Enter downtime reasons
Say why each machine stopped, so the downtime Pareto and the OEE reports show real causes.
You need production_view to see the panel, production_reason to enter reasons while the shift is open, and production_reason_closed to change them after it closed. Entering a reason never writes to the machine.
1. Open the Downtime panel
Section titled “1. Open the Downtime panel”In the operator runtime, choose Downtime in the toolbar. The button is shown only when you hold production_view and the server lists at least one machine you may read; otherwise it stays hidden. A screen can also open the panel with a button whose action is Open downtime panel (step 6).
The panel opens on the right (full width below 1024 px). Escape closes the topmost dialog of the panel, then the panel.
2. Read the state and the shift
Section titled “2. Read the state and the shift”- Machine: only the machines whose every source tag you may read are offered.
- Stops of: This and the previous shift (default), This shift, Previous shift, Last 24 hours, Last 7 days.
- Current state and shift OEE: the state now and for how long, the shift with its start, and Availability, Performance, Quality and OEE with the quality of the data behind them. Provisional means the shift is still running and the numbers change. A figure that cannot be computed shows “No data”, never 0 %.
- Two tabs share one container: Stops (the grid) and Timeline (the machine’s states over time), with Split on a wide screen. Zooming the timeline filters the stops to that window; the chip “Time window …” says so, and choosing it shows the whole range again.
Short stops (micro-stops, under 120 s by default) are not listed: they count against performance, and no reason is asked.
3. Find the stops without a reason
Section titled “3. Find the stops without a reason”A stop without a reason is marked in the grid with Reason needed (amber accent and a marker). The chip above the grid filters to the marked stops: it says N without reason when every marker is a missing reason, else N to check. Choosing the marker opens its card with Set reason. The grid has filters per column, sorting, a quick filter and CSV export; an ongoing stop says “ongoing” with its running duration.
Automatic reasons: shown, not yet counted
Section titled “Automatic reasons: shown, not yet counted”When the machine reported a cause as it stopped (its fault code or an alarm), the Reason column shows that cause with an amber automatic tag in front, in italics. The row carries the amber marker Automatic reason; its card says: “It is not the stop’s reason until someone confirms it: until then OEE counts the stop without a reason.”
So an automatic reason is a suggestion:
- the stop still counts as without a reason, in OEE and in the panel’s count of stops without a reason;
- to confirm it, choose Set reason and tap it under Suggested from the machine: (step 4), or pick another reason if it is wrong.
Once the reason is in force, the amber tag goes. One exception: a machine set to Use the machine’s suggestion as the reason without an operator’s confirmation (see OEE and downtime) takes the machine’s cause as the reason in force at once. That reason is shown in normal text with a plain, non-amber automatic tag, and it counts as a reason.
Provisional stops
Section titled “Provisional stops”A stop the server is still computing (the ongoing stop, or one that ended in the last few seconds) has an amber Provisional tag at the start of its State cell and a Provisional marker. Its end, its duration and its reason can still change. A stop that ends shorter than the machine’s micro-stop time becomes a micro-stop and leaves the list.
What the CSV holds
Section titled “What the CSV holds”CSV exports the rows as filtered and sorted. Besides the shown columns it always adds Machine, End, Automatic reason, Comment and Entered by, even when they are hidden on a narrow screen. The column names follow the language of the panel:
- Reason: the code of the reason in force; empty while the stop has only an automatic reason.
- Automatic reason: the code the machine reported at the stop’s start, or in the 2 s after it; empty when it reported none. It stays filled after someone confirms or replaces the reason, so you can compare the two.
- Start and End: full ISO 8601 instants; End is empty for an ongoing stop. Duration (s): the duration in seconds.
4. Set or change a reason
Section titled “4. Set or change a reason”- Choose Set reason (or Change) in the row’s action column.
- Pick a category, then the reason (or type in Search reasons…; Recently used here: lists this machine’s recent reasons). Only the reasons offered for this machine’s group can be chosen.
- If the machine suggested a reason (from its fault code or an alarm), it is shown first under Suggested from the machine:. It is not selected for you: tap it if it is right.
- Comment: optional, required when the reason says so. At most 1,000 characters.
- When you change a reason, give the Reason for change (one line, at most 500 characters).
- Save. “Reason saved.” confirms it; “Recorded. It shows once the server has applied it.” means the record is written and the stop picks it up a moment later.
The reason is recorded first in the audit trail. If the trail cannot write, “Not saved: the audit trail could not be written. Nothing was changed.” appears and nothing changed. A reason marked planned makes the stop planned downtime: it no longer lowers availability.
Clear removes an operator reason (with a reason for change); the cleared reason stays in the stop’s history. History lists every record of the stop: who set or changed what, when, with the signature after close.
5. After the shift closed: sign the change
Section titled “5. After the shift closed: sign the change”A shift is closed for reasons a number of hours after it ends (8 by default, under Settings of the Production tab). After that, changing a reason, or entering a missing one, needs production_reason_closed and your e-signature:
- The dialog says “This shift is closed for reasons. The change alters reviewed numbers: it needs your e-signature.”
- Signer shows you, the signed-in user, read-only. Type your Password and the Reason for change: both start empty.
- Sign and save (or Sign and clear). The server checks the password over exactly this change and records the signature with the meaning Changed after shift close. If the reason, the comment or the stop changed since you signed, sign again.
Without production_reason_closed the panel says “You may not change reasons after the shift closed.”
6. Open the panel from a screen
Section titled “6. Open the panel from a screen”In the designer, select a button (or any object), open its Action tab and choose Open downtime panel. The action is offered only when the server’s licence includes OEE and downtime. Machine id (optional) opens the panel on that machine; empty, the panel chooses. It is navigation only: nothing is written. A machine the operator may not read is not shown, and where the panel is not available the runtime says “The downtime panel is not available here.” The action is stored as {"type": "open_downtime", "machine": "<id>"}.
If something is refused
Section titled “If something is refused”| The panel says | Why |
|---|---|
| “This server is an HA standby: enter reasons on the primary.” | Reasons are written on the HA primary only. |
| “This server cannot reach the other HA nodes: reasons cannot be saved right now.” | The primary has no quorum. |
| “OEE and downtime needs the Pro or Enterprise edition on this server.” | The licence does not include it, or capture is paused after a downgrade (reading still works). |
| “This session may only view OEE and downtime.” | An API token or the AI co-pilot: they never enter reasons. |
| “OEE and downtime is not available in a remote session.” | Remote sessions are never served. |
| “This stop started before the first computed state of the machine: a reason cannot be set for it.” | The stop is older than the machine’s first result. |
| “The stop changed meanwhile. Close the dialog and try again.” | A recompute or another person changed it. |