are checked against their own hash chain and the audit trail. Each batch record is a chain of entries (the batch as created with the recipe as run, state changes, phase log entries, material records, signatures), each SHA-256 hash covering the one before it, and each entry’s hash is written to the audit trail when the entry is written. Every
GET /api/batches/{id}/ebrruns the check.integrity.statusis nowvalid,invalid,partial,not_covered,not_anchoredornot_checked, with a newreason_code.integrity.first_failingis now an object (seq,kind,at,reason,reason_code,field,expected,actual,audit_record,row). New fields:entries,checked_at,covered_from,signatures,late_entries,pending_entries,tip_seq,tip_hash. An integration must treat onlyvalidas verified. In Free and in builds without the audit trail, the best status isnot_anchored, nevervalid. The check -
SAFETY: a step whose integrity record cannot be written is refused. The order of every batch step is: the audit record, then the chain entry (synced), then the views, then the answer. A phase writes its setpoints only after its entry is on disk. A step whose chain entry cannot be written answers
503"code": "EBR_NOT_WRITTEN", withstatusrefused(nothing changed),applied(a PAUSE, HOLD, STOP or ABORT took effect, its entry written again until it is) orheld(the batch is on HOLD, no setpoint until a RESTART). While an entry of a batch waits, every forward step and every signature of that batch is refused, and ALM-SYS-BATCH-RECORD is also active for it. When the record cannot be written -
SAFETY: with the audit trail down, a running batch is held at its next step. The runner’s phase entries, phase completions and wait notes are now recorded first (
BATCH_EBR_ENTRY, user SYSTEM). When that record cannot be written, the batch is put on HOLD before any setpoint is written. Before, these steps had no audit record and the batch ran on. Stops are never blocked: PAUSE, HOLD, STOP and ABORT take effect, and their record is kept in memory and written again every 2 seconds. When the audit trail is down -
New audit records for batches:
BATCH_EBR_ENTRY,BATCH_EBR_COVERAGE_START,BATCH_EBR_VIEW_COMPLETED,BATCH_EBR_VERIFY_ALLandBATCH_EBR_VERIFY_ALL_DONE. The release signature (BATCH_EBR_SIGN_RELEASE) and the new post-release note (BATCH_EBR_POST_RELEASE_NOTE) carry the signing digest insignature. Every batch step’s record names its chain entry inversion_ref(ebr/<batch id>/<seq>/<entry hash>).BATCH_COMPLETED,BATCH_HELD_RUNTIME_STOPPEDandBATCH_HELD_NOT_WRITTENare written before the chain entry. Every refusal of a signature or of a change to a released record is recorded as<action>_REFUSED, with its code. The audit trail gets one index on the resource. Its format is unchanged. -
SAFETY (§11.70): release signatures are bound to the record’s content. A signature signs the batch, the chain entry it signs and that entry’s hash, together with the signer, role, meaning, reason and time. A signature copied to another batch, or a record changed after it was signed, fails the check. Breaking for integrations:
POST /api/batches/{id}/signmust sendkind(releaseorpost_release_note), plussigns_seqandsigns_hashfrom the EBR’s newsigningobject. Without them it answers400 EBR_SIGNS_REQUIRED. It is refused with409EBR_CHANGED(the record moved on,tip_seqandtip_hashin the answer),EBR_INVALID(first_failing),EBR_NOT_CHECKED,EBR_RELEASED,BATCH_NOT_ENDED,EBR_NOT_RELEASEDorSIGN_KIND. Nothing is signed then. Signatures bound to the record -
SAFETY: the release closes the record. A batch is released once it has ended (COMPLETED, STOPPED or ABORTED), and only once. After the release, every command on it is refused (
409 EBR_RELEASED), and only a signed post-release note can be added. Before, a batch could be signed while it ran, and signed again. Record content after the release fails the check (after_release). The release closes the record -
SAFETY: batch records from earlier versions are never reported as verified. A batch without a chain is
not_covered(“Recorded before eaxScada <version>”), for good once it has finished: there is no re-seal. An unfinished batch, or one that takes a forward step, gets aCOVERAGE_STARTentry with its content as found, and ispartialfrom then on. A legacy signature covers the signer, role, reason and time, not the content: it never counts towardvalid, and a record that holds one is at bestpartial(legacy_signatures). Batch records from earlier versions -
SAFETY: recipe approvals are bound to the recipe’s revision and content. Breaking for integrations:
POST /api/recipes/{id}/approvemust send therevisionthe dialog showed. Without it, it answers400 RECIPE_REVISION_REQUIRED. When the recipe changed since, it answers409 RECIPE_CHANGED(current_rev).GET /api/recipescarriesapproval_checksandapproval_meaning. An approved recipe whose approval does not hold for its content launches no batch and downloads no setpoint (409 RECIPE_APPROVAL_INVALID, recorded asBATCH_CREATED_REFUSEDorRECIPE_DOWNLOAD_REFUSED). The Studio reads Approval does not hold and disables Launch and Download Setpoints. Recipes approved only with legacy signatures run as before. Recipe approvals bound to content and revision -
New: check every batch record (Administrators only):
POST /api/batches/verifystarts the check in the background (202;409 VERIFY_RUNNINGwhile one runs; recorded first,503 AUDIT_NOT_WRITTENwithout the record), andGET /api/batches/verifyreturns the last result, with the batches that are notvalidand the batches the audit trail records as created but that are missing from the store. The Studio has no button for it yet. Check every batch record -
SAFETY (Studio): the EBR shows the server’s check and signs the record on screen.
- The badge reads the status and its reason in the Studio language, and the failing entry is marked in its grid row.
- The signatures grid has Covers and Meaning columns.
- The sign dialog shows the record it signs (“Batch <id>, record as of entry <seq> (<time>), <hash>”) and its meaning, word for word.
- The dialog signs the batch whose record is shown, never the active batch. Before, it could sign the active batch while another batch’s record was on screen.
- The sign button is disabled with the server’s refusal, and reads Add post-release note once the record is released.
- The CSV export starts with the integrity block, and the exports carry each signature’s kind, meaning,
signs_seq,signs_hashand Covers.
-
Known limits of the check:
- It does not protect against someone who can rewrite the batch files, the audit trail and the security store together.
- A late audit record of a stop is kept in memory only: a server stop while the audit trail is down leaves the record’s tail
not_in_ledger. - A stop whose entry cannot be written, followed by a server stop before it is written, shows
missing_entry. - The batch list has no integrity column yet.
- On redundant pairs, see the limits in 581.
Batch records on redundant pairs (19 November, Enterprise, eaxScada 89a84bf6; safety: commands to equipment, batch records, HA, 21 CFR Part 11):
- SAFETY: batch record entries replicate synchronously. The primary is the only node that writes batch records. Each step’s chain entries go on the cluster stream
EAX_HA_EBR, and the step is answered only once the cluster has acknowledged them. A forward step or a signature that the cluster does not acknowledge is refused with503 EBR_NOT_WRITTEN"status": "refused": nothing changes, no setpoint is written, and aREVERTEDentry undoes it in the chain. PAUSE, HOLD, STOP and ABORT still take effect ("status": "applied") and their entries are sent late; until the cluster takes them, the batch takes no forward step and no signature. Redundant pairs - SAFETY: a node that is not the primary refuses every batch step with
409"code": "EBR_NOT_PRIMARY": creation, START, RESUME, RESTART, RESET, prompt acknowledgements, signatures, and PAUSE, HOLD, STOP and ABORT too. Nothing changes and the refusal is recorded in the audit trail. An integration must send batch commands to the primary. - SAFETY: the standby accepts only entries that link to its own chain and rebuilds the batch, its phase log and its signatures from that chain; it never saves a batch as received. An entry that does not link stops that batch’s replication on that node, reported in the HA status (
EAX_HA_EBRunderbucketsinGET /api/ha/statusand System Health). - SAFETY: after a failover, the new primary catches up before forward steps. It applies every entry up to its own term marker on the stream first; until then a forward step answers
409 EBR_NOT_PRIMARYand the runner does not step a batch. Entries recorded on one node and never replicated are reported in the EBR asbehind_ledger, “recorded in the audit trail on node <node> and missing here”, never invented. - Phase logs and signatures survive a failover. Before, the standby received only the batch’s state (bucket
ha_batch_state), without its phase log, signatures or chain. That bucket is no longer created or used; on an upgraded cluster it is left as it was. Upgrade both SCADA nodes together: a node of an earlier build neither sends nor applies batch record entries. Batch records on a redundant pair - Known limits on redundant pairs:
- A STOP on a primary that has not caught up can fork the batch’s record on that node; that batch’s replication stops there and is reported.
- The audit trail replicates separately: an EBR opened before the step’s audit record has arrived shows
not_in_ledgerfor that entry for a short time. - Batches that ended before the upgrade are reported missing (
behind_ledger) after a failover, because their entries were never sent to the other node.
eaxCollab inbox language per member (20 November, workspace 2b9c19bd and its follow-ups; security: service permissions):
- The inbox language is kept per member on the server. New
GET /api/prefsandPOST /api/prefs {"lang":"fr"}(""clears): the signed-in member’s own language, in the new bucketchat_prefs; a request cannot name a member (400 bad_request), and a value other thanen,fr,de,it,esor empty is refused (400 bad_lang). The session object has a new field"lang". The inbox applies the account’s language at every sign-in, in any browser, over the browser’s own choice. Where the choice is kept - A language picked on the sign-in page is saved to the account only when it has none yet. A saved language is never overwritten from the sign-in page; an unreadable store saves nothing. The sign-in page never replaces your saved language
- The Daily digest is written in its recipient’s language.
-digest-langis now the language for a recipient without one, and the fallback when the stored languages cannot be read (logged). Why the audit chain was not checked (“the archive did not answer”, “no stream access”, “the verification did not finish in time”, “the verification could not run”) is now translated; it was English inside a translated sentence. English is unchanged. The Daily digest’s language - SAFETY (permissions): the gateway identity reads and writes
chat_prefs, the digest identity reads it, and no other identity holds it. The digest identity may now answer adigest.runwithin 4 minutes (one reply per request, as before) instead of 30 seconds: the digest waits up to 2 minutes for the archive before it answers, soeaxcollabctl digest runsent while no archive was running got no answer. Every other identity keeps its permissions. The server refuses a digest startup grace over 2 min 32 s. Run the digest now - Upgrade step: eaxcollab-server refuses to start with the gateway and digest identities of an earlier version. Run
eaxcollabctl --data <dir> service reissue s-gateway(or your gateway’s id) andeaxcollabctl --data <dir> service reissue s-digest, keeping their keys, then start the server.chat_prefsis created at the start. Upgrade an existing server - The gateway’s identity grows: the most humans one gateway can speak for drops by about two.
Batch record integrity in the batch list (20 November, eaxScada merge scada-ebrlist; safety: batch records, historian and database values operators see, 21 CFR Part 11):
- SAFETY: every check of a batch record is cached with a stamp of what it checked, and a cached status is never served for a record that changed since. A changed record reads
not_checkedwithchanged_since_check; a batch not checked since the server started readsnever_checked. Only a check that covers the record as it is now readsvalid. The cache is in memory and starts empty after a restart. Batches that have not ended are checked at start, and the status is refreshed after every step. The status of every batch GET /api/batchesgains integrity fields per batch (additive, no check runs for the list):integrity_status,integrity_checked_at,integrity_reason_code,integrity_reason,integrity_stale,integrity_entries,integrity_failing_seq. The Studio asks for 200 batches (was 50).- SAFETY:
GET /api/batches/{id}/ebrcaps its check at 2 s. A longer check answers with the last check of the record as it is (integrity.cached: true) or withnot_checked,check_runningandstale: true, nevervalid. Signing is then refused (EBR_NOT_CHECKED) until the check completes; a signature still runs its own full check. The 2 s cap GET /api/batches/verifygainstotaland countscheckedas it goes; each failing row gainsreason_code,entriesandchecked_at. The result stays in memory and in the audit trail (BATCH_EBR_VERIFY_ALL_DONE): after a restartGETanswers 404 until a check runs again. Check every batch record- Studio: a batch list with an Integrity column, and a Verify all batch records dialog (administrators). The list is a data grid with filters, sorting and CSV export; every state other than Verified is marked in its row with its reason. The dialog shows its progress, then its findings. In the Studio
- Recipes carry
approval_invalid(withapproval_invalid_code,approval_invalid_index,approval_invalid_reason_code,approval_invalid_reason) onGET /api/recipesand the recipe answers, from the check that refuses a run or download. It is never stored: a save ignores it. The recipe list in the Studio is now a data grid and marks such a recipe in its row. Recipe approvals bound to content and revision - Known limit: an audit-trail edit with no batch step leaves the list showing the last result until the next check. Opening the record, signing it or Verify all always runs the full check.
The historian finds a refused point by halving the batch (20 November, every edition with the columnar store; safety: historian values operators see). The same points are written in the same order, the same points are quarantined, and none is written twice (a refused half is one transaction). The rules are unchanged: a point is quarantined once a later point is written, and 4 refused alone in a row reads as down (refuses_every_point):
- The search for a point the store refuses halves the batch instead of writing one point at a time. A point 1,200 deep in a batch of 2,000 is found in about 12 writes instead of about 1,200, so
ALM-SYS-HISTORIAN-ISOLATINGclears within one 2 s tick instead of a minute or more. A bad point near the front of a batch costs a few more writes than before. One drain run no longer stops at a refusal (500 writes and 250 ms per drain are unchanged), and one spool head write is taken per run. The store’s state - The store state is
okas soon as the refused batch is past. Before, it stayedisolatinguntil the next store write, and readdownafter 30 s if no new point came. - The status gains
isolation.search_to(the last seq of the part known to hold the refused point).isolation.at_seqis now the last seq settled, not the point being written. A client that readat_seqas the point being written reads a different number.
eaxCollab refused requests answered to the agent (20 November, workspace f5f82f35 and ws-collab203; security: permissions unchanged):
- A refused agent request is answered to that agent. The sequencer publishes a refusal notice on
rpc.<agent>.refused(core NATS, not stored, headerEax-Rpc: refusal, body{"v":"eaxcollab.refusal.v1","id","code","action","ts"}, the code only, never the reason, which stays in the audit record). Duplicates and human requests get no notice. Before, the agent waited until its deadline. Refused requests are answered to the agent - The agent SDK’s
AwaitandCallreturn at once with a*client.RefusedError(errors.Is(err, client.ErrRefused);Codeis the stable audit event, for exampleEC_INGRESS_REFUSED_ACL,EC_APR_REFUSED_POLICY,EC_RPC_REFUSED_MATRIX). Before,Awaitwaited for its context andCallreturnedErrDeadline.Callalso works with a context that has no deadline: it is bounded by the call’s own deadline; before it failed with “nats: context requires a deadline”. No identity needs a reissue. POST /api/prefs {"lang":"fr","if_unset":true}stores the language only when the member holds no choice and answers{"lang":<held>,"set":<stored>};if_unsetneeds a language. The sign-in card uses it, so a choice saved from another browser at the same moment is no longer overwritten. The sign-in page never replaces your saved language- Known limit: administrator native clients still wait for their deadline on a refusal. The log line
sequencer: refusal notice not deliveredmeans the refusal is audited and only the agent’s notice was lost; the request is not retried.
Batch steps confirmed by another SCADA node on redundant pairs (20 November, eaxScada merge 9e2947ed and scada-haanchor, Enterprise; safety: batch records, HA, 21 CFR Part 11):
- SAFETY: a batch step is acknowledged only once another running SCADA node holds its audit record. Before the step’s chain entries go on
EAX_HA_EBR, the primary asks onha.sync.audit.have; the standby takes what it lacks from the primary and confirms. Not confirmed within 4 s, a forward step is refused (503 EBR_NOT_WRITTEN,REVERTED, as for a stream refusal), and a step toward rest applies and is sent again until it is confirmed. If no other SCADA node runs, steps go on as before. Redundant pairs - SAFETY: after a failover, every acknowledged entry is anchored on the new primary and reads
validonce it has caught up. Before, it could staynot_anchoreduntil the old primary came back, or forever if it never did. Steps can take up to about 1.5 s longer when the standby lags. - SAFETY: a running but unhealthy standby blocks forward batch steps (for example one whose audit trail is down). This is deliberate: record integrity comes before availability. Repair the standby or stop it, then send the step again. When a forward step is refused because of the standby
- New system alarm
ALM-SYS-HA-AUDIT-UNCONFIRMED(medium). When another SCADA node was seen running in the last 65 s but no node answers the confirmation (a node of an earlier build, for example), the step still goes on as on a lone primary; the primary logs a warning with its counters and raises the alarm until a step is confirmed or it is no longer the primary. A standby stopped on purpose less than 65 s before a step can raise it too. - Known limits: a step taken while no other SCADA node was running is anchored on a later primary only once the old primary’s records reach it (this replaces the short
not_in_ledgerwindow of 581). With more than two SCADA nodes the first node to answer confirms, so a newly elected node may lack the anchors until it fetches them from the node that holds them.
Late batch audit records on disk, and the batch store in the server backup (20 November, eaxScada merge 11635ffd and scada-latenotes; safety: batch records, backup, 21 CFR Part 11):
- SAFETY: when the audit trail is down, a batch step’s audit record, or the
BATCH_EBR_ENTRYnaming its entry, is saved to disk before the step answers. It is written once the trail is back, also across a server restart. Before, a restart lost it, and the batch record readinvalid(not_in_ledger) forever. The journal is the filedata/recipes/batches/b<id>.lateaudit.jsonl, present only while records are pending. At start, pending records are written at once. A record already in the audit trail (same action andversion_ref) is never written twice. - SAFETY: while audit records are pending, the batch’s integrity reads
not_checkedwith reasonaudit_records_pendingand a new fieldaudit_records_pending. It is nevervalid. Before, it could readvalidwhile a_FAILEDrecord was still pending. - SAFETY: the server backup now holds the batch store: the batch records, their phase logs, the
*.chain.jsonlrecord chains and the*.lateaudit.jsonljournals. Before, none of them was in a backup, so a restore on a new machine had no batch chains. The batch store is copied with its lock held, so no chain line is cut. A backup is refused (BACKUP_FAILED) when it cannot be copied. A restore replaces the batch store with the backup’s (the current one is copied todata/restore-before-<time>/first); the dry run and the summary name the batch files. A backup made by an earlier release has no batch store, and a restore from it leaves the current one as it is. - Upgrade notes: make a new server backup after the upgrade, because earlier backups do not hold the batch chains. Do not delete
*.lateaudit.jsonlfiles indata/recipes/batches; back them up with the chain files. - Known limits: the late audit journal is per node and is not handed to a new primary on failover. Chain entries held in memory when
CommitEBRfails are still memory-only across a restart. A restore writes the batch files only, not the recipe store’s database file.
The master recipes in the server backup (20 November, eaxScada scada-recipebak, Pro and Enterprise; safety: batch records, recipes, backup, 21 CFR Part 11):
- SAFETY: the server backup now holds the master recipes with their approvals (
data/recipes/scada_recipes.json). Before, a backup held the batch store but not the recipes, so a restore kept the target’s own recipes, or none, and the restored batch records named recipe approvals the server no longer had. The recipes and the batch store are copied at one moment, before the audit trail’s copy. A recipe file that cannot be read fails the backup (BACKUP_FAILED); a recipes entry changed or taken away after the backup was written is refused. What a server backup holds - A restore replaces the master recipes with the backup’s, after copying the current file to
data/restore-before-<time>/recipes/; the dry run and the summary name them (“master recipes: N, with their approvals”). A backup made by an earlier release has no recipes, and a restore from it leaves the current ones as they are. Restored with the audit trail and the batch store, every batch record readsvalidand every approved recipe’s approval holds. - SAFETY: at start,
scada_recipes.jsonis the master recipes. Before, each start replaced them with the rows of the recipe database (scada_recipes.duckdb), which are written after a save returns: after a crash with rows still queued, or after a restore, a recipe could come back in an older state, with an approval lost or an approval of its older content back. Now the file wins and the database’s recipe rows are rebuilt from it. With no file, or a file that does not read, the rows are read as before. - Upgrade notes: make a new server backup after the upgrade, because earlier backups do not hold the master recipes.
Interlock tag paths, quoted paths in expressions, and Repair in System Health (20 November, eaxScada scada-ilquote and scada-uibugs; safety: commands to equipment, interlocks):
- SAFETY: a tag path used as an interlock is quoted and escaped, on the screen and on the server. This covers a button’s Bind-tab Disabled interlock tag, a Faceplate interlock tag and a dashboard card interlock tag. A quote, a backslash or a line break in the path no longer breaks the interlock or changes its meaning. Enforce interlocks on the server
- SAFETY: the server now enforces these interlocks. Before, they were screen-only and direct API writes passed. Hand-written escaped paths such as
tag('Area/O\'Brien') == 1are enforced too. - SAFETY: an interlock built from a path the server cannot evaluate (a backtick, braces or brackets, for example
[default]Line/Tag) now refuses the command (409 interlocked, “cannot be evaluated … fail closed”). Before, it let every write through. Under If the interlock reads a Bad value: Allow (stop, trip, emergency) it never blocks, and each such command is logged once as a warning. The Problems panel lint names the fault in both cases. On the screen, an expression that does not parse behaves like a Bad value and logs a warning once per object. The decision is unchanged for every plain path, and the thresholds are unchanged. Limit: a path with an unresolved{...}parameter keeps the earlier rule. - SAFETY: a tag path picked into a binding, a condition or a display text is quoted and escaped, so it can no longer break the expression or run as code.
- System Health has a Repair… action for the historian store (administrators): it checks a copy, then offers the e-signed repair (signer read-only, nothing pre-filled) and shows the result; when no repair is possible it is disabled with the server’s reason. Historian
- Smaller fixes: the matrix fallback error, a rename no longer saves escaped names, toasts show names exactly once, translations, and the “Trends” wording.
- Upgrade notes: commands whose interlock path has backticks or brackets are now refused unless they use Allow. Check the lint in the Problems panel before upgrading.
Kept chain entries across a restart, and late audit records on redundant pairs (20 November, eaxScada scada-halate; Pro and Enterprise, redundant pairs Enterprise; safety: batch records, HA, 21 CFR Part 11):
- SAFETY: chain entries that could not be written are kept on disk. A PAUSE, HOLD, STOP or ABORT whose chain entries cannot be appended still takes effect; its entries are now saved to
data/recipes/batches/b<id>.chainpending.jsonl, synced, before the step answers. After a restart they are written, marked late, and the record checksvalid. Before, they were in memory only, and a restart made the record readinvalid(missing_entry). A journal that does not follow the chain is left in place, logged, and never applied. Known limits - SAFETY: on a redundant pair, the primary’s late audit records reach the other nodes on
EAX_HA_EBR(subjectebr.late.<batch key>). A standby holds them, and its batch readsnot_checked(audit_records_pending) until they are written. After a failover the new primary writes them once, after it has caught up, and the batch readsvalidthere instead ofnot_anchored. Late audit records on a redundant pair - SAFETY: only the caught-up primary, or a server without HA, writes kept late records, and every node drops a kept record its audit trail already holds. A kept
BATCH_EBR_ENTRYis also dropped when the trail holds a later batch record, not a refusal, naming the same or a later entry (the step’s own record was committed, its answer lost). - A node that has run in a cluster waits up to 60 s at start for its replication before it writes kept records. Kept records the cluster does not take are sent again after 10 s; the primary waits on the cluster for them at most once per 10 s.
- Known limit (accepted): if the old primary writes a late record and fails before that record reaches any other node, the new primary writes it too. The audit trail then holds two identical records from two nodes; the batch still checks
valid, and only one step took place. - Upgrade notes: upgrade both SCADA nodes together; a node of an earlier build neither sends nor holds kept records. Do not delete
*.chainpending.jsonlor*.lateaudit.jsonlfiles indata/recipes/batches.
Small fixes, and chain-pending journals in the server backup (20 November, eaxScada scada-small4; the backup item is safety: batch records, backup):
- The Studio cross-reference finds a tag path written after a quoted string holding an escaped quote (
\'or\") or the other quote character. Before, such a tag reference was missed. - 3D designer toasts show names and messages as typed (no
&or'), never as markup. - The historian store toasts in the Studio (set aside, repair, CSV history import) are titled Historian store instead of Checkpoints, in all five languages.
- SAFETY: the server backup holds the
*.chainpending.jsonljournals with the batch store, and a restore puts them back with it. Before, a restore lost chain entries still waiting to be written. Make a new server backup after the upgrade. Restore a server backup
Interlocks with a parameter, evaluated per value or fail closed (20 November, eaxScada merge 119aefbc; safety: commands to equipment, interlocks):
- SAFETY: an interlock with a
{Name}parameter is now evaluated by the server for a value in no parameter set (a tag in the allowed folders but in no set, or a component instance that leaves a parameter undefined). The server reads the parameters from the tag path being written and fills them in: a write toPlant/P107/Startby a START on{Pump}/StartchecksPlant/P107/Trip. Before, such an interlock was never evaluated on the server and the command let every value through, past other objects’ interlocks on the same tag too. Interlocks with a parameter - SAFETY: filled in but the tag does not exist: the write is refused (
409 interlocked), as for a Bad value, unless If the interlock reads a Bad value is Allow. - SAFETY: an interlock with a
{...}the command’s tag path cannot fill in fails closed: every write of the command is refused. With Allow it never blocks and is logged once as a warning. A dashboard card whose Interlock tag has a brace is refused too (a card takes no parameters). Before, both let every write through. The values are filled in before the path is quoted; an expression interlock is filled in only with plain tag path values, otherwise it stays screen only. A path with more than one split into values is checked for each split, and fails closed past 64. - The Studio badge next to the interlock reads Enforced by the server (per parameter value) or Refused by the server (fail closed). New lint rules in the Problems panel:
interlock-parameter(warning) andinterlock-per-parameter(info). - Upgrade notes: before upgrading, list the affected objects with the read-only tool
ilparam-audit [-dashboards <folder>] [-json] <studio data folder>(exit status 0 none, 1 objects listed, 2 error), or check the Problems panel forinterlock-parameter. Each object listed as fail closed refuses every write after the upgrade. List the affected objects before upgrading
HA lease renewal between lease stream elections (20 November, eaxScada merge b4faddea, Enterprise; safety: HA, commands to equipment):
- SAFETY: a primary whose lease renewal is held up by a lease stream leader election now retries every 250 ms or less with the default lease. Each attempt is bounded by one twelfth of the lease TTL, at most 500 ms (it was one sixth, at most 1 s). A timed-out attempt is retried at once instead of after a backoff, so the primary renews in the short writable spells between elections instead of demoting needlessly. How the primary keeps its lease
- HA safety is unchanged: a primary that cannot renew still demotes at its lease expiry minus one sixth of the TTL (500 ms before expiry with the defaults), always before any other node can take the lease. A conflict still demotes at once.
Studio fixes (20 November, eaxScada merge 5df6fbee):
- The Studio cross-reference rewrites
{a/b}and[a/b]tag paths only outside string literals, as the runtime does. Before, a text such as'Mode [A/B]'was rewritten and broke the expression, so its real tag paths were found only by the fallback scan. - The historian store toasts are titled per action: Set aside, Repair and History import, in all five languages.
Screen-only interlocks no longer open a server interlock (20 November, eaxScada merge 9b768ccf; safety: commands to equipment, interlocks):
- SAFETY: an object whose interlock only the screen evaluates no longer counts as not blocked. When several objects send the same value to a tag and another object’s server interlock is active, the write is now refused (
409 interlocked). The message says why: “A command whose interlock only the screen evaluates does not count: the server cannot tell whether it is disabled”. The same for an object with a clear server interlock and a screen-only one. Alone, such an object still lets the value through. Before, it let the value past the other object’s interlock. Keep it a simple comparison - SAFETY: a parameterised screen’s exact target with a
{Name}interlock is decided by the parameter sets the server derives. An expression interlock with{Name}on the screen as designed (screen only) no longer lets writes past the sets’ interlocks. A path interlock with{Name}already failed closed. A pattern value the server keeps screen only no longer opens another object’s interlock. An expression whose{Name}can never be filled in stays screen only; the Problems panel warns about it. Interlocks with a parameter - The Studio interlock badges in the button dialog (Disabled Condition) and in Security & Touch (Disable Condition) are judged with the tags the object writes, as the server judges them. A
{Pump}interlock on a{Pump}/Startcommand shows Enforced by the server (per parameter value). - Unchanged: commands with no interlock, clear server interlocks, If the interlock reads a Bad value: Allow, and commands of screens above the writer’s Required Access Level. Upgrade notes: check the Problems panel for
interlock-client-onlyon tags that more than one object commands; make such an interlock a simple comparison, or compute it into one tag.
A warning before a licence ends (20 November, eaxScada merge cbdbc012, Starter, Pro and Enterprise):
- A licence with an end date now raises
ALM-SYS-LICENCE-EXPIRINGfrom 30 days before it ends: low at 30 days, medium at 14, high at 7 and critical on the last day. Once it has ended,ALM-SYS-LICENCE-EXPIRED(critical) says the server runs as the Free edition (60-minute sessions). A renewed licence clears both. Perpetual licences, and the support and security dates, raise nothing. When a licence has an end date - System Health has a Licence card (edition, licence, end date and days left), the licence dialog shows the days left, and administrators see a status bar chip from 14 days before the end.
GET /api/system/infoandGET /api/system/healthreportexpires_at,days_leftandexpiry_state. - Upgrade notes: on a server whose licence has an end date 30 days or fewer away, the first start of this release raises the alarm at once. Install the renewed licence to clear it.
Web content objects keep values in the browser (21 November, eaxScada merges 56c5e73b and 87282c4c, every edition; safety: values leaving the browser):
- SAFETY: the web content frame’s content policy is strict. Images load only when embedded in the HTML (
data:,blob:), fonts only asdata:; video and audio sources are blocked; requests, frames, forms, workers and plugins stay blocked. Before, an image or media address could name any server, so the HTML’s script could send any value it saw there. Upgrade notes: web content that loaded images, fonts, video, audio or scripts from another server, or images from this server by address, no longer shows them: embed them asdata:URLs. The studio’s own stylesheet classes still work. Images and fonts - SAFETY: a web content frame that opens another address is stopped (a script setting
location, a meta refresh, a link): values stop at unload, then it is blanked and shows “This web content tried to open another address and was stopped” until the screen is opened again. The first request of that navigation has already left the browser. Before the HTML’s script runs, WebRTC connections are refused and resource-hint links are removed (a hint a script inserts still connects). Web content still cannot write tags or send commands. The frame
Dashboards: panel cards, format version 2 and a safe query (21 November, eaxScada merges 8b3b2276 and 0f994bd3; every edition gets every card; safety: commands, values operators see):
- Panel cards (new card kinds) share a dashboard time range, refresh and variables; existing cards are unchanged. SAFETY: a custom card runs under a strict content policy (no network, no outside address, images and fonts inline only; “Blocked: outside address”), and a custom card that navigates itself is stopped (“This card tried to open another address and was stopped”; the first request still leaves). Custom card
- Dashboards are saved in format version 2. Older files open unchanged; fields the server used to drop on save are kept; the editor’s mode is never stored. A save from an older editor over a dashboard with version 2 content is refused (
409 schema_newer). The first open after the upgrade gives every dashboard a new revision, so an open editor tab says “changed by someone else” once. Upgrade notes: back up the dashboards before a downgrade. Dashboard format - SAFETY: a dashboard variable never names a command. A save is refused (
400 VARIABLE_IN_COMMAND_FIELD) when a${...}appears in a command card, an interlock tag, a confirmation or a display card’s screen. The write policy is unchanged. Variables never name a command - New save checks: unknown card kinds (unless already stored), 48 cards, 6 custom charts, 8 queries per card, 50 tags per query and 200 per dashboard, no wildcards, 64 KiB of code, 256 KiB of options, colours as theme tokens or
#rrggbb, links to this server only. Save limits - New
POST /api/dashboards/query, a read open to every signed-in role, checked against the viewer’s read rights per sub-query, with quality and the simulated flag. The historian answers multi-tag aggregates, the first and last Good sample per bucket and the last value before a window (older than 24 h shows uncertain); existing historian answers are unchanged.
A right of its own for dashboard card code (21 November, eaxScada merge 91740c89, every edition; safety: authorization):
- SAFETY: adding or changing a custom card’s HTML, CSS or JS, or a custom chart’s script, needs the new right
dashboards.code(family Dashboard code). Lead_Engineer and Administrator hold it by default; no migration. A custom role below the engineer level can no longer save card code, even with an ALLOW (it can save unchanged code and remove code); the AI co-pilot never can. A DENY ondashboards.code,dashboards.*,*,feature:*or a matching prefix refuses the Administrator too. Copying a card with code counts as adding code; the custom chart’s JSON option needs no right. Card code - A refused save answers
403 code_permission_required(DASHBOARD_CODE_PERMISSION) and writes aDASHBOARD_CODE_REFUSEDsecurity audit entry. The DASHBOARD audit records of create, rename, update and duplicate list each code change by its SHA-256 (code_changed). Upgrade notes: card code that a custom role below the engineer level used to edit is now changed by a Lead_Engineer.
Dashboards phase 1: new cards, the card editor and the custom chart (21 November, eaxScada merges 8d26cc9e, 816eec19, 6da790e2, c3ea9ec9, b746668b, 750b3bc4 and e2179353; every edition gets every card; safety: values operators see, code in the viewer’s browser):
- New time cards: Time series and State timeline. A time series draws up to 12 series from history (aggregates with a min/max band), live tags or a dataset: line, smooth, step, area, bars or points, stacked, on two axes with a log scale. A state timeline shows discrete states per tag, opened by the value before the range, with mappings and PackML, production and on / off presets. SAFETY: Bad samples are gaps, and a Bad stretch is hatched “Bad”, never the last state carried on; Uncertain is dashed or hatched; simulated values are marked SIM; legend statistics use Good samples only. An optional zoom moves the dashboard range, with Back. PNG and CSV of the plotted data. Time series
- New value cards: Stat, Gauge and Bar gauge. A value with a sparkline and its change over the range; a dial, arc, ring, zoned, PV/SP/OUT, level bar or bullet gauge; up to 50 bars, sorted. SAFETY: reduced values use Good samples only. A range with other samples is marked UNCERTAIN; no Good sample shows “—” with BAD, never 0; nothing received shows NO DATA; a tag’s current value keeps its own quality. Stat
- New record cards: Table, Alarm list, Bar / pie, Pareto and Text. The table shows tags, history and records in the data grid, live in place; a value without Good quality shows “—” and its row is marked. The alarm list is read only: standing alarms or the journal for the range, filtered by area, priority, class and state, with counts; acknowledge in the alarm views. The Pareto gives stops without a reason their own Unassigned reason bar, always. The text card uses a safe markdown subset with variables and live values: no HTML or script runs, and links go only to this server. Alarm list
- Display thresholds are colours, not alarms, on every new card (“Colours only. Alarms are set in Alarms.”). The new cards are read-only: none writes a tag, acknowledges an alarm or sends a command.
- Add card opens a card picker (Time, Values, Records, Custom, and Classic for the earlier cards); the new cards are also in the palette. The card settings have a live Chart | Values preview and the tabs Query, Display, Thresholds and Overrides. Build a dashboard
- A toolbar with the time range, refresh and variables, in the Studio and in the runtime. The runtime keeps the range and the variables in the page address. A value outside a variable’s choices is refused. Dashboard settings set the default range, refresh, time zone and variables. SAFETY: variables never reach commands, interlocks, confirmations or screens. Time range, refresh and variables
- Convert to new card turns an earlier trend, KPI, sparkline, gauge or alarm summary into a new card: explicit, undoable, and it lists what is not carried over. Nothing is converted automatically. The Studio saves dashboards in format 2; a dashboard saved by a newer Studio asks you to reload; a code change without the Dashboard code right is refused with that reason.
- New: the Custom chart card, in every edition. A script that returns the chart option, or option JSON with placeholders bound to the card’s queries. SAFETY: it is always drawn in an isolated sandbox frame (
/static/chart_sandbox.html, with its own strict policy): no network, cookies, storage or page access; it cannot read or write tags or send commands; its only data are the card’s own query results, read with the viewer’s rights. A script over 3 s is stopped; an option over 2 MB or 200,000 values is refused; links in the option are ignored; at most 6 custom charts draw on a page. Every custom chart shows a CUSTOM mark, and its CSV is built from the query results. Saving a script needsdashboards.code; option JSON only the edit right. Custom chart - Dashboard fixes: panel cards follow the Studio light theme; live values keep their real time, and the CSV of a live card no longer fails; panel titles are shown; a live state timeline keeps the state in force when the range opens; saving always sends the format version, time range and variables; a query can have its own time shift or range. A shifted series is drawn over the current period and named “(shifted …)”, its CSV keeping the recorded times; a time series narrower than 480 px leaves out the legend statistics; the light and ISA-101 grid guides are no longer dark bars.
- Alarm history cards without a row limit work again: they are read page by page up to the card limit (at most 10,000), the alarm visibility applied on every page, and marked TRUNCATED past it. A card header saved without “enabled” stays visible, and a header explicitly hidden stays hidden. Upgrade notes: nothing to do; earlier cards stay as they are until you convert them.
Dashboards: faster aggregates and clearer cards (21 November, eaxScada merges 3455739b, bf3d2b53, 291e746d and 327efee3; every edition; safety: historian values operators see):
- Dashboard aggregates are faster. A card’s aggregated history of many tags is bucketed by the historian in one DuckDB query for all its tags, instead of reading every raw sample of every tag. The buckets and their values are the same as before: Good samples only for average, minimum, maximum, first and last Good, the same counts and quality. An average can differ from the earlier answer in the last digits only, since the same samples are summed in another order. A tag the fast path cannot answer exactly (recent samples still in memory, an older CSV history, a special value) is answered the earlier way.
- Card wording: relative ranges read naturally in every language, with their plural (“Last hour”, “Last 6 hours”, “6 dernières heures”, “Letzter Tag”). In French the Stat card is named Valeur (Italian Valore). The card buttons’ tooltips (drag, settings, template, duplicate, remove, full size), the trend’s “No tag bound to this trend” and the KPI’s “Change since” are translated, with accessible labels.
- Axes and labels fit the card: a time series keeps its y-axis numbers and units after a live update (the unit name starts at the axis line, never cut at the card’s edge). Time labels never overlap or touch at any card width (about one label per 90 px). In a short card the y-axis numbers that would meet are left out. A state timeline’s row names take about a third of a narrow card. A Stat card’s sparkline starts at its first sample when the samples begin after the range start, instead of a thin bar at the card’s edge. Stat
- The CUSTOM mark names who last changed the chart code and when. The server writes the user and the time on each card whose code a save adds or changes (
card.meta.codeChangedBy,card.meta.codeChangedAt); values a client sends for them are never kept, and a card whose code is unchanged keeps the stored ones. The mark follows the Studio light themes. The CUSTOM mark
The AI co-pilot proposes built-in cards, the alarm list filters on the server, and the interlock audit ships (21 November, eaxScada merge 59e7fe43; every edition; safety: authorization, alarms operators see, interlocks):
- SAFETY: the AI co-pilot proposes built-in panel cards, never code.
scada_propose_dashboardnow takes the built-in panel cards with their queries: every one except the Custom chart. A proposal holding a Custom chart, a custom card (accepted until now) or any code field is refused (“the AI co-pilot never proposes card code”). An update to a dashboard that already holds a custom chart or a custom card is refused too: a person with thedashboards.coderight changes it. A person still applies every proposal with an e-signature. Dashboards the assistant may propose - SAFETY: every tag a proposed card shows must be readable by the co-pilot’s account, now including every panel card query and the tag of an alarm query’s filter (before, a panel card’s tags were not checked). A
${variable}in a tag path is checked for each of its choices and its default. A tag path with a variable whose values are not listed (a tag folder, dataset column or shift variable, or an undefined one) is refused, since the tags it reaches cannot be checked. - A dashboard proposal is checked when it is made as a save checks it: limits, queries, links, colours and rule D1 (no variable in a command field; before, only when it was applied). A panel card cannot name a faceplate or a classic card kind.
GET /api/alarms/activetakes the alarm list card’s filters:area(aliaspath, by whole path segments),priority(aliasseverity),class(aliascategory),state(active,unack,shelved,returnedor a display state) andtext(aliasq, every word). Lists are comma-separated or repeated;ALLis no filter. SAFETY: the filters run after the caller’s read rights and the alarm visibility, so they only take rows away. An unknown state matches nothing. The alarm list card shows the same rows from a smaller answer. Standing alarms with filters- New command
eaxscada interlock-audit [--workdir <dir>] [--studio <dir>] [--dashboards <dir>] [--json]in the server binary (alsoeaxscada ilparam-audit): it lists the command objects whose interlock with a{...}fails closed, never blocks (Allow) or stays screen only. Read-only: it writes nothing and can run while the server runs. Exit status0none found,1objects listed,2a usage or read error (also for a folder withoutpages/orcomponents/). List the affected objects before upgrading - Development only: with
EAX_DEV_MODE=1the sign-in page also offers the Compliance Auditor preset (the read-only Auditor role). Without development mode no preset and no development password is sent, as before. - Upgrade notes (what now behaves differently):
- An AI client that proposed custom cards, or changes to a dashboard that holds a custom card or custom chart, is refused: a person with the
dashboards.coderight makes those changes in the Studio. - A co-pilot proposal naming a tag its account may not read in a panel card query, or a variable tag path without listed values, is refused: give the account read rights on the tags, or use a variable with fixed choices. - A client ofGET /api/alarms/activethat sentarea,path,priority,severity,class,category,state,textorqand expected every standing alarm now gets the filtered rows; astatevalue the server does not know returns no rows. - Before you switch the service to this version, run itseaxscada interlock-audit --workdir <project folder>(or on a copy of the project) and fix the objects it lists.
One priority rule for alarms, alarm limits and shifts on dashboard cards, and dataset cards audited once per hour (21 November, eaxScada merges 59e7fe43 (the priority rule), e966c1b7, 7b1a9caf and 202d06a6; alarm limits in every edition, shifts and dataset cards Pro and Enterprise; safety: alarms operators see, authorization, audit trail):
- SAFETY: an alarm priority that is not one of the five is read one way everywhere, and never lower than any surface showed it before.
CRITICAL,HIGH,MEDIUM,LOWandINFOstay as they are; the older namesHIGHESTandURGENTareCRITICAL; any other name (WARNING,WARN,MINOR,NOTICE, an unknown one), an empty or a missing priority isHIGH. The rule is the server’s, and every display follows it: the alarm counts and the counters and annunciators built on them, the alarm class colours and sounds, thepriorityfilter ofGET /api/alarms/active, the alarm list card, the alarm banner and summary objects, the classic dashboard alarm summary, the phone view and the 3D and isometric views. Priority names - What moves:
GET /api/alarms/countsand the class colours and sounds now count and showHIGHESTandURGENTasCRITICAL(they wereHIGH). In the alarm list card and theGET /api/alarms/activefilter,WARNING,WARN, an unknown or empty priority areHIGH(wereMEDIUM),MINORisHIGH(wasLOW) andNOTICEisHIGH(wasINFO). The alarm banner and summary objects no longer hide an alarm with an older or unknown priority from their priority filter, and sort and countHIGHESTandURGENTasCRITICAL. The classic alarm summary shows an unknown priority asHIGH(wasLOW) andINFOasINFO(wasLOW); the phone view shows an unknown or missing priority asHIGH(wasLOW); the 3D and isometric views colour an object by such an alarm asHIGH(it ranked belowINFO). - New: Show alarm limits on the Time series, Stat, Gauge and Bar gauge cards (Thresholds tab; saved as
fields.thresholds.fromAlarms: true). The card shows its tags’ own alarm limits, read-only:HIGH_HIGH,HIGH,LOWandLOW_LOWat their setpoint (HH, H, L, LL), the deviation limits at the setpoint plus or minus the deadband (a negative deadband counts as 0, as the alarm engine reads it),EQUALandNOT_EQUALas a line at the setpoint on the time series only; rate of change and bad quality have no value line. A time series draws them as solid labelled lines (“HH 95”) beside the dashed display thresholds. On a stat, gauge or bar gauge they take the place of the threshold steps for that tag (beyond LL or HH critical, beyond L, H or a deviation limit warning) and are listed in the tooltip; the stat sparkline shows them dotted. Show alarm limits - SAFETY: alarm limits come only from the alarm definitions the viewer may read, from the server, in the card’s own
POST /api/dashboards/queryrequest, never from the dashboard file and never cached. One card tag the viewer may not read and the card shows no limit at all. A card never raises, acknowledges, shelves or hides an alarm; no write path was added. An alarm’s state changes no limit. A failed limits read shows no limit without marking the card failed; a card with 8 queries has no room for them. - New: This shift and Previous shift in the dashboard time picker (Pro and Enterprise), from the
reports.shiftscalendars (calendardefault, else the first), resolved by the same code as the report schedules and the shift log, so the three agree. This shift runs from its start to now and stays live. The toolbar names the range (“This shift: early”); on a phone they are in the Filters range list. Without a shift calendar they are simply not offered. Shift ranges - New: the Shift variable type in Dashboard settings: a shift calendar (empty:
default) and an optional default shift; its choices are the calendar’s shifts, the current one first and marked “(now)”, which is the default when none is set.${shift}is the shift’s name. A save whose shift variable names an invalid calendar name is refused (400 INVALID_VARIABLE). Build a dashboard POST /api/dashboards/queryhas two request-only sources:alarm_limits(the card’s tags; answerstag,kind,value,condition,severity,alarm_id,name) andshifts(filteratin Unix ms, default now, andcalendar; answers the frameswindowsandshifts). Neither can be saved in a card (400 INVALID_QUERY). Reading data- SAFETY (audit trail): dashboard dataset cards read through the new
POST /api/reports/datasets/{id}/view: the preview’s rights (reports_designoranalytics;reports_viewalone is still refused a dataset card), limits, read as the user and answer, but itsrun.previewrecord (purpose: "view",audit_window_s: 3600) is written once per user, dataset, parameters and outcome per hour, withrepeats_since_last_recordcounting the reads in between. Four dataset cards at a 5 s refresh wrote about 450 records an hour per viewer (2,880 when they failed); they now write 4. The explicit preview (POST .../preview, dataset editor and designer) still writes one record per request. A failed dataset card is answered from the cache for 10 s for the same viewer instead of running again at every refresh. Dataset reads for viewing - Upgrade notes (what now behaves differently):
- Alarm counts, counters, annunciators, colours and sounds now show alarms whose priority is
HIGHESTorURGENTasCRITICAL(they wereHIGH):CRITICALtotals can rise andHIGHtotals fall. Alarms with any other priority name, or none, areHIGHon every surface. A client ofGET /api/alarms/counts, or of thepriorityfilter ofGET /api/alarms/active, that relied on the earlier reading gets other counts or rows. To keep a priority as it was, set it to one of the five names in the alarm definition. - Alarm banner and summary objects with a priority filter now also show alarms whose priority is older or unknown, under the priority they are shown as. - The audit trail holds far fewerrun.previewrecords from dashboards: one per user, dataset, parameters and outcome per hour, withpurpose: "view"andrepeats_since_last_record. Audit reports that countedrun.previewrecords as dashboard reads must countrepeats_since_last_recordtoo; explicit previews are still one record each. - A dashboard dataset card that fails shows the same failure for up to 10 s after the cause is fixed.
Dataset cards for report viewers, and links in custom chart tooltips (21 November, eaxScada merges 0f91bbdf and 07fdc55b; dataset cards Pro and Enterprise, the custom chart every edition; safety: authorization, audit trail):
- SAFETY (authorization): users with the right to view reports (
reports_view) now see the dataset cards on dashboards. The rows are read with the viewer’s tag read rights, as a report run or a dataset export reads them. Each view is recorded in the audit trail once per hour per user, dataset, parameters and outcome. The AI co-pilot can’t read datasets this way, whatever its rights. The dataset preview still needsreports_designoranalytics. Dataset reads for viewing - Fix: a custom chart tooltip that contains a link now shows the link’s text, without the link. Before, the tooltip showed nothing. The chart still can’t add a link. Custom chart
- Upgrade notes (what now behaves differently):
- A user with
reports_viewbut withoutreports_designoranalyticsnow sees the rows of dashboard dataset cards, where the card was refused before, and their views appear in the audit trail. To keep a user from these rows, remove theirreports_viewright.
Alarm limits always in view, short trend cards, Safari fields, System Health alarm counts and command help (21 November, eaxScada merges 07fdc55b, 03243ce8, 9f1b9fa0, e543e60e and 07a64f6d; every edition; safety: alarms operators see):
- SAFETY: alarm limit lines are always in view on a time series card. An auto axis widens to the outermost limit. A fixed axis is kept, and a limit beyond it is named at its edge, “↑ HH 9.5 off scale” or “↓ LL 1.5 off scale”, in the colour of the most severe limit. Before, a limit outside the plotted values was not drawn. Show alarm limits
- SAFETY: the stat sparkline keeps its alarm limits in view. Near limits widen its range, while the values keep at least a third of its height. Far limits show the off-scale marker. Show alarm limits
- SAFETY: a gauge marks a limit beyond its scale. The gauge keeps its scale and its value. An off-scale mark appears at the end of the arc or bar, with a tooltip that names the limits. Before, such a limit was not shown. Show alarm limits
- SAFETY: close limits share one label. Two limit lines closer than a label’s height share one label, for example “H 23.4 · L 22.9”. Before, one label was written over the other. Show alarm limits
- SAFETY: limit lines are drawn at their exact value, never rounded. Before, a limit of 1.0011 was drawn at 1.00. Show alarm limits
- Fix: short trend cards show about one value label per 40 px, and labels never stack. A 200 px card shows 3 labels instead of 7. Time series
- Fix: dark and light controls are readable in Safari. The page’s colour scheme now follows the theme, so lists and date fields match it. Time range, refresh and variables
- Fix: in a browser without a date and time field, the absolute range is a text field “yyyy-mm-dd hh:mm”. The date is shown in words below it, and an impossible date such as 30 February is refused. Time range, refresh and variables
- SAFETY: the System Health alarm counts include every priority name.
System/Health/<node>/Alarms/Active,UnackedandShelved, and theeaxscada_alarmsmetric, read the priority as/api/alarms/countsdoes:URGENTandHIGHESTasCRITICAL, any other name asHIGH. Before, an alarm with a non-standard priority name was missing from these counts.Alarms/Activeis every alarm not inNORMAL, shelved included, counted for the whole server. System Health history - Command help: each command prints one description line under its usage:
backup,restore,historian-backup,historian-restore,historian-migrate-csv,audit-set-aside,cloud enrol,cloud status,cloud disconnect, andeaxlicence keygen,sign,verifyandinspect. Command line - SAFETY: every chart and gauge mark line is drawn at its exact value, display threshold lines included. None is rounded to 2 decimals any more. This covers the display thresholds of the time series card, the bullet gauge’s target line, the limit lines of the level bar, bullet and sparkline gauges, and the Pareto reference line. Before, a threshold of 1.0013 was drawn at 1.00. (eaxScada merge 07a64f6d.) Show alarm limits
- SAFETY: the bar gauge marks a limit beyond a bar’s range. An off-scale triangle appears at that end of the bar, with the tooltip “↑ HH 30.0 off scale”. Bars, values and scales are unchanged. Before, such a limit was not shown at all. (eaxScada merge 07a64f6d.) Show alarm limits
- Upgrade notes (what now behaves differently):
-
System/Health/<node>/Alarms/ActiveandAlarms/Unackedcan read higher than before, when alarms use priority names other than the five. A trend or a rule built on them sees the jump at the upgrade. - A time series card with Show alarm limits and no fixed min or max can show a wider axis than before.
The server’s node id in eaxTags scripts, and alarm counts in the Process plant template (21 November, eaxScada merge 71539d92; every edition):
- New: eaxTags scripts read the server’s node id as the global
node. It is read only, and it is the<node>of the server’s ownSystem/Health/<node>/...tags:ha.node_id(or--node-id) when set, elsenode-scada-<NATS port>. A script reads its own server’s health with"System/Health/" + node + "/PLC/line1/Online", which works on every server, where a fixed node name read nothing on the others. The script help and the code editor’s completion list it. The node global nodecannot be changed. An assignment is ignored, and throws in a"use strict"script. A script that declaresnodeat top level is refused when you save it, with its line: “line N: node is the server’s node id, read only: declare another name”. A localnodeinside a function is allowed. Scripts pinned to an eaxPLC runtime have nonode. The node global- A stored script that already declares
nodekeeps running after the upgrade, with its ownnodeand without the server’s global. The server logs one WARN for it, and the script’s status shows awarning(in amber in the Studio) until the variable is renamed. The node global - Fix: the Process plant starter template’s header shows alarm counter tiles, Active and Unack, from the alarm engine. They count the plant’s alarms as the alarm banner does, and a click lists the standing alarms. Before, the tiles were texts bound to two local tags that nothing wrote, so they read “0 active” for good. Those two tags are no longer in the template; a plant that applied it earlier keeps its copies until it applies the template again or deletes them.
- Upgrade notes (what now behaves differently):
- A stored eaxTags script that declares its own top-level
noderuns as before, with a WARN in the log and a warning in its status. Its next save is refused until the variable is renamed. - A script that assigns tonodewithout declaring it no longer sets its own value:nodekeeps the server’s node id, and a"use strict"script throws at the assignment.
Starter templates without made-up readings, templates on editions without 3D, and the node id of the offline commands (21 November, eaxScada merges 3a0d589f, e7433fc8 and 9da99c3c; every edition):
- SAFETY: starter templates bring no made-up readings. Every measured value of a starter template shows no value, “waiting for initial data”, until a script, a driver or an operator writes it. Alarms hold on a waiting value and raise no quality alarm. Before, these tags started Good at invented values: a freshly applied Process plant raised four alarms, one of them HIGH on a fake 92 % tank level. This covers all twelve templates, 558 tags. Local tags with no initial value
- Two setpoints keep their defaults. The bottling line speed (
FL03/SpeedSetpoint, 32000 bph) and the pharma temperature setpoint (TIC501/Setpoint, 36.8 °C) are writable and start at their default values, as before. - New: the local tag option
no_initial. In an eaxTags definition,"no_initial": truemeans the tag has no value until something writes it. Its initial value must be 0; a definition with another initial value is refused. At every start the tag is Bad, “waiting for initial data”, with timestamp 0. A script’stags.setmakes it Good, and a writable tag gets back its operator value as before. Tags without the option are unchanged. Local tags with no initial value - SAFETY: the Studio’s eaxTags editor keeps
no_initialon every save. The editor has the checkbox “No value until written”. While it is ticked, the initial value is 0 and cannot be edited. The tag API keeps the option when a save leaves it out; only"no_initial": falseclears it. Before, a save from the editor cleared the option, and the tag read a Good 0 from the next start. The tags grid shows a waiting tag as a muted dash, never 0, and a new Quality column can be filtered and exported. (eaxScada merge 9da99c3c.) Local tags with no initial value - Starter template tags are no longer marked simulated. The 509 template tags that carried the mark lose it: no “(simulated)” text and no SIM badge. Nothing in a template simulates them. Plants that applied a template earlier keep their tags unchanged. (eaxScada merge 9da99c3c.)
- Starter templates on an edition without 3D design (Free, Starter) skip their 3D pages and the links to them. The apply reports each 3D page as skipped with the reason. The 2D pages lose their 3D navigation button and the overview’s 3D card. Before, the apply reported the 3D pages as failed and still added links to the missing page. Pro and Enterprise apply every page.
- The offline commands name the server with the server’s own node id rule.
backup,historian-backup,historian-migrate-csvandgenealogyread the same configuration files as the server (--config, elseconfig/config.yaml,config.yaml,eaxscada.yaml,.eaxscada.yaml, with the same environment overrides). They useha.node_id, elsenode-scada-<NATS port>. Before, a server configured by./config.yamlor./eaxscada.yamlwas namednode-scada-4222in its backups and exports. Command line - Upgrade notes (what now behaves differently):
- Existing plants keep their tags unchanged. A template applied before this release keeps its local tags with their initial values, because an apply never overwrites a tag that exists. Only tags added by a new apply have
no_initial. - A fresh template shows its measured values as “waiting for initial data” until a script, a driver or an operator writes them. Plan a script or a driver channel before you show it to operators. - A template applied on Free or Starter and applied again after a Pro licence adds the 3D page; only the pages added by that apply link to it. - A backup or an export of a server configured by./config.yamlor./eaxscada.yamlcan carry another node name than before. The offline commands still take no--node-id.
eaxTags tag actions that fit in every language, and new local tags without made-up values (22 November, eaxScada merge b5c35c42; every edition):
- Fix: the tags grid’s actions fit in every language. The pinned actions column had a fixed width of 290 px, and in German and French its first action was cut off. It is now as wide as its labels in the Studio language. The tag list in the Studio
- New: a narrow tags grid keeps “edit” and a “⋯” button on each row. When the grid is too narrow for its columns and every action (typically at 1366 px), the button (“More actions for path”) opens a menu with comments, where used, history and delete. Delete stays rose and still asks first. Open comments show as a badge on “⋯”. The layout follows the window and column widths. Narrow tables: edit and the More menu
- The More menu works from the keyboard. Enter, Space or a click opens it with the focus on its first item. The arrow keys, Home and End move. Escape, Tab or a click outside closes it and gives the focus back to the button. The edit, history and delete buttons now have accessible names that name the tag. Narrow tables: edit and the More menu
- A new local tag is no longer Simulated by default. The New local tag dialog used to tick Simulated for every new tag. Now a new tag starts with Simulated off, Writable off and No value until written on: a measured value is Bad, “waiting for initial data”, until a script, a driver or an operator writes it. The dialog says so under the options. Defaults of a new tag
- Ticking “Writable by operators” on a new tag turns “No value until written” off, so a setpoint or mode starts with its initial value. Unticking Writable turns it back on. Once the engineer sets “No value until written” by hand, Writable no longer changes it. Existing tags open with their own flags, and Writable does not change the option for them. Defaults of a new tag
- Docs: new reference pages for eaxTags. eaxTags local tags lists every member of a tag definition (
no_initialincluded, with its rules) and the tag, export, import and history API. eaxTags script reference gives the script lifecycle, what a script reads and writes, every global and function, and the errors the Studio shows. - Upgrade notes (what now behaves differently): - A tag created in the Studio after the upgrade is not Simulated unless you tick it, and it shows no value until something writes it unless you tick Writable or untick No value until written. A tag created through the API or an import is unchanged: the members it sends decide. - Tags that exist keep their flags.
Hand an eaxTag over to a driver, and back (22 November, eaxScada merge 7f40b628; every edition; safety: tag ownership, values operators see):
- SAFETY: a mapping on an eaxTag’s path is still refused, now with an offer.
POST /api/dev/drivers/tagon a path an eaxTag produces answers409 OWNED_BY_LOCAL_TAGwith the local definition and the handover’s plan: what would move, and what blocks it. Before, it answered500“tag is owned by another producer”. The Studio’s Map New Tag dialog shows the refusal with a Hand over to driver button, proposed first for a starter template’s measured value. Connect a device to an eaxTag - New: Hand over to driver (
POST /api/dev/drivers/tag/handover, engineer or above). After a second confirmation that lists what moves, the server moves the path from the eaxTag to the mapping in one step: never two writers. It carries the unit, the engineering range, the write range, the e-signature for external writers and the description, keeps the local definition in the mapping’s newhanded_overrecord, and shows the tag Bad, waiting for initial data, until the driver’s first good read. Alarms keep the same path. 2. Hand over to driver - SAFETY: writability is carried, never widened. An eaxTag operators cannot write (every measured value of a template) becomes a Read only mapping; a mapping that asks for Read/Write or Write only on it is refused (
writable_differs). A writable eaxTag becomes Read/Write; an explicit Read only is refused (read_only). Writability is carried, never widened - A handover is refused, with nothing changed, when an enabled eaxTags script writes the path (
script_writes), the mapping is a String mapping (text_mapping), or its unit, engineering range or write range differs from the eaxTag’s (unit_differs,range_differs,write_range_differs). The answer is409 HANDOVER_REFUSEDwith the plan. What blocks a handover - New: Return to local tag (
POST /api/dev/drivers/tag/return?id=, the Return action on a handed-over mapping’s row, which asks first). The local definition from the handover record takes the path back in one step and the mapping is removed. 3. Give the path back - Both actions are audited first and run on site only.
EAXTAG_HANDED_OVERandEAXTAG_RETURNEDgo to the security trail,HANDOVER_TAGandRETURN_TAGto the driver audit trail; without them nothing changes (503 AUDIT_NOT_WRITTEN). They run on the HA primary only, and never through remote access. Audit records - New eaxTags field
placeholder. Every starter template’s measured value carries it (the 558 eaxTags that are not writable and haveno_initial). It changes nothing about who produces the tag. A save that leaves it out keeps it; only"placeholder": falseclears it. Template tags waiting for a device - Upgrade notes (what now behaves differently):
- A client that read the
500refusal of a mapping on an eaxTag’s path now gets409with"code": "OWNED_BY_LOCAL_TAG". Nothing else changes on the refusal. - Deleting a handed-over mapping deletes itshanded_overrecord; the local definition then stays only in the eaxTags store’s history. Use Return to local tag to get the eaxTag back. - The handover writes no annotation into the trends: there is no historian annotation API yet. - Plants that applied a template earlier keep their tags unchanged, withoutplaceholder. Their tags can still be handed over, with the warning shown for an ordinary eaxTag.
Studio top bar (22 November, eaxScada merge 9bd8f3f8; every edition):
- Fix: the Studio top bar never scrolls the page sideways, in any language. At 1366 px in French (and 1280 px in English) the bar could end a few pixels past the window when it refitted itself after a resize, a language switch or a new badge. It now measures each step at its final size. Deploy shows only its icon at the same step in every language and keeps its undeployed-changes count; on a touch tablet it is a 40 px target. A long user or role name ends in an ellipsis, with the full name in its tooltip.
View-only stations, idle time and session maximum per group, and the lockout per account and address (23 November, eaxScada e9bdf408; every edition, Free included; safety: authentication, authorization, values operators see):
Sessions and idle time:
- New: idle time and session maximum per group, with security defaults (Security > Groups, Edit defaults;
GET/PUT /api/auth/session-policy). Idle time 1 to 720 minutes, session maximum 1 to 12 hours. Of several groups the shortest value applies; the defaults apply only when no group sets one. A change applies at once to open sessions, measured from their last input, and is recorded first (SESSION_POLICY_CHANGED). Session limits - New installations sign a person out after 30 minutes without input. An upgraded installation keeps idle time off until it is set. The session maximum stays 12 hours.
- A session ends on the server at its idle deadline, at its maximum, on sign-out or when it is revoked: at the first request past a deadline and, without any request, within 5 seconds. Its live-value socket closes within 3 seconds and its NATS connections are closed. Before, a session lasted 12 hours whatever happened, and NATS connections outlived it.
- Only input and accepted commands count as activity. Real input in the browser (reported by
POST /api/auth/activity, at most every 20 s) and an operator or engineering command the server accepts extend a person’s idle deadline. Reads, polling and live data do not. - New: the countdown. Operator screens and the Studio show Still there? before an idle end, with Stay signed in and Sign out now, timed by the server’s clock, and a notice 5 minutes before the session maximum. At the end every open command dialog closes without sending. In the Studio the countdown warns that unsaved changes in open editors are lost; the open screen’s unsaved edits are kept as a draft in the browser, and the Studio goes to the sign-in page.
- New:
GET /api/auth/sessionanswers the caller’s deadlines (idle_deadline,hard_deadline,server_now,view_only,station). It is not activity. The answer ofPOST /api/auth/logincarries the same deadlines. - NATS clients that sign in with a user name and password get the idle time (on new installations, and on upgraded ones once it is set): broker traffic is not input, so they are disconnected after the idle time. Programs should use an NKey identity.
- Signature tickets are bound to the session that asked for them and are void once it ends.
POST /api/auth/signatureaccepts a session only within its idle and absolute deadlines. - Remote classes of the new routes:
GET /api/auth/session,GET /api/auth/stationandPOST /api/auth/activityare view class; the session policy, the pairing and the station administration are never reached through eaxCloud remote access.
Accounts and the lockout:
- Five wrong passwords from one address lock the account from that address only, for 15 minutes, sign-in and e-signature alike (
ACCOUNT_LOCKED_ADDRESS). The account still signs in from other addresses. - Twenty wrong passwords from all addresses within 15 minutes lock the account everywhere, for 15 minutes (
ACCOUNT_LOCKED). Before, five from anywhere did. - An administrator’s unlock or password reset lifts the per-address locks too.
- Disabling, locking or deleting an account, or changing its roles or groups, signs it out at once and closes its NATS connections. Before, its sessions stopped only at their next request.
- An account cannot change between a person and a viewer identity.
- A viewer identity is created only with a station. Through the users API only its status can change, or it can be deleted; any other change is refused (
400, codeviewer_identity). - A viewer identity is refused every write and administration action, whatever roles, groups or rules it holds, and is never treated as an Administrator.
- An SSO sign-in on a station gets the station’s idle cap, like a password sign-in.
- Object e-signature tickets are void once the signing session ends.
- New Access audit events:
ACCOUNT_LOCKED_ADDRESS,SESSION_POLICY_CHANGED,SESSION_IDLE_END,SESSION_MAX_END,VIEWER_CREATED,VIEWONLY_START,VIEWONLY_SIGNIN,VIEWONLY_RETURN,VIEWONLY_REFUSED,PAIRING_FAILED, andSTATION_CREATED,STATION_CHANGED,STATION_DISABLED,STATION_DELETED,STATION_PAIRING_CODE,STATION_PAIRED.
View-only stations:
- New: view-only stations (Security > Stations,
/api/security/stations). A station is one paired browser, bound to a viewer identity, with its screens (the first is the start screen), optional address ranges that only narrow it, an idle cap, Show alarms (on) and Allow Studio (off). Every change is recorded first. Topic Rights grants read rules to a viewer identity (Grant to: User or viewer), the station’s row opens them with Read rights for, and a row whose viewer identity has no read rule says No read rule. Set up a view-only station - Pairing: a one-time code of 8 characters, valid 10 minutes, entered under Use this screen for viewing only on the sign-in page (
POST /api/auth/station/pair), or Pair this browser for the administrator’s own browser. 5 attempts per address per 10 minutes, the successful ones included (429 pairing_rate_limited); after 50 wrong codes from all addresses, pairing at a screen is closed for the rest of the window. - A paired station browser with nobody signed in gets
/runtimeand read-only views. Before, it was redirected to the sign-in page. - Writes from a station are refused with “sign in to operate”: every request other than a read is
401, never run as the viewer identity. - Screens outside the station’s list are refused (
403), and the runtime goes back to the start screen. - With Show alarms off, a station sees no alarms (
403 viewer_alarms_hidden, and no alarm event on its socket). - A station’s live view closes within 3 seconds when it is disabled, deleted or paired again; a person signed in there is signed out.
- A person signed in on a station has their own rights only, gets the station’s idle cap when it is shorter, and may open the Studio there only when the station allows it (
403 studio_not_on_station). - A permission rule for a viewer identity can only allow reads:
subscribeon a topic orreadon a screen, with Effect ALLOW. Any other rule is refused (400, codeviewer_identity) and recorded (PERMISSION_CHANGE_REFUSED). In the Studio, a station row’s Read rights for button opens the rule dialog with only these choices. 2. Give the viewer identity its read rights - On a view-only station the health indicator shows “Control status is not shown while viewing only” (VIEWING), and no STATUS UNKNOWN banner: a station operates nothing, so this is not a fault.
- Upgrade notes (what now behaves differently): - Nothing changes on idle time until you set it on an upgraded server. Set the default and the group values before you rely on them. - Integrations that sign in to NATS with a user name and password are disconnected after the idle time once it is set. Move them to NKey identities first. - A shared screen where operators often mistype a password now locks them from that screen only. A script that counted on five failures from anywhere locking an account now needs twenty, or five from one address. - A person whose roles or groups an administrator changes is signed out at once and signs in again. - A screen in kiosk mode that is not a station shows the sign-in page after the idle time. Register such screens as stations; Security > Groups shows a note while idle time is on.
Requests from another origin (23 November, eaxScada merge 06c1b2a4; every edition, Free included; safety: authentication, authorization):
- SAFETY: a request that changes something, sent with a cookie from a page of another origin, is refused. A
POST,PUT,PATCHorDELETEauthenticated by the session cookie, the olderscada_tokencookie or a view-only station’s cookie must come from eaxScada’s own origin, or from one inserver.allowed_origins. From another port of the same host, a sibling subdomain, or an opaque or sandboxed origin (Origin: null) it answers403with"code": "cross_origin", and nothing runs. Before, such a page could send commands with the operator’s session. Cookie-authenticated requests from another origin - SAFETY: a sign-in from another origin is refused, even without a cookie.
POST /api/auth/loginandPOST /api/auth/change-default-passwordfrom a page of another origin answer403 cross_origin, so no page can sign a browser in as an account of its choice. server.allowed_originsnow also allows those origins to send requests that change something with the cookie, not only to open/ws. There is one list for both. Other origins- New Access audit event
CROSS_ORIGIN_REFUSED, with the method, the route and the reason, at most once a minute per client address. - Unchanged: clients that send a token in the
Authorizationheader (API tokens, PLC tokens), eaxCloud remote access, the single sign-on callbacks,GET,HEADandOPTIONSrequests, and scripts or tools that send a cookie without a browser’s origin headers. - Upgrade notes (what now behaves differently):
- A page on another origin (another port or subdomain) that sends commands to eaxScada with the operator’s session gets
403 cross_origin. Add its origin toserver.allowed_origins(orEAX_ALLOWED_ORIGINS) if it is meant to. - Behind a reverse proxy that rewritesHost, list the proxy inserver.trusted_proxiesand have it sendX-Forwarded-HostandX-Forwarded-Proto, or every sign-in and command from the public address is refused as another origin (as/wsalready was). - Integrations that sign in with a cookie and also sendOrigin,RefererorSec-Fetch-Siteare checked like a browser. Use an API token in theAuthorizationheader instead.
Text colours and the Studio canvas (23 November, eaxScada merges 39b246d8, f0ae9bd3, 8d9ec1d8; every edition):
- Fix: a text style’s colour shows on a Text whose own colour is the type’s default. The Text’s default fill was painted over the style’s colour, so a style’s colour never showed on a new Text. The order is now the object’s own colour, then its state’s, then the text style’s, then the type’s default, in the Studio and in the operator runtime alike. A colour picked for the Text still wins. How texts, fonts, states and languages are resolved (merge 39b246d8)
- Fix: the on-screen keypad’s outlines are visible. The outlines of the keys, buttons, entry field and panel have at least 3:1 contrast in the dark, light and ISA-101 themes. (merge 39b246d8)
- The inspector’s Text colour swatch shows the colour the canvas draws. While the Text takes its colour from its text style, the swatch shows that colour with the note From text style and the style’s name. Format text on a screen (merge f0ae9bd3)
- Fix: the Studio canvas shows the screen’s own background in the light theme, as operators see it; before, the light theme’s surface hid it. ISA-101 shows it converted to its greys, as it shows the screen’s shapes. The grid and the area outside the screen follow the colour drawn, so a dark screen keeps a readable grid in the light theme. (merge 8d9ec1d8)
- Upgrade notes (what now behaves differently):
- Text objects that kept the default colour and use a text style (or a family whose normal state names one) with a colour now draw in the style’s colour. Pick a colour on the Text to keep the old look.
- A Text whose colour was set by hand to exactly the type’s default (
#38bdf8) counts as the default and takes the style’s colour too.
Security-store ids (23 November, eaxScada merge ee22f98e; every edition; safety: authorization, audit trail):
- SAFETY fix: a permission rule saved right after another one no longer replaces it. Users, roles, groups, permission rules and audit records created without an id now get an id with a random suffix. Before, on Windows, rules, groups or roles saved in quick succession without an id could get the same id, and the later one overwrote the earlier: a permission rule, possibly a DENY, was lost without a message. This was seen with the memory and file security stores.
- Fix: two audit records can no longer get the same id. On the DuckDB store a duplicate audit id would have failed the audit write, and the action it recorded would have been refused. This was not reproduced on test hardware.
- Upgrade notes (what now behaves differently): - Existing ids are unchanged. Only new records get the new form of id. - On Windows, if rules, groups or roles were created in quick succession (by a script or an import) with the memory or file store, check that each one is still listed under Security, and create again any that is missing.
The Studio canvas surface (23 November, eaxScada merge 2502317a and eaxScada 8876e34b; every edition):
- Fix: the pressure transmitter’s reading follows the surface it is drawn on, in the Studio and in the operator runtime: light on a dark screen, dark on a light one. Before, it took its colour from the page theme, so a dark screen in the light theme drew a dark reading on a dark background (about 1.1:1). (merge 2502317a)
- Fix: screens opened by find and replace, by a history restore and by distribution show their own background. Before, they kept the background of the screen open before. (merge 2502317a)
- Fix: saving Screen settings with a new background redraws the screen at once, so the readings drawn on it follow the new background straight away instead of at the next opening. Unsaved changes, zoom, pan and the selection are kept. (eaxScada 8876e34b)
Broker connections follow a change of rights (23 November, eaxScada merge 2b304fff; every edition, the audit records in Starter, Pro and Enterprise; safety: authorization, audit trail):
- SAFETY fix: a change of rights closes the open NATS connections it affects, at once. Changing a topic rule, a role, a group or a group’s roles closes the open NATS connections of every user whose broker rights change. Before, such a connection kept the subjects it was given when it connected for as long as it stayed open; only a change of the account itself (its roles, groups, status or deletion) closed it. A change that leaves a user’s rights the same closes nothing. Broker connections (eaxScada 2b304fff)
- SAFETY: changes made another way take effect within 2 seconds: an SSO sign-in that changes the account’s groups, or another HA node. A backup restore runs only with the server stopped, so every connection is authorized again at the next start. (eaxScada 2b304fff)
- SAFETY: if a user’s rights cannot be read, their NATS connections close and new ones are refused (fail-closed), the Administrator’s included. (eaxScada 2b304fff)
- The client connects again with its current rights; its session is not ended. Device, watcher and the server’s own connections are never closed this way. (eaxScada 2b304fff)
- SAFETY: each close is recorded as
NATS_CONNECTION_CLOSED, with the reason (for example “the user’s rights changed (rule X deleted by admin)”) and now the client address. (eaxScada 2b304fff) - SAFETY:
NATS_AUTH_REJECTEDis recorded at most once a minute per client name and address (the port is ignored), with the number of rejections not recorded since. At most 8 names per address get their own record, and at most 1024 entries in all; beyond that, they share one entry. Every rejection is still refused and written to the server log. (eaxScada 2b304fff) - Upgrade notes (what now behaves differently):
- A NATS client of a user whose rule, role or group an administrator changes is disconnected and connects again. A client that does not reconnect by itself must be restarted.
- A client that retries a refused connection in a loop now leaves one
NATS_AUTH_REJECTEDrecord a minute instead of one per attempt. Read the count in the record, or the server log, for every attempt.
View-only stations on an HA cluster (23 November, eaxScada merge df57e95a; every edition, HA clusters only; safety: authorization):
- SAFETY: view-only stations are replicated across an HA cluster. A station paired, changed, disabled or deleted on one node is the same on every node, so paired screens keep working after a failover. Before, a station was known only on the node where it was paired: after a failover its screen showed the sign-in page and had to be paired again. A single node is unchanged. On an HA cluster (eaxScada df57e95a)
- SAFETY: a disable or a delete applies on every node. The station’s screen stops on every node within moments, and its sessions there end. (eaxScada df57e95a)
- SAFETY: a station change the cluster does not confirm is refused with
503 store_unavailable, nothing changed: also while the node is not yet synchronized with the cluster or has lost its change feed. (eaxScada df57e95a) - SAFETY: fail closed until synchronized. A node uses no station credential until it holds the cluster’s stations: a few seconds after it starts, or while its change feed is lost. During that time wall screens show the sign-in page, and
VIEWONLY_REFUSEDsays “stations not synchronized with the HA cluster”. (eaxScada df57e95a) - SAFETY: a station is bound to each node’s own viewer identity of the same username. Viewer identities are each node’s own, like users. A node without one of the viewer kind refuses the station (
VIEWONLY_REFUSED, “viewer identity missing, disabled or not of the viewer kind”). To create it on that node, see 796. (eaxScada df57e95a) - SAFETY: each change a node applies from the cluster is recorded as
STATION_REPLICATED, with what changed and the node it came from. (eaxScada df57e95a) - Pairing codes stay on their node. A code is redeemed only on the node that issued it; the pairing it makes is replicated. The time and address a station was last seen are each node’s own. Sign-in lockouts were still each node’s own in this release; they are shared by the nodes since eaxScada 528843ae (823). (eaxScada df57e95a)
- Upgrade notes (what now behaves differently):
- On an HA cluster, create every viewer identity on every node, with the same username, before you rely on a failover. A node without it refuses the station.
- Create a viewer identity missing on a node with
POST /api/security/stations/viewerson that node (796). On a node without the station’s viewer identity, station changes, new pairing codes and pair-here are refused with409 viewer_unusable(795). - The first time each node runs this build, it adds the stations it already had to the cluster’s copy. After that the cluster’s copy is the reference: a station deleted while a node was stopped does not come back from that node. Check Security > Stations after the upgrade and delete any station you no longer want. - For a few seconds after a node starts, its wall screens show the sign-in page, then return to viewing only. - Station changes are refused while the cluster cannot confirm them. Try again once the cluster answers.
View-only station changes need the viewer identity on the node (23 November, eaxScada merge ca8c23dc; every edition, the refusal on HA clusters only; safety: authorization):
- SAFETY fix: on an HA cluster, a station change on a node without the station’s viewer identity is refused. Changing a station, asking for a new pairing code or a pair-here on a node where the station has no usable viewer identity (missing, disabled or not of the viewer kind) is answered
409 viewer_unusable: “the station’s viewer identity is not usable on this node: create the viewer identity <name> on this node, or make the change on a node where the station works”. Nothing changes on any node. Before (since df57e95a), such a change gave the cluster a station without a viewer, and its screen showed the sign-in page on every node. A change that picks a viewer identity this node has is allowed. On an HA cluster (eaxScada ca8c23dc) - SAFETY: a viewer identity can be created without a station:
POST /api/security/stations/viewerswith{"name": "lobby"}, by a security administrator, same origin, JSON body, never through eaxCloud remote access. It has no password and no role and never signs in;VIEWER_CREATEDis recorded first. The answer is201withviewer,"created": trueandrebound, or200with"created": falsewhen it exists already; a person’s account of that name is refused with409 viewer_unusable. Station routes (eaxScada ca8c23dc) - SAFETY: on an HA node, the new viewer identity takes effect at once. The stations whose cluster copy names that username, and that have no viewer identity on the node, are bound to it straight away, listed in
reboundand each recorded asSTATION_REPLICATED. (eaxScada ca8c23dc) - Upgrade notes (what now behaves differently):
- On an HA cluster, a station change made on a node that lacks the station’s viewer identity is now refused with
409 viewer_unusableinstead of being saved. Create the viewer identity on that node, or make the change on a node where the station works. - A script that creates viewer identities on each node callsPOST /api/security/stations/viewers; creating a station is no longer the only way to get one.
The session token leaves Web Storage, and the sign-in page redirects only within the site (23 November, eaxScada merge 2dafaefa; every edition, Free included; safety: authentication):
- SAFETY: browsers keep no session token in Web Storage. The sign-in page, the runtime’s in-place sign-in and the Studio no longer keep
scada_tokeninlocalStorageorsessionStorage. The session is the HttpOnlyscada_sessioncookie only, as on a view-only station already, so a script injected into a page cannot read it. Browser pages send noAuthorization: Bearerheader. Requests that change something with the cookie must come from eaxScada’s own origin, as before. Where the browser keeps the session (eaxScada 3ea52386) - SAFETY: a token an older version left in Web Storage is removed when a page loads and at every sign-in.
scada_user(the account’s public fields, no secret) stays inlocalStoragefor the user badge. The sign-in lifetime is unchanged: the cookie ends with the server session. (eaxScada 3ea52386) - SAFETY fix: after the sign-in page, only a path of this site is followed. The
redirectparameter of/loginmust start with one/, not//or/\, contain no backslash or control character, and resolve to this origin; anything else goes to/. Before, the sign-in page fallback could follow a link such as/login?redirect=/\other.exampleto another site (an open redirect). (eaxScada 3ea52386) - Unchanged: API tokens, MCP clients, eaxPLC and eaxCloud remote access still send
Authorization: Bearer. Sign-out still ends the session on the server and clears the storage. - Upgrade notes (what now behaves differently):
- A custom script or bookmarklet that read
localStorage.scada_tokenfinds no token there any more. Give it an API token and send it in theAuthorizationheader. - Aredirectlink to another site, or one starting with//or/\, now lands on/after the sign-in.
Create a viewer identity from the Studio, and the screen follows a new user at once (23 November, eaxScada merges 93fdd00a and c2000a4f; every edition, the viewer identity refusal on HA clusters only; safety: authorization):
- New: Create viewer identity in Security > Stations. An administrator selects Create viewer identity in the toolbar (in the More menu when the window is narrow) and enters one name: 1 to 64 characters, no spaces or slashes. It calls
POST /api/security/stations/viewersand creates only a viewer identity: no station, no password, no role, and it never signs in. The stations of this node that name it are bound to it at once. A new viewer identity has no read rule: give it read rights. A name that belongs to a person’s account is refused: pick another name. On an HA cluster (eaxScada cf2e6b4d) - The station dialog explains a
409 viewer_unusablerefusal. When a station change on an HA node is refused because the node lacks the station’s viewer identity, the dialog says so in plain words and offers Create viewer identity with the name filled in. Once it is created, the station dialog selects it: save again. A person’s account of that name, or a single server’s missing or disabled viewer identity, is explained without that button. (eaxScada cf2e6b4d) - SAFETY: the
409 viewer_unusableanswer names the viewer identity to create. On an HA node, when the name is known, the answer carriesviewer_name, for a station change, a new pairing code, a pair-here and a screen pairing with a code. There is noviewer_namefor a person’s account of that name, for a single server’s missing or disabled viewer identity, or for an unknown name. The messages, the status codes and what is refused are unchanged. Station routes (eaxScada 744c4d7f) - SAFETY: when the signed-in user changes on a runtime screen, role-gated elements follow the new user at once. After an in-place sign-in, a sign-out, or a return to viewing only on a station, every element that depends on a role stays hidden or disabled until the new user is read: an unknown user is denied. Before, the previous user’s roles applied until the new user was read. When a session ends (eaxScada 392d7a2a)
- The live connection opens again at once when the user changes, in about 0.1 to 0.2 seconds instead of about 1 second, with the new user’s rights. The previous values show as stale until the new values arrive. (eaxScada 392d7a2a)
- Internal: at shutdown the server waits up to 5 seconds for the last-seen writes of the stations, and at start it removes the stale
stations.jsontemporary files that an interrupted write left. (eaxScada db44ee7a) - Upgrade notes (what now behaves differently):
- On an HA cluster, create a missing viewer identity in Security > Stations with Create viewer identity;
POST /api/security/stations/viewersstill works. - A client that reads a409 viewer_unusableanswer may readviewer_name. Clients that ignore it are unaffected. - Just after a sign-in or a sign-out on a runtime screen, role-gated buttons and shapes stay hidden or disabled for a moment, until the new user is read.
A value the account may not read shows a lock, and markers no longer stack (23 November, eaxScada merge b486c2ee; safety: operator-visible quality display):
- SAFETY: a value the signed-in account may not read shows a blue lock marker instead of the red ✕, with the tooltip “Not readable for this account”. On a view-only station this is the station’s viewer identity. The object is greyed out exactly as for Bad: the value is never shown as good or as a number, and conditions that use it are not applied. Before, it showed the red ✕, so a missing read right looked like a device fault. A tag the account may not read (eaxScada e6fea919)
- SAFETY: a device fault is never hidden behind a lock. An object shows the lock only when every Bad tag it reads is not readable. The marker order is: Bad from the device, a missing value or an evaluation error (red ✕), then not readable (lock), then Uncertain (amber ?), then stale (dashed outline). One marker per object (eaxScada e6fea919)
- One marker per object, and markers that would overlap merge into one. The merged marker is drawn on the largest object of the group, with the worst state of the group, and its tooltip lists every tag of every object in the group. A small object inside a small bound object, such as a status pill or a badge, merges the same way. Each object keeps its own grey veil. (eaxScada e6fea919)
- The Studio hint on access levels names the Topic Rights workspace. (eaxScada e6fea919)
- Upgrade notes (what now behaves differently): - A screen object whose tags the account may not read shows a blue lock where it showed a red ✕. Tell operators that the lock means a missing read right, not a device fault. - Where several small objects sat close together, operators now see one marker for the group instead of several. Hover it to see every tag.
Gauges show NOT READABLE with a padlock, gauges bound to an expression show the quality of its tags, and markers are redrawn when a tab is shown again (24 November, eaxScada merges e64aeac8, 55b8e981 and 70e77ef6; safety: operator-visible quality display):
- SAFETY: a live gauge whose tag the account may not read shows NOT READABLE with a padlock. When every Bad tag a gauge reads is not readable for the signed-in account, its face shows a dash, a padlock and NOT READABLE on a blue label (NO ACCESS on a narrow gauge), with no number, needle, bar or trend. This covers the gauge object, a dial gauge drawn by the live gauge engine, and the gauge and sparkline tiles of a dashboard grid. Before, the face showed a dash and BAD QUALITY, so a missing read right looked like a device fault. Gauges show quality on their face (eaxScada c4b0f1e7)
- SAFETY: a device fault is never hidden behind the padlock on a gauge. A device Bad on any tag the gauge reads keeps BAD QUALITY. A setpoint, output or target tag the account may not read draws no marker and no number; the face follows the value tag. Uncertain, stale and good values are shown as before. (eaxScada c4b0f1e7)
- SAFETY fix: a gauge bound to an expression shows the quality of the tags the expression reads. When an input goes Bad, the gauge shows a dash and BAD QUALITY and never keeps the last good number. When every Bad input is not readable for the account, it shows NOT READABLE with the padlock. An evaluation error or a result that is not a number gives a dash and BAD QUALITY. Before, a gauge bound to an expression drew every value as good, and kept the last number when the expression gave no number. (eaxScada 85679f74)
- SAFETY: an Uncertain or stale input keeps the value of an expression-bound gauge, dimmed, with its label (UNCERTAIN or NO LINK - STALE), as a gauge that reads the tag itself. (eaxScada 85679f74)
- Gauge cards of the Dashboard workspace have the padlock face too, for a value marked not readable. Today the server refuses a card query that names a tag the account may not read, so such a card shows its empty text, “No samples in this range”, with QUERY FAILED, and no value. That was the case in this release; since eaxScada a3554c2c (833) a refused query shows a dash, the padlock and NOT READABLE on the gauge card. Gauges show quality on their face (eaxScada 85679f74)
- Quality markers are redrawn at once when a hidden browser tab is shown again. While the tab is hidden, the quality changes are recorded; when it is shown again, all markers are sorted out and drawn straight away with the current quality. A frame lost while the tab was hidden no longer stops the passes that come after it. Before, the markers of a tab brought back to the front could stay out of date. A browser tab shown again (eaxScada 86b165a5)
- Upgrade notes (what now behaves differently): - A gauge whose tags the account may not read shows a padlock and NOT READABLE where it showed BAD QUALITY. Tell operators that the padlock means a missing read right, not a device fault. - A gauge bound to an expression now shows BAD QUALITY and a dash when an input is Bad, where it showed the last number as good. It shows UNCERTAIN or NO LINK - STALE, dimmed, when an input is Uncertain or stale. - A gauge bound to an expression no longer keeps its last number when the expression gives no number: it shows a dash. - Unchanged: the alarm engine, interlocks and commands; only what the gauge shows changes.
Sign-in lockouts shared across an HA cluster (24 November, eaxScada merge 528843ae; every edition, HA clusters only; safety: authentication):
- SAFETY: on an HA cluster, wrong passwords are counted across the cluster. Wrong passwords of sign-ins and of electronic signatures count on every node. 5 from one address lock the account from that address on every node; 20 from all addresses together lock the account on every node; both for 15 minutes. Before, each node kept its own counts and locks: an attacker could try more passwords by switching node, and an account locked on one node could still sign in on another. Accounts are matched by username. A single node is unchanged. Lockout parameters (eaxScada 7e6796d3)
- SAFETY: a node refuses a sign-in that the cluster has locked, and shows the lock. It copies the account lock into its own security store, so Security > Users on that node shows the account as locked. (eaxScada 7e6796d3)
- SAFETY: unlocks and correct passwords apply on every node. A correct password clears the count of its own address on every node. An administrator’s Unlock or password reset on one node clears the lock and every count of the account on all nodes. Before, the administrator had to unlock the account on each node where it was locked. An administrative lock is still each node’s own, like the users. (eaxScada 7e6796d3)
- SAFETY: when the shared lockout store does not answer, each node uses its own checks. If the store does not answer within 500 milliseconds, or cannot be used yet (for example while it is not replicated), that attempt uses the node’s own counts and locks, as on a single node. The node records
LOCKOUT_SHARED_UNAVAILABLEat most once a minute, and its HA status shows that sign-in lockouts are per node (GET /api/ha/status,buckets,ha_lockouts). An unreachable store never unlocks anything, and never refuses every sign-in. Sign-in lockouts on an HA cluster (eaxScada 7e6796d3) - SAFETY: when the store answers again, the node merges its counts and locks into it and records
LOCKOUT_SHARED_RESTORED. A lock made while the store did not answer then holds on every node until it expires. (eaxScada 7e6796d3) - SAFETY: the limits while the store does not answer. A node does not know about locks that only other nodes set. An unlock made meanwhile applies on that node only, and is recorded as
LOCKOUT_SHARED_UNAVAILABLE; the other nodes keep the lock until it expires. (eaxScada 7e6796d3) - SAFETY: a new HA bucket,
ha_lockouts, holds one record per account, keyed by a SHA-256 hash of the username, with no password. It is replicated like the other HA buckets, and broker users are denied it. (eaxScada 7e6796d3) - Upgrade notes (what now behaves differently):
- On an HA cluster, an account locked on one node is now refused on every node, and an attacker no longer gets more tries by switching node.
- An administrator’s unlock or password reset on one node now clears the automatic lockout on all nodes. While the shared lockout store does not answer, the unlock applies on that node only, and a lock the store still holds applies there again once it answers: unlock again once the store answers, or wait for the lock to expire.
- Create the same accounts, with the same usernames, on every node: the shared lockout matches accounts by username.
- Keep the node clocks in sync (NTP): an unlock from another node is compared with the time the lock was set.
- Watch for
LOCKOUT_SHARED_UNAVAILABLEin the Access audit: untilLOCKOUT_SHARED_RESTORED, sign-in lockouts are per node. - Unchanged: a single node, the lockout limits (5 per address, 20 per account, 15 minutes), administrative locks, and every other refusal.
Dashboard cards never show a failed query’s previous values, and the gauge card binds its PV, SP and OUT to their own queries (24 November, eaxScada merges 30f132ca and a3554c2c; every edition; safety: operator-visible values):
- SAFETY: the gauge card binds its PV, SP and OUT to their own queries. They are the first three values in the order of the card’s queries and their tags, never in the order the answers arrive. When the PV query fails, the PV shows a dash with BAD QUALITY. When the PV query is refused because the account may not read its tag, the PV shows a dash with NOT READABLE and the padlock, and a device fault on another value still shows BAD QUALITY. The SP is never drawn as the PV. A dial whose only query failed shows a dash with BAD QUALITY instead of the empty “No samples in this range”. Before, the values were taken in the order they came back, so when the PV query failed the SP could be drawn as the PV. A query that failed or was refused (eaxScada 8bd1a347)
- SAFETY: a failed dashboard query never shows its previous values. The runtime keeps the query’s last answer only for its names, tag paths and units, and hands it to every card with no value, every quality Bad and nothing simulated. Text values are removed too: an old state such as RUNNING is never shown or exported as current. Rows of records (alarm rows and counts, OEE and downtime, dataset rows) are left out. Before, a failed query kept its last good values on the card, shown as current. (eaxScada 7dbd0318, 3932c46e)
- SAFETY: a refused query shows NOT READABLE with the padlock. On the stat, bar gauge and gauge cards, each value of a query that names a tag the account may not read shows a dash, a padlock and NOT READABLE on a blue label, also before the query’s first answer. A current-value tag that becomes unreadable for the account while the dashboard is open shows NOT READABLE with the padlock at once, on the gauge and stat cards. Before, a refused query showed the card’s empty text, or its last values. Dashboard cards whose query failed or was refused (eaxScada 7dbd0318)
- SAFETY: the stat and bar gauge cards keep one cell or bar per tag of a failed query, each a dash with BAD and no bar, named from the query’s tags, also before its first answer. A value never moves into the place of another query’s value. (eaxScada 7dbd0318)
- SAFETY: the other cards show a failed query as Bad. The time series draws its samples as Bad, and its legend shows no value. The state timeline draws Bad stretches. The table and the bar / pie card show its values as a dash with Bad and leave its record rows out. The alarm list does not list its alarms, and says “The alarms could not be read.” when nothing is left. The text card shows a dash with BAD for
{{A.last}}. A custom chart gets its frames with every valuenulland every quality Bad. (eaxScada 7dbd0318) - SAFETY: with transformations, a device fault is never hidden behind the padlock. As soon as one query of the card failed, every value is a dash with BAD. The padlock is shown only when every failed query was refused and no other query brought a value that is Bad from the device. (eaxScada 7dbd0318)
- The header chip texts say what is shown. “The last good drawing is kept” is now “Its samples are drawn as Bad until it answers again” on the time series and “Its states are drawn as Bad until it answers again” on the state timeline. On the table and the bar / pie card it is “The failed query shows no values (Bad) until it answers again”, on the alarm list “The alarms of the failed query are not shown until it answers again”. A failed query is still retried every 30 s. New tooltips on the quality markers of the stat card: “The query failed: no value is shown until it answers again” and “This account may not read this tag: no value is shown”. (eaxScada 7dbd0318)
- Upgrade notes (what now behaves differently): - A dashboard card whose query failed shows dashes with BAD where it showed the last values of that query. The values come back with the next answer, at most 30 s later. - A text value of a failed query, such as a machine state, is no longer shown or exported in the card’s CSV. - A card whose query names a tag the account may not read shows NOT READABLE with the padlock on the stat, bar gauge and gauge cards. Tell operators that the padlock means a missing read right, not a device fault. - The bar / pie card no longer keeps its last drawing when its query fails: its categories show a dash with Bad, and its records are not drawn. - The time series, table and alarm list no longer keep their last good drawing, rows or list when a query fails. - A gauge card whose PV query failed shows a dash for the PV; it no longer shows the SP in its place. A dial whose only query failed shows a dash with BAD QUALITY instead of its empty text. - A stat, bar gauge or gauge card whose only query failed now shows QUERY FAILED, not PARTLY FAILED, even when the query had answered before. - Unchanged: the server’s queries and read rights, the alarm engine, interlocks and commands. The cards are still read only.
The System Health HA panel shows every replicated store (24 November, eaxScada merges 4b929d0f and a72af842; Enterprise, HA clusters only):
- The Replication card lists every replicated store the server reports, those not in use first, each under its own name: Sign-in lockouts, View-only stations, Electronic batch records, Active alarms, Signature nonces, Signature tickets, Integration registry, Shift log drafts and Shift handovers. The note under the rows gives the reason of each store not in use. Before, the card showed only the first six stores, so a store not in use could be left out, and some stores were shown by their internal names. HA panel (eaxScada a72af842)
- The configuration store is shown once. While its replicas are fine, they have no row of their own: the card’s Configuration store row stands for them. When they are not, a “Configuration store replicas” row and its reason appear. (eaxScada a72af842)
- When the sign-in lockouts store does not answer, its row reads “per node”. Sign-ins still work: each node uses its own counts and locks until the store answers again. Lockout parameters (eaxScada a72af842)
- The Cluster nodes, domains and backups grids update their rows in place on each refresh. Filters, sort and scroll stay as they are, and the warning markers are drawn again only when a row’s warnings change. Before, every refresh redrew every row. (eaxScada a72af842)
- Upgrade notes (what now behaves differently): - The Replication card can have more rows than before, and stores not in use come first. - Unchanged: replication itself, the sign-in lockouts and the server’s HA status. The panel is still read only.
Result hashes over the rows in any order (24 November, eaxScada merge 82cb5ee5; Pro and Enterprise; safety: report and audit records):
- The result hash of a dataset no longer depends on the order the database returns the rows in. It covers the result’s rows as a set, in any order, plus the columns (names and types), the row count (a duplicate row counts) and whether the result was truncated. The same rows in another order give the same hash; a changed, added or removed row or value, a changed column or a changed truncated flag gives another hash. Before, the rows were hashed in the order read: DuckDB reads in parallel, so a query without
ORDER BY, or with rows that tie on itsORDER BY, could give another hash on unchanged data. Result hash (eaxScada 82cb5ee5) - Analytics queries and queries over extracts use the same rule for the
sha256of their result and of theiranalytics.queryaudit record. (eaxScada 82cb5ee5) - How to write a dataset you can check again. A
sumoravgover decimal (floating-point) values, computed in parallel, can differ in its last digits from one run to the next on unchanged data, so its hash can differ: writeavg(value ORDER BY ts)(or another ordered aggregate), orround(...)to the precision you need. A result that can reach its row limit (for example 100,000 rows for a PDF, 1,000,000 for a workbook) needs anORDER BYover columns that make each row unique, so the same rows are kept on each run. Result hash (eaxScada 82cb5ee5) - Upgrade notes (what now behaves differently):
- New run records, analytics query results and their audit records carry hashes in the new encoding: a hash recorded before this release is not comparable with one made after it, even on the same data. The run’s
data_sha256in the report footer and on the workbook’s About sheet changes the same way. - Hashes recorded before this release stay as recorded in run records, archive sidecars and the audit trail; nothing recomputes them. Archive Verify and signatures are over the files’ bytes and are unchanged. - Unchanged: the values shown in reports, workbooks, exports and the analytics workspace.
The result hash encoding recorded beside each hash (24 November, eaxScada merge 9e486edc; Pro and Enterprise; safety: report and audit records):
- Each stored result hash now names its encoding in
result_hash_v. A new run record carriesresult_hash_v: eax-dataset-v2on the record (fordata_sha256) and on each dataset (for itsresult_sha256), so also in the archive sidecar and therun.succeedandrun.failaudit records. Run record and statuses (eaxScada 9e486edc) - The audit records name it too. An
analytics.queryrecord carriesresult_hash_v:eax-dataset-v2for a query over a dataset family,eax-extract-v2for a query over extracts. Arun.previewrecord for a dataset preview or view carrieseax-dataset-v2. Audit events (eaxScada 9e486edc) - Upgrade notes (what now behaves differently):
- Records made before this version have no
result_hash_v; read them aseax-dataset-v1(an olderanalytics.queryrecord over extracts:eax-extract-v1). Nothing rewrites them. - Unchanged: the hash values, the report footer and the workbook’s About sheet. Nothing recomputes or verifies an old hash. The query result and the preview answers over HTTP do not carryresult_hash_v.
Local tags fed by an eaxPLC go Bad when that PLC stops reporting (24 November, eaxScada merge f182381e; Starter, Pro and Enterprise; safety: values operators see, alarm inputs):
- SAFETY: a local tag written by a script pinned to an eaxPLC goes Bad when that PLC is silent. When the PLC sends neither status nor values for 20 s, each such tag goes Bad, its last value kept. eaxScada looks every 5 s. The timestamp is the last reading’s plus 1 ns (the same millisecond on screen), so the last Good reading stays in the history. The PLC’s next value makes the tag Good again. Before, the tag stayed Good forever: a frozen number shown and alarmed on as a reading. Tags fed by an eaxPLC that stops reporting (eaxScada 69bd77f4)
- SAFETY: only the PLC’s own writes go Bad. A tag that an operator or a script on eaxScada wrote since the PLC’s last write is not touched. A writable tag whose last write came from the PLC goes Bad like the others. (eaxScada 69bd77f4)
- SAFETY: alarms and interlocks treat it as any Bad value. The tag’s alarms are held (they neither trip nor clear), and an alarmed tag raises its “Signal unreadable” alarm. An interlock that reads the tag blocks its command, unless If the interlock reads a Bad value is Allow. Values that cannot be read (eaxScada 69bd77f4)
- The historian and the log record each silence once. The default policy logs one Bad point per tag per silence; a logging rule
ON_CHANGEwith a deadband did not log a change of quality alone, as for driver tags. This is fixed in 897: a rule now logs each change of quality class at once. The log has one warning per script per silence: “eaxPLC not reporting: the tags its script wrote are Bad, last value kept”. The tag itself shows no reason for its Bad quality; the script’s status in the Scripts (n) tab names the PLC (“no status from id for ns”). (eaxScada 69bd77f4) - Upgrade notes (what now behaves differently): - Screens show these tags Bad, with the red ✕, 20 to 25 s after their eaxPLC stops reporting, where they showed the last value as Good. Tell operators that this means the PLC link, not the sensor. - An alarmed tag raises its “Signal unreadable” alarm during the silence, and its other alarms are held. A command whose interlock reads such a tag is blocked during the silence unless its Bad-value setting is Allow: check that each stop command uses Allow or has no interlock. - Not covered by this merge, covered by the next one (856 to 860): the tags of a pinned script that is disabled, unpinned or deleted, and a PLC that keeps reporting but says a script is not running. - Unchanged: tags written by scripts on eaxScada, driver tags, and a tag written by an operator after the PLC’s last write.
Local tags fed by an eaxPLC also go Bad when their script stops there or is removed; the reason is carried on the tag (24 November, eaxScada merge 3b0c44a7; Starter, Pro and Enterprise; safety: values operators see, alarm inputs):
- SAFETY: a stopped or crashed script’s tags go Bad, while its PLC still reports. When the PLC sends no status saying the script runs (Running) and no values from it for 20 s, the tags the script wrote go Bad the same way as for a silent PLC: last value kept, 20 to 25 s after the last sign it ran. Reason: “script id not running on eaxPLC node”. A running script that does not change a value stays Good: its status keeps saying it runs. Before, these tags stayed Good, frozen. Tags fed by an eaxPLC that stops reporting (eaxScada a580c381)
- SAFETY: a script that no longer runs on its PLC leaves its tags Bad. When a pinned script is disabled, unpinned, deleted or pinned to another PLC, the tags it wrote go Bad at eaxScada’s next look, within 5 s, last value kept. Reason: “script id no longer runs on eaxPLC node”. Before, they kept their last quality forever. (eaxScada a580c381)
- The tag carries the reason of its Bad quality.
quality_reasonin the tag’s JSON (REST and the live data socket’sTAG_SNAPSHOT) andrinTAG_UPDATESnow hold the reason of any Bad quality that has one, not only of out of service. A silent PLC gives “eaxPLC node not reporting”. The next write clears it. Drivers give no reason for their Bad, so driver tags are unchanged. Screens are unchanged too: the badge still reads “Bad”. TAG_UPDATES (eaxScada a580c381) - Unchanged rules. Only a tag still holding the PLC’s own last write is touched. Alarms are held on the Bad value, and an alarmed tag raises “Signal unreadable”. The historian logs one Bad point per tag per silence. The log warnings now read “eaxTags script not running on its eaxPLC: the tags it wrote are Bad, last value kept” and, for a removed script, “eaxTags script no longer runs on its eaxPLC: the tags it wrote are Bad, last value kept”. (eaxScada a580c381)
- Upgrade notes (what now behaves differently):
- Screens show a pinned script’s tags Bad, with the red ✕, 20 to 25 s after the script stops or crashes on its eaxPLC, and within 5 s after the script is disabled, unpinned, deleted or pinned to another PLC. They used to show the last value as Good. A stop command whose interlock reads such a tag is blocked unless its Bad-value setting is Allow.
- API clients that read
quality_reason(orr) now get it on Bad tags too, not only on out-of-service ones. - Tools that match the old log text “eaxPLC not reporting: the tags its script wrote are Bad, last value kept” must match the new texts in 859. - Unchanged: tags of a script that runs, driver tags, tags written by an operator or a script on eaxScada after the PLC’s last write, and the badge text.
Simulated local tags are marked simulated everywhere (24 November, eaxScada merge 68cb0774; Starter, Pro and Enterprise; safety: values operators see, interlocks, write limits, the plant e-stop signal, history):
- SAFETY: an eaxTag defined
"simulated": trueis now marked simulated by the server itself. Each value it takes carries the mark, as a value from an accepted simulated eaxPLC does: the live data socket (simulatedinTAG_SNAPSHOT,sinTAG_UPDATES), SIM on screens and trends, history samples stored simulated, alarm events simulated. Before, only/api/tagsflagged it; screens, the historian, alarms and interlocks took the value as a plant reading. Tag definition (eaxScada b0eb9bbc) - SAFETY: a screen interlock that reads such a tag is active, whatever the value, and its command is blocked, even when its Bad-value setting is Allow. Tick Allowed in commissioning on the interlock to let it read the value. On (commissioning only): accepted and marked (eaxScada b0eb9bbc)
- SAFETY: such a tag is never a usable limit. A write whose bound limit tag is a simulated eaxTag is refused, as for a limit that cannot be read (fail closed). No setting changes this. Limit the input on the screen (eaxScada b0eb9bbc)
- SAFETY: as the plant e-stop signal, such a tag reads as unknown, never as the plant’s state, as when the signal cannot be read. Allowed in commissioning never applies to the e-stop signal. Values that cannot be read (eaxScada b0eb9bbc)
- Turning the flag on or off. Saving a tag with
simulatedturned on writes its held Good value again at once, marked. Turning it off leaves the held value marked until the tag’s next write: that value came from the simulation. (eaxScada b0eb9bbc) - Upgrade notes (what now behaves differently):
- Screens and trends show SIM on every object bound to a simulated eaxTag. New history samples and alarm events of these tags are stored simulated. Samples recorded before this release keep no mark.
- A command whose interlock reads a simulated eaxTag is blocked until the interlock is ticked Allowed in commissioning, whatever its Bad-value setting. Check each command that must work during commissioning, and keep stop commands free of such an interlock.
- A write whose limit tag is a simulated eaxTag is refused. Bind the limit to a tag that is not simulated.
- A simulated eaxTag set as the plant e-stop signal reads as unknown. Set the signal to a plant tag.
- API clients that read
simulated(ors) now get it on simulated eaxTags too, not only on values from a simulated eaxPLC. - Unchanged: eaxTags that are not simulated, the tags’ values, and alarm evaluation (an alarm still trips and clears on the value).
The operator runtime opens without waiting for the 3D engine (24 November, eaxScada merge b1b9d8c4; every edition):
- The 3D engine loads only when a 3D view opens. The view shows “Loading the 3D view…” first, then the scene. When the engine cannot load, the view says “The 3D engine could not be loaded. Check the connection, then open the screen again.” The next opening tries again. Runtime and Dev Studio (eaxScada f9430e07)
- The other large scripts no longer hold back the first screen. In our measurement on a phone, the first paint fell from 22 s to 1.6 s on a cold start and from 2.7 s to 0.5 s with a warm cache. (eaxScada f9430e07)
- The start-up note is translated. It reads “Loading the operator screens…” in the operator’s language. (eaxScada f9430e07)
- Unchanged: values, commands, holds and the deliberate-tap gate. (eaxScada f9430e07)
Phone Cards name each value only by its own label (24 November, eaxScada merge cd94b5cd; every edition; safety: values operators see):
- SAFETY: a value on a phone card is named only by its own label. A number, a scale tick or a limit mark (“80”, “45 m³/h”, “LL 8”) never names a value. A label names one value only: the nearest one that has it on its row or just above. A value with no such label is listed under its tag name. Before, a card could show a value under a wrong name, for example a tank level under the flow transmitter label next to it, or a pressure named “25” after a scale tick. Read a screen (eaxScada e7d8db69)
- Upgrade notes (what now behaves differently): - Some card rows that used to show a neighbouring label or a number now show the tag name. To give such a value a name, place its label just left of it on the same row, or just above it. - Unchanged: the values, their quality, the screen view and the commands on the cards.
Simulated driver channels are marked simulated everywhere (24 November, eaxScada merge 61feff7b; Starter, Pro and Enterprise; safety: values operators see, interlocks, write limits, the plant e-stop signal, history):
- SAFETY: a driver channel in simulated mode now has its values marked simulated by the server itself. A channel whose settings say
"simulated": truegenerates its values, and each one now carries the mark, as a value from an accepted simulated eaxPLC does: the live data socket (simulatedinTAG_SNAPSHOT,sinTAG_UPDATES), SIM on screens and trends, history samples stored simulated, alarm events simulated. Before, only/api/tagsand the dashboard cards flagged it; screens, the historian, alarms and interlocks took the generated value as a plant reading. Test without hardware (eaxScada 44cbdd32) - SAFETY: a screen interlock that reads such a tag is active, whatever the value, and its command is blocked, even when its Bad-value setting is Allow. Tick Allowed in commissioning on the interlock to let it read the value. On (commissioning only): accepted and marked (eaxScada 44cbdd32)
- SAFETY: such a tag is never a usable limit. A write whose bound limit tag comes from a simulated channel is refused, as for a limit that cannot be read (fail closed). No setting changes this. Limit the input on the screen (eaxScada 44cbdd32)
- SAFETY: as the plant e-stop signal, such a tag reads as unknown, never as the plant’s state. The reason now names every simulated source: “tag reads a simulated value (v, from a simulated source: a simulated PLC, driver channel or eaxTag), never the plant’s e-stop state”. It used to end “(v, from a simulated PLC: virtual commissioning)”. Values that cannot be read (eaxScada 44cbdd32)
- Switching a channel to or from simulated restarts it. The old driver stops first, and what it still had in flight is dropped. The next reading of each tag is then published, with the new mark; until then a tag keeps its held value and that value’s mark. The log says “[CHANNEL MODE] channel: values now simulated (marked SIM)” or “values now from the device (not simulated)”. A tag removed from the channel loses the mark. (eaxScada 44cbdd32)
- The Accept simulated PLCs record states the new effect. When the setting is turned on,
PLC_SIM_ACCEPT_CHANGEDnow says: “the values of simulated PLCs are now taken in, each marked Simulated on screens, in the tag lists and the history; alarms are raised from them, their events marked simulated; an interlock reading one stays active unless it is allowed in commissioning, and a limit or the e-stop signal never accepts one”. It used to say that interlocks and alarms treat them as values. Accept or refuse simulated PLCs (eaxScada 44cbdd32) - Upgrade notes (what now behaves differently):
- Screens and trends show SIM on every object bound to a tag of a simulated channel. New history samples and alarm events of these tags are stored simulated. Samples recorded before this release keep no mark.
- A command whose interlock reads a tag of a simulated channel is blocked until the interlock is ticked Allowed in commissioning, whatever its Bad-value setting. Check each command that must work during commissioning, and keep stop commands free of such an interlock.
- A write whose limit tag comes from a simulated channel is refused. Bind the limit to a tag that is not simulated.
- A tag of a simulated channel set as the plant e-stop signal reads as unknown. Set the signal to a plant tag.
- Tools that match the e-stop reason “from a simulated PLC: virtual commissioning”, or the old
PLC_SIM_ACCEPT_CHANGEDtext, must match the new texts in 876 and 878. - Unchanged: channels that are not simulated, the generated values,/api/tags(it already flagged them), and alarm evaluation (an alarm still trips and clears on the value).
A fully simulated screen shows one SIMULATED chip (24 November, eaxScada merges 072947aa, 770fcb94 and 0d7ccf0d; every edition; safety: values operators see):
- One SIMULATED chip when every value on the screen is simulated. The runtime counts every value the page shows: the screen, its docks, and the inner screens and popups that are open. When they are simulated and none is real for 500 ms, one SIMULATED chip appears, white on violet, with the tooltip “Every value on this screen comes from a simulation”. On a desktop it sits in the operator controls at the bottom right, before the connection light. It never moves into More, and the controls stay opaque while it shows. SIMULATED chip (eaxScada fea7ebe1)
- A small violet dot replaces the full SIM badge on each simulated object, at its top left, with the same tooltip. The mark is never dropped. (eaxScada fea7ebe1)
- SAFETY: one real value brings the full SIM badges back at once, with no delay, and the chip goes. A Bad value, a value not yet received or a refused value counts as neither real nor simulated. (eaxScada fea7ebe1)
- On a phone, the chip sits in the top bar before the alarm button, and a simulated row shows the violet dot instead of the SIM chip, with the same spoken label. Each lamp dot on a card now has a spoken name and state: the lamp’s name and what its tags read now (On or Off, or the value, the quality when not Good, and “simulated”). Simulated values (eaxScada ecde6135)
- Room for the screen’s name on the phone. While the chip shows, the edition chip leaves the top bar, and the screen’s name and the alarm button’s text may take two lines. The Account sheet now lists Edition and licence: edition; a tap opens the licence, as the chip does. Desktops are unchanged. (eaxScada 137a6e70)
- Upgrade notes (what now behaves differently): - On a screen where every value is simulated, operators see one SIMULATED chip and a small violet dot per object, not a SIM badge on every object. Tell them that full SIM badges mean the screen mixes real and simulated values. - On a phone, the edition is in the Account sheet while the SIMULATED chip shows. - Unchanged: the values, their quality marks, the commands, interlocks, alarms and history.
Phone Cards name lamps by their own label and show one dot per value (24 November, eaxScada merges a769990b and b1916e6b; every edition; safety: values operators see):
- SAFETY: a lamp on a phone card is named only by its own label: the text to its right on its row, else the text just above or below it. A label names one lamp or value only, the nearest. A pipe caption (“TO …”, “FROM …”, arrows) or a reading never names a lamp. A lamp with no label of its own is named by its Phone label, else by the tags its colour reads. Before, a pump’s running lamp could be named “TO LOADING”, the caption of the pipe beside it. Read a screen (eaxScada 3a7264ff)
- SAFETY: every bound lamp keeps a row. Before, a lamp could be left off the card. A value drawn inside a small readout box takes the label above the box as its name. (eaxScada 3a7264ff)
- A card title is never a reading. It is the panel’s Phone label, else the first text at the top of the panel that holds no reading and is not a pipe caption. A panel whose top holds only such texts gets “Process” (the next ones “Section 2”, “Section 3” and so on). Before, a card could be titled “PRODUCT INLET 30 m³/h”. (eaxScada 3a7264ff)
- SAFETY: a status lamp drawn on a value’s chip or readout box is that value’s row dot. When the lamp has no name of its own and reads the same device as the value, it colours the value row’s dot and counts for its quality mark. It is no longer listed again as a lamp row. Before, a line’s controller pill showed twice. (eaxScada b757ad78)
- SAFETY: a value’s name never holds a reading. The name is the first label to its left without a reading, else the label above without one, else a link text without one, else the tag. Before, a level could be named “WET WELL 20 m³”, the well’s volume caption. (eaxScada b757ad78)
- Upgrade notes (what now behaves differently): - Some lamp rows that showed a pipe caption or a neighbouring label now show the lamp’s own label or its tag. To give a lamp a name, place its label just right of it, or just above or below it, or set a Phone label. - A lamp drawn on a value’s chip no longer has its own row: its state is the dot of that value’s row. - Some cards that were titled by a reading are now titled “Process” or “Section n”. Set a Phone label on the panel to name it. - Unchanged: the values, their quality, the screen view and the commands on the cards.
Every store is closed at shutdown (24 November, eaxScada merges e22d3138 and 02c99ad1; every edition; data durability):
- The recipe and batch store and the design review search archive are now closed at shutdown, so their DuckDB files (
scada_recipes.duckdbanddata/collab/archive.duckdb) are checkpointed. Before, they were left open, and every start replayedscada_recipes.duckdb.wal. No data was lost: DuckDB replays its log. Stopping without cutting a checkpoint short (eaxScada 57d9ebff) - As a Windows service, a stop now waits for every store to close. The service reports its progress to Windows while it stops, and reports Stopped only once the stores are closed, at most 5 minutes later. Before, it reported Stopped after 30 s, possibly in the middle of a close. At an OS shutdown, Windows applies its own time limit. Stopping without cutting a checkpoint short (eaxScada d8fef4c6)
- A start refused after the stores were opened now closes them. The log line and the exit code 1 are the same as before. (eaxScada d8fef4c6, 962bf7ea)
- A search during shutdown answers that the archive is unavailable (
503 archive_unavailable) instead of opening the archive again. Reviews, decisions and comments are not affected. The archive (eaxScada d8fef4c6) - Upgrade notes (what now behaves differently):
- A Windows service stop can take longer than before on a busy system, up to the 5-minute bound. A script that waits for the service to stop must allow for this time.
- The first start after the upgrade may still replay a
scada_recipes.duckdb.walleft by the old version. Later starts find the file checkpointed. - Unchanged: the stored recipes, batches, reviews and comments, and the Linux and Docker stop times.
A logging rule logs every change of quality at once, whatever its deadband (29 November, eaxScada merge 9359944f; Starter, Pro and Enterprise; safety: history operators and reports read):
- SAFETY: a logging rule now logs a change of quality class or of the simulated marker at once, whatever its deadband. When an update’s quality class (Good, Uncertain or Bad) or its simulated marker differs from the last point the rule logged for that tag, the update is logged under every method:
ON_CHANGE,TRIGGERED, andPERIODICinside its sample interval. The point has the update’s time, the value the tag holds and its new quality. Before, under anON_CHANGEorTRIGGEREDrule with a deadband, a tag that went Bad with its value unchanged logged nothing, so its history kept showing the last Good sample. Quality of periodic and triggered samples (eaxScada 1e305414) - One point per change. Repeated updates of the same class and marker go through the deadband as before. A change of code inside one class (for example Bad 0x18 to Bad 0x00) is not a change. Deadbands (eaxScada 1e305414)
- A
TRIGGEREDrule whose trigger is off still logs nothing. Its first update once the trigger is on again is logged if its quality differs from the last point it logged. (eaxScada 1e305414) - Upgrade notes (what now behaves differently):
- Under
ON_CHANGEandTRIGGEREDrules with a deadband, a tag that goes Bad or Uncertain, or comes back Good, gets one history point at once, at the update’s time, with the value it holds and its new quality. Its history, trends and reports now show the Bad or Uncertain period where they showed the last Good sample. - The same for a change of the simulated marker, and under aPERIODICrule inside its sample interval. - Repeated updates of the same class and marker go through the deadband as before. A code change inside one class (Bad 0x18 to Bad 0x00) is not a change. - ATRIGGEREDrule whose trigger is off logs nothing. Its first update after the trigger is on again is logged if its quality differs from the last logged point. - After a restart, and for a wildcard rule’s first update of each tag, one point per tag is logged whatever the deadband: the last logged quality is not kept across a restart. - The note in 854 and in Tags fed by an eaxPLC that stops reporting, that a deadbandON_CHANGErule does not log a change of quality alone, no longer applies. - Unchanged: anON_CHANGErule with deadband 0, tags without a rule (the default policy already logged a quality change at once), and min/max/average buckets (Good samples only, as before).
eaxTags script values take the quality of their inputs (29 November, eaxScada merge 33f66639; Starter, Pro and Enterprise; safety: values operators see, alarm and interlock inputs):
- SAFETY: a value a script computes on eaxScada takes the worst quality of the tags its tick read. A tick’s writes are applied when it ends. Good inputs give a Good value. An Uncertain input stores the value Uncertain, with a reason. A Bad input, or a tag that does not exist, keeps the output’s last value and makes it Bad, with a reason that names the input (“script id: input path Bad (…)”). A disabled channel makes the output out of service. The tags the script writes are not counted as its inputs. Before, every value a script wrote was Good, even one computed from a Bad, waiting or frozen input. Quality of a script’s values (eaxScada 356893f8)
- SAFETY: a value computed from a simulated input is marked SIM, on screens, in the history and on alarm events. An interlock that reads it is active unless it is ticked Allowed in commissioning. Before, it was shown as a plant value. What a write stores (eaxScada 356893f8)
- SAFETY: a tag the script did not write is marked too. When a tick reads an input that is not Good and does not write one of the script’s known outputs (the paths its source writes literally, and every tag it has written, kept with its state), that output takes the tick’s quality. A script that returns early when an input is not Good no longer leaves its outputs Good. Only a tag still holding the script’s last write is touched, once per spell. Outputs the tick did not write (eaxScada 356893f8)
- SAFETY: a failing or stopped script leaves its tags Bad. After 3 failing ticks in a row and at least 10 s, every known output goes Bad, “script id failing: error”, and the writes of failing ticks are dropped until a tick succeeds. A disabled or deleted script, or one pinned to an eaxPLC, makes them Bad at once, “script id no longer runs”. A standby, a stopped runtime and a server stop do not. When the script fails or stops (eaxScada 356893f8)
- No alarm flood at start. While an input waits for its first value, an output no script has written since eaxScada started is left as it is. One written since goes Bad. (eaxScada 356893f8)
- Only a value written from Good inputs makes an output Good again. An input that recovers changes nothing until the script writes the output. (eaxScada 356893f8)
- An operator’s tag (writable) is never marked. A script’s write to it from inputs that are not Good is not applied, and the script’s status logs it once. Operator tags (writable) are never marked (eaxScada 356893f8)
tags.getof a path the tick already wrote returns the value written, which is applied when the tick ends. Globals and functions (eaxScada 356893f8)- New:
tags.setBad(path, reason)andtags.set(path, value, {quality, reason, from}).qualityis"Bad"or"Uncertain";"Good"is refused, and a misspelt key throws.fromlists the tags a value is computed from, so the write is judged by them alone;{from: []}takes one write out of the rule. A script saved by an AI client may not narrow below the tick’s worst input. On an eaxPLC (pinned scripts)quality,reasonandtags.setBadthrow “this host has no tag qualities”, andfromis ignored. The Studio’s script help and the code editor’s completion list them. Mark a value yourself, Name the inputs of a write (eaxScada 356893f8, workspace e6f6a88c) - The reason is kept on Uncertain too. A script’s Uncertain value carries its reason in
quality_reason, as Bad values do. What a write stores (eaxScada 356893f8) - SAFETY: alarms, interlocks and history follow. Alarms on a Bad derived tag are held, and an alarmed tag raises “Signal unreadable”. An interlock that reads it blocks its command, unless If the interlock reads a Bad value is Allow. The historian logs one point per change of quality (with 897). What follows from a Bad or Uncertain output (eaxScada 356893f8)
- The demo’s
plant-derivedscript names the input of each value ({from}), so one silent controller marks only its own figures. Scripts that compute several things (workspace e6f6a88c) - Upgrade notes (what now behaves differently):
- The rule is on for every existing script from the first start, in Starter, Pro and Enterprise. There is no switch per script (founder decision, 29 November).
{from: []}takes a single write out. - Tags computed by scripts now go Bad or Uncertain with their inputs, keeping their last value when Bad. A value computed from a simulated input is marked SIM (founder decision, 29 November). - “Signal unreadable” alarms can now appear on alarmed tags a script computes, when an input fails or the script fails or stops. - SAFETY: a command whose interlock reads such a tag passed on a frozen value before. It now blocks while the tag is Bad, unless If the interlock reads a Bad value is Allow. With a simulated input it blocks outside commissioning, unless the interlock is ticked Allowed in commissioning. Check each command, and keep stop commands free of such an interlock. - History, trends and reports now show the Bad and Uncertain periods of these tags. - A script that computes several unrelated values withoutfromover-marks: one Bad input marks every value it writes. Add{from: [...]}to each write, as the demo’splant-deriveddoes. - A script that checkedtags.qualityand returned early needs no edit: its outputs now go Bad instead of keeping their last Good value. - Disabling or deleting a script now makes the tags it wrote Bad. Before, they kept their last value, Good. A save whose new source no longer writes a literal path makes that tag Bad, “script id no longer writes it”. - A script’s write to a writable tag from inputs that are not Good is no longer applied. - Values are timestamped when the tick ends, not at thetags.setcall. - A script that passed a third argument totags.setnow has it read as options: a value that is not an object withquality,reasonorfromthrows (nullandundefinedare ignored). - Unchanged: values computed from Good inputs, scripts pinned to an eaxPLC (Good values, Bad when the PLC stops reporting), write ranges, and the refusal of AI-made scripts’ writes to safety tags.
DuckDB 2.0.1 (29 November, eaxScada merge 86acb423; every edition; safety: every database store: historian, audit trail, alarms, security, recipes, genealogy, shift log index, log console, collaboration archive). A patch release of the same line: no eaxScada code changes, and no sync, write-ahead log or checkpoint setting changed:
- The package ships DuckDB 2.0.1 (before: 2.0.0) and the historian’s encryption extension for it in
bin\historian_ext\v2.0.1\windows_amd64\(Linux:historian_ext/v2.0.1/linux_amd64/). Thev2.0.0folder is no longer used. Ifhistorian.extension_dirorEAX_HISTORIAN_EXT_DIRpoints at your own bundle, put the 2.0.1 bundle there before you upgrade: otherwise the encrypted historian, and on an install with encryption at rest the audit trail and genealogy, refuse to start, with the expected path in the log. eaxCollab’s archive bundle moves the same way (duckdb_ext\v2.0.1\...). Encryption at rest on offline and air-gapped installs (eaxScada 88aaeb50) - The storage format pin is unchanged. Every file is still written in the v1.0.0 storage format (header 64; 68 when encrypted). 2.0.1 has the same storage and serialization versions as 2.0.0, so a 2.0.1 server’s files, a write-ahead log it left behind included, open with the previous package, and the other way round. System Health’s Database stores and the start log name the engine
v2.0.1. Engine version and file format (eaxScada 88aaeb50) - Engine fixes of the patch release, among them: index entries lost by an automatic checkpoint after a write-ahead log replay; a forced checkpoint on an empty write-ahead log that left the file unopenable; large window and
GROUP BYaggregates that hung or ran out of memory at the memory limit. Rows acknowledged after a failed commit on the same instance could be lost upstream: every eaxScada store already replaced its instance after a failed commit, so this changes nothing here. (eaxScada 88aaeb50) - SAFETY: the administrator’s verified Repair stays. A checkpoint cut short (a power loss, a killed process) can still leave a file unopenable on 2.0.1: the engine fix is not released yet. A commit that skips the write-ahead log is still visible before it is durable, so every store keeps that path off. When a checkpoint was cut short: repair the file (eaxScada 88aaeb50)
- Upgrade notes (what now behaves differently):
- A server with its own extension bundle needs the 2.0.1 bundle in
<folder>/v2.0.1/<platform>/before the upgrade. - Going back to the 2.0.0 package on the same work folder works: it opens every file 2.0.1 wrote. - Unchanged: every sync and checkpoint setting, the write paths, the stores’ contents and the storage pin.
A trend draws each sample until the next one (29 November, eaxScada merges 35d2444d, d4a2cb07 and 0c0e0f73; every edition, report trends in Pro and Enterprise; safety: values operators see). A tag logged on change has one sample when it changes, then none until it changes again (with 897, one when its quality changes):
- SAFETY: a Bad sample stays Bad until the pen’s next sample. Its shaded band runs to that sample. A Bad last sample runs to now on a live trend, to the end of the read on the History page and in the Studio’s Trends, and to the end of the range on a dashboard card, never past now. Before, a pen whose last sample was Bad drew a band of no width: a tag Bad now showed nothing at the right edge. How long a sample holds (eaxScada 0e27b017, 3c6df975)
- SAFETY: a Bad reading without a value is a Bad sample. A live update that is Bad and has no number starts a Bad span on a screen trend. Before, it was dropped, and the trend joined the Good samples on both sides as if Good in between. A history sample without a value, and a dashboard bucket with no Good sample, are drawn as Bad spans, not as plain “No data” gaps. On a dashboard card, no “No data” break cuts a Bad span. (eaxScada 0e27b017)
- SAFETY: a Good or Uncertain value holds until the next sample. A sample that no line joins to the next one (the next is Bad, has no value, or there is none) is drawn as a lighter flat line: solid when Good, dashed when Uncertain. It runs to the next sample, or to the same end as a Bad band. It never runs across a Bad span, into a stretch with no data, or past now. Line pens only. Before, a value that stayed put under an
ON_CHANGErule (one sample) was drawn as nothing and read as “no data”. How long a sample holds (eaxScada 3c6df975) - Each recorded sample has a dot on a line pen of up to 300 samples; on a denser pen, the samples a held line starts from. A held line ends without a dot: it is not a sample. (eaxScada 3c6df975)
- The Values table of a Trend with values says Bad. A Bad cell says Bad in rose, never an empty dash. Inside a Bad span, the rows of the other pens show the pen as “Bad · 10:42:05”, the time the span began. A row with a Bad pen has a rose accent, an Uncertain value is marked “(Uncertain)” in amber, and the CSV export writes the same words. (eaxScada 0e27b017)
- SAFETY: the History page shows simulated samples and never shows a missing value as 0. The page (
/history) dropped the history’s simulated marker: simulated samples now get the violet SIM band and dots, and the samples table a Source column (plant or simulated, with a SIM badge and a violet row accent; in the CSV too). The status line counts the simulated samples. A sample without a value shows “—” (empty in the CSV), where it printed 0.000. The trend holds to the end of the read: the range’s to, or the time a relative range was asked for, never past now; its time axis reaches it. (eaxScada 910f772b) - Report trends hold to the end of the report’s range (Pro, Enterprise), never past the time the report runs: a Bad last sample’s band, a simulated last run’s SIM band and a held value reach it. Before, a Bad last sample drew no band and a steady value one point, short of the report’s end. A report without a range is unchanged. (eaxScada 910f772b)
- A live trend is redrawn every 5 s while its page is visible, so a held value and a Bad band follow now. A live trend has a time window, or gets live samples. Nothing is read again. A hidden browser tab is not redrawn; it is redrawn once when shown again. The History page is never redrawn this way: it shows its read. (eaxScada 910f772b)
- The classic dashboard trend card keeps Bad readings without a value as Bad spans, from the history and live. Before, such a history sample was drawn as 0, and a live one was dropped. (eaxScada 3c6df975)
- Upgrade notes (what now behaves differently): - Trends show more: Bad bands that run to the next sample or to now, held values as lighter flat lines, and dots at the recorded samples. A tag Bad since before the right edge now shows Bad there. - The Values table of a Trend with values shows “Bad” and “Bad · time” where it showed “—”, and its CSV writes these words. - The History page’s samples table has a new Source column, also in its CSV; a missing value is “—” and an empty CSV cell, not 0.000. - Unchanged: the stored samples, the history API’s answers, the quality classes and the downsampling.
Cross-reference of eaxTags scripts and their quality (29 November, eaxScada merge 2b1b2c21; every edition; safety: values operators see):
- Where used counts
tags.setBadas a write, andtags.qualityand the paths of a write’s{from: [...]}as reads. A script that only marks a tag Bad, or only checks its quality, is listed under that tag, and the tag is not reported unused. A script that does not parse is scanned for the same calls. Where used and Hand over to driver (eaxScada 8536ff1e) - SAFETY: Hand over to driver is refused while an enabled script calls
tags.setBadon the path (script_writes), as fortags.set. Before, such a script did not count, and the handover went ahead. Disable the script or remove the call first. What blocks a handover (eaxScada 8536ff1e) - A warning when two scripts read each other’s values. With 901, once one of the values goes Bad, the two keep each other Bad after the cause is gone. The save is not refused: both scripts’ status shows an amber warning naming the scripts and the paths, and suggesting
{from: [...]}. The save’s answer carries it inwarnings. Enabled scripts on eaxScada only; loops between two scripts only. A script saved by an AI client cannot break the loop withfrom: the warning says a person must save that change. Two scripts that read each other (eaxScada 8536ff1e) - The AI assistant is told how quality propagates when it writes an eaxTags script: a written value takes the worst quality of the tags the tick read,
tags.setBadmarks an output Bad,{from: [...]}makes each output follow its own inputs, and in a script it makesfrommay add inputs but never narrows below the tick’s worst. (eaxScada 8536ff1e) - Upgrade notes (what now behaves differently):
- A handover of a path that an enabled script marks with
tags.setBadis now refused. -POST/PUT /api/dev/eaxtags/scriptsanswers the saved script withwarningswhen it is in a loop;GET /api/dev/eaxtagsgives the loop in each script’sstatus[].warning, on its own line after any other warning. - Unchanged: no save is refused for a loop, and the scripts run as before.
The sample before a range, on request (29 November, eaxScada merge fb54151d; every edition; safety: history operators and the AI read). A tag Bad, or steady, for longer than a range has no sample inside it under an ON_CHANGE rule; its last sample before the range is the state the range opens with:
- New:
GET /api/history?prior=1. Each tag’s points are led by its last point beforefrom, marked"before": true, and the answer has the headerX-History-Prior: true. Only when the tag’s points are the whole range (fewer thanlimit), and not for a read without a start. The search has no time bound. Apriorthat is not true or false is refused (400). The sample before a range (eaxScada beba0e1b) - New:
include_beforeon the MCP toolscada_query_tag_history(defaultfalse). Each tag’s entry getsbefore, withtimestamp_iso,value,qualityandquality_class, for raw points and buckets, when the entry holds the whole range. Data quality in the values the assistant reports (eaxScada beba0e1b) - Dashboard history frames carry
meta.before(timeMs,value,quality,simulated) in the answer ofPOST /api/dashboards/query, for raw and aggregated history, unless the frame is truncated. Aggregated frames gain the fieldlast_quality, the class of each bucket’s last sample: a bucket where the tag went Bad after Good samples isuncertainwith a Good average, and itslast_qualitybadsays the tag is Bad from there on. No card drawsmeta.beforeyet; a custom chart’s code getslast_quality. The sample before the range (eaxScada beba0e1b) - Upgrade notes (what now behaves differently):
- Without
priororinclude_before, the answers of/api/historyand of the MCP tool are unchanged. - The dashboard query answer hasmeta.beforeon history frames and a new last field,last_quality, on aggregated frames. A client that reads the fields by position must allow it. - When the history store does not answer, a read with the sample before fails as a whole, as the window read does:503 history_unavailablefrom/api/history, an error from the tool, a failed dashboard query.
A failed store reopen waits its full delay (29 November, eaxScada merge a571ca0f; builds with the columnar store):
- The delay before the next reopen counts from the end of the failed try. A database store whose reopen fails waits 1 s, doubling to 1 min, before it tries again. Before, the delay counted from the start of the try, so a try slower than the delay (a busy disk, a network share) was followed at once by the next one. When a write leaves the database unusable (eaxScada 26aa5023)
A live trend stops where the live link goes down (29 November, eaxScada merge d6bad4c1; every edition; safety: values operators see). The live link is the browser’s /ws socket to the server:
- SAFETY: a live trend stops where the live link goes down, and draws no line across the outage. The line, a held value, and the Bad or SIM band of the last sample end at the moment the link went down. They go on only once the values are in again after the reconnect: the server’s answers, or the first live sample. Before, while the link was down, a live trend went on holding its pens’ last samples up to now, redrawn every 5 s, so a steady value read as still arriving; and when the link came back, the line joined the last sample before the outage to the first one after it. This applies to the screen trend, the classic dashboard trend card, the Trend with values (Chart | Values) and the Studio’s Trends. The History page, report trends and the dashboard cards that read by query are not live trends and are drawn as before. When the live link goes down (eaxScada 35bd98ef)
- A grey band covers each span the link was down, and a “Live link down” chip shows while it lasts. The amber chip sits in the trend’s top row (the legend keeps clear of it). The band stays after the link is back, as long as the span is in the trend’s window, and the tooltip inside it says “Live link down”. The words are in the operator’s language (English, French, German, Spanish, Italian). (eaxScada 35bd98ef)
- Upgrade notes (what now behaves differently): - During an outage of the live link, live trends no longer draw the last value, or a Bad or SIM band, up to now. After the outage, no line, held value or band crosses it: the grey band shows the span instead. - Unchanged: trends that do not follow live values (the History page, reports, the dashboard cards that read by query), the stored samples, and trends on pages without the live link.
A live link that goes silent is found (29 November, eaxScada merge e1f0d6b6; every edition; safety: values operators see):
- SAFETY: a live link that stays open while nothing reaches it is treated as down, within 20 to 24 s. Before, the browser learnt that the link was down only when the socket closed. A pulled cable, a connection a router or firewall forgot, or a server stopped without closing its sockets left the socket open: GATEWAY OFFLINE never showed, values were not marked stale and live trends read as live. The server now sends a heartbeat every 5 s on every
/wssocket. A page that has received one and then receives nothing for 20 s, on two checks 2 s apart, closes the socket and handles it as a closed link: GATEWAY OFFLINE, values stale (the dashed outline), and the reconnect with its usual backoff. The live trends’ “Live link down” span starts at the last frame received, not 20 s later. A page served by an older server, which sends no heartbeat, is never timed out. A link that goes silent (eaxScada a76eacef) - New: the
HEARTBEATmessage of the live data socket,{"type": "HEARTBEAT", "every_ms": 5000}, sent every 5 s on every socket, whatever else the socket gets, and also when its send queue is full. The page’s client takes the time it may stay silent fromevery_ms: 20 s, or 4 intervals when the server’s interval is longer. The eventscada:disconnectedof a silent socket carriesdetail.since, the time of its last frame. A page from before this release dispatches the message asscada:heartbeatand ignores it. HEARTBEAT (eaxScada a76eacef) - SAFETY: the Studio’s Trends draws the history logged during an outage inside the band. Trends reads the history again at each refresh (every 5 s by default), and that read holds the samples the server logged while the browser’s link was down. They are now drawn as recorded inside the grey band: lines, held values and Bad bands. The band stays, and the parts of the span that no logged sample covers keep no line or held value: nothing is held across them from the last sample before the outage. With 939 alone they were lone dots in the band. Screen trends and the classic dashboard trend card read no history again: they keep the rules of 939. When the live link goes down (eaxScada a76eacef)
- Upgrade notes (what now behaves differently):
- Every
/wssocket receives aHEARTBEATframe every 5 s. A client of the socket that refuses unknown message types must accept it. - A socket silent for 20 to 24 s after a heartbeat is closed by the page (code4000, “no heartbeat”) and opened again, with GATEWAY OFFLINE, stale values and “Live link down” on the live trends, as when the socket closes. -scada:disconnectedmay carrydetail.since. - Browser tabs opened before the upgrade do not detect a silent link until they are reloaded (After an upgrade: reload open tabs). - Unchanged: a socket that closes is seen as down at once, as before; the tag messages and the socket’s limits.
Remote access reports why the site ended a session (29 November, eaxScada merge 762696d1; every edition with remote access from eaxCloud):
- The last messages of each remote session reach eaxCloud when every remote-access switch is turned off. Turning off the last switch ends the sessions and closes the remote-access connection. The connection is now flushed before it closes, so each session’s last messages reach eaxCloud: the BYE to the remote person’s browser and the CLOSE for the relay, both with the reason. Before, the last of them could be lost as the connection closed, and the relay and the person working remotely did not learn why the session ended. No new message is sent. When the site ends a session (eaxScada 86f6fbcf)
- A session the site ends is reported with its cause. A session ended because the switches are off is reported as
switch_off(“The site turned remote access off.”), one ended while End remote sessions blocks remote access aslocal_end(“The session was ended at the site.”).revoked(“Remote access for this node was revoked.”) is kept for a site that is no longer enrolled, or was enrolled again as another site or node. Before, a session ended by the server’s periodic check of these conditions, rather than by the switch change itself, was always reported asrevoked. When the site ends a session (eaxScada 08c63e95) - Upgrade notes (what now behaves differently):
- Stopping the remote-access connection can take up to 500 ms longer, in the worst case: the flush waits at most 500 ms, and the connection then closes whether it completed or not.
- A session that the periodic check ended was reported, and recorded in its
REMOTE_SESSION_ENDEDrecord, with the reasonrevoked. It now hasswitch_offorlocal_end, as when the switch change or End remote sessions ends it. - Unchanged: when sessions end, which switches end which sessions, and the 60-minute block after End remote sessions.
Loops of any number of eaxTags scripts are warned (29 November, eaxScada merge 090c517e; every edition; safety: values operators see). With 931, only two scripts whose values read each other directly were warned:
- SAFETY: a loop of three scripts or more is warned on save and in the scripts’ status, as a two-script loop is. A’s value computed from C’s, C’s from B’s and B’s from A’s latch Bad the same way: once one goes Bad, the scripts keep each other Bad after the cause is gone. Each script of the loop shows one amber warning, “N scripts read each other’s values in a loop: …”, naming the scripts along the loop from the lowest id, the values each writes on it and the scripts that read them, and suggesting
{from: [...]}. The save’s answer carries it inwarnings; the save is not refused. A long loop names at most 10 scripts, then “and N more scripts”; a script past those finds its own part at the end. Scripts that read each other in a loop (eaxScada 7c0b3b6b) - SAFETY: a two-script loop through two values of each is now warned. For example, B’s
Ycomputed from A’sX, A’sPfrom B’sY, B’sQfrom A’sPand A’sXfrom B’sQ: no two values read each other, and it was not reported. Loops that share a value are one loop, with one warning; two loops that share a script but no value stay two warnings, one per line. The two-script text is unchanged. Scripts that read each other in a loop (eaxScada 7c0b3b6b) - The Studio says when a script saves with warnings, and marks those scripts in the list. The save shows an amber toast “Saved with N warnings: script id. Details under its status.” instead of the green “saved and started” one, and the status scrolls into view. Each script with a warning gets an amber accent and a marker with the count, which selects the script and focuses its warnings. A chip “N warnings” above the list shows only those scripts; a second click shows all. No banner. The texts are in the Studio’s language (English, French, German, Spanish, Italian). Scripts that read each other in a loop (eaxScada 7c0b3b6b, 73e1e259)
- Upgrade notes (what now behaves differently):
- Scripts that saved without a warning may now show one at their next save or status read: those on a loop of three scripts or more, or on a two-script loop through two values of each.
- A script can carry several loop warnings in
warningsand instatus[].warning, one per loop, each on its own line. - Unchanged: no save is refused for a loop, the scripts run as before, and the two-script warning text is the same.
A reopened live data socket reads the link up only when data arrives (29 November, eaxScada merge e957fe78; every edition; safety: values operators see):
- SAFETY: after a page has seen a heartbeat, a reconnected live data socket shows the link online only at its first frame. Then, and not at the socket’s open, GATEWAY OFFLINE goes away,
scada:connectedis sent and the views are subscribed again. Before, a socket that opened and delivered nothing (the remote access relay over a dead link) hid GATEWAY OFFLINE at once and set the gauges’ link flag while no value arrived, and as it had no heartbeat of its own yet it was never timed out: the link read online for about 20 s, until the remote session ended. A reopened socket that delivers nothing (eaxScada e3519f4c) - SAFETY: a reconnected socket is timed out 20 s from its open. A socket that delivers nothing is dropped 20 to 24 s after it opened, on the same two checks as 942, with no second
scada:disconnected. (eaxScada e3519f4c) - The reconnect backoff no longer starts over on a socket that delivers nothing. It starts over only when the link reads up, so a page keeps backing off (1 s, growing to at most 5 s) instead of trying again every second. (eaxScada e3519f4c)
- Upgrade notes (what now behaves differently):
- After a reconnect, GATEWAY OFFLINE stays up, and
scada:connectedcomes, until the first frame on the new socket, normally at once (ALARM_INIT). A client that listens forscada:connectedgets it at that frame, not at the open. - A page’s first socket behaves as before: online at its open, not timed out before its own heartbeat (the page may come from an older server that sends none). - The eaxCloud side of the remote-access case, which opens a remote page’s socket only once the site has accepted it, comes with the next eaxCloud release (eaxCloud: Changes).
Gauges and quality markers follow the live link only (29 November, eaxScada merge a2d9b3df; every edition; safety: values operators see). With 953, a reconnected live data socket is open for a moment before the link is up, until its first frame:
- SAFETY: a gauge shows the live link as up only when the page’s live data link (
hmiBus.connected) says it is up. While the link is not confirmed up, a reconnected socket before its first frame included, a gauge shows its last value dimmed and labelled NO LINK - STALE (NO DATA when it holds no value). The first frame on the socket reads the link up, and the gauge shows its value as live again. Before, a gauge also took an open socket for a live link: a page whose first gauge appeared while a reconnected socket was open and had delivered nothing drew that gauge’s last value as live, until the next change of the link. Gauges show quality on their face (eaxScada be8b67ce) - SAFETY: the quality markers mark the values on screen stale whenever the page’s live data link is not up. Every live object gets the dashed outline, and keeps it until the link is up and the snapshot of its tags is in, as after a close. Before, the markers also took an open socket for a live link: before they had seen a change of the link, values shown while a reconnected socket was open and had delivered nothing were not marked stale; and their check every half second for a missed close did not see a link down while its socket was open. Show bad and stale values (eaxScada be8b67ce)
- Fix: the Studio’s violet selection is readable in the light theme. The selected eaxTags script, the new-script row, the open Local tags card and the LOCAL chip had a muddy purple fill in the light theme: the script’s details read at 1.68:1 and its amber warning marker at 1.60:1. They now have a light violet fill with a violet edge, and every text on them reads at 5.3:1 or more (WCAG AA). The dark theme is unchanged. (eaxScada f6596d29)
- Upgrade notes (what now behaves differently):
- SAFETY: after a reconnect, until the first frame on the new socket (normally at once,
ALARM_INIT), a gauge that appears shows NO LINK - STALE, and values the quality markers had not yet marked get the dashed outline. Before, they could show their last values as live in that moment. - A screen script or HTML widget that judges the link from the socket (hmiBus.ws.readyState) should readhmiBus.connected, or the eventsscada:connectedandscada:disconnected: a reconnected socket is open before the link is up. - In the light theme, the selected eaxTags script, the new-script row, the open Local tags card and the LOCAL chip are light violet with a violet edge instead of dark purple. - Unchanged: a page’s first socket (online at its open), the gauges’ faces and labels, the markers and their order, pages without a live link (print views: never marked stale for the link), and the dark theme.
The same release also contains changes made earlier in October that need a check before production: tag reads follow the read permissions (a role without a subscribe rule reads no tags), and the Modbus TCP data types and byte order are fixed (an Int32 setpoint used to reach the device as float bits). Their full upgrade steps are in the release notes delivered with the release.