# Check screens before deploying (Problems panel)

> Find what would not work on the operator's screen before you deploy - inputs and commands without a tag, conflicting limits, broken tags, screen-only interlocks, stop commands a failed sensor would block, low contrast, missing translations - in the editor's Problems panel, and block deploys while errors remain.

Product: eaxScada · Type: How-to guide · Editions: Starter, Pro, Enterprise
Source: https://eaxware.com/docs/eaxscada/how-to/check-screens-before-deploy/
Status: migrated page, not yet verified against the current code.

## Goal

Before operators get a screen, you know what would not work on it: an input that writes nowhere, a limit that refuses every value, a tag that does not exist, an interlock only the screen enforces. With the deploy gate on, a deploy is refused while errors remain.

## 1. Open the Problems panel

The designer's status bar shows the number of problems on the screen you edit (⚠ errors / warnings). Click it, or press **Ctrl+Shift+M**.
[Image: The Problems panel under the designer, listing the saved project's warnings and information.]
[Image: The Problems panel under the designer, listing the saved project's warnings and information.]

The Problems panel, checking the saved project.
| Check | What it reads |
|---|---|
| **This screen** | the screen as it is in the editor, unsaved changes included; checked again a few seconds after each change |
| **Saved project (as deployed)** | every saved screen and component |

Click a row (or **Select**) to select the object on the canvas, inside its group if needed; a problem on another screen opens that screen first. The grid has column filters, sorting and **Export CSV**. **Check again** runs the check at once.

## 2. Fix what it finds

| Rule | Severity | What it means, and the fix |
|---|---|---|
| `unbound-input` | Error | An input has no tag: it is disabled on the operator's screen. Set **Tag written**. |
| `unbound-command` | Error | A button or action that writes has no tag. |
| `limits-conflict` | Error | Minimum above maximum (every write is refused), a step of 0 or less, or a limit that is not a number. |
| `no-options` | Error | A selector without options, or a toggle whose two values are the same. |
| `duplicate-id` | Error | Two objects have the same id. |
| `nav-target-missing` | Error | A navigation or popup opens a screen that does not exist. |
| `component-missing` | Error | An instance of a component that does not exist. |
| `text-type-mismatch` | Error | A text entry on a numeric tag, or a numeric input on a String tag: the server refuses the write. |
| `param-set-missing-required` | Error | A [parameter set](/docs/eaxscada/how-to/reusable-screens-with-parameters/) has no value for a required parameter. |
| `param-set-value-not-allowed` | Error | A parameter set value is outside the allowed values or folders, of the wrong type, or for an undeclared parameter. |
| `broken-tag` | Warning | A tag that no eaxTag, driver mapping or live tag has. The object shows a Bad value; a write to it is refused (`404`); a missing limit tag refuses every write. |
| `plc-spelling` | Warning | A binding names an eaxPLC variable in the PLC's own spelling (`Plant/Line1/plc-01/Recipes[1].Temp_SP`, or another upper/lower case) instead of its tag path (`Plant/Line1/plc-01/Recipes/1/Temp_SP`). The object shows no value through it. Save the screen again: the save stores the tag path, for the same variable. Or pick the tag from the tag tree. See [PLC spellings are stored as tag paths](#plc-spellings-are-stored-as-tag-paths). |
| `input-no-limits` | Warning | A numeric input without a minimum or a maximum. |
| `write-no-confirmation` | Warning | A command writes a critical tag (watched by a CRITICAL or HIGH alarm, or the e-stop signal) without confirmation. |
| `command-stop-blocks-on-bad-quality` | Warning | A stop or trip command is disabled when its interlock reads a Bad value: a failed sensor would stop the operator from stopping. Set **If the interlock reads a Bad value** to **Allow**. |
| `interlock-client-only` | Warning | An interlock the server does not enforce (not a simple tag comparison): a direct API write is not blocked. See [Enforce interlocks on the server](/docs/eaxscada/how-to/enforce-interlocks/). |
| `interlock-parameter` | Warning | An interlock with a `{...}` that the command's tag path cannot fill in: a tag path interlock refuses every write of the command (fail closed), or never blocks with **Allow**; an expression is enforced on the screen only. Use only the parameters of the command's tag path. See [Interlocks with a parameter](/docs/eaxscada/how-to/enforce-interlocks/#interlocks-with-a-parameter). To list them for a whole project before an upgrade, run `eaxscada interlock-audit --workdir <project folder>` ([List the affected objects before upgrading](/docs/eaxscada/how-to/enforce-interlocks/#list-the-affected-objects-before-upgrading)). |
| `interlock-per-parameter` | Info | An interlock of a command with parameters: for a value in no parameter set, the server evaluates it with the values read from the written tag path. |
| `nav-target-restricted` | Warning | The screen links to, opens or embeds a screen (or a page) with a higher **Required Access Level**: users between the two levels follow the link to "You don't have access to this screen". Raise this screen's level, lower the target's, or remove the link. See [Restrict a screen to a role level](/docs/eaxscada/how-to/restrict-screens-by-access-level/). |
| `screen-access-unknown` | Warning | The screen's stored Required Access Level is not one of `*`, `operator`, `supervisor`, `engineer`, `admin`: the server treats the screen as Administrator only. Choose a level in **Display Settings**. |
| `signature-unprotected` | Warning | The tag needs an electronic signature (another object asks for one) but this object does not say so. |
| `script-not-sandboxed` | Warning | An object's script (a **Run script** action, or another script of the object) uses something a sandboxed script does not have (`window`, `document`, `fetch`, `player`, `this`...): it fails on the operator's screen, marked **Script refused**. Rewrite it with `system.*`. See [Migrate screen scripts to the sandbox](/docs/eaxscada/how-to/migrate-screen-scripts-to-the-sandbox/). |
| `startup-script-not-sandboxed` | Warning | The same for the screen's startup script. |
| `hidden-with-action` | Warning | A hidden object with an action, or one with opacity 0 that a click still operates. |
| `state-disabled-indistinguishable` | Warning | The disabled look is the same as the normal look. See [Style object states](/docs/eaxscada/how-to/style-object-states/). |
| `font-not-portable` | Warning | A font installed only on some computers. See [Fonts and text styles](/docs/eaxscada/how-to/fonts-and-text-styles/). |
| `style-class-missing` | Warning | The object names a [style class](/docs/eaxscada/how-to/use-style-classes/) the project does not define (renamed or deleted, or the screen came from another project). It draws with its own values. Pick a class in the inspector's **Style** section, or create the class again. |
| `low-contrast` | Warning | Text below 4.5:1 contrast on its background (3:1 for large text). |
| `out-of-bounds` | Warning | An object outside the screen. |
| `param-undeclared` | Warning | `{Name}` is used but not declared. |
| `param-target-unbounded` | Warning | A write target uses a parameter without allowed values or folders. |
| `param-unused` | Info | A declared parameter no object uses. |
| `translation-missing` | Info | A text key has no text in one of the project's languages; the runtime shows the default language's text. |
| `alarm-tag-write` | Info | An object writes a tag an alarm watches. |
| `empty-group` | Info | A group with no objects. |
| `placeholder-text` | Info | Text that looks like a placeholder left from an example. |

A `broken-tag` warning that says "no channel brings the PLC's values in" names a real eaxPLC variable, but no channel of this server reads that PLC. Add the PLC's channel (or its NATS bridge) to show the value.

### Isometric screens

An [isometric screen](/docs/eaxscada/how-to/isometric-screens/) gets the rules above for its blocks' bindings and commands, and these rules for its map. Clicking a row selects the block or the connector on the map; for an open connector end, the tile is outlined and centred.

| Rule | Severity | What it means, and the fix |
|---|---|---|
| `iso-block-missing` | Error | The block is not in the block catalog, or its reference is not `<catalog id>@<version>`. The operator's screen draws a plain box with no states. Delete it and place a block from the **Blocks** palette. |
| `iso-block-version-unknown` | Warning | The block is pinned to a version the catalog does not have (a newer one, from another server). It is drawn as the catalog's version. Place the block again from the palette. |
| `iso-block-off-map` | Warning | Part of the block's footprint, in its facing, is off the map. Move it, turn it (**R**), or make the map bigger (nothing selected: **Map**). |
| `iso-block-overlap` | Warning | Two blocks share tiles at heights that overlap: they are drawn inside each other. Move one, or raise it (**PgUp**). Reported once, on the later block. |
| `iso-connector-open-end` | Warning | A pipe or cable tray tile connects on at most one side: no tile of its line at its level and no block port faces it. Extend the line to a port, or erase the tile. Fences and walkways are never reported. |
| `iso-block-hidden` | Warning | A block with bindings, a command or alarm sources is completely behind other blocks in the default view: operators cannot see or click it. Move it, raise it, or choose another default view. |
| `iso-block-outdated` | Info | The catalog has a newer version of the block. The placed block keeps its version until you update it in the inspector (**Catalog block**). |
| `iso-port-unconnected` | Info | Some of a block's ports are connected and one is not (a pump piped on one side only). Draw the line to the named tile, or use a block without that port. A block with no connection at all is not reported. |

### PLC spellings are stored as tag paths

The operator's screen looks a value up by the exact tag path a binding holds. An eaxPLC variable has one tag path: the PLC's prefix, then the variable's path with `/` between its parts (`Plant/Line1/plc-01/Recipes/1/Temp_SP`). A binding typed in the PLC's spelling (`Recipes[1].Temp_SP`, `Line.Mixer.Speed`, another case) used to show no value, while a write through it still reached the variable.

Every save now stores the tag path in each tag field that names an eaxPLC variable in another spelling: saving in the editor, the assistant's screen tools (`scada_create_screen`, `scada_update_screen`, which list what they changed in `bindings_stored_canonical`), **Find and replace**, **Make translatable** and applying a starter template. The variable is found exactly as a write finds it, so the binding still writes the same variable. Nothing else is changed. These stay as typed:

- a path that names no variable of the PLC (an index or member it does not have, a PLC that does not answer);
- a path that a driver mapping, an eaxTag or a simulator owns, in any spelling;
- a path with a parameter (`{Prefix}/...`);
- a text with no `/`, and any path inside an expression or a script.

A screen restored from its history keeps the bindings it had then: `plc-spelling` lists them, and saving it again stores the tag paths.

## 3. Block deploys while errors remain

1. Open **Project → Open / Switch Project... → Operator runtime**.
2. Tick **Block deploy while screens have errors (Problems panel)** and **Save runtime settings**.

From then on, a deploy with errors is refused: `409 {"status": "lint_errors"}` with the counts and the problems, and the Problems panel opens with them. Warnings and information never block.

When you click **Deploy** you may still go ahead: the studio asks for a reason of at least 10 characters (`?lint_override_reason=` on the deploy request). The deploy goes through and is journaled as `DEPLOY_LINT_OVERRIDDEN` in the access and operations audits, with your name, the project and the number of errors.

An automatic deploy (live editing on) never overrides. If the checks are not ready within 5 seconds (just after the server starts), the automatic deploy is refused for now and tried again at the next load.

The Deploy dialog also lists the errors and warnings under **Screen checks**, with what the deploy changes (screens, command targets, scripts, write policy). The Problems panel catches what would not work; the deploy preview shows what will be different for the operators, and asks for a reason when command targets, scripts or the write policy change. See [Review what a deploy changes](/docs/eaxscada/how-to/review-what-a-deploy-changes/).

## Through the API

`GET /api/xref/lint` checks the saved project, `?doc=<screen id>` or `?doc=component:<id>` one document; `POST /api/xref/lint` with `{"screen": ...}` checks a screen that is not saved. Both are for Lead_Engineer and Administrator and change nothing. The answer has `problems` (rule, severity, message, document, object, field, tag), `counts` and the list of `rules`.

`GET /api/plc/canonical?path=<text>` answers which tag path a save stores for a tag field typed as `<text>`. The editor's inspector uses it. Any signed-in user may call it, and it changes nothing.

| Answer | When |
|---|---|
| `200 {"path": "<text>", "canonical": "<tag path>", "plc": "", "symbol": ""}` | `<text>` names an eaxPLC variable in another spelling: a save stores `canonical`. |
| `200 {"path": "<text>", "canonical": ""}` | A save stores `<text>` as typed: it is the tag path already, it names no variable, another producer owns it, or you may not read that variable. |
| `400 {"error": "path is too long"}` | `path` is longer than 1024 characters. |
| `401` | No session. |
| `405` | A method other than GET. |

## Related
