# Driver channels, devices and tags

> Driver channels, devices and tags: every key, its type and meaning, generated from the Go structs that decode it.

Product: eaxScada · Type: Reference · Editions: Starter
Source: https://eaxware.com/docs/eaxscada/reference/generated/config/drivers/
Verified against commit 2ddbda1.

<!-- GENERATED by tools/docgen (node tools/docgen/docgen.mjs). Do not edit by hand: change the source and regenerate. -->

Driver configuration (data/drivers/config.json): channels, their devices and tag mappings, and the protocol settings object of each channel.

Keys are the JSON keys. **Optional** marks keys that are omitted when empty, or that may be absent (pointers).

## Channel

Channel represents a physical or logical communication channel (eaxDrivers Channel level)

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `id` | string |  |  |
| `name` | string |  |  |
| `description` | string |  |  |
| `protocol` | string |  | ETHERNET_IP, ISO_ON_TCP, MODBUS_TCP, etc. |
| `enabled` | boolean |  |  |
| `inter_request_delay_ms` | integer |  | ms delay between packets |
| `connect_timeout_ms` | integer |  |  |
| `request_timeout_ms` | integer |  |  |
| `retry_count` | integer |  |  |
| `settings` | JSON value |  | Protocol-specific settings JSON |
| `status` | [ChannelStatus](#channelstatus) |  |  |
| `last_error` | string | yes |  |
| `last_error_at` | timestamp (RFC 3339 string) | yes | in ERROR since (history: diagnostics) |
| `packets_sent` | integer |  |  |
| `packets_recv` | integer |  |  |
| `error_count` | integer |  |  |
| `last_rtt_ms` | number |  |  |
| `last_connected` | timestamp (RFC 3339 string) | yes |  |
| `devices` | list of [Device](#device) | yes |  |
| `simulated` | boolean |  | Simulated mirrors the Simulated flag inside Settings so the UI can show it without parsing protocol-specific settings. A simulated channel never touches the network and every tag under it is generated, which is indistinguishable from healthy live data unless it is surfaced. Derived server-side on read; never trust it from a request body. |
| `link` | [LinkStats](#linkstats) | yes | Link is the running driver's link-level diagnostics (frames, checksum errors, timeouts, node states) for the serial and CAN drivers. Derived on read; absent for drivers that do not report it. |
| `_rev` | string | yes | Rev is the revision of the channel's configuration: send it back in the If-Match header of a save (a stale one is refused with 409). Read only. |

## Device

Device represents a physical PLC, RTU, or endpoint under a channel (eaxDrivers Device level)

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `id` | string |  |  |
| `channel_id` | string |  |  |
| `name` | string |  |  |
| `description` | string |  |  |
| `station_id` | string |  | IP address, node number, slave address, or topic prefix |
| `model` | string |  | e.g. 1769-L33ER, S7-1516-3, Micro850, Generic Modbus |
| `scan_rate_ms` | integer |  |  |
| `enabled` | boolean |  |  |
| `block_read_optimization` | boolean |  |  |
| `max_block_size` | integer |  |  |
| `status` | [ChannelStatus](#channelstatus) |  |  |
| `last_error` | string | yes |  |
| `tag_count` | integer |  |  |
| `packets_sent` | integer |  |  |
| `packets_recv` | integer |  |  |
| `error_count` | integer |  |  |
| `tags` | list of [TagMapping](#tagmapping) | yes |  |
| `scan_measured_ms` | number | yes | ScanMeasuredMs (runtime, read only) is the measured time between two polls of the device (averaged), PollCycleMs how long its last poll took; both 0 until it was polled twice. A measured rate well above scan_rate_ms means the line or the controller cannot keep up. |
| `poll_cycle_ms` | number | yes |  |
| `uns_prefix` | string | yes | UNSPrefix is the ISA-95 path this device sits at, e.g. "Plant/Processing/BlendLoop". Protocols that carry less hierarchy than the UNS needs (Modbus carries none, CIP and Sparkplug carry equipment and signal) use it to build the suggested UNS path of a browsed tag. Without it the suggestion is only the part the device actually knows. |
| `plc_id` | string | yes | PLCID, optional, declares the device as the eaxPLC with this id (as configured on this server, e.g. "plc-01"). Active PLC forces are then shown on the device's tags by address, without guessing which PLC the device is. Empty: the device is not declared as an eaxPLC. |
| `simulated` | boolean |  | Simulated is inherited from the parent channel, surfaced here so a device row can be badged without the caller re-resolving the channel. |
| `_rev` | string | yes | Rev is the revision of the device's configuration (If-Match of a save). Read only. |

## TagMapping

TagMapping maps a device hardware address to a NATS-based Unified Namespace (UNS) tag path

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `id` | string |  |  |
| `device_id` | string |  |  |
| `channel_id` | string |  |  |
| `tag_name` | string |  | Hardware symbolic name or register |
| `address` | string |  | e.g. "HR:40001", "DB1.DBD0", "Program:Main.Speed", "ns=2;s=Temp" |
| `data_type` | string |  | Float32, Float64, Int16, Int32, UInt16, Bool, String |
| `access` | string |  | "RO" (Read Only: every write refused before it is sent, whoever asks), "RW" (Read / Write; also empty), "WO" (Write Only) |
| `deadband` | number |  | Value delta for publishing trigger |
| `eng_unit` | string |  | RPM, °C, bar, %, kW |
| `uns_path` | string |  | Core UNS path: "Plant/Processing/Reactor1/Temperature" |
| `nats_topic` | string |  | Auto-derived: "uns.telemetry.Plant.Processing.Reactor1.Temperature" |
| `live_value` | number |  |  |
| `quality` | integer |  | 192 = Good, 0 = Bad, 64 = Uncertain |
| `timestamp` | integer |  |  |
| `last_error` | string | yes | runtime: why the last read failed ("" after a good read) |
| `simulated` | boolean |  | The mapping's channel is simulated (derived from the channel; never a fallback for a disconnected device) |
| `live_text` | string | yes | LiveText (runtime) is a String mapping's last text read from the device (FINS, MC protocol: TextReader). Quality and Timestamp are its read's: a failed read keeps the text with quality BAD, never GOOD. The tag engine holds numbers, so the text is not in it. |
| `scale` | number | yes | Scale divides the raw value read from the device to produce the engineering value. Modbus transmitters send integers — a level in percent as value*100, a pump speed in rpm as value*10 — and the factor differs per signal because a single factor overflows a 16-bit register for large spans. Zero and one both mean "no scaling"; zero is the zero value of the field and must not be treated as "divide by zero". |
| `eng_min` | number | yes | Engineering range (instrument span), optional. A Good value outside it is published as Uncertain (EU exceeded), never as Good. |
| `eng_max` | number | yes |  |
| `esign_external` | boolean | yes | ESignExternal: an external writer - a NATS command, a non-session API caller, an AI agent - must sign every write to this tag (a person's e-signature or a registered integration's signature). The HMI keeps the screen policy. Founder decision 2026-10-01 (internal/writepolicy). |
| `write_range` | [Range](#range) | yes | WriteRange: the values a write to this tag may carry (min, max, step, allowed values; for a String tag max_length and allowed texts). The server refuses a write outside it, whoever sends it. Distinct from the engineering range, which only flags a read value's quality. |
| `handed_over` | [Handover](#handover) | yes | HandedOver: the mapping took its path over from a local tag ("Hand over to driver", handover.go). Set by the server only, never from a request; kept by every save on the same path. It holds the local definition "Return to local tag" puts back. |
| `_rev` | string | yes | Rev is the revision of the mapping's configuration (If-Match of a save). Read only. |

## EtherNetIPSettings

EtherNetIPSettings configures a CIP controller reached over EtherNet/IP: tag
reads and writes by name over a connected session. A Logix controller in a
chassis (or a compact one) is reached through the backplane ("1,&lt;slot&gt;"); a
controller with no backplane (the Micro family, controller\_type MicroCIP) is
reached with an empty route. With controller\_type DeviceCIP the connection
is an EtherNet/IP device instead (drive, I/O adapter): attributes by
class/instance/attribute, unconnected explicit messages, no route. With
controller\_type MicroLogixPCCC, SLC500PCCC or PLC5PCCC it is a PCCC
controller (MicroLogix, SLC 500, PLC-5): data-table addresses, PCCC
commands in unconnected messages, no route. Assembly I/O and implicit
(Class 1) connections are not supported.

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `host` | string |  | Controller (or Ethernet module) IP address, e.g. 192.168.1.50 |
| `port` | integer |  | Default 44818 |
| `slot` | integer |  | Controller slot in the chassis (route "1,&lt;slot&gt;"; 0 for a compact controller; not used by a controller with no backplane) |
| `cip_path` | string |  | Optional route that replaces the slot, e.g. "1,0" or a multi-hop "1,2,2,10.0.0.5,1,0" |
| `connection_type` | string |  | Kept for compatibility; not read by the driver (always a connected session) |
| `controller_type` | string |  | Controller family ("CompactCIP", "ModularCIP", "MicroCIP", "GenericCIP"), "DeviceCIP" for an EtherNet/IP device (drive, I/O adapter), or a PCCC controller ("MicroLogixPCCC", "SLC500PCCC", "PLC5PCCC": data-table addresses such as N7:0); selects the route (MicroCIP → empty route, no backplane). Empty is read as a backplane ("1,&lt;slot&gt;") controller, unchanged from before. |
| `auto_discover` | boolean |  | Kept for compatibility; not read by the driver |
| `simulated` | boolean | yes | Explicit simulator mode |
| `timeout_ms` | integer | yes | TimeoutMs bounds each request to an EtherNet/IP device (DeviceCIP) or a PCCC controller (ms, 100-30000). 0: 2000. Not read for a Logix controller. |

## ISOOnTCPSettings

ISOOnTCPSettings configures an S7-300/400/1200/1500 PLC over ISO-on-TCP
(RFC 1006, port 102): absolute addresses in DB, M, I and Q. An S7-1200/1500
needs PUT/GET access allowed and data blocks without optimized access.

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `host` | string |  | PLC IP address (e.g. 192.168.1.10) |
| `port` | integer |  | Default 102 |
| `rack` | integer |  | Default 0 |
| `slot` | integer |  | CPU slot: 1 for S7-1200/1500, 2 for S7-300 (0 takes the family default) |
| `plc_family` | string |  | "S7-1500", "S7-1200", "S7-300", "S7-400" (legacy "ISO-1500" etc. are read as these) |
| `pdu_size` | integer |  | Negotiated PDU (240 to 960) |
| `auto_reconnect` | boolean |  |  |
| `simulated` | boolean | yes | Explicit simulator mode |

## ModbusTCPSettings

ModbusTCPSettings configures Modbus TCP/IP Ethernet

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `host` | string |  | Gateway/PLC IP address |
| `port` | integer |  | Default 502 |
| `unit_id` | integer |  | Default 1 (Slave address) |
| `byte_order` | string |  | "ABCD" (Big-Endian), "CDAB" (Word-Swap), "BADC", "DCBA" |
| `max_block_size` | integer |  | Default 125 registers |
| `zero_based` | boolean |  | Address indexing starts at 0 or 1 |
| `simulated` | boolean | yes | Explicit simulator mode; the port is never used to infer it |
| `gateway` | boolean | yes | Gateway: the address is a Modbus TCP gateway with several devices behind it (meters, drives, RTUs on its serial side). Each device is a station whose station_id is its unit id (1-247); its reads and writes carry that unit id over the one connection, and a device without a station id uses UnitID. Off (the default, and every configuration saved before gateways existed): every request goes to UnitID and the station_id is not read. |
| `timeout_ms` | integer | yes | TimeoutMs bounds each request (ms, 100-30000). 0: 2000, as before; the channel's request timeout is not used for Modbus TCP. |
| `block_gap_registers` | integer | yes | BlockGapRegisters: with block reads on a device, the most unmapped holding or input registers one block read spans between two tags. Unset: 16; 0: only adjacent tags are read together. |
| `block_gap_bits` | integer | yes | BlockGapBits: with block reads on a device, the most unmapped coils or discrete inputs (bits) one block read spans between two tags. Unset: 64; 0: only adjacent tags are read together. |

## ModbusRTUSettings

ModbusRTUSettings configures Modbus Serial RTU

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `serial_port` | string |  | e.g. "COM3" or "/dev/ttyUSB0" |
| `baud_rate` | integer |  | 9600, 19200, 38400, 57600, 115200 |
| `data_bits` | integer |  | 7, 8 |
| `stop_bits` | integer |  | 1, 2 |
| `parity` | string |  | "N" (None), "E" (Even), "O" (Odd) |
| `slave_id` | integer |  | 1 to 247 |
| `byte_order` | string |  | "ABCD", "CDAB", "BADC", "DCBA" |
| `turnaround_delay` | integer |  | Silence time ms |
| `simulated` | boolean | yes | Explicit simulator mode |
| `rs485` | boolean | yes | RS485: let the operating system drive RTS for the transmitter direction (Linux only; adapters with automatic direction control need nothing). |
| `rts_before_send_ms` | integer | yes | RTSBeforeSendMs: with rs485, time the driver is enabled before the first bit is sent. |
| `rts_after_send_ms` | integer | yes | RTSAfterSendMs: with rs485, time the driver stays enabled after the last bit, before the line is released for the answer. |
| `inter_frame_us` | integer | yes | InterFrameUs overrides the inter-frame silence; 0 computes 3.5 character times (1750 us above 19200 baud). |
| `allow_broadcast` | boolean | yes | AllowBroadcast permits writes to unit 0, which every slave on the line executes and none acknowledges. Off by default; reads of unit 0 are always refused. |
| `block_gap_registers` | integer | yes | BlockGapRegisters: as on Modbus TCP, the most unmapped registers one block read spans between two tags (16 when unset). |
| `block_gap_bits` | integer | yes | BlockGapBits: as on Modbus TCP, the most unmapped coils or discrete inputs (bits) one block read spans between two tags (64 when unset). |

## OPCUASettings

OPCUASettings configures OPC-UA Client

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `endpoint_url` | string |  | opc.tcp://192.168.1.100:4840 |
| `security_policy` | string |  | "None", "Basic256Sha256", "Aes128_Sha256_RsaOaep" |
| `security_mode` | string |  | "None", "Sign", "SignAndEncrypt" |
| `auth_mode` | string |  | "Anonymous", "Username", "Certificate" |
| `username` | string | yes |  |
| `password` | string | yes |  |
| `publish_interval_ms` | integer |  | Subscription rate |
| `simulated` | boolean | yes | Explicit simulator mode |

## MQTTSettings

MQTTSettings configures MQTT Broker & Sparkplug B bridge

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `broker_url` | string |  | tcp://broker.example.com:1883 or ssl://... |
| `client_id` | string |  | SCADA-Edge-Gateway-01 |
| `username` | string | yes |  |
| `password` | string | yes |  |
| `clean_session` | boolean |  |  |
| `keep_alive_sec` | integer |  | Default 60 |
| `qos` | integer |  | 0, 1, 2 |
| `payload_format` | string |  | "JSON_TELEMETRY", "SPARKPLUG_B", "RAW_VALUE" |
| `topic_sub_pattern` | string |  | e.g. "sensors/+/telemetry" or "spBv1.0/#" |
| `topic_pub_prefix` | string |  | e.g. "scada/edge/telemetry" |
| `uns_mapper_regex` | string |  | Pattern to extract UNS path from topic |
| `simulated` | boolean | yes | Explicit simulator mode |
| `ingest_path_prefix` | string | yes | IngestPathPrefix: a received message writes only the tags this channel maps to its topic (a Sparkplug metric: a tag this channel maps). Set, a path under this UNS prefix (e.g. "Plant/Edge") that no other channel maps is accepted too: the payload's "path", else the topic without "sensors/". Empty (the default): mapped tags only. A wildcard or a bare "/" is no prefix. |

## NATSSettings

NATSSettings configures NATS Core UNS & Cluster Bridge

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `broker_url` | string |  | nats://127.0.0.1:4222 or remote cluster |
| `auth_token` | string | yes |  |
| `inbound_prefix` | string |  | e.g. "uns.telemetry.&gt;" |
| `outbound_prefix` | string |  | e.g. "uns.command.&gt;" |
| `jetstream_bucket` | string |  | e.g. "scada_uns_snapshots" |
| `queue_group` | string |  | Load balancing queue |
| `simulated` | boolean | yes | Explicit simulator mode |
| `own_broker` | boolean | yes | OwnBroker: read this server's own broker in process, signed in with a reader identity the broker makes for the channel (subscribe its inbound subjects, publish nothing; natsengine.ConnectReader). No credentials: broker_url and auth_token are not used. The inbound subject must lie under uns.telemetry. |

## SerialSettings

SerialSettings configures Raw Serial COM

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `port` | string |  | COM1, /dev/ttyUSB0 |
| `baud_rate` | integer |  | 9600, 115200 |
| `data_bits` | integer |  | 8 |
| `stop_bits` | integer |  | 1 |
| `parity` | string |  | N, E, O |
| `flow_control` | string |  | None, RTS/CTS, XON/XOFF |
| `delimiter` | string |  | "\\r\\n", "\\n" |
| `simulated` | boolean | yes | Explicit simulator mode |

## ModbusRTUTCPSettings

ModbusRTUTCPSettings configures Modbus RTU framing carried over TCP (a
serial device server or gateway in transparent mode): the RTU frame with
its CRC, not the Modbus TCP header.

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `host` | string |  | device server address |
| `port` | integer |  | device server TCP port (often 4001 or 950) |
| `slave_id` | integer |  | unit for devices without a station id |
| `byte_order` | string |  | "ABCD", "CDAB", "BADC", "DCBA" |
| `allow_broadcast` | boolean | yes | permit writes to unit 0 |
| `simulated` | boolean | yes | Explicit simulator mode |
| `block_gap_registers` | integer | yes | BlockGapRegisters: as on Modbus TCP, the most unmapped registers one block read spans between two tags (16 when unset). |
| `block_gap_bits` | integer | yes | BlockGapBits: as on Modbus TCP, the most unmapped coils or discrete inputs (bits) one block read spans between two tags (64 when unset). |

## CANopenSettings

CANopenSettings configures a CANOPEN (and CAN\_RAW) channel. A device's
station\_id is its CANopen node id (1-127).

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `interface` | string |  | Interface: a SocketCAN interface (can0, Linux), or slcan:&lt;port&gt; for an SLCAN adapter on a serial port (slcan:COM5, slcan:/dev/ttyACM0) or a serial device server (slcan:tcp://host:port). |
| `bitrate` | integer | yes | Bitrate in bit/s (default 500000). Set on SLCAN adapters; a SocketCAN interface is configured by the system. |
| `heartbeat_timeout_ms` | integer | yes | HeartbeatTimeoutMs: a node whose heartbeat is older than this is lost and every tag of it is BAD. 0 disables liveness monitoring (not recommended). |
| `node_guarding_ms` | integer | yes | NodeGuardingMs &gt; 0 polls nodes that have no heartbeat with node guarding requests at this period; lost after life_time_factor misses. |
| `life_time_factor` | integer | yes | LifeTimeFactor: missed node guarding periods before a guarded node is lost (default 3). |
| `sdo_timeout_ms` | integer | yes | SDOTimeoutMs bounds every SDO step (default: the channel request timeout, else 500). |
| `sdo_poll_ms` | integer | yes | SDOPollMs: an SDO tag is read from the node at most this often (default 1000); SDO is a request/response service and polling it at the scan rate loads the bus. |
| `pdo_stale_ms` | integer | yes | PDOStaleMs &gt; 0: a PDO or frame value older than this is UNCERTAIN. |
| `nmt_start_on_connect` | boolean | yes | NMTStartOnConnect sends NMT Start to each node when it is first polled. Off by default: an operational node acts on the RPDOs other devices send it. |
| `sync_period_ms` | integer | yes | SyncPeriodMs &gt; 0 makes this channel the SYNC producer. Off by default: two SYNC producers on one bus break synchronous PDOs. |
| `allow_broadcast` | boolean | yes | AllowBroadcast permits NMT commands to node 0 (every node). |
| `simulated` | boolean | yes | Explicit simulator mode |

## LinkStats

LinkStats are a serial or CAN driver's link-level counters. They are
cumulative since the channel started; a rising CRC or timeout count with
GOOD tags is the early sign of a marginal line (termination, biasing,
grounding, a wrong baud rate on one device).

Source: `eaxScada/internal/drivers/link_stats.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `medium` | string |  | e.g. "COM5 19200 8-E-1", "can0", "slcan:COM7" |
| `connected` | boolean |  |  |
| `frames_tx` | integer |  |  |
| `frames_rx` | integer |  |  |
| `crc_errors` | integer |  | CRC (RTU) or LRC (ASCII) |
| `timeouts` | integer |  |  |
| `exceptions` | integer | yes |  |
| `frame_errors` | integer | yes | wrong unit/function, malformed |
| `retries` | integer | yes |  |
| `sdo_requests` | integer | yes | CANopen |
| `sdo_aborts` | integer | yes |  |
| `sdo_timeouts` | integer | yes |  |
| `heartbeat_losses` | integer | yes |  |
| `emcy` | integer | yes |  |
| `nmt_sent` | integer | yes |  |
| `bus_errors` | integer | yes | adapter / interface errors |
| `nodes` | list of [NodeLinkState](#nodelinkstate) | yes |  |
| `suspended_units` | list of integer | yes | Units on a multi-drop serial line that stopped answering and are polled at a reduced rate so they do not starve the others. |
| `identity` | [CIPIdentity](#cipidentity) | yes | EtherNet/IP device: its Identity object, read when the connection opened (absent until it answered). |
| `last_error` | string | yes |  |
| `last_error_at` | integer | yes | When last_error happened (Unix ms). |
| `previous_error` | string | yes | The error before, kept after it cleared: a serial Modbus link clears last_error once the line, or the unit that failed, answers again. |
| `previous_error_at` | integer | yes | When previous_error happened (Unix ms). |
| `recovered_at` | integer | yes | When previous_error cleared (Unix ms). |
| `unit_errors` | list of [UnitLinkError](#unitlinkerror) | yes | Every unit (node, station; -1: the medium) in error now, the oldest first; last_error is the first of them. |

## ChannelStatus

ChannelStatus represents current communication state

Source: `eaxScada/internal/drivers/types.go`

Underlying type: `string`.

| Value | Name | Description |
|---|---|---|
| `ONLINE` | `StatusOnline` |  |
| `CONNECTING` | `StatusConnecting` |  |
| `OFFLINE` | `StatusOffline` |  |
| `ERROR` | `StatusError` |  |
| `DISABLED` | `StatusDisabled` |  |

## Range

Range is a tag's write range. The zero value allows every finite number
and, on a string tag, any text of at most DefaultMaxLength characters.

Source: `eaxScada/internal/writerange/writerange.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `min` | number | yes | Min / Max: the lowest and highest value a write may carry (inclusive). |
| `max` | number | yes |  |
| `step` | number | yes | Step: a written value must be Min + k*Step (0 + k*Step without Min), within a relative tolerance of 1e-9. |
| `values` | list of number | yes | Values: the only values a write may carry (a mode selector: 0, 1, 2). |
| `max_length` | integer | yes | MaxLength: a string tag's longest text, in characters (default 256). |
| `texts` | list of string | yes | Texts: the only texts a write to a string tag may carry. |

## Handover

Handover records where a mapping's path came from (handover.go).

Source: `eaxScada/internal/drivers/types.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `from` | string |  | the producer that held the path ("eaxtags") |
| `at` | integer |  | Unix ms |
| `by` | string | yes | who handed it over |
| `description` | string | yes | Description: the local tag's, the tag's description from then on. |
| `local_tag` | JSON value |  | LocalTag: the local definition as it was (its JSON), for "Return to local tag". |

## NodeLinkState

NodeLinkState is one CANopen node as the master sees it.

Source: `eaxScada/internal/drivers/link_stats.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `node` | integer |  |  |
| `state` | string |  |  |
| `alive` | boolean |  |  |
| `last_seen_ms_ago` | integer |  | -1: never |
| `emcy_code` | string | yes |  |

## CIPIdentity

CIPIdentity is a device's Identity object (class 1, instance 1), read
with Get Attributes All when the connection opens.

Source: `eaxScada/internal/drivers/ethernetip_device.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `vendor_id` | integer |  |  |
| `device_type` | integer |  |  |
| `product_code` | integer |  |  |
| `revision` | string |  | major.minor |
| `status` | integer |  | the Identity object's status word |
| `serial` | string |  | 0x and 8 hex digits |
| `product_name` | string |  |  |
| `raw` | string |  | Raw is the whole Get Attributes All reply, hexadecimal: the byte-string view of the object, for diagnostics. |

## UnitLinkError

UnitLinkError is one unit's current link error (unitTracker).

Source: `eaxScada/internal/drivers/link_stats.go`

| Key | Type | Optional | Description |
|---|---|---|---|
| `unit` | integer |  |  |
| `error` | string |  |  |
| `since` | integer |  | Unix ms: when the unit went into error |
| `last` | integer |  | Unix ms: its latest failure |