# Compare and merge versions

> Compare any two of the program running on the eaxPLC, the saved project, your drafts and a revision from the program history, POU by POU, with a line diff for ST and a rung diff for ladder, then take the other side's POU, rungs or declarations into your own draft. The running program is never changed.

Product: eaxPLC · Type: How-to guide · Editions: Free, Pro
Source: https://eaxware.com/docs/eaxplc/how-to/compare-and-merge-versions/
Verified against commit bb3d396.

## Goal

See exactly what differs between two versions of the program, for example what runs on the PLC and what the project holds, and bring chosen changes into your draft, a POU, a rung or a declaration block at a time.

## Before you start

- The PLC keeps a project (the Studio shows the **Changes** view).
- Anyone signed in can compare. To take changes you are an engineer (Lead_Engineer or Administrator) and check the POU out; operators and the AI co-pilot are refused.

## 1. Open the compare

In the **Changes** view, click **Compare and merge** in the toolbar, or **Compare** on a POU's row. The **Compare and merge** window opens.

Pick the **Left** and **Right** sides (the **⇄** button swaps them):

| Side | What it holds |
|---|---|
| **Running on the PLC** | The program the PLC runs now. |
| **Project (saved)** | The saved POUs. |
| **My draft** | Your own drafts, over the saved POUs. Where you have no draft of a POU, it shows the saved text and says so. |
| **Git revision...** | A revision from the PLC's program history, picked in a second list. A PLC that keeps no program history has none. |

The default is Running on the PLC against Project (saved). **Reload** reads both sides again.

## 2. Read the differences

The left pane lists the POUs in a grid: **State** (**Same**, **Changed**, **Only left**, **Only right**, **Not known**), **Changes** (for example *Text* or *Rungs: 1 inserted*), **Merge** (what you did), kind, language and the hash of each side. It has a quick filter, **CSV** and an **Only differences** chip.

Select a POU to see its diff on the right:

- **ST POUs**: the two texts side by side, aligned line by line. A changed line is paired with the line most like it, and the changed parts are marked. Unchanged runs are folded (**show** unfolds them).
- **Ladder POUs**: the declarations first (as text), then the rungs side by side, matched by rung id, not by number. Markers say **i** (inserted), **r** (replaced) or **d** (deleted), and the changed elements are outlined. A rung only one side holds shows *Not on this side*.
[Image: The Compare and merge window: Left Running on the PLC, Right Project (saved), a grid with Lamp and PLC_PRG Changed and Valve Same, and the ST diff of PLC_PRG with an added declaration, a changed trip point and a changed call, each change marked, unchanged lines folded, and Prev, Next, Take left and Take right.]
[Image: The Compare and merge window: Left Running on the PLC, Right Project (saved), a grid with Lamp and PLC_PRG Changed and Valve Same, and the ST diff of PLC_PRG with an added declaration, a changed trip point and a changed call, each change marked, unchanged lines folded, and Prev, Next, Take left and Take right.]

An ST POU: the running text against the saved one.
[Image: The rung diff of the ladder POU Lamp: the declarations differ by one added variable, then the rungs side by side with a replaced rung (a jog contact added in parallel) and an inserted rung shown as Not on this side on the left, each with Take left and Take right.]
[Image: The rung diff of the ladder POU Lamp: the declarations differ by one added variable, then the rungs side by side with a replaced rung (a jog contact added in parallel) and an inserted rung shown as Not on this side on the left, each with Take left and Take right.]

A ladder POU: declarations, then rungs matched by id.
### Keyboard

| Keys | Action |
|---|---|
| **Alt+Down** or **F7** | Next change (**Next**) |
| **Alt+Up** or **Shift+F7** | Previous change (**Prev**) |
| **Alt+PageDown** / **Alt+PageUp** | Next / previous POU that differs |
| **Escape** | Close |

## 3. Take changes into your draft

When one side is **My draft**, the other side is "theirs": each POU, rung and declaration block offers **Take theirs** and **Keep mine**. When neither side is your draft, they offer **Take left** and **Take right**.

- **Take** copies that side's whole POU (ST and ladder), one rung (ladder: replaced in place, inserted after the rung before it, or deleted), or the declarations (ladder) into **your draft** of the POU. A draft is started from the saved POU if you have none. An ST POU is taken whole.
- **Keep mine** leaves your draft as it is and marks the change as looked at in the **Merge** column.

The Studio asks for the POU's check-out first, as typing in it does, and sends your pending edit as the draft before taking. It asks to confirm: *Your draft is replaced by it. Nothing runs until you save the draft and it passes the test, accept or deploy gate.* The editor then reloads your draft. For a ladder POU, the PLC generates the merged diagram's ST.

A take is refused, and nothing is written, when:

| Refusal | Why |
|---|---|
| `423` | You do not hold the POU's lock. |
| `409`, *changed since you opened it* | The POU was saved since: reload it. |
| `409`, *belongs to library ... and is read-only* | A library POU. |
| `409`, *is sealed* | Unseal it (signed, with a reason) first. |
| `409`, other | The side has no such POU, holds it as another kind or language, holds only a ladder POU's generated text (no rungs to take), or could not be cut into POUs (use **Import running program**). |

Then save the POU and use **Test edits** or **Build & Deploy** as usual ([Make online edits](/docs/eaxplc/how-to/make-online-edits/)).

## When the running program is not a project revision

After a deploy from outside the project (from eaxScada, over MCP or over NATS) or a rollback to another text, the PLC runs a program that is not the project's last deploy. The window then shows the chip **Running program is not a project revision**, and the running side is the running text itself, cut into its units: a POU it lacks is *Only left* or *Only right*, and a text that cannot be cut into units is *Not known*, never *Same*.

## What it never does

- It never changes the running program, the saved POUs or the project revision. Only your own draft of the POU is written.
- It never deploys. The draft reaches the PLC only through Save, then the normal test, accept or deploy gate.

## Related

- [Make online edits](/docs/eaxplc/how-to/make-online-edits/)
- [Search and replace across the project](/docs/eaxplc/how-to/search-and-replace-across-the-project/)