Genealogy retention, purge and archives
Keep genealogy records as long as your regulations and customers require, and no longer. By default nothing is ever removed. A purge removes only what is past its retention, only after the records are archived and the archive is verified, and only with a signature.
Before you start
Section titled “Before you start”- A recovery key set up in the backup settings (Set up backups), and its private file, downloaded when the key was made, kept somewhere safe. Without the key a purge is refused; without the private file the archives cannot be read.
- An Administrator, on site, to set the retention.
- A Process_Supervisor or above, with
genealogy.write, on site, to run the purge. - On a high availability pair: the purge runs on the primary.
1. Set the retention per unit type
Section titled “1. Set the retention per unit type”Open Genealogy > Retention and purge. The Retention by unit type grid lists each unit type with Kept for (Forever by default).
- Choose Set on a type and enter a period of at least 365 days: years (
10y, a year counted as 365 days) or days (3650d). Keep forever removes the period. - Choose Save settings (Administrator, on site only). The change applies at the next start of eaxScada.
The retention is stored in data/genealogy/settings.json:
{ "retention": { "gearbox": "15y", "drive-module": "15y", "resin": "10y" }}A type left out is kept forever. With no retention at all, a purge is refused (NO_RETENTION).
On a high availability pair, set the same retention on both servers. data/genealogy/settings.json (retention, ack_durability, the export, pseudonymisation) is per server and not replicated: after a failover, the new primary purges with its own file.
2. What a purge removes
Section titled “2. What a purge removes”A purge removes whole groups of linked units only: a unit, its components, what it was built into, and theirs. A part is never purged while the product it went into is kept.
A group is purged only when every unit in it has a retention, and its newest record is older than the longest retention in the group by plant time AND by recording time:
- plant time is when the event happened on the line;
- recording time is when eaxScada recorded it.
Example: a legacy import. In November 2026 you import gearboxes built in 2012 from an older system, with a retention of 10y. By plant time they are already 14 years old, but by recording time they are new. They are kept until November 2036: the retention counts from the day they were imported.
- Retention by plant time
- Retention by recording time
- Kept
- Moment
- Purge refused: kept
Read as text
Gearboxes built in 2012 are imported in November 2026 with a retention of 10 years. By plant time their retention would have ended in 2022, but by recording time it starts in November 2026. A purge needs the newest record past the retention on both clocks, so the group is kept until November 2036.
Plant time: when it happened on the line
- Gearboxes built: plant time: 2012 (built)
- Retention 10y: by plant time: 2012 to 2022
Recording time: when eaxScada recorded it
- Imported: recording time: Nov 2026 (imported)
- Retention 10y: by recording: to Nov 2036
The purge
- Kept: until Nov 2036, both past
- Purge: of the whole group (not yet; possible). A purge planned before November 2036 leaves the group: its newest record is not older than 10 years by recording time.
A purged unit refuses new records. Its serial number can later be created again, as a new unit.
3. Plan the purge (dry run)
Section titled “3. Plan the purge (dry run)”Choose Plan a purge (dry run). Nothing changes. The plan shows:
- Units to remove, Of which components, Records to remove, Unit types;
- the record number the plan was made at, and whether the job was cut to a size limit (the rest is left for a later purge);
- the retention in force, and a grid of the unit types with their unit counts (with Export CSV).
Check the counts against what you expect. A type with more units than expected usually means a retention that is too short.
4. Sign the purge
Section titled “4. Sign the purge”Choose Continue: sign the purge. The dialog says how many units and records will be removed, and that it cannot be undone in eaxScada: they remain only in the encrypted archive.
- You are the signer (the signed-in user, shown read only).
- Enter the Reason for the purge, such as “retention of 15 years reached for gearboxes built in 2011”, and Your password.
- Choose Sign and purge.
eaxScada then, in this order:
- writes the archive
data/genealogy/archives/genealogy-purge-<time>.eaxgenealogy, encrypted to the recovery key, reads it back and verifies it; - writes the audit record
GENEALOGY_PURGE(if it cannot, nothing is removed); - writes one signed PURGED record that removes the records and keeps a tombstone for each, so the chain stays verifiable.
Any failure before the PURGED record removes nothing, and is recorded as GENEALOGY_PURGE_REFUSED. Afterwards Verify also reports the tombstones and the purges.
A purge is refused:
| Refusal | Why |
|---|---|
PURGE_ON_SITE |
You are connected through remote access. A purge is run on site only. |
PURGE_ON_PRIMARY |
This server is not the primary of the pair. |
NO_RETENTION |
No retention is set (records are kept forever). |
NO_RECOVERY_KEY |
No recovery key in the backup settings. |
| busy | Another purge is running. |
5. Keep the archives
Section titled “5. Keep the archives”The Purge archives grid on the same tab lists each archive with its size and date. Download saves one (Administrator, on site only; each download is recorded as GENEALOGY_ARCHIVE_DOWNLOAD with its size and SHA-256). The same list is GET /api/genealogy/archives.
Back up data/genealogy/archives with the rest of data/genealogy: after a purge, the archive is the only copy of the removed records. Keep the recovery key’s private file as long as you keep the archives.
6. Restore and verify an archive
Section titled “6. Restore and verify an archive”Restoring never touches the live genealogy: it writes into an empty folder, which you then read or verify. The offline commands open genealogy folders for writing, so eaxScada must be stopped; while it runs they are refused with exit code 4.
eaxscada.exe genealogy restore --in "D:\archive\genealogy-purge-20361102T071523.523607100Z.eaxgenealogy" --into "D:\restored\genealogy" --recovery-key "E:\keys\eaxscada-recovery-key.txt" --workdir "C:\eaxware\eaxScada"eaxscada.exe genealogy verify --genealogy "D:\restored\genealogy" --workdir "C:\eaxware\eaxScada"The other offline commands:
| Command | Does |
|---|---|
genealogy verify |
Checks the whole chain (exit 0: whole; 3: breaks found) |
genealogy archive --from <YYYY-MM-DD> --to <YYYY-MM-DD> --out <file> |
Archives the records of those UTC plant days, encrypted to the recovery key, without removing them |
genealogy restore --in <file> --into <empty folder> --recovery-key <file> |
Writes an archive’s records into an empty folder, never the live one |
genealogy rebuild-index |
Rebuilds the trace index and the unit states from the records |
genealogy export-hive --out <folder> |
Writes the Parquet export (Export genealogy for analytics tools) |
Common flags: --workdir, --data, --genealogy, --config. Exit codes: 0 done, 1 failed, 2 usage, 3 breaks found, 4 the server is running. All flags: command line.
Verify
Section titled “Verify”- The audit trail holds
GENEALOGY_PURGEwith the counts, the archive name and its seal, signed by you. - The archive appears in Purge archives.
- A purged unit is no longer found by Search. Units in groups not yet past their retention, including any group with a linked unit whose type is kept longer, are still found.