Skip to content

Runtime metrics and health snapshot

eaxPLCReferenceFreeProEnterpriseView as Markdown

Migrated page, not yet verified against the current code. Treat values, paths and examples as indicative until this notice is removed.

The eaxPLC runtime (plc-server, plc-runtime) reports its health in two forms that carry the same values:

  • GET /metrics: the Prometheus text format (version 0.0.4), for a Prometheus server or any compatible scraper.
  • GET /api/metrics/snapshot: a compact JSON snapshot with a versioned schema. Like every /api/ route, it is also served on the PLC’s NATS API (plc.<id>.api). eaxScada’s System Health workspace reads it there, so it needs no HTTP path to the PLC.

Both are in every edition.

Counters count from the runtime’s start. They restart at 0 when the runtime restarts; Prometheus rate() and increase() handle that. Fieldbus device counters also restart when a fieldbus configuration is applied.

Neither endpoint adds work, a lock or an allocation to the scan:

  • The values the scan produces are read with atomic loads: the latency histogram, the cycle, overrun and force counts. They are never read under the lock the scan records its statistics with.
  • Go runtime values come from runtime/metrics, which does not stop the world. runtime.ReadMemStats, which does, is not used.

A scrape takes about 70 µs on another goroutine and allocates about 15 KB.

Endpoint Who may call it
GET /metrics Any valid session or PLC token: the same rule as GET /api/stats. Anonymous only with --metrics-anonymous-localhost, and only from the loopback interface.
GET /api/metrics/snapshot Any valid session or PLC token, over HTTP or NATS. Never anonymous.

/metrics sits outside /api/ by Prometheus convention, but the runtime guards it like an /api/ read. Any other method than GET or HEAD is refused: 403 below the engineer level, 405 for an engineer.

--metrics-anonymous-localhost (off by default) lets a scraper on the same machine read /metrics without a token:

  • A request whose remote address is not loopback still needs a token.
  • A request carrying X-Forwarded-For (relayed by a local proxy) still needs a token.
  • The option never opens /api/metrics/snapshot or any other route.

For a remote Prometheus, mint a token at the lowest role and give it to the scraper as a bearer credential. PLC tokens are valid for 720 hours at most, so renew it before it expires.

Terminal window
plc-server token mint -user prometheus -role Compliance_Auditor -ttl 720h > /etc/prometheus/eaxplc.token
scrape_configs:
- job_name: eaxplc
scrape_interval: 15s
authorization:
type: Bearer
credentials_file: /etc/prometheus/eaxplc.token
static_configs:
- targets: ['plc-01.plant.local:8085']

Every eaxplc_ series carries the label plc_id (--plc-id). The other labels are bounded: no tag or user names. Units are seconds and bytes.

Metric Type Labels Meaning
eaxplc_build_info gauge version, goversion Always 1; the labels carry the build.
eaxplc_start_time_seconds gauge Unix time the runtime started.
eaxplc_uptime_seconds gauge Seconds since start.
eaxplc_running gauge 1 when the PLC scans its program (not stopped, not faulted).
eaxplc_paused gauge 1 when the PLC is in STOP.
eaxplc_faulted gauge 1 when a program fault or a watchdog trip put the PLC in STOP.
eaxplc_target_frequency_hz gauge Target scan frequency.
eaxplc_program_version gauge Version number of the running program (+1 per deploy since start).
eaxplc_scan_cycles_total counter Scan cycles run.
eaxplc_scan_overruns_total counter task Cycles longer than 110 % of the period.
eaxplc_watchdog_trips_total counter Overrun watchdog trips.
eaxplc_scan_duration_seconds histogram task Program execution time per cycle.
eaxplc_scan_jitter_seconds histogram task Period error per cycle: |actual period − target|.
eaxplc_scan_jitter_quantile_seconds gauge task, quantile (0.5, 0.95, 0.99) Jitter quantiles over the last 10 s. NaN when no cycle ran in the window.
eaxplc_scan_duration_quantile_seconds gauge task, quantile (0.5, 0.95, 0.99) Execution time quantiles over the last 10 s.
eaxplc_scan_jitter_max_seconds gauge task Largest jitter since start.
eaxplc_scan_duration_max_seconds gauge task Longest execution since start.

task is main: the real-time loop.

The two histograms have buckets at 1, 2, 5, 10, 20, 50, 100, 200 and 500 µs, then 1, 2, 5 and 10 ms. Their _sum is exact.

The histograms only grow. POST /api/stats/latency/reset clears what /api/stats/latency shows, but not these.

The quantile gauges are estimated from the bucket counts of the last 10 s, by linear interpolation inside a bucket. For quantiles over another window, use histogram_quantile() on the histograms.

Metric Type Meaning
eaxplc_dvr_enabled gauge 1 when the recorder is enabled (--enterprise).
eaxplc_dvr_recording gauge 1 while it records.
eaxplc_dvr_epoch gauge Cycle counter epoch of the newest recorded cycle: +1 each time the cycle counter restarts.
eaxplc_dvr_recorded_cycles_total counter Cycles recorded.
eaxplc_dvr_lost_cycles_total counter Cycles missing from the recording (gaps). Alert on any increase.
eaxplc_dvr_disk_blocks_dropped_total counter Closed blocks not written to disk because the writer was behind (--audit-disk).
eaxplc_dvr_memory_bytes gauge Memory the recording holds.
eaxplc_dvr_memory_limit_bytes gauge Its cap (--dvr-max-mb).
eaxplc_dvr_retained_seconds gauge History the recording holds.
eaxplc_telemetry_queue_dropped_total counter Cycles the scan could not queue to the recorder because the queue was full.
eaxplc_websocket_open gauge Telemetry WebSockets (/api/telemetry) open now.
eaxplc_websocket_refused_total counter Telemetry WebSockets closed with 1008 by a concurrent socket cap, by reason: per_session (--ws-max-per-session) or per_ip (--ws-max-per-ip).
Metric Type Labels Meaning
eaxplc_forces_active gauge Forced locations.
eaxplc_writes_total counter result One-shot write requests (POST /api/write, over HTTP or NATS).
eaxplc_deploys_total counter result (ok, compile_error) Program deploys.
eaxplc_rollbacks_total counter result (ok, failed) Program rollbacks.

Each result of eaxplc_writes_total counts one request, whatever the number of entries in it:

result Meaning
ok Queued for the next scan.
rejected Invalid request (400).
denied The caller lacks the plc.write right (403).
refused_forced A target is forced (409).
failed Could not be queued.

Requests refused before authentication (401) are not counted.

Metric Type Meaning
eaxplc_nats_configured gauge 1 when the runtime serves its API on a broker (--nats).
eaxplc_nats_connected gauge 1 while the broker connection is up.
eaxplc_nats_reconnects_total counter Broker reconnections.

There is one series per configured device. The labels are bus (bus id), type (modbus_tcp, ethernet_ip, ethercat) and device (device id). The series exist only when a fieldbus is configured.

Metric Type Meaning
eaxplc_fieldbus_device_up gauge 1 while the device exchanges I/O.
eaxplc_fieldbus_cycles_total counter Good I/O cycles.
eaxplc_fieldbus_bad_cycles_total counter Failed I/O cycles that had not yet faulted the device (see below).
eaxplc_fieldbus_faults_total counter Transitions of the device to fault.
eaxplc_fieldbus_last_cycle_seconds gauge Duration of the device’s last measured I/O cycle.

What counts as a bad cycle depends on the bus type:

  • EtherCAT: no frame came back, or the working counter was wrong.
  • Modbus TCP: an exception or error answer.
  • EtherNet/IP: input data more than half the watchdog late.

These series exist only while the server runs (not with --no-modbus).

Metric Type Labels Meaning
eaxplc_modbus_server_up gauge 1 while the server listens.
eaxplc_modbus_server_requests_total counter kind (read: FC 1–4, write: FC 5, 6, 15, 16, other) Requests served.
eaxplc_modbus_server_snapshot_reads_total counter Of the reads, those answered from the last cycle’s copy, without waiting for a scan.
eaxplc_modbus_server_exceptions_total counter Requests answered with an exception.
eaxplc_modbus_server_connections gauge Open connections.
eaxplc_modbus_server_connections_total counter Connections accepted.

These use the usual Prometheus Go names, without plc_id.

Metric Type Meaning
go_info gauge Go version (version label).
go_goroutines gauge Goroutines.
go_memstats_heap_alloc_bytes gauge Heap bytes in live and unswept objects.
go_memstats_sys_bytes gauge Memory mapped by the Go runtime.
go_gc_cycles_total counter Completed garbage collections.
go_sched_gomaxprocs_threads gauge GOMAXPROCS.
eaxplc_gc_pause_seconds histogram Stop-the-world GC pauses. The scan stops during them too.

eaxplc_gc_pause_seconds has buckets from 10 µs to 100 ms. It is folded from the runtime’s own histogram, so its _sum is estimated from bucket midpoints.

The snapshot is the request GET /api/metrics/snapshot on the PLC API subject:

Subject plc.<plc-id>.api (request/reply)
Envelope shared/plcapi: {"m":"GET","p":"/api/metrics/snapshot","h":{"Authorization":["Bearer <PLC token>"]}}
Reply {"s":200,"h":{...},"b":"<base64 JSON body>"}
Over HTTP GET /api/metrics/snapshot with the same credential

From Go, plcapi.Do(requester, plcID, plcapi.Request{Method: "GET", Path: "/api/metrics/snapshot", Header: ...}, timeout) returns the decoded response.

The body is about 1.5 KB with two fieldbus devices.

A caller may send X-Request-ID (1 to 64 characters of A-Z a-z 0-9 . _ : -). The runtime then logs the request under that id and echoes it in the reply header. Without one, the runtime makes an id: r- over HTTP, n- over NATS.

Every field is always present. Adding a field keeps the schema name. A field renamed, removed or changing meaning gives a new name (eaxplc.metrics.v2). Readers must ignore fields they do not know.

Field Type Meaning
schema string eaxplc.metrics.v1
plc_id string --plc-id
version string Runtime build version.
ts_ms integer Unix time of the snapshot, ms.
uptime_s number Seconds since start.
scan.state string running, stopped or faulted.
scan.target_hz integer Target scan frequency.
scan.program_version integer Running program’s version number.
scan.cycles_total integer Cycles since start.
scan.overruns_total integer Overrun cycles since start.
scan.watchdog_trips_total integer Overrun watchdog trips.
scan.window_s number Length of the quantile window, normally 10 s (shorter just after start).
scan.window_cycles integer Cycles in the window.
scan.jitter_p50_us, scan.jitter_p95_us, scan.jitter_p99_us number or null Jitter quantiles over the window. Null when no cycle ran in it.
scan.exec_p50_us, scan.exec_p99_us number or null Execution time quantiles over the window.
scan.jitter_max_us, scan.exec_max_us number Maxima since start.
dvr.enabled, dvr.recording boolean Recorder state.
dvr.epoch, dvr.last_cycle integer Newest recorded cycle: epoch and cycle number. Together they name a cycle in the DVR timeline.
dvr.recorded_total, dvr.lost_total integer Cycles recorded and lost.
dvr.memory_bytes, dvr.memory_limit_bytes integer Recording memory and its cap.
dvr.retained_s number History held.
dvr.disk_blocks_dropped_total integer Blocks not written to disk.
forces_active integer Forced locations.
writes.ok, .rejected, .denied, .refused_forced, .failed integer One-shot write requests by result.
deploys.ok, .failed, .rollback_ok, .rollback_failed integer Deploys and rollbacks by result.
nats.configured, nats.connected boolean Broker connection.
nats.reconnects_total integer Broker reconnections.
fieldbus[] array One entry per bus, its devices summed. Empty when no fieldbus is configured.
fieldbus[].bus, .type string Bus id and type.
fieldbus[].devices, .healthy integer Devices, and those exchanging I/O.
fieldbus[].cycles_total, .bad_cycles_total, .faults_total integer Good and bad I/O cycles, transitions to fault.
fieldbus[].last_cycle_max_us number Longest last-measured I/O cycle among the devices.
modbus_server object or null Null when the Modbus TCP server is off.
modbus_server.read_requests_total, .write_requests_total, .other_requests_total, .exceptions_total integer Requests by class, and exceptions.
modbus_server.snapshot_read_requests_total integer Of read_requests_total, the reads answered from the last cycle’s copy, without waiting for a scan.
modbus_server.connections integer Open connections.
go.goroutines, go.heap_bytes, go.total_bytes, go.gc_cycles_total integer Go runtime.
go.gc_pause_max_us number Upper bound of the largest GC pause bucket reached since start.
telemetry.queue_dropped_total integer Cycles not queued to the recorder.
telemetry.ws_open, telemetry.ws_refused_per_session_total, telemetry.ws_refused_per_ip_total integer Telemetry WebSockets open, and refused by each socket cap since start.

Example (plc-server, two fieldbus devices not reachable):

{
"schema": "eaxplc.metrics.v1", "plc_id": "obs-test", "version": "0.0.0-dev",
"ts_ms": 1790922524585, "uptime_s": 60.35,
"scan": {"state": "running", "target_hz": 1000, "program_version": 1, "cycles_total": 60158,
"overruns_total": 27, "watchdog_trips_total": 0, "window_s": 10.95, "window_cycles": 10949,
"jitter_p50_us": 0.52, "jitter_p95_us": 0.98, "jitter_p99_us": 4.96,
"exec_p50_us": 3.05, "exec_p99_us": 8.98, "jitter_max_us": 1557.3, "exec_max_us": 421.7},
"dvr": {"enabled": true, "recording": true, "epoch": 0, "last_cycle": 60158, "recorded_total": 60158,
"lost_total": 0, "memory_bytes": 1120240, "memory_limit_bytes": 268435456, "retained_s": 60.16,
"disk_blocks_dropped_total": 0},
"forces_active": 0,
"writes": {"ok": 0, "rejected": 0, "denied": 0, "refused_forced": 0, "failed": 0},
"deploys": {"ok": 0, "failed": 0, "rollback_ok": 0, "rollback_failed": 0},
"nats": {"configured": false, "connected": false, "reconnects_total": 0},
"fieldbus": [
{"bus": "mb-plant", "type": "modbus_tcp", "devices": 1, "healthy": 0, "cycles_total": 0,
"bad_cycles_total": 0, "faults_total": 11, "last_cycle_max_us": 0},
{"bus": "eip-drives", "type": "ethernet_ip", "devices": 1, "healthy": 0, "cycles_total": 0,
"bad_cycles_total": 0, "faults_total": 0, "last_cycle_max_us": 0}
],
"modbus_server": {"read_requests_total": 0, "snapshot_read_requests_total": 0, "write_requests_total": 0, "other_requests_total": 0,
"exceptions_total": 0, "connections": 0},
"go": {"goroutines": 52, "heap_bytes": 3738648, "total_bytes": 14585856, "gc_cycles_total": 3, "gc_pause_max_us": 0.064},
"telemetry": {"queue_dropped_total": 0, "ws_open": 1, "ws_refused_per_session_total": 0, "ws_refused_per_ip_total": 0}
}

The runtime logs through one structured logger, Go’s log/slog:

  • Console (stderr): text by default, or JSON lines with --log-format json (for a container log collector).
  • Log file: always JSON lines. plc-server writes logs/eaxPLC.log and plc-runtime writes logs/eaxPLC-rt.log. The file rotates at 20 MB and five files are kept.
  • Level: --log-level debug|info|warn|error (default info).

Every line carries time, level, msg, plc_id and component. The components are main, runtime, http, deploy, executor, codestore, gitstore, nats, fieldbus, watchdog, auth, dvr, modbus, opcua, uns, telemetry, eaxtags, attach and metrics.

These correlation fields are added where they apply:

Field Where
request_id Lines logged for an API request, over HTTP or NATS: deploys, rollbacks, fieldbus changes, authentication errors. The same id is in the X-Request-ID response header.
deploy_id Deploy and rollback lines. It is also returned in the deploy or rollback response (deploy_id).
cycle, dvr_epoch Program swaps, scan faults and watchdog trips. They name the cycle in the DVR timeline.
audit_seq Lines saying that an audit record was written. The log refers to the audit record by its sequence number and never copies its content.

The logger never writes secrets:

  • Attributes whose name means a secret are replaced by [REDACTED]: token, password, secret, signature, seed, NKey, authorization, cookie, API key.
  • Free text is scrubbed before it is written: messages, errors, URLs and JSON bodies. The scrubber removes PLC tokens (v1.…), JWTs, NKey seeds, Bearer credentials, user:password@ in URLs and secret query parameters.