# Alarm summary card

> The alarm summary dashboard card: the active alarms with their priority badges and an acknowledge button.

Product: eaxScada · Type: Reference · Editions: Starter
Source: https://eaxware.com/docs/eaxscada/reference/generated/widgets/dashboard-cards/card-alarm-summary/
Verified against commit 2a10ac7.

<!-- GENERATED by tools/docgen (node tools/docgen/docgen.mjs). Do not edit by hand: change the source and regenerate. -->

The active alarms on a card: priority badge, alarm, value and state, most urgent first, with an **ACK** button on each unacknowledged alarm and an **ACK VISIBLE (n)** button. It has no settings: it lists every active alarm the signed-in user may see, scrolling when they do not fit. For filters by area, class and priority, use the [alarm summary screen object](/docs/eaxscada/reference/generated/widgets/alarms/alarm-summary/).
[Image: Alarm summary card card]
|  |  |
|---|---|
| Card palette | Display Widgets › ISA-18.2 Alarms Summary |
| Card kind | `alarm_summary` (`body.widget`) |
| Default size | 5 × 4 grid cells |

:::caution[Safety-relevant]
Shows the standing alarms and can acknowledge them (alarm surface).
:::

## Settings

Double-click the card (or select it and press Enter) to open its settings. The settings are stored in the card's `body.params`.



## Actions

**ACK** opens the acknowledgement dialog for that alarm: the acknowledging user is the signed-in user (shown read-only) and the reason is required (it starts empty). **ACK VISIBLE (n)** acknowledges the n unacknowledged alarms the card shows (after the list's filter, never the hidden ones) in one dialog that names them; it is disabled at 0. Nothing is sent until the dialog is confirmed, and a refusal is shown in the dialog. In *Edit layout* and in the screen designer nothing is acknowledged.

## Quality and parameters

Values come with their quality: a Bad or Uncertain value is marked on the card, and a value not yet received shows a dash, never an invented number. A card on a screen with parameters takes `{Name}` in its tag paths.

## Examples

### Alarms next to the line's KPIs

The alarm card on a line dashboard, so the operator sees the alarms next to the values they concern.

1. Click **ISA-18.2 Alarms Summary** in the dashboard palette.
2. Resize it to 5 × 4 cells; title `Active alarms`.
[Image: Alarms next to the line's KPIs]

The four standing alarms of the test server.
## See also

- [Alarm summary (screen object)](/docs/eaxscada/reference/generated/widgets/alarms/alarm-summary/)
- [Alarms](/docs/eaxscada/explanation/alarms/)