# Trace, recall and export genealogy

> Find a part or a lot by its ID or the beginning of it, read its unit page, trace backward to what went into it and forward to where it went, find every unit a suspect lot reached, and export or print the result as CSV, JSON lines or a printed report.

Product: eaxScada · Type: How-to guide · Editions: Pro, Enterprise
Source: https://eaxware.com/docs/eaxscada/how-to/trace-recall-and-export-genealogy/
Verified against commit 9d50b4d.

## Goal

Answer, in minutes, what went into a part and where a lot went: for a customer complaint, a supplier alert or an audit. Everything here only reads; anyone with `genealogy.read` (every signed-in role by default) can do it, and exports need a Process_Supervisor or above.

## Before you start

- Records captured from the PLC or entered by hand ([Capture genealogy from a PLC](/docs/eaxscada/how-to/capture-genealogy-from-a-plc/)).
- Names of operators and signers show as **(name hidden)** unless you have `genealogy.read_personal`; values of tags you may not read show **hidden (no read right)**.

## 1. Find the unit

Open **Genealogy > Search**.

1. Type the **Unit ID**: the whole serial or lot number, or its beginning. Optionally pick a **Type** and a **Status**.
2. Choose **Search**.
   - An exact match lists that unit (every generation of the ID).
   - Without an exact match, the units whose ID starts with what you typed are listed, at most 500; a chip says so, for example "No exact match: 5 IDs start with "GB-10"".
   - With the ID empty, every unit is listed, newest first, a page at a time.
3. Choose **Open** on a row for its unit page, or **Trace** to trace it directly.

The grid has column filters and **Export CSV**. A row whose status is QUARANTINED or whose last result is not PASS is coloured.

## 2. Read the unit page

The unit page shows a properties card (ID, type, status, created, last station with its last result, batch or lot, last record, flags) and five tabs:

| Tab | Shows |
|---|---|
| **Components** | What the unit consumed: component, type, kind, generation, quantity, when linked, by which operation, voided or not |
| **Used in** | The units this one went into |
| **Operations** | Station, step, attempt, start, end, result; select an operation for its measured values with their quality and limits |
| **Timeline** | The operations on a time axis, with the history of their tags |
| **Events** | The unit's records, newest first, a page at a time (**Older** loads the next page) |

A result recorded with Bad or Uncertain quality is marked in its row, never shown as good. A corrected or voided record keeps its original; the header says when the unit was corrected.

With `genealogy.write` you can also act from the page: **Set status** (to QUARANTINED and back needs your e-signature), **Add components**, **Record operation**, and **Correct** or **Void** on a record. Each signed dialog shows you as the signer, read only, and asks for a reason and your password.

## 3. Trace backward or forward

On the unit page choose **Trace backward** or **Trace forward**, or open the **Trace** tab:

- **Direction**: *Backward: what went into it* (components, their components, down to the lots), or *Forward: where it went* (the units it was built into, up to the finished product).
- **Levels** (1 to 100, default 20) and **Units at most** (default 5,000).

Choose **Trace**. The chip says how many units and levels were reached, and whether the trace was cut at a limit. **Chart** draws the units and links, coloured by status; **Values** lists them with their depth. The chart's icons save it as an image or the plotted data as CSV.
[Image: The Trace tab for gearbox GB-1004, direction Backward: what went into it, 20 levels, 5000 units at most, "6 units, 2 levels": the gearbox is linked to its two drive modules DM-0007 and DM-0008 and a screw lot, and the drive modules to a resin lot and a bearing lot, coloured by status (created, finished, consumed).]
[Image: The Trace tab for gearbox GB-1004, direction Backward: what went into it, 20 levels, 5000 units at most, "6 units, 2 levels": the gearbox is linked to its two drive modules DM-0007 and DM-0008 and a screw lot, and the drive modules to a resin lot and a bearing lot, coloured by status (created, finished, consumed).]

A backward trace from a finished gearbox to the lots it contains.
## 4. Recall from a lot

When a material lot is suspect, find every unit it reached. Open **Genealogy > Recall**:

1. Pick the **Lot type** and type the **Lot ID**, such as `resin` and `RES-2611-01`.
2. Optionally set the **Generation** (0: the latest), **Levels at most** (default 50), and tick **Finished units only** to list only finished, shipped and top-level units.
3. Choose **Find affected units**.

The units arrive as they are found; when it is done the chip says "Done: N units affected", with a count per status (IN_PROCESS, CONSUMED, FINISHED, SHIPPED, QUARANTINED...). The grid has a filter box and column filters. Each user runs one recall at a time; a second one is refused until the first ends.

The recall lists units; deciding what to quarantine or whom to notify is yours. To quarantine a unit, open it and use **Set status**.

## 5. Export and print

| What | Where | Formats |
|---|---|---|
| A trace | **Trace** tab: **Download CSV**, **Download JSON lines** | CSV, JSON lines |
| A recall | **Recall** tab: **Download CSV**, **Download JSON lines** | CSV, JSON lines |
| The records of a time range | **Status** tab, *Export the records of a time range*: **From**, **To** (local time), optionally a **Record kind**, then **Download CSV** or **Download JSON lines** | CSV, JSON lines |
| A grid as shown | **Export CSV** above any grid | CSV |

The time-range file holds each record as stored, with its hashes (`prev_hash`, `record_hash`), so it can be checked outside eaxScada; names and values you may not read are hidden. Every export is recorded in the audit trail (`GENEALOGY_EXPORT`).

**Print** on the unit page, the Trace tab and the Recall tab opens a print layout of that report; use your browser's print dialog, which can also save it as PDF.

The same exports are available from the API: `GET /api/genealogy/export?what=trace&key=<unit_key>&dir=backward`, `what=recall&lot_type=…&lot_id=…`, or `what=range&from=…&to=…`, each with `format=csv` or `format=jsonl` ([Genealogy API](/docs/eaxscada/reference/genealogy-api/)).

## Verify

Trace a finished part backward and check that every component and lot you expect is there; then trace one of its lots forward and check that the part is in the list.

## Troubleshooting

| Symptom | Cause and fix |
|---|---|
| "The store is behind (busy; retry)" | A record was acknowledged but not yet in the database; it is applied within seconds. Retry. |
| The trace says it was cut | Raise **Levels** or **Units at most**, or trace from a unit nearer the root. |
| A recall is refused | You already run one: wait for it to finish. |
| Names show "(name hidden)" | You do not have `genealogy.read_personal`. |

## Related

- [Part and lot genealogy](/docs/eaxscada/explanation/genealogy/)
- [Export genealogy for analytics tools](/docs/eaxscada/how-to/export-genealogy-for-analytics-tools/)